UT1-2M90-301084 - 2 - FDF Data Book For Boiler Package (PK-6140ABCD)

This document provides technical specifications and performance data for four centrifugal fans to be used in a petrochemical complex in southern Vietnam. The document includes data sheets, general arrangement drawings, detailed drawings, performance curves, and operation and maintenance manuals for the fans.

Uploaded by

phantuan080213
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
129 views42 pages

UT1-2M90-301084 - 2 - FDF Data Book For Boiler Package (PK-6140ABCD)

This document provides technical specifications and performance data for four centrifugal fans to be used in a petrochemical complex in southern Vietnam. The document includes data sheets, general arrangement drawings, detailed drawings, performance curves, and operation and maintenance manuals for the fans.

Uploaded by

phantuan080213
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 42

PETROCHEMICAL COMPLEX

IN SOUTH OF VIETNAM
TỔ HỢP HÓA DẦU MIỀN NAM
Long Son Petrochemicals Co., Ltd VIỆT NAM Hyundai Engineering Co., Ltd.

Package G Central Utility Plant


Contract No. : LSP-CA-134 FDF Data Book for Boiler Package (PK- Page EPC Project No. : LSP-CA-134
Doc.No. UT1-2M90-301084 Rev. 2 6140A/B/C/D) 1 of 412 EPC Doc.No. : - -

FDF Data Book for Boiler Package (PK-6140A/B/C/D)


PO No. UT1-2C13-PO-300001 LSP Complex
PROJECT Project
VENDOR NAME Package G

Amec Foster Wheeler S.L.U.


PURPOSE
CERTIFIED AS FINAL
R : FOR REVIEW I : FOR INFORMATION
A : FOR APPROVAL x C : FOR CONSTRUCTION

A1: Approved without comments


A2: Approved with comments, re-submit not required
A3: Approved with comments, re-submit for review
A4: Not Approved, re-sbmit for approval
R1: No Comments
R2: Comments as noted

This permission to proceed or review taken on Vendor Data shall


not relive vendor from its responsibilities and liabilities under
purchase order.

DATE: CHECK: APPROV.:

2 10/01/2022 Issue for Final

1 25/03/2021 Issue for Construction RPJ RPJ PMF


0 25/01/2021 Issue for Construction RPJ RPJ PMF

B 03/03/2020 Issue for Approval RAC RAC FPC


DATE
REV. DESCRIPTION PREPARED CHECKED APPROVED
(dd/mm/yyyy)

_____________________________________________________________________________________________
Confidential: This document is confidential and must not be copied or reproduced except with the express
permission of Long Son Petrochemicals Co., Ltd.
PETROCHEMICAL COMPLEX
IN SOUTH OF VIETNAM
TỔ HỢP HÓA DẦU MIỀN NAM
Long Son Petrochemicals Co., Ltd VIỆT NAM Hyundai Engineering Co., Ltd.

Package G Central Utility Plant


Contract No. : LSP-CA-134 FDF Data Book for Boiler Package (PK- Page EPC Project No. : LSP-CA-134
Doc.No. UT1-2M90-301084 Rev. 2 6140A/B/C/D) 2 of 412 EPC Doc.No. : - -

DOCUMENT INFORMATION

The following required information is minimum requirement which need to be


updated each time the document is changed.

Creation by : Amec Foster Wheeler S.L.U

Review Frequency : (This document will be reviewed every new issues)

File Name : UT1-2M90-301084_2_FDF Data Book for Boiler Package (PK-6140 A/B/C/D).pdf
.

List of Qualified Approvers :

Locations of Controlled Copies :

• Master Document  CV  CO  CM  EE  EM
 ES  FT  FF  IE  IF
 LE  ME  PE  PL  PC
 PM  QM  SE  Others

 Copied Document  CV  CO  CM  EE  EM
 ES  FT FF  IE  IF
 LE  ME  PE  PL  PC
(E-file)  PM  QM  SE  Others

Management of Changes :  Internal (MOC No.)


 External (Project Correspondence No)
 New issue

Related Documents : Document Number Document Title

_____________________________________________________________________________________________
Confidential: This document is confidential and must not be copied or reproduced except with the express
permission of Long Son Petrochemicals Co., Ltd.
PETROCHEMICAL COMPLEX
IN SOUTH OF VIETNAM
TỔ HỢP HÓA DẦU MIỀN NAM
Long Son Petrochemicals Co., Ltd VIỆT NAM Hyundai Engineering Co., Ltd.

Package G Central Utility Plant


Contract No. : LSP-CA-134 FDF Data Book for Boiler Package (PK- Page EPC Project No. : LSP-CA-134
Doc.No. UT1-2M90-301084 Rev. 2 6140A/B/C/D) 3 of 412 EPC Doc.No. : - -

REVISION LOG
Date Revised Detail
Rev.
(dd/mm/yyyy) Item Page Article Description

A 14/08/2019 N/A N/A N/A Issue for Approval

B 03/03/2020 N/A N/A N/A Issue for Approval


0 25/01/2021 N/A N/A N/A Issue for Construction
1 25/03/2021 N/A N/A N/A Issue for Construction
2 10/01/2022 N/A N/A N/A Issue for Final

_____________________________________________________________________________________________
Confidential: This document is confidential and must not be copied or reproduced except with the express
permission of Long Son Petrochemicals Co., Ltd.
FDF FAN DATA BOOK FOR BOILER
PACKAGE (PK-6140 A/B/C/D)
INDEX

