GFDP-204-52-MC-DS-02-018 DS-Closed Drain Pump-Ph1 Rev1

This document provides a data sheet for a closed drain pump for phase 1 of the Garraf Final Development Plan project. The data sheet includes operating conditions, site data, materials specifications, and other technical details for the pump.

Uploaded by

Mr ElEcTrOn
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
152 views7 pages

GFDP-204-52-MC-DS-02-018 DS-Closed Drain Pump-Ph1 Rev1

This document provides a data sheet for a closed drain pump for phase 1 of the Garraf Final Development Plan project. The data sheet includes operating conditions, site data, materials specifications, and other technical details for the pump.

Uploaded by

Mr ElEcTrOn
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Internal Ctrl. No.

: 461116-100106-43436-0018
Doc No:
GFDP-204-52-MC-DS-02-018
PETRONAS
Date:
16-May-2013

Rev: Page
Data Sheet for Closed Drain Pump for Phase-1
1 1 of 7

DATA SHEET FOR CLOSED DRAIN PUMP FOR PHASE-1

FOR

GARRAF FINAL DEVELOPMENT PLAN (GFDP)

This document was issued previously as Rev.0


with title "data sheet for closed drain pump for
Well pad; doc no. GFDP-204-52-MC-DS-02-
018".

Revision No. Revision Description Date of Issue


1 Issued for Bid 16-May-2013

Prepared By Reviewed By Approved By


Revision No.
Initials Date Initials Date Initials Date
1 TR 16-May-2013 SK 16-May-2013 AE 16-May-2013

PROJECT DOCUMENTS ARE CONTROLLED DOCUMENTS.

Class 1
Internal Ctrl. No.: 461116-100106-43436-0018
GARRAF FINAL DEVELOPMENT PLAN (GFDP)

Document No.: GFDP-204-52-MC-DS-02-018


Revision : 1
Page : 2 of 7

Data Sheet for Closed Drain Pump for Phase-1

REVISION HISTORY

Rev. Date Description of Change


A 23-Jan-13 Issued for Review
0 21-Mar-13 Issued for Bid
Internal Ctrl. No.: 461116-100106-43436-0018

GARRAF FINAL DEVELOPMENT PLAN (GFDP)

