UT1-2M90-301084 - 2 - FDF Data Book For Boiler Package (PK-6140ABCD)
UT1-2M90-301084 - 2 - FDF Data Book For Boiler Package (PK-6140ABCD)
IN SOUTH OF VIETNAM
TỔ HỢP HÓA DẦU MIỀN NAM
Long Son Petrochemicals Co., Ltd VIỆT NAM Hyundai Engineering Co., Ltd.
_____________________________________________________________________________________________
Confidential: This document is confidential and must not be copied or reproduced except with the express
permission of Long Son Petrochemicals Co., Ltd.
PETROCHEMICAL COMPLEX
IN SOUTH OF VIETNAM
TỔ HỢP HÓA DẦU MIỀN NAM
Long Son Petrochemicals Co., Ltd VIỆT NAM Hyundai Engineering Co., Ltd.
DOCUMENT INFORMATION
File Name : UT1-2M90-301084_2_FDF Data Book for Boiler Package (PK-6140 A/B/C/D).pdf
.
• Master Document CV CO CM EE EM
ES FT FF IE IF
LE ME PE PL PC
PM QM SE Others
Copied Document CV CO CM EE EM
ES FT FF IE IF
LE ME PE PL PC
(E-file) PM QM SE Others
_____________________________________________________________________________________________
Confidential: This document is confidential and must not be copied or reproduced except with the express
permission of Long Son Petrochemicals Co., Ltd.
PETROCHEMICAL COMPLEX
IN SOUTH OF VIETNAM
TỔ HỢP HÓA DẦU MIỀN NAM
Long Son Petrochemicals Co., Ltd VIỆT NAM Hyundai Engineering Co., Ltd.
REVISION LOG
Date Revised Detail
Rev.
(dd/mm/yyyy) Item Page Article Description
_____________________________________________________________________________________________
Confidential: This document is confidential and must not be copied or reproduced except with the express
permission of Long Son Petrochemicals Co., Ltd.
FDF FAN DATA BOOK FOR BOILER
PACKAGE (PK-6140 A/B/C/D)
INDEX
Data Sheets…………………………………………………………………………………..Page 6
Detailed Drawings…………………………………………………………………………Page 26
Performance Curves……………………………………………………………………..Page 39
Catalogues…………….……………………………………………………………………..Page 43
Service FD Fan
0 7-Aug-19 ML BL KWC
Form No.
Project / Job No. SPD-C-2995 Equipment No.
Inquiry No. (RFQ)
Purchase Order No. C002995
Document Number Rev
CENTRIFUGAL FAN (API 673-3RD. EDITION) Page 2 of 9
DATA SHEET Ref. Eng. Stds REV
PURCHASE UNITS OF MEASURE: SI
ABB/Elloit 1480
AFW AFW
AFW
6163-100
152mm 0.128g/cm3+1.2mm
13 API 673
DIVISION
1480 1480
94
N/A 456kg/h
100
A36
A36
3/16"
Howden
No
AISI C-1026/30
610mmx 610 mm 2103
610mmx 610mm
Horizontal split
12000 171 87
12000 171 87 2 0.527 2.245 2.366
No NA
1.457 1.295 1.886
3099
No NA
See GA drawing
VAW/21VRIB-S11-CE
76dBA
6.35
rainhood
177.8mm dia
4.7625mm
271.4625mm dia
12.7mm
9.525mm
30mm
4.7625mm , 6.35mm
2438x826x457, 6.35mm A36
None
4.7625mm SS316
3.175mm, 4.7625mm
NA
4.7625mm SS316
6.35mm A36
NA
-Clutch , turbine-clutch
clutch-Fan, fan-Clutch
Howden
3548 NM
0 0 0 0 988 kg
0 0 0 0
0 0 0 0
12640 kg
Howden
See GA
70085-1010-330
AI Tek
motor side shaft 7.6L/minute
0-4600
Not included C
C
Paint inspection
N.A
AI Tek
CPI PDA850
Rack and pinion Double acting 235 ft/lbs
As per GA specified
Construction
Output 4-20mA
Power 12-42 DC
SENSOR Scale Factor Aluminum explosion proof enclosure
Housing
Type
Power Supply
Location
Meter Range
Output
MONITOR Relay Module
Alarm Delay
O.K. Circuit
Junction Box
Probe Mounting Bracket
DIMENSIONS Cable Seal
Instrument Rack
Power Supply
OPTIONS Stainless Steel Stamped Tag Number
Code Sheet 1
0 9-Mar-20 ML Client Doc.
