CAS PRII Series User Manual

The document provides instructions for operating a CAS PRII series scale. It details basic functions like zeroing, taring, PLU saving and calling, user setup modes, sales transactions, payment, and interface settings. Chapters cover operation, PLU management, user settings, sales, payment, and communication protocols.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
131 views26 pages

CAS PRII Series User Manual

The document provides instructions for operating a CAS PRII series scale. It details basic functions like zeroing, taring, PLU saving and calling, user setup modes, sales transactions, payment, and interface settings. Chapters cover operation, PLU management, user settings, sales, payment, and communication protocols.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 26

1

PRECAUTIONS 3
PREFACE, OVERALL VIEW 5
DISPLAY & KEY BOARD 6
COLUMN INSTALLATION 8
OPERATION 9
Chapter 1. Basic Operation 9
Chapter 2. PLU Saving & Calling-up 12
Chapter 3. User' s Set-up Mode 13
Chapter 4. Sales transaction 13
Chapter 5. Payment 16
Chapter 6. Interface in Detail 18
BATTERY MAINTENANCE 21
ERROR MESSAGE 21
SPECIFICATIONS 22

2
3
4
Thank you for purchasing CAS PRΙΙ series.
These series have been designed with CAS reliability, under rigid quality control
and with outstanding performance. Your special departments can enjoy these
high quality reliable CAS products.
We believe that your needs will be satisfied and you will have proper reliability.
This manual will help you with proper operation and care of the PRΙΙ.
Please keep it handy for future reference.

5
PR II - B Front display

PR II - B Rear display

PR II - P Front cover & key

6
KEY FUNCTIONS

KEYS FUNCTIONS

~ Used to enter all the numeric data

~ PLU key.

Function key(Back-light, Power Save


Used to enter PLU setting

Used to clear all the numeric price display


Used to clear sum total price
Used to clear all the daily total prices

Used to correct the zero point

To set or clear tare value

PLU save key.


To make several sales transaction by adding up.

To check total sales amount or finalize sales transaction.

Used to enter the decimal point when price is entered.

+ Used to change back-light setting.(OFF, ON, AUTO)

+ Power Save Mode

+ Used to price per 100g ($/100g)

7
8
● Turn on the ON/OFF switch. Then, the display will show all the segments and
count up "9" to "0".

Chapter 1. Basic Operation

a. Zero function

① Press ZERO key to set Zero.

b. Tare function
Tare means the weight of container. You may use tare function when you weigh an item
with container and measure only the weight of item.

● One time tare

① Place a container on the platter.


EX) 200g of tare.

② Press TARE key to set zero point.


EX) 200g of tare.

9
● Successive tare

③ Place another container on the platter.


EX) 100g of tare.

④ Press TARE key to set zero point.

⑤ After weighing item remove all of the


container from the platter.

⑥ Press TARE key again to set zero.

● NOTICE : To remove TARE funtion press “TARE” Key again after removing the
container from the paltter. Automatic tare clearing function may not be applied to all of PR
series.

10
Chapter 2. PLU Saving & Calling-up

a. Saving unit price on PLU

This section explains how to save unit price in PLU.

Number of PLU Range Remarks


PLU NAME 7 1~7

① Press the 'Fn' key for a few seconds


then, Set-up menu will be shown.

② After input unit of price, press number of


PLU that you want to set up.

b. Calling up PLU

① Press M1 ~ M7 key to call up PLU. e,g,


Press M1 key.
(수정 0,0,plu 1 -> 0, 지정해놓은값, 0)
<그림 수정>

② Press C key to clear and return to the


normal weighing mode.

11
Chapter 3. User’s Set-up Mode

This section explains how to set up the following functions.


KEY Display FUCTION Remarks
bL-At Use back-light when you put on the weight

+ bL-oFF Do not use a back-light.

bL-on Use back-light always

ps - 0 Do not use power save mode.


+
ps - 1 Use power save mode

up- kg Used to price per kg


+
up-100g Used to price per 100g ($/100g).

rS-Co Continually mode

+ rS-PC Command mode

rS-St Stable mode

12
Chapter 4. Sales transaction

PR-Ⅱ can provide inputting the unit price through the numeric key and calling up
PLU.

a. Input the unit price through the numeric key

This section explains how to input the unit price through the numeric key
and complete the sales transaction.

① Place an item on the platter and press


appropriate numeric keys to input unit
price.

EX) 1.99 for unit price.

② Remove the item from the platter.

b. Input the unit price through calling up PLU

① Press M1~M7 key can call up


the PLU.
(수정 0,0,plu 1 -> 0, 지정해놓은값, 0)
<그림 수정>, 별도 첨부
EX) M1

② Place an item on the platter.

③ Remove an item on the platter.

13
c. Adding up several sales transactions for weighed items

● Use + key to makes the adding-up transactions.