Data Sheets…………………………………………………………………………………..Page 6

General Arrangement Drawings……………………………………………………Page 24

Detailed Drawings…………………………………………………………………………Page 26

Performance Curves……………………………………………………………………..Page 39

Catalogues…………….……………………………………………………………………..Page 43

O&M Manual………..……………………………………………………………………..Page 136


DATA SHEETS
Client Long Son Petrochemicals Project No. SPD-C-2995
Project Name SPD-C-2995_Long Son Page 1 of 9
Document No. Site

EQUIPMENT DATASHEET CENTRIFUGAL FANS


(API 673)

Item No. C-6140A/B/C/D

Service FD Fan

0 7-Aug-19 ML BL KWC

Rev. Date Description By Chk'd Appr'd Client

Form No.
Project / Job No. SPD-C-2995 Equipment No.
Inquiry No. (RFQ)
Purchase Order No. C002995
Document Number Rev
CENTRIFUGAL FAN (API 673-3RD. EDITION) Page 2 of 9
DATA SHEET Ref. Eng. Stds REV
PURCHASE UNITS OF MEASURE: SI

ABB/Elloit 1480
AFW AFW

m3/h 160,992 196,452 177,948 67,464


N/A
N/A
N/A
N/A
N/A

kg/cm2 0.0177 0.0265 0.0216 0.0031


N/A
N/A
N/A
N/A

1480 1480 1480 1480


N/A
see PC curve

AFW

6163-100

inlet damper close


start with bearing oil temperature to be 21C
Project / Job No. SPD-C-2995 Equipment No.
Inquiry No. (RFQ)
Purchase Order No.
Document Number Rev E
CENTRIFUGAL FAN (API 673-3RD. EDITION) Page 3 of 9
DATA SHEET Ref. Eng. Stds REV

152mm 0.128g/cm3+1.2mm

13 API 673

(see packing list)

DIVISION

Form No. ES-MAC-0301-3, Rev. 1


Project / Job No. SPD-C-2995 Equipment No.
Inquiry No. (RFQ)
Purchase Order No.
Document Number Rev E
CENTRIFUGAL FAN (API 673-3RD. EDITION) Page 4 of 9
DATA SHEET Ref. Eng. Stds REV

1480 1480
94

1876 immersion Hotwatt


C

N/A 456kg/h

100
A36

A36
3/16"
Howden

No

AISI C-1026/30
610mmx 610 mm 2103
610mmx 610mm

Horizontal split

12000 171 87
12000 171 87 2 0.527 2.245 2.366

No NA
1.457 1.295 1.886
3099

No NA

See GA drawing

Form No. ES-MAC-0301-3, Rev. 1


Project / Job No. Equipment No.
Inquiry No. (RFQ)
Purchase Order No.
Document Number Rev E
CENTRIFUGAL FAN (API 673-3RD. EDITION) Page 5 of 9
DATA SHEET Ref. Eng. Stds REV
1 CONSTRUCTION FEATURES (Continued)

Silencers and insulation .

VAW/21VRIB-S11-CE

76dBA

6.35
rainhood

177.8mm dia
4.7625mm
271.4625mm dia
12.7mm
9.525mm

30mm
4.7625mm , 6.35mm
2438x826x457, 6.35mm A36
None
4.7625mm SS316
3.175mm, 4.7625mm
NA
4.7625mm SS316
6.35mm A36
NA
-Clutch , turbine-clutch
clutch-Fan, fan-Clutch

Howden

3548 NM

Form No. ES-MAC-0301-3, Rev. 1


Project / Job No. SPD-C-2995 Equipment No.
Inquiry No. (RFQ)
Purchase Order No.
Document Number Rev
CENTRIFUGAL FAN (API 673-3RD. EDITION) Page 6 of 9
DATA SHEET Ref. Eng. Stds REV
1 CONSTRUCTION FEATURES (Continued)

motor 2652kg 1438kg


2103kg turbine 839kg

0 0 0 0 988 kg
0 0 0 0
0 0 0 0

12640 kg

Howden

See GA

70085-1010-330
AI Tek
motor side shaft 7.6L/minute
0-4600

Not included C

C
Paint inspection

Form No. ES-MAC-0301-3, Rev. 1


Project / Job No. SPD-C-2995 Equipment No.
Inquiry No. (RFQ)
Purchase Order No.
Document Number Rev E
CENTRIFUGAL FAN (API 673-3RD. EDITION) Page 7 of 9
DATA SHEET Ref. Eng.Stds REV

N.A

AI Tek

CPI PDA850
Rack and pinion Double acting 235 ft/lbs

Form No. ES-MAC-0301-3, Rev. 1


Project / Job No. SPD-C-2995 Equipment No.
Inquiry No. (RFQ)
Purchase Order No.
Document Number Rev E
CENTRIFUGAL FAN (API 673-3RD. EDITION) Page 8 of 9
DATA SHEET Ref. Eng. Stds REV

motor side shaft

As per GA specified

Form No. ES-MAC-0301-3, Rev. 1


Project / Job No. Equipment No.
Inquiry No. (RFQ)
Purchase Order No.
Document Number Rev
CENTRIFUGAL FAN (API 673-3RD. EDITION) Page of
DATA SHEET Ref. Eng. Stds REV
1 Notes
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
Form No. ES-MAC-0301-3, Rev. 1
60-TE-BA6152-A, 60-TE-BA6152-B,60-TE-BA6153-A, 60-TE-BA6153-B
60-TE-BB6152-A, 60-TE-BB6152-B,60-TE-BB6153-A, 60-TE-BB6153-B
60-TE-BC6152-A, 60-TE-BC6152-B,60-TE-BC6153-A, 60-TE-BC6153-B
60-TE-BD6152-A, 60-TE-BD6152-B,60-TE-BD6153-A, 60-TE-BD6153-B

