PROJECT CHARTER
Foodsphere Inc.
ENGINEERING MAINTENANCE DEPARTMENT
Project Name Acquisition of 1 Retort Vessel with 3 Basket Capacity
Project Owner Project Supervisor
Cost Center Date
STRATEGIC ALIGNMENT
STRATEGIC GOALS The project is aligned with the corporate strategy in ensuring manufacturing efficiency throuh productivity and
continuous improvement and also strategic investment for long term cost effectiveness.
SCOPE OVERVIEW
Investing in a new 3 baskets capacity retort unit ensures reiability and efficiency. Expected to lessen overall
maintenance cost/ expenses,production downtime/delays and prevent revenue loss associated with equipment
Project Objectives failures. Also, a new retort unit would incorporate modern features and innovations, improving processing product
effeciency and personal safety.
UTILITIES REQUIREMENTS BUILDING REQUIREMENTS
Final Deliverable(s)
Steam Pipe size: 2 inches, Type of pipe: BI Others
Main header: 110 PSI
FDAS/Firepro:
Customer Need Acquisition of retort 3 basket capacity will able to process the excess basket in a less cost of steam.
Scope Boundaries This project is limited only in installation and commisioning of new 3 basket retort.
1. Proper coordination and execution of installation of new retort and other associated equipment must be properly
Project Overlaps planned and observed.
ASSURANCE REQUIREMENTS
Risk Threshold Medium
Scope: HIGH
Project Priorities Schedule: MEDIUM
Cost: HIGH
The following submissions shall be reviewed and approved by the Project Team (PT), Sponsor (S) and Customer (C)
prior to implementation and/or acceptance:
I. Project Initiation
1. Project Charter – S, C, PT
II. Project Planning
1. URS and BOD - S, C, PT
2. Scope of Works, as terms of reference for bidding – S, C, PT
3. Project Costing - S, C, PT
4. EHS Project Plan and Checklist – PT
5. Integrated Project Schedule - S, C, PT
III. Project Execution
Reviews and Approvals 1. Bid documents – PT
2. Engineering Design– S, C, PT
3. CEAs - S, C, PT
4. Factory Acceptance Test – PT
5. Installation – PT
6. Site Acceptance Test – PT , C
7. Status Reports - S, C, PT
8. Validation - S, C, PT
9. Billing/EWAs – PT (Team Leader)
IV. Project Closeout
1. As-built drawings – PT
2. Contractor Close Out Report - PT
3. Project Team Close Out Report - S, C, PT
PROJECT COMMUNICATIONS
UILDING REQUIREMENTS
Control panel
N/A
AFETY REQUIREMENTS
of fluid flowing.
d authorized vendor Technicians and
ations.
No leaks.
tort.
Revision #
1
L= 10 feet
Vessel No of basket: 3
Pipe size: 2 inches, Type of pipe: BI 1. Automatic Steam Controller (Air
Main header: 110 PSI Valve Actuated)
With Steam Trap Size: 1 1/4
2. By-pass valve
Steam Inlet: 1 1/4 (To be connected at
Steam bottom center of retort) Steam Control
Steam Spreader: 1 1/4 pipe size
Hole dia: 7/32 in.
50 Holes at 45 deg. Angle from horizontal
plane upward
Air Vents Main: 3 in dia ; sch.40 Gate valve/Butterfly valve
Gooseneck type
Pressure gauge 0-30 psi ; 4 1/2 in diameter
Temperature
Recording Device Taylor Temperature Controller / Recorder
Process
atic Steam Controller (Air
)
1/4
s valve
e/Butterfly valve
e/Butterfly valve