No. Date By Chk App Description Doc No: Rev No: 1
60-TSH-BA6153,60-TSH-BA6152
60-TSH-BB6153,60-TSH-BB6152
60-TSH-BC6153,60-TSH-BC6152
60-TSH-BD6153,60-TSH-BD6152
Process Medium
Temperature Norm. Max. 21 °C 38 °C
PROCESS Pressure Norm. Max.
Flow (m³/h) Norm. Max.
Case Material
CASE Mounting
Conduit Connection
Type
Contact Form
SWITCH Set Point Adjust. Range
Set Point 21C close, 38C open
Over Range Temperature
S.S.Plate Stamped c/w Tag Number
Fill Type or RTD
Capillary Length
Diameter
Material nikel
THERMAL SYSTEM Armour
Bulb Length 3"
Material 316L Stainless steel
Style immersion
Fitting 1/2" NPT
Material
Process Connection
WELL Insertion Length "U"
Lagging Extention "T"
Thermowell SS Tag Number
Factory Calibrated
Cleaned and Bagged for Oxygen Service
OPTIONS Calibration Certificate
Stainless Steel Stamped Tag Number
Thermowell Velocity Calculations Sheet
Sheet 1
Client Doc.
No. Date By Chk App Description Doc No: Rev No:
60-VXE-BA6152,60-VYE-BA6152,60-KE-BA6170, 60-VXE-BA6153, 60-VYE-BA6153,60-ZE-BA-6154
60-VXE-BB6152,60-VYE-BB6152,60-KE-BB6170, 60-VXE-BB6153, 60-VYE-BB6153,60-ZE-BB-6154
60-VXE-BC6152,60-VYE-BC6152,60-KE-BC6170, 60-VXE-BC6153, 60-VYE-BC6153,60-ZE-BC-6154
60-VXE-BD6152,60-VYE-BD6152,60-KE-BD6170, 60-VXE-BD6153, 60-VYE-BD6153,60-ZE-BD-6154
60-VXT-BA6152,60-VYT-BA6152,60-KT-BA6170, 60-VXT-BA6153, 60-VYT-BA6153,60-ZT-BA-6154
60-VXT-BB6152,60-VYT-BB6152,60-KT-BB6170, 60-VXT-BB6153, 60-VYT-BB6153,60-ZT-BB-6154
60-VXT-BC6152,60-VYT-BC6152,60-KT-BC6170, 60-VXT-BC6153, 60-VYT-BC6153,60-ZT-BC6154
60-VXT-BD6152,60-VYT-BD6152,60-KT-BD6170, 60-VXT-BD6153, 60-VYT-BD6153,60-ZT-BD-6154
Rev Tag Number
Service FD Fan Proximity probes
P&ID PFD 6163-130-1
Equipment Number
GENERAL Area Classification N-A
Ambient Temperature Min. Max. 14 °C 40 °C
Specification Number
Installation Detail
Construction
Output
Power -24 VDC
SENSOR Scale Factor 7.87 V/mm +/- 6.5%
Housing Bently Nevada Proximitor Model # 330102-20-50-10-02-05
Type
Power Supply
Location
Meter Range
Output
MONITOR Relay Module
Alarm Delay
O.K. Circuit
Type
Body Material
Sensing Distance Norm. Max.