Rev Tag Number


Service FD Fan Bearing RTD
P&ID PFD
Equipment Number Line Number
GENERAL Equip.Nozzle/Line Size Line Schedule
Equip./Line Material Equip./Line Insulation
Area Classification Safe
Ambient Temperature Min. Max. 14 °C 40 °C
Specification Detail
Installation Detail
Process Medium Bearing temperature
PROCESS Temperature Min. Norm. Max. 21 °F 87 °C
Pressure Norm. Max. psi
Vibration Thermal Shock
Tag Number
T/C ISA Type
ELEMENT Epoxy. Grounded Ungrounded
RTD Material Resistance Platinum 100 Ohms
Wire Material Gauge Standard copper 0.5106 mm2
Single/Double/Other Diameter Double 3-wire 0.0201 in
Material Aluminum
Terminal Block Conduit Connection Crastin terminal block 1/2 in NPT
HEAD
Extension Type Spring Loaded Neck (Spring loaded bushing) Yes
Nipple Size Union Total Length (N) None 3.1 in

Tag Number No Thermowell


Construction Type Material
Process Connection Material
THERMOWELL Element Connection
Root Diameter Tip Thickness
Length Below Thread / Flange (U)
Lagging Extension (T) Overall Length
Sheathing Coating
Plug & Chain
Treatment Finish
OPTIONS Stamping Back-Up Flange
Factory Calibrated Calibration Certificate
Hydrostatic Testing CRN Number
Stainless Steel Stamped Tag No.
Enclosure Approval Element Ex"d"
SAFETY Protection/Gas Grp./Temp Element
Suitable for use in Environment S.I.L. Number:
Manufacturer Element Rosemount
Well
PURCHASE Model No. Element 214C
Well
Quantity 2 per bearing
Notes: 1- RTD model #: 214 CRTSMB1D3E0067SLE7AR1C1TBXAGN1

INSTRUMENT DATA SHEET


Temp. Element FDfan

1 24/02/2020 ML Issued for information Sheet 1


0 30/01/2020 ML Issued for approval Project No:
No. Date By Chk App Description Doc No: Rev 0
60-SZE-BA6122-A, 60-SZE-BA6122-B, 60-SZE-BA6122-C 60-SZT-BA6122-A, 60-SZT-BA6122-B,60-SZT-BA6122-C
60-SZE-BB6122-A, 60-SZE-BB6122-B, 60-SZE-BB6122-C 60-SZT-BB6122-A, 60-SZT-BB6122-B,60-SZT-BB6122-C
60-SZE-BC6122-A, 60-SZE-BC6122-B, 60-SZE-BC6122-C 60-SZT-BC6122-A, 60-SZT-BC6122-B,60-SZT-BC6122-
60-SZE-BD6122-A, 60-SZE-BD6122-B, 60-SZE-BD6122-C 60-SZT-BD6122-A, 60-SZT-BD6122-B,60-SZT-BD6122-C

Rev Tag Number


Service 60-C-6140A,60-C-6140B,60-C-6140C,60-C-6140D
P&ID PFD
Equipment Number
GENERAL Area Classification
Ambient Temperature Min. Max. 14 °C 38 °C
Specification Number
Installation Detail

Measuring Range 500 in/sec to 1000 in/sec


Sensitivity 200mv peak
Transverse Sensitivity
Frequecy Range 0 to 15 kHz
Temp. Range Temp. Sensitivity
Excitation Voltage Current Excitation
Output Impedance Output Bias Voltage 130Ω Max
Sensing Element Sensing Geometry
PROBE Housing Material 300 SS
Dimension 1.875 in (47.63 mm)
Tip Diameter 4.75mm (0.188 in)
Thread Size Mounting Torque 5/8-18 UNF-2A
Unthreaded Length 1.25in(31.75mm)
Connector
Connector Position
Cable Length 3.05m
Cable Construction

Construction
Output 4-20mA
Power 12-42 DC
SENSOR Scale Factor Aluminum explosion proof enclosure
Housing

Type
Power Supply
Location
Meter Range
Output
MONITOR Relay Module
Alarm Delay
O.K. Circuit

Junction Box
Probe Mounting Bracket
DIMENSIONS Cable Seal
Instrument Rack
Power Supply
OPTIONS Stainless Steel Stamped Tag Number

PURCHASE Manufacturer Speed sensor AI Tek, Transmitter Moore Industries


Model No. 70085-1010-411
Quantity 4 pcs, 1per fan
Notes:

INSTRUMENT DATA SHEET


Sensor - speed
FD fan

Code Sheet 1
0 9-Mar-20 ML Client Doc.
No. Date By Chk App Description Doc No: Rev No: 1
60-TSH-BA6153,60-TSH-BA6152
60-TSH-BB6153,60-TSH-BB6152
60-TSH-BC6153,60-TSH-BC6152
60-TSH-BD6153,60-TSH-BD6152

Rev Tag Number


Service 60-C-6140A, 60-C-6140B, 60-C-6140C, 60-C-6140D
P&ID PFD
Equipment Number Line Number
GENERAL Equip.Nozzle/Line Size Line Schedule
Equip./Line Material Equip./Line Insulation
Area Classifcation
Ambient Temperature Min. Max. 14 °C 40 °C
Specification Number
Installation Detail

Process Medium
Temperature Norm. Max. 21 °C 38 °C
PROCESS Pressure Norm. Max.
Flow (m³/h) Norm. Max.

