PM60 Brochure Specifications

The document describes a pulse oximeter device called the PM-60. It has features for spot check and continuous monitoring of patients, and can store and transfer data to a computer. It is portable and has rechargeable batteries to support multiple uses.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
25 views3 pages

PM60 Brochure Specifications

The document describes a pulse oximeter device called the PM-60. It has features for spot check and continuous monitoring of patients, and can store and transfer data to a computer. It is portable and has rechargeable batteries to support multiple uses.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

PM-60

Pulse Oximeter
PM-60 Parameters: SpO 2 , PR

Pulse Oximeter

Suitable for adult, pediatric and neonatal patients


High resolution 2.4” color LCD display
Two selectable working modes: spot check and continuous monitoring
Adjustable audible and visual alarms
Real time data transfer by infrared technology
Spot Check Mode Batteries to support up to 36 hour continuous working
Auto-standby and power off during the idle status
Protective cover and carrying case perfect for portable monitoring needs
Auto-increase the patient IDs
Non-alarm setting for “sensor off ” occasion

Alarm light indicator Slot for hanging strap


Continuous Monitoring Mode
Regular alarm handling
Enable to input patient ID manually
View SpO 2 waveform

2.4” Color LCD

Navigating buttons for


interface operation
Infrared transmission port

Indicator of charging and


working status

Data Storage and Management Functions


For you to easily keep and view patient data.
Spot check: 1~99 IDs with total 4000 sets of
measurement
Continuous monitoring: maximum 96 hour
trend

All data can be transferred to a PC


through a Windows-based software for
review and regular printing.

Protective Cover Carrying Case Charger Stand


PM-60
Pulse Oximeter
Technical Specifications
Safety Power 1.2A
Meet the requirements of IEC60601 series, Battery Li-ion Battery
CE marking according to MDD93/42/EEC 2 hours for charging;24 hours for
continuous working
Type of Protection Class II with internal electric power supply AA batteries
Degree of Protection BF (defibrillation proof ) (for 3 pieces)36 hours for
Protection Against Ingress of Liquid: IPX2 continuous working
Trend memory Monitoring mode
Dimension and Weight Resolution: 2s
Dimension 55(W)X120(H)X30(D)mm Maximum time: 96h
Weight Maximum weight 300g Spot-Check mode
( With battery) Review of up to 4,000 data;
Operation Environment measure up to 99 patients
Temperature 0~40℃ Alarm User-adjustable High and Low limits
Humidity 15~95%(non-condensing) 3-level audible and visual alarm

Storage Environment SpO 2


Temperature -20 ℃ ~ +60℃ Measurement range 0~100%
Humidity 10% ~ 95% Resolution 1%
(Non-condensing) Accuracy ±2%(70~100%,Adult/Pediatric)
±3%(70~100%,Neonate)
Performance Specifications 0~69% unspecified
Display 2.4" color TFT Alarm range 50~100%
Resolution 320×240 Refreshing rate 1s
Multi displays selectable Standard screen display Averaging time 7 s(Sensitivity set HIGH)
Waveform display 9 s(Sensitivity set MED)
Trace 1 plethysmogram waveform 11 s(Sensitivity set LOW)
Indicator Alarm indicator light
Power indicator light Pulse Rate
Pulse tone Range 18~300bpm
Alarm sound Resolution 1bpm
Button tones Accuracy ±3bpm(non-motion)
Interface One dual-purpose socket for ±5bpm(motion)
connecting SpO 2 sensor and Alarm range 18~300bpm
communication cable. Refreshing rate 1s
IR interface Infrared link allows downloading Averaging time 7 s(Sensitivity set HIGH)
realtime patient data to computer 9 s(Sensitivity set MED)
DC Power interface Charger stand for Li-ion battery 11 s(Se nsitivity set LOW)
DC Power Requirements Input voltage 5V DC

Order Information Selectable Sensors


Part Number Description
0852B-01000 Main unit (with standard reusable sensor)
0852-10-77701 Carrying case
0852-21-77412-53 Protective cover
0852-30-77503 Battery charging kit (Euro)
0852-30-77504 Battery charging kit (US)
0852-30-77505 Battery charging kit (UK)
0852-30-77531 Pole mounting kit
0852-30-77491 Data management kit
Partial list of choices, for more details please refer to the price list.

www.mindray.com