Probe Insertion Length
ELEMENT Mounting Orientation
AND BODY Active Face Material
Construction Style
Normal Size
Enclosure Material 316L Stainless steel
Mating Connector
Mounting Adaptor
Mounting Bracket
OPTIONS Magnetic Actuator
Specialty Cabling Requirement
Compliance Standard
Stainless Steel Stamped Tag Number
Enclosure Approval Ex
Protection/Gas Group/Temp Zone 1,2,21 (ATEX) EEx d IIC IP67; Type 4, 4X
SAFETY Suitable for use in Environment S.I.L. Number
Manufacturer Euroswitch
Model No. ES-2321
Quantity 2 per fan
PURCHASE
Notes:
Type
Body Material
Sensing Distance Norm. Max.
Probe Insertion Length
ELEMENT Mounting Orientation
AND BODY Active Face Material
Construction Style
Normal Size
Enclosure Material
Type
Form Rating
Contact Arrangement Quantity
Output Signal Conduit Connection
SWITCH Digital Communication Standard
Power Supply
Load Switching Style
Polarity Protection
Mating Connector
Mounting Adaptor
Mounting Bracket
OPTIONS Magnetic Actuator
Specialty Cabling Requirement
Compliance Standard
Stainless Steel Stamped Tag Number
Enclosure Approval
Protection/Gas Group/Temp
SAFETY Suitable for use in Environment S.I.L. Number
506309 Sheet 1 2
0 10/Mar/2020 ML Client Doc. Horizontal Section 1 of 1
No. Date By Chk App Description Doc No:
APPENDIX V
LUBRICATION INSTRUCTIONS
Fan application
Bearing Quantity of oil for initial fill
and type
RTL 3 15/16, FIXED 64 oz (1.89L)
FD fan
A75D-4775
RTL 3 15/16, FREE 64 oz(1.89L)
Notes:
Drain, flush and refill with oil after the 2 or 3 first weeks of operation.
Oil service life depends on many factors. It is therefore recommended to
perform an oil analysis every three months.
It is also recommended to change the oil at least once per year for unfiltered
static applications.
1
DETAILED DRAWINGS
T.L.V.
T.L.V.
4 3 2 1
Parts List
ITEM QTY PART NUMBER DESCRIPTION
1 1 0850 ADA RACK AND PINION ROTARY ACTUATOR
2 1 300-BC CONTROLAIR TYPE 300 SERIES FILTER/REGULATOR
3 1 A#190018 OVERRIDE SPACER- DG-102 TO UCF209-28
4 1 A#190026 SHAFT HUB, 1.75" ID
5 1 A#190027 OUTPUT ARM, L=10", H=0.78"
D 6 1 A#190037 YT-400 BRACKET 1 D
7 1 A#190038 YT-400 BRACKET 2
8 1 A#190053 PEDESTAL MOUNT WELDMENT
NOTE: 9 1 A#190072 DRIVE SHAFT
10 2 A#190098 ADAPTER BLOCK FOR VDE/VDI MOUNTING PLATE
11 1 CDP19151-A#190096-00 POSITIONER AND CONTROLS PLATE
12 1 CPD19050-TAG-00 LEGEND PLATE
- TUBING AND FITTINGS NOT FINAL
13 1 DB_20920 ABB - SHAFT ADAPTER FOR TZIDC
- FASTENERS AND HARDWARE NOT SHOWN 14 1 DG-102 DECLUTCHABLE GEARBOX
15 1 EYS116 CONDUIT SEALING FITTING
16 1 NAMUR-BBV LOCKOUT / BLOCK & BLEED VALVE
17 1 TZIDC-200 ABB - EXPLOSION-PROOF PNEUMATIC POSITIONER
18 2 UCF209-28 FLANGE BEARING BLOCK, 1" SHAFT DIAMETER
19 1 YT-400 SWITCHING VALVE
18 12 14 1 2
C C
15
9 17
17
19
19
5
3 16
B B
20 mA = CLOSED
90
CPI AUTOMATION Ltd.