Document No.: GFDP-204-52-MC-DS-02-018


Revision : 1

Page : 3 of 7
1
Data Sheet for Closed Drain Pump for Phase-1
2

3 APPLICABLE TO: PROPOSALS PURCHASE AS BUILT


4 SERVICE: Closed Drain Pump STANDARD: API 610 ,11th Edition
5 SITE: Garraf Final Development Plan ORIENTATION: Vertical
6 MANUFACTURER: MODEL:
7 NOTES: INFORMATION BELOW TO BE COMPLETED: BY PURCHASER BY MANUFACTURER BY MANUFACTURER OR PURCHASER
8 DATA SHEETS REVISIONS
9 ITEM NO. ATTACHED ITEM NO. ATTACHED ITEM NO. ATTACHED NO. DATE BY
10 PUMP Note-3 1
11 MOTOR Note-3 2
12 GEAR NA 3
13 TURBINE NA 4
14 APPLICABLE OVERLAY STANDARD(S): GFDP-COM-52-MC-SP-GE-014
15 OPERATING CONDITIONS (5.1.3) Note-6 LIQUID (5.1.3)
16 CAPACITY, NORMAL 10.0 (m 3/h) RATED VTA (m3/h) LIQUID TYPE OR NAME Well Fluid
17 OTHER HAZARDOUS FLAMMABLE TOXIC / CORROSIVE (5.1.5)
18 SUCTION PRESSURE MAX./ RATED 0 (barg) (NOTE-28) MIN. NORMAL MAX.
19 DISCHARGE PRESSURE RATED 26 (barg) PUMPING TEMP (°C) 46 70
20 DIFFERENTIAL PRESSURE RATED (bar) VAPOR PRESS. (bara) 0.249
21 DIFF. HEAD RATED 270 (m) NPSHA 7 (m) DENSITY (kg/m 3) @ PT 874-965 868-957
22 HYDRAULIC POWER VTA (KW) VISCOSITY (cP) @ PT 10.89 8.7
23 PROCESS VARIATIONS (5.1.4) SPECIFIC HEAT, Cp (kJ/kg °C)
24 STARTING CONDITIONS (5.1.4) Open Discharge Valve / Automatic CHLORIDE CONCENTRATION (6.5.2.4) Refer Note 27 (PPM)
25 SERVICE: CONTINUOUS INTERMITTENT(STARTS/DAY) H2S CONCENTRATION 100 (PPM) WET (5.12.1.12c)
26 PARALLEL OPERATION REQ'D (5.1.13) CORROSIVE / EROSIVE AGENT (5.12.1.9)
29 SITE DATA (5.1.3)
31 LOCATION: (5.1.30) MATERIALS (5.12.1.1) (Note 13)
32 INDOOR HEATED OUTDOOR UNHEATED ANNEX H CLASS (5.12.1.1) S-6
34 ELECTRICAL AREA CLASSIFICATION (5.1.24 / 6.1.4) MIN DESIGN METAL TEMP (5.12.4.1) -5 (°C)
35 CL Zone 1 GR IIA DIV 3 REDUCED HARDNESS MATERIALS REQ'D. (5.12.1.12)
36 WINTERIZATION REQ'D TROPICALIZATION REQ'D. BARREL/CASE CS IMPELLER S-6
37 CASE/IMPELLER WEAR RINGS
38 SITE DATA (5.1.30) SHAFT
39 ALTITUDE 3 (m) BAROMETER (bar) DIFFUSERS
40 RANGE OF AMBIENT TEMPS: MIN / MAX. -5 / 55 (°C) MOUNTING PLATE ASTM A 516 GR 60/70
41 RELATIVE HUMIDITY: MIN / MAX 23 / 69 (%) Note: All components in contact with process fluid shall comply with NACE MR-0175 / ISO 15156
42 PERFORMANCE
43 UNUSUAL CONDITIONS: (5.1.30) DUST FUMES PROPOSAL CURVE NO. RPM
44 OTHER SAND STORM IMPELLER DIA. RATED MAX. MIN. (mm)
45 IMPELLER TYPE
46 DRIVER TYPE RATED POWER (kW) EFFICIENCY (%)
47 INDUCTION MOTOR STEAM TURBINE GEAR MINIMUM CONTINUOUS FLOW:
48 OTHER THERMAL (m 3/h) STABLE (m 3/h)
49 PREFERRED OPER. REGION TO (m 3/h)
50 MOTOR DRIVER (6.1.1 / 6.1.4) ALLOWABLE OPER. REGION TO (m 3/h)
51 MANUFACTURER (Note -15) MAX HEAD @ RATED IMPELLER (m)
52 18 (HOLD) (kW) (RPM) MAX POWER @ RATED IMPELLER (kW)
53 FRAME ENCLOSURE Ex' de NPSHR AT RATED CAPACITY (m) (5.1.10)
54 HORIZONTAL VERTICAL SERVICE FACTOR MAX SUCTION SPECIFIC SPEED (5.1.11)
55 VOLTS/PHASE/HERTZ 400 / 3 / 50 MAX SOUND PRESS LEVEL REQD 85 @ 1 m distance (dBA) (5.1.16)
56 TYPE SQUIRREL CAGE INDUCTION MOTOR EST MAX SOUND PRESS. LEVEL (dBA) (5.1.16)
57 MINIMUM STARTING VOLTAGE (6.1.5) EST MAX SOUND POWER LEVEL (dBA) (5.1.16)
58 INSULATION Class F TEMP. RISE Class B UTILITY CONDITIONS (5.1.3)
59 FULL LOAD AMPS ELECTRICITY VOLTAGE PHASE HERTZ
60 LOCKED ROTOR AMPS DRIVERS 400 3 50
61 STARTING METHOD DOL HEATING
62 LUBE SYSTEM VOLTAGE DIP 80% OTHER (6.1.5)
63
64 STEAM MAX. PRESS. MAX. TEMP. MIN. PRESS. MIN. TEMP.
65 DRIVERS - - - -
66 HEATING - - - -
67 COOLING WATER: (5.1.19) SOURCE NOT AVAILABLE
68 SUPPLY TEMP. (°C) MAX. RETURN TEMP. (°C)
69 NORM. PRESS. (bar) DESIGN PRESS. (bar)
70 MIN. RET. PRESS. (bar) MAX. ALLOW. D.P. (bar)
71 CHLORIDE CONCENTRATION: (PPM)
72
73
74
75
76
77
78
79
80
81
82
Internal Ctrl. No.: 461116-100106-43436-0018