Case Material
CASE Mounting
Conduit Connection
Type
Contact Form
SWITCH Set Point Adjust. Range
Set Point 21C close, 38C open
Over Range Temperature
S.S.Plate Stamped c/w Tag Number
Fill Type or RTD
Capillary Length
Diameter
Material nikel
THERMAL SYSTEM Armour
Bulb Length 3"
Material 316L Stainless steel
Style immersion
Fitting 1/2" NPT
Material
Process Connection
WELL Insertion Length "U"
Lagging Extention "T"
Thermowell SS Tag Number

Factory Calibrated
Cleaned and Bagged for Oxygen Service
OPTIONS Calibration Certificate
Stainless Steel Stamped Tag Number
Thermowell Velocity Calculations Sheet

Enclosure Approval CE Marked


SAFETY Protection/Gas Group/Temp
Suitable for use in Environment S.I.L. #

Manufacturer ETS Equipment


PURCHASE Temperature Switch Model No. TE70-3

Notes: 1- All materials of construction to be suitable for Potash Plants.


2- All electrical components provided to be CSA approved.

Instrument Data Sheet


Temperature Switch
FD fan

Sheet 1
Client Doc.
No. Date By Chk App Description Doc No: Rev No:
60-VXE-BA6152,60-VYE-BA6152,60-KE-BA6170, 60-VXE-BA6153, 60-VYE-BA6153,60-ZE-BA-6154
60-VXE-BB6152,60-VYE-BB6152,60-KE-BB6170, 60-VXE-BB6153, 60-VYE-BB6153,60-ZE-BB-6154
60-VXE-BC6152,60-VYE-BC6152,60-KE-BC6170, 60-VXE-BC6153, 60-VYE-BC6153,60-ZE-BC-6154
60-VXE-BD6152,60-VYE-BD6152,60-KE-BD6170, 60-VXE-BD6153, 60-VYE-BD6153,60-ZE-BD-6154
60-VXT-BA6152,60-VYT-BA6152,60-KT-BA6170, 60-VXT-BA6153, 60-VYT-BA6153,60-ZT-BA-6154
60-VXT-BB6152,60-VYT-BB6152,60-KT-BB6170, 60-VXT-BB6153, 60-VYT-BB6153,60-ZT-BB-6154
60-VXT-BC6152,60-VYT-BC6152,60-KT-BC6170, 60-VXT-BC6153, 60-VYT-BC6153,60-ZT-BC6154
60-VXT-BD6152,60-VYT-BD6152,60-KT-BD6170, 60-VXT-BD6153, 60-VYT-BD6153,60-ZT-BD-6154
Rev Tag Number
Service FD Fan Proximity probes
P&ID PFD 6163-130-1
Equipment Number
GENERAL Area Classification N-A
Ambient Temperature Min. Max. 14 °C 40 °C
Specification Number
Installation Detail

Measuring Range 0.25 to 2.3mm


Sensitivity Less than 2 mV change
Transverse Sensitivity N/A
Frequecy Range N/A
Temp. Range Temp. Sensitivity N/A
Excitation Voltage Current Excitation N/A
Output Impedance Output Bias Voltage N/A
Sensing Element Sensing Geometry N/A
PROBE Housing Material 316L Stainless steel
Dimension 8 mm
Tip Diameter
Thread Size Mounting Torque 3/8-24 UNF
Unthreaded Length 0 in
Connector Miniature coaxial ClickLoc connector with connector protector
Connector Position
Cable Length 4m
Cable Construction FEP armor and insulation

Construction
Output
Power -24 VDC
SENSOR Scale Factor 7.87 V/mm +/- 6.5%
Housing Bently Nevada Proximitor Model # 330102-20-50-10-02-05

Type
Power Supply
Location
Meter Range
Output
MONITOR Relay Module
Alarm Delay
O.K. Circuit

Junction Box Yes - ATEX Stainless Steel


Probe Mounting Bracket
DIMENSIONS Cable Seal
Instrument Rack
Power Supply
OPTIONS Stainless Steel Stamped Tag Number YES - Stainless Steel

PURCHASE Manufacturer Bently Nevada


Model No. 330102
Notes:

INSTRUMENT DATA SHEET


Sensor - Vibration
FD fan

1 2020-03-10 ML Updated per client comments Code Sheet 1


0 2020-01-30 ML Issued for approval Client Doc.
No. Date By Chk App Description Doc No: Rev No:
60-FZO-BA6123,60-FZC-BA6123,60-FZO-BB6123,60-FZC-BB6123
60-FZO-BC6123,60-FZC-BC6123,60-FZO-BD6123,60-FZC-BD6123

Rev Tag Number


Service 60-C-6140A, 60-C-6140B,60-C-6140C, 60-6140D
P&ID PFD
GENERAL Equipment / Vessel Number
Area Classification
Ambient Temperature Min. Max. 14C 40C
Specification Number
Installation Detail
EQUIPMENT Dimensions Height Diameter