SPECIALISTS IN FLUID POWER & CONTROL
MISSISSAUGA, ON KITCHENER, ON
PH: 905-625-4805 PH: 519-748-0600
FX: 905-629-8409 FX: 519-748-2212
4 mA = OPEN www.cpiautomation.com
THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF CPI AUTOMATION LTD. AND
SHALL NOT BE REPRODUCED, TRANSFERRED TO OTHER DOCUMENTS, DISCLOSED TO
OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE, IN WHOLE OR IN PART,
WITHOUT PRIOR WRITTEN PERMISSION OF CPI AUTOMATION LTD.
CPI AUTOMATION LTD.
THIRD ANGLE PROJECTION TOLERANCES UNLESS DIMENSIONS IN INCHES UNLESS
HOWDEN OTHERWISE SPECIFIED OTHERWISE SPECIFIED
Customer .0 = .1
.00 = .03 REMOVE ALL UNNECESSARY SHARP
.000 = .005 EDGES AND BURRS
A PDA850SAPTX-FS-FRS-M-XP .0000 = .001 A
Description ANGLES = 0 30' DO NOT SCALE DRAWING
OCT 16,
Material Date 2019
REVISION HISTORY OPEN/CLOSE POSITIONS -
CPD19149
REV AUTHOR DESCRIPTION DATE AND ASSOCIATED INPUT SIGNAL Finish Scale NTS Part #
0 AFS INITIAL RELEASE OCT 18, 2019
INCREASED MOUNTING HOLE DIAMETER TO 0.79" [20MM] NOV 11, 2019 Drawn By AFS
1 AFS 1 OF 3
2 AFS UPDATED OPEN/CLOSE POSITIONS AND INPUT SIGNALS MAR 12, 2020 GA19149 3
3 AFS REMOVED SOLENOID VALVE AND UPDATED PLUMBING TO MATCH FIELD SERVICE CHANGES APR 22, 2020 Approved By Sheet Drawing # Rev.
4 3 2 1
4 3 2 1
R5.91
[150]
NOTES:
10.00
[254] - REFER TO DRAWING FS#19149
FOR CONTROL SCHEMATIC DETAILS
- PLUMBING NOT FINAL
4.88 7.00
1 4X 0.79 THRU [124] [178] 0.78 THRU
C C
4.41
[112]
DETAIL A
13.00 SCALE 1 / 2
[330]
15.00 32.27
[381] [820]
6.00
[152] POS. TRANSMITTER & SURGE PROTECTOR
CONDUIT ENTRY
( 2 X 1/2" NPT)
8.00
[203]
B B
CONTROL SIGNAL
CONDUIT ENTRY
(1/2" NPT CONDUIT)
22.59
[574]
15.50
[394]
A
8.14
[207]
1.00
0.38 [25] CPI AUTOMATION Ltd.
SPECIALISTS IN FLUID POWER & CONTROL
[10]
MISSISSAUGA, ON KITCHENER, ON
PH: 905-625-4805 PH: 519-748-0600
FX: 905-629-8409 FX: 519-748-2212
www.cpiautomation.com
6.00 4.00
THIS DRAWING CONTAINS PROPRIETARY INFORMATION OF CPI AUTOMATION LTD. AND
[152] [102] SHALL NOT BE REPRODUCED, TRANSFERRED TO OTHER DOCUMENTS, DISCLOSED TO
OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE, IN WHOLE OR IN PART,
WITHOUT PRIOR WRITTEN PERMISSION OF CPI AUTOMATION LTD.
CPI AUTOMATION LTD.
THIRD ANGLE PROJECTION TOLERANCES UNLESS DIMENSIONS IN INCHES UNLESS
HOWDEN OTHERWISE SPECIFIED OTHERWISE SPECIFIED
Customer .0 = .1
.00 = .03 REMOVE ALL UNNECESSARY SHARP
.000 = .005 EDGES AND BURRS
A PDA850SAPTX-FS-FRS-M-XP .0000 = .001 A
Description ANGLES = 0 30' DO NOT SCALE DRAWING
-
CPD19149
Finish Scale NTS Part #
Drawn By AFS
2 OF 3 GA19149 3
Approved By Sheet Drawing # Rev.