● You may either call up PLU or just input the unit price.

① Press M1~M7 key can call up


the PLU.
(수정 0,0,plu 1 -> 0, 지정해놓은값, 0)
<그림 수정>
EX) M1

② Place an item on the platter.

③ Press + key.

④ Remove the item from the platter.

⑤ Input a unit price.


EX) 2.99 for Honey melon

⑥ Place an item on the platter.

14
⑦ Press + key. “Total Price” display says
total price added, and “Unit Price” display
says the number of sales transactions
added.

⑧ Remove the item from the platter.

● You may also place the item on the platter first and then input unit price in the
scale later.

15
Chapter 5. Payment

a. Payment function on total sales amount

① Press ∑ key to call up total price.


(If you want to go back to sales mode,
press zero key.)

② Input payment of consumer by numeric


key.

Ex) 120.00 payment

③ Press Σ key to call up the change


amount.

④ After checking the change amount press


Σ key to go back to normal weighing mode.

16
b. Deleting total sales data

① Press ∑ key to call up total price.


(If you want to go back to sales mode,
press zero key.)

② Press C key to delete “total sales” data.


Clear account message shows up shortly,
and then it goes to normal weighing mode.

③ And then it goes to normal weighing


mode.

17
Chapter 6. Interface in Detail
This function is helpful to understand RS-232C Communication user setting. The
following is the communication information of RS-232C.

● RS-232C Port Connection

 8-BIT ASCII code


 None parity
 1 stop bit
 baud rate 9600

● USB INTERFACE(Device)

18
● RS-232C Protocol

Transmission Data description

DATA Value(HEX) Description

SOH 01h Start of heading

STX 02h Start of text

STA S(53h),U(55h) S: Stable , U:Unstable

SIGN -(2Dh),SP(20h) Sign of the weight data

W5~W0 Weight data

UN1,UN2 KG,LB Unit of Weight

BCC Block check character exclusive or(^)

ETX 03h End of text

EOT 04h End of transmission

19
COMMAND : DC1(0X11) SCALE->PC DATA FORMAT

20
로 수정>
<MAINTENANCE로 수정

LOW BATTERY WARNING

This product is a combination product dry battery and rechargeable battery.


When the battery is low the display shows the " bAt-Lo " sign.
You can replace the battery new one.
If rechargeable battery, please charge immediately.
You can shorten battery life.
If you still use the scale without replacing the battery the scale may provide
incorrect result on measurement.

Error Message on
Description Solution
Display

The "Z-Err" occurs when a current


Please call your CAS
zero point has shifted from the last
dealer.
span calibration.

8l The "oL" is an overload error. Please remove the weight.

Please change new battery.


The "bAt-Lo" is battery low. If rechargeable battery,
please charge immediately.

21
MODEL : PRΙΙ

Dual Dual Dual


Single Single Single
Interval Interval Interval
Capacity
Max Max Max Max Max Max
3/6kg 6kg 6/15kg 15kg 15/30kg 30kg

e=2g e=5g e=10g


e=1g e=2g e=5g
e e=1/2g
e=0.5g
e=2/5g
e=1g
e=0.5/1g
e=2g
e=0.2g e=0.5g e=1g

External 1/3000~ 1/3000~ 1/3000~


1/3000 1/3000 1/3000
Resolution 1/30000 1/30000 1/30000

MAX Tare -1.4995 kg -2.999 kg -5.998 kg -14.995 kg -14.995 kg -29.990 kg


Display 6/6/6(Weight / Unit price/ Total price)
Symbols ZERO, TARE, kg/lb,100g/1oz, ADD, SUM, Low Battery, AC POWER
Keys ZERO, TARE, M1~M7 KEY, FUCTION, ADD, SUM
Direct PLU 7
Unit Conversion
Functions
Power Save Mode
Back-light ON/OFF Control Function
P TYPE : 341 (W) x 435 (D) x 474 (H)[mm] / 134 (W) x 171 (D) x 186
(H)[inch]
Dimension B TYPE : 341 (W) x 383 (D) x 102 (H)[mm] / 134 (W) x 151 (D) x 40
s (H)[inch]
U TYPE : 341 (W) x 435 (D) x 474 (H)[mm] / 134 (W) x 171 (D) x 186
(H)[inch]
Platter size 330 (W) x 235 (D)[mm] / 129.92 (W) x 92.52 (D)[inch]
Weight 2.8 kg
Power 1.5 V x 3 units (D size Battery), Pb 4V/4Ah, 6 V Adapter
Operation Approx. 300 hours (Manganese Battery) / 600 hours (Alkaline at 20 °C /
Time 68 °F) / Backlight off
Operating
Temperatur -10 °C ~ +40 °C / 14 °F ~ 104 °F
e
Option RS232, USB, Manganese Battery, Pole Type

※ Notice: Specifications are subject to change for improvement without notice.