Temperature Min. Max. -20 70


Target Position Min. Max.
PROCESS Target Material

Type
Body Material
Sensing Distance Norm. Max.
Probe Insertion Length
ELEMENT Mounting Orientation
AND BODY Active Face Material
Construction Style
Normal Size
Enclosure Material 316L Stainless steel

Type Limit switch


Form Rating SPCO/SPDT Hermetic seal 24 VDC 830mA
Contact Arrangement Quantity 2
Output Signal Conduit Connection PG9
SWITCH Digital Communication Standard
Power Supply
Load Switching Style
Polarity Protection

Mating Connector
Mounting Adaptor
Mounting Bracket
OPTIONS Magnetic Actuator
Specialty Cabling Requirement
Compliance Standard
Stainless Steel Stamped Tag Number

Enclosure Approval Ex
Protection/Gas Group/Temp Zone 1,2,21 (ATEX) EEx d IIC IP67; Type 4, 4X
SAFETY Suitable for use in Environment S.I.L. Number

Manufacturer Euroswitch
Model No. ES-2321
Quantity 2 per fan
PURCHASE

Notes:

INSTRUMENT DATA SHEET


Limit Switch
FDfan

1 24-02-2020 ML KWC BL For information Sheet 1 1


0 30-01-2020 ML Client Doc. Horizontal Section 1 of 1
No. Date By Chk App Description Doc No: Rev No: 0
60-FV-BA6123, 60-FZVT-BA6123
60-FV-BB6123, 60-FZVT-BB6123
60-FV-BC6123, 60-FZVT-BC6123
60-FV-BD6123, 60-FZVT-BD6123

Rev Tag Number


Service 60-C-6140A,60-C-6140B,60-C-6140C,60-C-6140D,
P&ID PFD
GENERAL Equipment / Vessel Number
Area Classification
Ambient Temperature Min. Max. 14 C 40 C
Specification Number
Installation Detail
EQUIPMENT Dimensions Height Diameter

Temperature Min. Max.


Target Position Min. Max.
PROCESS Target Material

Type
Body Material
Sensing Distance Norm. Max.
Probe Insertion Length
ELEMENT Mounting Orientation
AND BODY Active Face Material
Construction Style
Normal Size
Enclosure Material

Type
Form Rating
Contact Arrangement Quantity
Output Signal Conduit Connection
SWITCH Digital Communication Standard
Power Supply
Load Switching Style
Polarity Protection

Mating Connector
Mounting Adaptor
Mounting Bracket
OPTIONS Magnetic Actuator
Specialty Cabling Requirement
Compliance Standard
Stainless Steel Stamped Tag Number

Enclosure Approval
Protection/Gas Group/Temp
SAFETY Suitable for use in Environment S.I.L. Number

Manufacturer ABB Germany


Model No. V18348-20114310010
Input Signal 4-20 Milli-amp
Positioner Communication Protocal Hart
Options 4-20 milli-amp Feedback Transmitter Board
Conduit Connection 1/2" NPT
Failure Mode Fail in Place on Signal Loss
Notes:

INSTRUMENT DATA SHEET


Position Switch FD fan
Code:

506309 Sheet 1 2
0 10/Mar/2020 ML Client Doc. Horizontal Section 1 of 1
No. Date By Chk App Description Doc No:
APPENDIX V

LUBRICATION INSTRUCTIONS

RECOMMENDED OIL TO USE: ISO VG 68

Fan application
Bearing Quantity of oil for initial fill
and type
RTL 3 15/16, FIXED 64 oz (1.89L)
FD fan
A75D-4775
RTL 3 15/16, FREE 64 oz(1.89L)

Notes:

Drain, flush and refill with oil after the 2 or 3 first weeks of operation.
Oil service life depends on many factors. It is therefore recommended to
perform an oil analysis every three months.
It is also recommended to change the oil at least once per year for unfiltered
static applications.

NOTICE: MAINTAIN OIL LEVEL AT RECOMMENDED LEVEL AT ALL TIMES


WHILE UNIT IS IN OPERATION.
APPENDIX V

Recommended Oils for Sleevoil Bearings

Mineral Oil Brands:


1. Mobil DTE Oil Light, Medium, Heavy Medium, Heavy, Extra Heavy
2. Gulf Harmony 32 to 220
3. Shell Turbo T and Vitrea 32 to 460
4. Exxon Teresstic and/or Teresso 32 to 460
5. Texaco Regal Oil and R&O 32 to 460
6. Citgo Pacemaker T and/or Sentry 32 to 220
7. Conoco Redind and/or Dectol R&O Oil 32 to 460
8. Fina Eolan 32 to 220
9. Pennzoil Pennzbell Oil 32 to 460
10. Phillips 66 Condor 32 to 220
11. Sentry R&O Turbine Oil 32 to 460
12. Unocal 76 Turbine Oil 32 to 460
13. Lubrication Engineers Monolec Turbine Oil 6401 to 6407
14. Almac Brothers Tauras R&O Turbine Oil 32 to 460
15. British Petroleum Turbinol T 32 to 150
16. Castrol Hyspin R&O 32 to 460
17. McCollister R&O Turbine Oil 32 to 460

Synthetic Oil Brands:


1. Mobil SHC 524 to 526 and SHC 624 to 630
2. Exxon Synesstic 32 to 150
3. Phillips 66 Magnus 32 to 150
4. Castrol Brayco 1015 to 1070
5. Lubrication Engineers Monolec ACO 9032 to 9150
6. Lubra Systems SHO 32 to 220