4 3 2 1
4 3 2 1
D D
C C
B B
Drawn By AFS
3 OF 3 GA19149 3
Approved By Sheet Drawing # Rev.
4 3 2 1
HOWDEN COVENT FANS INC., MONTREAL, CANADA
TEL.: 1-450-441-3233, WWW.COVENTFANS.COM
Service: FORCED DRAFT FAN
Vendor: Howden Covent Fans SPD-C-2995-LONG SON
Purchaser Equipment number: 60-C-6140A
Model Number: A75D-4775 First Critical speed: 1880 RPM
Serial Number: A75D-477561630101 Rated BHP: 239 kW
2
Size: 47.75(1213) in(mm) Rated WR : 135 kgm2
Type: Centrifugal fan Rotor Weight: 2,103 kg
Volume: 55 M3/s Design Operating temperature: 54 degC
Static pressure differential: 255 mm H2O Inlet temperature: 40 degC
Rated revolutions per minute: 1480 RPM Howden Covent Ref: Project 6163-100-1
Maximum revolutions per minute: 1480 RPM Manufacturing date: 2020
MADE IN CANADA
MADE IN CANADA
HOWDEN COVENT FANS INC., MONTREAL, CANADA
TEL.: 1-450-441-3233, WWW.COVENTFANS.COM
MADE IN CANADA
MADE IN CANADA
PERFORMANCE CURVES
Fan Performance Curve
S V.2.1.0.18 6163-100 SD99 1500RPM.DSGXHowden Covent Fans Inc.
Tel: (450) 441-3233 www.howden.com
ILD SPEED TEMP DENSITY MASS FanPs Pt1 Ps2 FLOW POWER
Fan1
Deg RPM °C kg/m³ Kg/h mm H2O mm H2O mm H2O m³/h kW
Peak Load 58 1480 34 1.1346 201924 216.0 0 216.0 177969 196.0
MCR Load 44 1480 34 1.1346 182700 177.0 0 177.0 161026 176.0
Test Block 90 1480 40 1.1160 219240 255.0 0 255.0 196452 239.0
Min Load 3 1480 34 1.1346 76536 31.00 0 31.00 67456 114.0
300
250
200
kW
150
Power
100
50
0
0 50 100 150 200 250 300
Inlet Volume Flow m³/h/1000
500 100%
450 90%
400 80%
mm H2O
350 70%
300 60%
Fan Static Pressure
250 50%
200 40%
150 30%
100 20%
50 10%
0 0%
0 50 100 150 200 250 300
Inlet Volume Flow m³/h/1000
Sound Levels S V.2.1.0.186163-100 SD99 1500RPM.DSGX
Fan1
Customer AMEC Foster Wheeler Reference 6163-100
Service Forced Draft Date 2019-08-29
Fan Type A75D-4775-700C0-EP Estim. By. T.Vuong
Elevation 4 Meter
Accessories Inlet Damper, Inlet Silencer, Inlet Rainhood, Evase,
NOISE DATA IS ESTIMATED AND NOT GUARANTEED & PARTIAL CLOSURE OF VIV OR ILD MAY INCREASE STATED NOISE LEVELS
***When the fan housing required acoustical insulation, both inlet and outlet flexible connector if any and duct must be insulated to the same transmission loss as the
fan from the inlet silencer to the outlet silencer.
Frequency (Hz) 63 125 250 500 1000 2000 4000 8000 Overall
Lw Free inlet
Lw Ducted inlet
Lw Ducted outlet
No comments 135
118
120
135
118
120
101
116
116
104
114
114
104
109
109
100
101
101
95
96
96
93
93
93
119
114
115
1800
1600
1400
1200
No comments
1000
TORQUE N-m
800
600
400
200
0
0 148 296 444 592 740 888 1036 1184 1332 1480
SPEED rpm