GARRAF FINAL DEVELOPMENT PLAN (GFDP)

Document No.: GFDP-204-52-MC-DS-02-018


Revision : 1

Page : 4 of 7
1
Data Sheet for Closed Drain Pump for Phase-1
2

3 CONSTRUCTION SURFACE PREPARATION AND PAINT


4 ROTATION: (VIEWED FROM COUPLING END) CW CCW MANUFACTURER'S STANDARD OTHER (SEE BELOW)
5 PUMP TYPE: (4.1) (Note-10) SPECIFICATION NO. GFDP-COM-52-PP-SP-GE-003
6 VS1 VS2 VS3 VS4 VS5 VS6 VS7 PUMP:
7 CASING MOUNTING : PUMP SURFACE PREPARATION
8 SUMP COVER PLATE PRIMER
9 CENTRE LINE SEPARATE MOUNTING PLATE (8.3.8.3.1) FINISH COAT
10 SEPARATE SOLE PLATE (8.3.8.3.3)
11 CASING SPLIT: BASEPLATE: (6.3.17)
12 AXIAL RADIAL BASEPLATE SURFACE PREPARATION
13 CASING TYPE: PRIMER
14 SINGLE VOLUTE MULTIPLE VOLUTE DIFFUSER FNISH COAT
15 BETWEEN BEARINGS BARREL DETAILS OF LIFTING DEVICES (6.3.20)
16 CASE PRESSURE RATING: SHIPMENT: (7.4.1)
17 MAX ALLOWABLE WORKING PRESSURE__________________(MPa) DOMESTIC EXPORT EXPORT BOXING REQUIRED
18 @ 83 (*C) OUTDOOR STORAGE MORE THAN 12 MONTHS
19
20 HYDROTEST PRESSURE______________________________(MPa) SPARE ROTOR ASSEMBLY PACKAGED FOR:
21 SUCTION PRESS REGIONS MUST BE DESIGNED SHIPPING CONTAINER PREPARATION (8.2.8.3) VERTICAL STORAGE (8.2.8.2)
22 FOR MAWP (5.3.6) TYPE OF SHIPPING PREPARATION N2 PURGE (8.2.8.4)
23 NOZZLE CONNECTIONS : (5.4.2) (Note-9) HEATING AND COOLING
24 SIZE (DN) FLANGE FACING POSITION HEATING JACKET REQ'D. (5.8.9) COOLING REQ'D
25 RATING COOLING WATER (C.W.) PIPING PLAN (6.5.3.1) __________________
26 SUCTION BY VENDOR Bottom C.W. PIPING:
27 DISCHARGE BY VENDOR 300 # RF PIPE TUBING FITTINGS
28 BALANCE DRUM C.W. PIPING MATERIALS:
29 PRESSURE CASING AUX. CONNECTIONS: (5.4.3) S. STEEL C. STEEL GALVANIZED
30 NO. SIZE (DN) TYPE COOLING WATER REQUIREMENTS:
31 BEARING HOUSING __________(m3/h) @ __________ (MPa)
32 DRAIN HEAT EXCHANGER __________(m3/h) @ __________(MPa)
33 VENT STEAM PIPING : TUBING PIPE
34 PRESS GAUGE BEARINGS AND LUBRICATION (Note -17)
35 TEMP. GAUGE BEARING (TYPE / NUMBER) (5.10.1)
36 WARM-UP RADIAL ANTIFRICTION /
37 BALANCE / LEAK-OFF THRUST ANTIFRICTION /
38 MACHINED AND STUDDED CONNECTIONS (5.4.3.8) LUBIRICATION (5.11.3,5.11.4):