Extra Wetting Oil Brands:


1. Mobil DTE 24, 25, 26, and Fluid 423
2. Exxon Nuto H 32 to 150
3. Shell Tellus 32 to 100
4. Amoco Rykon 32 to 220
5. Texaco Meropa 68 to 220
6. Citgo A/W Hydraulic Oil 32 to 220
GENERAL ARRANGEMENT DRAWINGS
1

1
DETAILED DRAWINGS
T.L.V.
T.L.V.
4 3 2 1
Parts List
ITEM QTY PART NUMBER DESCRIPTION
1 1 0850 ADA RACK AND PINION ROTARY ACTUATOR
2 1 300-BC CONTROLAIR TYPE 300 SERIES FILTER/REGULATOR
3 1 A#190018 OVERRIDE SPACER- DG-102 TO UCF209-28
4 1 A#190026 SHAFT HUB, 1.75" ID
5 1 A#190027 OUTPUT ARM, L=10", H=0.78"
D 6 1 A#190037 YT-400 BRACKET 1 D
7 1 A#190038 YT-400 BRACKET 2
8 1 A#190053 PEDESTAL MOUNT WELDMENT
NOTE: 9 1 A#190072 DRIVE SHAFT
10 2 A#190098 ADAPTER BLOCK FOR VDE/VDI MOUNTING PLATE
11 1 CDP19151-A#190096-00 POSITIONER AND CONTROLS PLATE
12 1 CPD19050-TAG-00 LEGEND PLATE
- TUBING AND FITTINGS NOT FINAL
13 1 DB_20920 ABB - SHAFT ADAPTER FOR TZIDC
- FASTENERS AND HARDWARE NOT SHOWN 14 1 DG-102 DECLUTCHABLE GEARBOX
15 1 EYS116 CONDUIT SEALING FITTING
16 1 NAMUR-BBV LOCKOUT / BLOCK & BLEED VALVE
17 1 TZIDC-200 ABB - EXPLOSION-PROOF PNEUMATIC POSITIONER
18 2 UCF209-28 FLANGE BEARING BLOCK, 1" SHAFT DIAMETER
19 1 YT-400 SWITCHING VALVE

18 12 14 1 2

C C

15
9 17

17

19
19
5
3 16

B B

20 mA = CLOSED

90
CPI AUTOMATION Ltd.
SPECIALISTS IN FLUID POWER & CONTROL
MISSISSAUGA, ON KITCHENER, ON
PH: 905-625-4805 PH: 519-748-0600
FX: 905-629-8409 FX: 519-748-2212
4 mA = OPEN www.cpiautomation.com
THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF CPI AUTOMATION LTD. AND
SHALL NOT BE REPRODUCED, TRANSFERRED TO OTHER DOCUMENTS, DISCLOSED TO
OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE, IN WHOLE OR IN PART,
WITHOUT PRIOR WRITTEN PERMISSION OF CPI AUTOMATION LTD.
CPI AUTOMATION LTD.
THIRD ANGLE PROJECTION TOLERANCES UNLESS DIMENSIONS IN INCHES UNLESS
HOWDEN OTHERWISE SPECIFIED OTHERWISE SPECIFIED
Customer .0 = .1
.00 = .03 REMOVE ALL UNNECESSARY SHARP
.000 = .005 EDGES AND BURRS
A PDA850SAPTX-FS-FRS-M-XP .0000 = .001 A
Description ANGLES = 0 30' DO NOT SCALE DRAWING

OCT 16,
Material Date 2019
REVISION HISTORY OPEN/CLOSE POSITIONS -
CPD19149
REV AUTHOR DESCRIPTION DATE AND ASSOCIATED INPUT SIGNAL Finish Scale NTS Part #
0 AFS INITIAL RELEASE OCT 18, 2019
INCREASED MOUNTING HOLE DIAMETER TO 0.79" [20MM] NOV 11, 2019 Drawn By AFS
1 AFS 1 OF 3
2 AFS UPDATED OPEN/CLOSE POSITIONS AND INPUT SIGNALS MAR 12, 2020 GA19149 3
3 AFS REMOVED SOLENOID VALVE AND UPDATED PLUMBING TO MATCH FIELD SERVICE CHANGES APR 22, 2020 Approved By Sheet Drawing # Rev.
4 3 2 1
4 3 2 1

OUTPUT ARM MAY BE ATTACHED


AT 8 INCREMENTS
D D

R5.91
[150]
NOTES:
10.00
[254] - REFER TO DRAWING FS#19149
FOR CONTROL SCHEMATIC DETAILS
- PLUMBING NOT FINAL
4.88 7.00
1 4X 0.79 THRU [124] [178] 0.78 THRU

C C
4.41
[112]

DETAIL A
13.00 SCALE 1 / 2
[330]

15.00 32.27
[381] [820]

AIR SUPPLY INLET


1.84 (1/4" NPT)
[47]

6.00
[152] POS. TRANSMITTER & SURGE PROTECTOR
CONDUIT ENTRY
( 2 X 1/2" NPT)
8.00
[203]

B B
CONTROL SIGNAL
CONDUIT ENTRY
(1/2" NPT CONDUIT)
22.59
[574]

15.50
[394]

