0% found this document useful (0 votes)
33 views

SC Precision Grout Product Data 2193944

The document provides technical data and instructions for SC Precision Grout, a non-shrink, non-metallic cement-based grout. It describes the product's uses, benefits, testing results, specifications, storage requirements, and application instructions for placing grout in various consistencies and conditions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views

SC Precision Grout Product Data 2193944

The document provides technical data and instructions for SC Precision Grout, a non-shrink, non-metallic cement-based grout. It describes the product's uses, benefits, testing results, specifications, storage requirements, and application instructions for placing grout in various consistencies and conditions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

T E C H N I C A L D A T A

SC PRECISION GROUT
Non-shrink, Non-metallic grout

DESCRIPTION APPLICATION (cont.)


SC PRECISION GROUT is a non-shrink, non-metallic , a height suitable to provide a head of grout during place-
high-flow, cement-based grout. SC PRECISION GROUT ment. On all sides, provide a minimum 1” (2.54 cm) hori-
is formulated for a wide variety of grouting applications, zontal clearance between the base plate and forms.
from plastic to fluid through a controlled, positive expan- Forms should be at least 1” (2.54 cm) higher than the
sion. Designed to provide effective load bearing for high bottom of the base plate.
flow precision grouting applications. Mixing: Small quantities of grout may be hand mixed in
a concrete mixing pan until lump free. For large quantities
USE and continuous pours, mix using a mortar mixer with rub-
SC PRECISION GROUT is an ideal product for interior or ber tipped blades or appropriate grout pump for a mini-
exterior grouting of architectural and structural precast mum of 5 minutes. Start with minimum water require-
concrete components, structural column base plates, ma- ments.
chinery bases, anchoring bolts, cable anchorages, dow- Always add water to mixer first, then slowly add powder.
els, bearing pads, keyway joints, crane rails etc. Use only the amount of water required for the desired
SC PRECISION GROUT is used in power plants, steel placement consistency. Mix in two steps: Add 2/3 of the
mills, paper mills, oil refineries, food plants, sewage and water, add grout, after partial mixing add the remaining
water treatment plants or anywhere a high-quality engi- 1/3 of the water for desired consistency. Thoroughly mix
neered grout is required. total quantity for an additional 2 to 3 minutes. Do not mix
more than can be placed before in 40 minutes.
FEATURES / BENEFITS TYPICAL PERFORMANCE DATA

Plastic Flowable Fluid


• High flow/High early compressive strength capability
• Minimize project downtime Water / 50 lb. 6.5 - 6.8 pints 6.8 - 7.8 pints 7.8 - 8.4 pints
• Controlled positive expansion for maximum effective Setting Time (ASTM C191)
bearing
Initial Set 1:50 hrs 3:10 hrs 4:00 hrs
• Non-metallic / non-corrosive
• Pourable / pumpable versatility Final Set 3:00 hrs: 3:40 hrs 5:40 hrs
• Excellent freeze / thaw resistance Compressive Strength (ASTM C109)
• Can be extended with pea stone for deep applica- Plastic Flowable Fluid
tions
• Resistant to thermal shock 1 day 4,300 psi 3,500 psi 3,000 psi
• USDA accepted 3 days 5,800 psi 5,300 psi 4,600 psi

SPECIFICATIONS / COMPLIANCES 7 days 8,700 psi 7,600 psi 5,900 psi


28 days 11,000 psi 10,275 psi 8,800 psi
Corp of Engineers CRD C621 Grade A, B & C
Expansion Percentage (ASTM C1090)
ASTM C1107/1107M. Grade A, B & C (formerly known as
CRD C621), ASTM C827 Plastic Flowable Fluid
1 day 0.07 0.03 0.02
APPLICATION 3 days 0.07 0.03 0.02
Preparation: Remove all dirt, oil, and loose or foreign 14 days 0.07 0.03 0.02
material. Any metal in contact with grout must be free of
rust, oil, grease, and other foreign matter which would 28 days 0.07 0.03 0.02
limit bond. Concrete surface must be sound and rough- Flexural Strength (ASTM C-78) = 1315 psi @ 28 days
ened to insure proper bonding. Tensile Strength (ASTM C-190) = 600 psi @ 28 days
Prior to placing grout, surface must be saturated surface
dry (SSD), if possible for an hour. Remove all excess Split Tensile Strength (ASTM C-496) = 735 psi @ 28 days
water before placement of grout. Bolts, base plates and Note: The data shown is based on controlled laboratory testing. Rea-
equipment must be secure and rigid before placement of sonable variation from test results shown can be expected. Field and
grout. laboratory testing should be controlled on the basis of the desired
placing consistency, rather than strictly on water content.
All materials and surfaces in contact with the grout should
be conditioned between 50°- 80°F for proper perfor-
mance. Provide heating or cooling, as necessary, to
compensate for temperature extremes and changes in
cure time
Forms: Allow for the continuous placement of grout. Pro-
visions for venting to avoid air entrapment must be made.
Placing from one side, provide a 45o angle in the forms to 1511 Baltimore Ave, Suite 600
Kansas City, MO 64108
www.specchem.com 866.791.8700
Revised 04/24/23
APPLICATION (cont.) SHELF LIFE / STORAGE
Dry-Pack/Damp-Pack: When mixed with a minimum SC PRECISION GROUT should be stored in a cool, dry
amount of water (4.8-5.5 pints) a very stiff/dry-pack con- interior area. At no time should material be exposed to
sistency can be achieved for applications not requiring high moisture, rain, or snow conditions. When stored in
forms. Dry pack/damp pack consistency will exhibit the original, tightly closed container, the shelf life is one
higher strengths than grout mixed to a plastic consisten- year from the date of manufacture.
cy.