39 CYLINDRICAL THREADS REQUIRED (5.4.3.3) GREASE OIL PURGE OIL MIST PURE OIL MIST
40 COMPONENT BALANCE TO ISO 1940 G2.5 (5.9.4.4) CONSTANT LEVEL OILER PREFERENCE (5.10.2.2) : _______________________
41 SHRINK FIT - LIMITED MOVEMENT IMPELLERS (8.2.2.3) PRESSURE LUBE SYS. ISO 10438-3 ISO 10438-2 (8.2.6.1/8.2.6.5)
42 COUPLINGS: (6.2.2) (Note -18) OIL VISC. ISO GRADE __________________________________________________
43 MANUFACTURER __________________________ MODEL _______ OIL PRESS. TO BE GREATER THAN COOLANT PRESSURE
44 RATING (kW per 100 r/MIN ________________ REVIEW AND APPROVE THRUST BEARING SIZE [(8.2.5.2.d)]
45 SPACER LENGTH _______ (mm) SERVICE FACTOR 1.5 OIL HEATER REQUIRED : STEAM ELECTRIC
46 DRIVER HALF-COUPLING MOUNTED BY: INSTRUMENTATION (6.4.2)
47 PUMP MFR. DRIVER MFR. PURCHASER SEE ATTACHED API 670 DATA SHEET
48 COUPLING WITH HYDRAULIC FIT (6.2.10) ACCELEROMETER(S) (6.4.2.1) _______________________________________
49 COUPLING BALANCED TO ISO 1940-1 G6.3 (6.2.3) PROVISION FOR VIBRATION PROBES (6.4.2.2)
50 COUPLING PER ISO 14691 (6.2.4) RADIAL _________PER BRG. AXIAL _________ PER BRG.
51 COUPLING PER ISO 10441 (6.2.4) PROVISION FOR MOUNTING ONLY (5.10.2.11)
52 COUPLING PER API 671 (6.2.4) FLAT SURFACE REQ'D (5.10.2.12)
53 NON-SPARK COUPLING GUARD (6.2.14c) RADIAL BEARING METAL TEMP. THRUST BRG METAL TEMP.
54 COUPLING GUARD STANDARD PER _______________ (6.2.14a) TEMP. GAUGES (WITH THERMOWELLS) _______________________________
55 BASEPLATES: MONITORS AND CABLES SUPPLIED BY (6.4.2.4)________________________
56 API BASEPLATE NUMBER___________________________(ANNEX D) REMARKS: The Instrumentation required for safe operation of the
57 NON-GROUT CONSTRUCTION (6.3.13) pump shall be recommended and provided by VENDOR.
58 OTHER___________________________________________ MASSES (kg)
59 MECHANICAL SEAL: (5.8.1) PUMPS BASEPLATE
60 Refer (Note 21) DRIVER MOUNTING PLATE
61 GEAR TOTAL
62 COUPLING
63 MOTOR MOUNTING
64 STOOL
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
Internal Ctrl. No.: 461116-100106-43436-0018

GARRAF FINAL DEVELOPMENT PLAN (GFDP)