A
8.14
[207]
1.00
0.38 [25] CPI AUTOMATION Ltd.
SPECIALISTS IN FLUID POWER & CONTROL
[10]
MISSISSAUGA, ON KITCHENER, ON
PH: 905-625-4805 PH: 519-748-0600
FX: 905-629-8409 FX: 519-748-2212
www.cpiautomation.com
6.00 4.00
THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF CPI AUTOMATION LTD. AND
[152] [102] SHALL NOT BE REPRODUCED, TRANSFERRED TO OTHER DOCUMENTS, DISCLOSED TO
OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE, IN WHOLE OR IN PART,
WITHOUT PRIOR WRITTEN PERMISSION OF CPI AUTOMATION LTD.
CPI AUTOMATION LTD.
THIRD ANGLE PROJECTION TOLERANCES UNLESS DIMENSIONS IN INCHES UNLESS
HOWDEN OTHERWISE SPECIFIED OTHERWISE SPECIFIED
Customer .0 = .1
.00 = .03 REMOVE ALL UNNECESSARY SHARP
.000 = .005 EDGES AND BURRS
A PDA850SAPTX-FS-FRS-M-XP .0000 = .001 A
Description ANGLES = 0 30' DO NOT SCALE DRAWING

Material Date OCT 8, 2019

-
CPD19149
Finish Scale NTS Part #

Drawn By AFS
2 OF 3 GA19149 3
Approved By Sheet Drawing # Rev.
4 3 2 1
4 3 2 1

D D

C C

ONE SUPPLIED PER ASSEMBLY

B B

CPI AUTOMATION Ltd.


SPECIALISTS IN FLUID POWER & CONTROL
MISSISSAUGA, ON KITCHENER, ON
PH: 905-625-4805 PH: 519-748-0600
FX: 905-629-8409 FX: 519-748-2212
www.cpiautomation.com
THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF CPI AUTOMATION LTD. AND
SHALL NOT BE REPRODUCED, TRANSFERRED TO OTHER DOCUMENTS, DISCLOSED TO
OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE, IN WHOLE OR IN PART,
WITHOUT PRIOR WRITTEN PERMISSION OF CPI AUTOMATION LTD.
CPI AUTOMATION LTD.
THIRD ANGLE PROJECTION TOLERANCES UNLESS DIMENSIONS IN INCHES UNLESS
HOWDEN OTHERWISE SPECIFIED OTHERWISE SPECIFIED
Customer .0 = .1
.00 = .03 REMOVE ALL UNNECESSARY SHARP
.000 = .005 EDGES AND BURRS
A LEGEND PLATE .0000 = .001 A
Description ANGLES = 0 30' DO NOT SCALE DRAWING

Material Default Date OCT 8, 2019


CPD19050-TAG-00
Finish Scale NTS Part #

Drawn By AFS
3 OF 3 GA19149 3
Approved By Sheet Drawing # Rev.
4 3 2 1
HOWDEN COVENT FANS INC., MONTREAL, CANADA
TEL.: 1-450-441-3233, WWW.COVENTFANS.COM
Service: FORCED DRAFT FAN
Vendor: Howden Covent Fans SPD-C-2995-LONG SON
Purchaser Equipment number: 60-C-6140A
Model Number: A75D-4775 First Critical speed: 1880 RPM
Serial Number: A75D-477561630101 Rated BHP: 239 kW
2
Size: 47.75(1213) in(mm) Rated WR : 135 kgm2
Type: Centrifugal fan Rotor Weight: 2,103 kg
Volume: 55 M3/s Design Operating temperature: 54 degC
Static pressure differential: 255 mm H2O Inlet temperature: 40 degC
Rated revolutions per minute: 1480 RPM Howden Covent Ref: Project 6163-100-1
Maximum revolutions per minute: 1480 RPM Manufacturing date: 2020

MADE IN CANADA

HOWDEN COVENT FANS INC., MONTREAL, CANADA


TEL.: 1-450-441-3233, WWW.COVENTFANS.COM
Service: FORCED DRAFT FAN
Vendor: Howden Covent Fans SPD-C-2995-LONG SON
Purchaser Equipment number: 60-C-6140B
Model Number: A75D-4775 First Critical speed: 1880 RPM
Serial Number: A75D-477561630102 Rated BHP: 239 kW
Size: 47.75(1213) in(mm) Rated WR2 : 135 kgm2
Type: Centrifugal fan Rotor Weight: 2,103 kg
Volume: 55 M3/s Design Operating temperature: 62.8 degC
Static pressure differential: 255 mm H2O Inlet temperature: 40 degC
Rated revolutions per minute: 1480 RPM Howden Covent Ref: Project 6163-100-2
Maximum revolutions per minute: 1480 RPM Manufacturing date: 2020

MADE IN CANADA
HOWDEN COVENT FANS INC., MONTREAL, CANADA
TEL.: 1-450-441-3233, WWW.COVENTFANS.COM

Service: FORCED DRAFT FAN


Vendor: Howden Covent Fans SPD-C-2995-LONG SON
Purchaser Equipment number: 60-C-6140D
Model Number: A75D-4775 First Critical speed: 1880 RPM
Serial Number: A75D-477561630104 Rated BHP: 239 kW
2
Size: 47.75(1213) in(mm) Rated WR : 135 kgm2
Type: Centrifugal fan Rotor Weight: 2,103 kg
Volume: 55 M3/s Design Operating temperature: 54 degC
Static pressure differential: 255 mm H2O Inlet temperature: 40 degC
Rated revolutions per minute: 1480 RPM Howden Covent Ref: Project 6163-100-4
Maximum revolutions per minute: 1480 RPM Manufacturing date: 2020