Placing: Place continuously and quickly. Start from one PACKAGING / YIELD
side to avoid air entrapment. Be sure grout fills spaces
and remains in contact with plate. Use a rod or strapping 50 lb (22.7Kg) multiple plastic lined bag will yield approxi-
to help move the grout in large or difficult applications. mately 0.45 cu. ft. in a fluid condition.
DO NOT VIBRATE. Place grout only to the bottom of the 50% by weight extension (25 lbs) of 3/8” pea stone will
base plate. yield approximately 0.59 cu. ft.

Curing: Immediately cover with clean, wet rags and keep


moist until final set. After final set, remove rags and apply
TECHNICAL SERVICES
an ASTM C309 curing compound, such as SpecChem
For assistance, contact technical services at: 866-791-
Cure & Seal 25 or SpecChem Cure & Seal 25 WB.
8700 816-968-5600www.specchemllc.com
24 HOUR EMERGENCY CONTACT:
Special Conditions:
VelocityEHS
Deep application: Pre-washed and graded 3/8” (1 cm)
1-(800)255-3924 (North America)
pea gravel should be used in large applications (greater
+1-813-248-0585 (International)
than 1’ x 1’) and thicker than 3” (7.62 cm) as follows:
1-300-954-583 (Australia)
0-800-591-6042 (Brazil)
3”-5” (7.62-12.7 cm): Add 25% of 3/8” (1 cm)
400-120-0751 (China)
pea gravel per 50 lb bag of grout.
000-800-100-4086 (India)
5” (12.7 cm) and over: Add 50% of 3/8” (1 cm)
800-099-0731 (Mexico)
pea gravel per 50 lb bag of grout.
Made in America
Place in 6” lifts with proper reinforcement

Hot weather conditions: Accelerates setting time and


causes premature drying of the grout. Keep the grout
WARRANTY
cool. Store unopened bags in the shade. Provide shade
for area to be grouted. Use cool or chilled mixing water.
Protect grout from direct sun exposure for up to 24 hours
after grouting. For additional information, refer to ACI
305 (Recommended Practices for Hot Weather Concret-
ing). NOTICE-READ CAREFULLY
CONDITIONS OF SALE
SpecChem offers this product for sale subject to and limited by the warranty which
Cold weather conditions: Retards strength gain and set may only be varied by written agreement of a duly authorized corporate officer of
time. Warm the grout above 50°F. Raise the temperature SpecChem. No other representative of or for SpecChem is authorized to grant any
warranty or to waive limitation of liability set forth below.
of the area to be grouted with space heaters or steam. WARRANTY LIMITATION
Warm the mixing water. Cover and insulate the grout to SpecChem warrants this product to be free of manufacturing defects. If the product
retain warmth. The minimum temperature (ambient, sub- when purchased was defective and was within use period indicated on container or
carton, when used, SpecChem will replace the defective product with new product
strate, and grout) for grouting is 40oF (5oC) unless special without charge to the purchaser. SpecChem makes no other warranty, either ex-
provision are followed. For additional information, refer to pressed or implied, concerning this product. There is no warranty of merchantability.
ACI 306 (Recommended Practices for Cold Weather
Concreting)

LIMITATIONS / PRECAUTIONS
DO NOT place at temperatures below 40oF (5oC) unless
special provisions are followed. At low temperatures, wa-
ter requirement should be field tested.

When nearby equipment causes vibration of the grout,


during set, such equipment should be shut down for a
period of 24 hours (at 73oF (23oC)). DO NOT mix over 5
minutes. DO NOT over water; this can cause bleeding or
separation. DO NOT retemper. DO NOT add cement,
sand, or admixtures.

Avoid hazards by following all precautions found in the


Safety Data Sheets (SDS), product labels, and technical 1511 Baltimore Ave, Suite 600
literature. Kansas City, MO 64108
www.specchem.com 866.791.8700
Revised 04/24/23