ELECTRO-PROPORTIONAL VALVES—FLOW CONTROL
SP08-20A Poppet, 2-Way, Normally Closed
DESCRIPTION
A proportional solenoid-operated, two-way, poppet-type, normally closed, screw-in
hydraulic cartridge valve for low-leakage blocking and load-holding applications
OPERATION
When de-energized, the SP08-20A acts as a check valve, allowing flow from 1 to 2,
and blocking flow from 2 to 1. When energized, the 2 to 1 flow path is opened.
Flow is proportional to current applied to the coil. Flow varies with manual override.
Note: If low voltage is expected on the machine, 12 or 24 volt systems will
require the use of 10 volt or 20 volt coils respectively. See “SP Valves and Coil
Operating Parameters,” page 2.002.1.
FEATURES
• Industry-common cavity. • Efficient wet-armature construction.
• Continuous-duty rated coils. • Optional waterproof E-Coils rated up to IP69K.
• Manual override option.
RATINGS
Operating Pressure: 207 bar (3000 psi)
Flow: 30.3 lpm (8 gpm) nominal; see performance charts
Minimum Operating Dither/Pulse Frequency: 70 Hz
SYMBOL Hysteresis: Less than 5% up to 85% of I-max.; Less than 10% above 85% of I-max.
Max. Internal Leakage: 5 drops per minute at 207 bar (3000 psi)
Operating Temperature: -40 to 100°C (-40° to 212°F) with standard Buna N seals
-26 to 204°C (-15°F to 400°F) with Fluorocarbon seals
-54 to 107°C (-65°F to 225°F) with Polyurethane seals
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Filtration: See page 9.010.1; Installation: No Restrictions. See page 9.020.1
Cavity: VC08-2; See page 9.108.1; Cavity Tool: CT08-2XX; See page 8.600.1
Seal Kit: SK08-2X-T; See page 8.650.1
Coil Nut: Part No. 7004400
PERFORMANCE
WIDE OPEN PRESSURE DROP FLOW vs. CURRENT at Various Differential Pressures
2 to 1 at 1.2A, 12 VDC Coil 32 cSt/150 sus oil at 40C
22.1/320 75.6/20.0
207 bar
PRESSURE bar/psi
19.3/280
16.6/240
MAX. 68.0/18.0 3000 psi
13.8/200
60.5/16.0
11.0/160
MIN. 104 bar
8.3/120 52.9/14.0
5.5/80
1500 psi
45.4/12.0
FLOW lpm/gpm
2.8/40
37.8/10.0 34.5 bar
7.6 15.1 22.7 30.3
2 4 6 8
30.2/8.0
500 psi
FLOW lpm/gpm Nominal Flow Rating
22.7/6.0 10.3 bar
TYPICAL PRESSURE RESPONSE 150 psi
15.1/4.0
at 3000 psi with 12 VDC Coil
68.1/18
7.6/2.0
56.8/15
FLOW lpm/gpm
1.00A 0
45.4/12 10 20 30 40 50 60 70 80 90 100 110
34.1/9 PERCENT of MAX. CONTROL CURRENT
0.80A
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1
22.7/6
0.65A AMP (12 Volt Coil) 100 Hz Dither
11.4/3
0.50A
35 69 103 138 172 207
500 1000 1500 2000 2500 3000
2.009.1 ®
HYDRAFORCE.com
Blue rectangles are links to other catalog pages. ®
HYDRAFORCE
SP08-20A
PERFORMANCE (cont’d.) DIMENSIONS
PERCENT I-MAX. vs. TEMPERATURE COIL MUST BE INSTALLED 1.41 1.40
for 10 or 20 VDC Coil (for 10V Coil I-Max. = 1.15A) DIA.
WITH LETTERING UP 35.8 35.6
Curves show percent of nominal system voltage
minus 1.5V drop across controller
102
115% Manual
100 Override
98 ‘M’
96 10 0.75
PERCENT of I-MAX.
0%
94 85 19.1
%
92 ACROSS
90 FLATS
88 TORQUE
86 3.16 4–5 ft-lbs
80.1 (5.4–6.8 Nm) E-Coil
84 Standard
82 Coil View 1.91 View
80
48.6
78
-4 32 68 104 140 176
-20 0 20 40 60 80
TORQUE
19–21 ft-lbs
Screen (25.8–28.5 Nm)
Standard
Recommended Electronic Controllers:
See page 2.001.1 or our Electronics catalog.
MATERIALS TO ORDER
Cartridge: Weight: 0.10 kg. 8-20A__ - __ __ __ - __ - __ __ __ __ __
SP08-20A
(0.23 lbs.) Steel with hardened
work surfaces. Zinc-plated
exposed surfaces. Buna N
O-rings and polyester Option
elastomer back-up standard. None (Blank) Voltage
Manual Override M 0 Less Coil**
Standard Ported Body: Weight:
10 10 VDC (D- or E-Coil)
0.16 kg. (0.35 lbs.) Anodized For Manual Override details
see page 1.001.1 12 12 VDC (D- or E-Coil)
high-strength 6061 T6 aluminum
alloy, rated to 207 bar (3000 psi); 20 20 VDC (E-Coil)
Ductile iron bodies available; 24 24 VDC (D- or E-Coil)
Porting **Includes Std. D-Coil Nut.
dimensions may differ. Cartridge Only 0
See page 8.008.1. SAE 6 6T
Note: 10 VDC and 20 VDC coils
should be used for most continuous-
Standard Coil: Weight: 0.11 kg. SAE 8 8T duty applications. Consult factory.
(0.25 lbs.); Unitized thermoplas- 1/4 in. BSP* 2B
tic encapsulated, Class H high 3/8 in. BSP* 3B
temperature magnetwire; 1/2 in. BSP* 4B
See page 3.200.1. Coil Termination E-Coil D-Coil
*BSP Body; U.K. Mfr. Only Deutsch DT04-2P ER (IP69K) DR (IP65)
E-Coil: Weight: 0.14 kg. (0.3 lbs.);
Fully encapsulated with rugged Metri-Pak 150 EY (IP69K) DY (IP65)
Seals Dual Lead Wires EL (IP69K) DL (IP65)
external metal shell; Rated up to
Buna N (Std.) N Amp Jr. Timer EJ (IP67) —
IP69K with integral connectors;
Fluorocarbon V DIN 43650 EG (IP65) DG (IP65)
See page 3.400.1.
Polyurethane P Dual Spades — DS (IP65)
For Coil with Zener Diode, add “/Z” to option code.
For example: “ER/Z”. Not available on all models.
See coil option info. on pages 3.200.1 & 3.400.1
®
HYDRAFORCE.com 2.009.2