MADE IN CANADA

HOWDEN COVENT FANS INC., MONTREAL, CANADA


TEL.: 1-450-441-3233, WWW.COVENTFANS.COM

Service: FORCED DRAFT FAN


Vendor: Howden Covent Fans SPD-C-2995-LONG SON
Purchaser Equipment number: 60-C-6140C
Model Number: A75D-4775 First Critical speed: 1880 RPM
Serial Number: A75D-477561630103 Rated BHP: 239 kW
2
Size: 47.75(1213) in(mm) Rated WR : 135 kgm2
Type: Centrifugal fan Rotor Weight: 2,103 kg
Volume: 55 M3/s Design Operating temperature: 54 degC
Static pressure differential: 255 mm H2O Inlet temperature: 40 degC
Rated revolutions per minute: 1480 RPM Howden Covent Ref: Project 6163-100-3
Maximum revolutions per minute: 1480 RPM Manufacturing date: 2020

MADE IN CANADA
PERFORMANCE CURVES
Fan Performance Curve
S V.2.1.0.18 6163-100 SD99 1500RPM.DSGXHowden Covent Fans Inc.
Tel: (450) 441-3233 www.howden.com

Customer AMEC Foster Wheeler Reference 6163-100


Service Forced Draft Date 2019-08-29
Fan Type A75D-4775-700C0-EP Estim. by T.Vuong
Elevation 4 Meter
Accessories: Inlet Damper, Inlet Box, Inlet Silencer, Inlet Rainhood, Non Std Evase - Evase Loss: Yes 15 m/s,

ILD SPEED TEMP DENSITY MASS FanPs Pt1 Ps2 FLOW POWER
Fan1
Deg RPM °C kg/m³ Kg/h mm H2O mm H2O mm H2O m³/h kW
Peak Load 58 1480 34 1.1346 201924 216.0 0 216.0 177969 196.0
MCR Load 44 1480 34 1.1346 182700 177.0 0 177.0 161026 176.0
Test Block 90 1480 40 1.1160 219240 255.0 0 255.0 196452 239.0
Min Load 3 1480 34 1.1346 76536 31.00 0 31.00 67456 114.0

300

250

200
kW

150
Power

100

50

0
0 50 100 150 200 250 300
Inlet Volume Flow m³/h/1000
500 100%

450 90%

400 80%
mm H2O

350 70%

300 60%
Fan Static Pressure

250 50%

200 40%

150 30%

100 20%

50 10%

0 0%
0 50 100 150 200 250 300
Inlet Volume Flow m³/h/1000
Sound Levels S V.2.1.0.186163-100 SD99 1500RPM.DSGX

Howden Covent Fans Inc.


Tel: (450) 441-3233 www.howden.com

Fan1
Customer AMEC Foster Wheeler Reference 6163-100
Service Forced Draft Date 2019-08-29
Fan Type A75D-4775-700C0-EP Estim. By. T.Vuong
Elevation 4 Meter
Accessories Inlet Damper, Inlet Silencer, Inlet Rainhood, Evase,

NOISE DATA IS ESTIMATED AND NOT GUARANTEED & PARTIAL CLOSURE OF VIV OR ILD MAY INCREASE STATED NOISE LEVELS

- Tolerance on noise data is +/- 5 dB per band and +/- 3 dB overall


- Noise data is based on free field environment
- Noise levels do not consider the effects of mechanical noises from other equipment (motor, bearings, etc…) or any other background noises

Selection column: Min Load


Blade Passage Frequency: 271 Hz
Sound levels in octave band are in dB - Overall sound levels are in dBA

***When the fan housing required acoustical insulation, both inlet and outlet flexible connector if any and duct must be insulated to the same transmission loss as the
fan from the inlet silencer to the outlet silencer.

Frequency (Hz) 63 125 250 500 1000 2000 4000 8000 Overall

Lw Free inlet
Lw Ducted inlet

Lw Ducted outlet
No comments 135
118

120
135
118

120
101
116

116
104
114

114
104
109

109
100
101

101
95
96

96
93
93

93
119
114

115

Lw Total 122 122 119 117 112 104 99 96 118


for unducted inlet silencer selection

Lw Housing 104 102 104 108 100 101 96 93 108


Lp at 1.0 m from casing 89 87 89 93 85 86 81 78 93
Lp at 1.0 m from ins. casing 85 83 79 70 55 49 43 30 73
6 in. acoustic media (6-8 lb/ft3) + 18 ga. galvanized steel
SPEED-TORQUE CURVE
Howden Covent Fans Inc.

Fan Model : A75D-4775

Job No. 6163-100 Item No. Forced Draft

Power Consumption : 239 kW @ 40 °C

Rotor Wk² : 135.0 kg-m² Motor Rating 263.2 kW


Damper for Start-up? Y Motor FLT 1698 N-m

Torque at 1,480 rpm 40 °C 1,544 N-m Hot- Run Open Damper


14 °C 842 N-m Cold- Start Closed Damper

1800

1600

1400

1200
No comments
1000
TORQUE N-m

Hot-Run Open Damper

Cold Start Closed Damper

800

600

400

200

0
0 148 296 444 592 740 888 1036 1184 1332 1480

SPEED rpm