Document No.: GFDP-204-52-MC-DS-02-018


Revision : 1

Page : 5 of 7
1
Data Sheet for Closed Drain Pump for Phase-1
2

3 SPARE PARTS (TABLE 18) QA INSPECTION AND TESTING


4 START-UP NORMAL MAINTENANCE TEST NON-WIT WIT OBSERVE
5 SPECIFY HYDROSTATIC (7.3.2)
6 PERFORMANCE ( 7.3.3)
7 OTHER PURCHASER REQUIREMENTS NPSH (7.3.4.2)
8 COORDINATION MEETING REQUIRED (9.1.3) RETEST ON SEAL L'KGE (7.3.3.2d)
9 MAXIMUM DISCHARGE PRESSURE TO INCLUDE (5.3.2) RETEST REQUIRED AFTER FINAL
10 MAXIMUM RELATIVE DENSITY HEAD ADJUSTMENT (7.3.3.5b)
11 MAX DIA. IMPELLERS AND/OR NO. OF STAGES COMPLETE UNIT TEST (7.3.4.3)
12 OPERATION TO TRIP SPEED SOUND LEVEL TEST (7.3.4.4)
13 CONNECTION DESIGN APPROVAL (5.12.3.4/8.2.1.4) CLEANLINESS PRIOR TO
14 INERT GAS INHIBITED STORAGE -SPARE CARTRDGE (8.2.8.4) FINAL ASSEMBLY (7.2.2.2)
15 TORSIONAL ANALYSIS REQUIRED (5.9.2.1) NOZZLE LOAD TEST (6.3.6)
16 TORSIONAL ANALYSIS REPORT (5.9.2.6) CHECK FOR CO-PLANAR
17 PROGRESS REPORT (9.3.3) MOUNTING PAD SURFACES (6.3.3)
18 OUTLINE OF PROCEDURES FOR OPTIONAL TESTS (9.2.5) MECHANICAL RUN UNTIL OIL
19 ADDITIONAL DATA REQUIRING 20 YEARS RETENTION (7.2.2.1f) TEMP. STABLE (7.3.4.7.1)
20 LATERAL ANALYSIS REQUIRED (8.2.4.1/8.2.4.1.3) 4 h MECHANICAL RUN AFTER
21 PIPING AND APPURTENANCES OIL TEMP. STABLE (7.3.4.7.3)
22 DYNAMIC BALANCE ROTOR (8.2.4.2) 4 h MECHANICAL RUN TEST (7.3.4.7.2)
23 MANIFOLD PIPING TO SINGLE CONNECTION (6.5.1.6) TRUE PEAK VELOCITY DATA (7.3.3.4d)
24 VENT DRAIN COOLING WATER BRGHSG RESONANCE TEST (7.3.4.6)
25 MOUNT SEAL RESEVOIR OFF BASEPLATE (6.5.1.4) REMOVE / INSPECT
26 FLANGES REQUIRED IN PLACE OF SOCKET WELD UNIONS (6.5.2.8) HYDRODYNAMIC BEARINGS
27 CONNECTION BOLTING AFTER TEST(8.2.7.5)
28 PTFE COATING ASTM A153 GALVANIZED AUXILIARY EQUIPMENT TEST (7.3.4.5)
29 PAINTED SS CHARPY TEST (EN 13445 / ASME VIII)
30 INSTALLATION LIST IN PROPOSAL (9.2.3L) MINIMUM SUBMERGENCE TEST
31 QA INSPECTION AND TESTING DIMENSIONAL CHECK
32 SHOP INSPECTION (7.1.4) VIBRATION TEST
33 PERFORMANCE CURVE APPR. ROTOR DYNAMIC BALANCING
34 TEST WITH SUBSTITUTE SEAL (7.3.3.2) IMPELLER SPIN TEST
35 MATERIAL CERTIFICATION REQUIRED (5.12.1.8) POST TEST INSPECTION
36 CASING IMPELLER SHAFT
37 OTHER TO BS EN 10204, 3.1 TYPE VENDOR KEEP REPAIR AND HT RECORDS (7.2.1.1c)
38 VENDOR SUBMIT TEST PROCEDURES (7.3.1.2 / 9.2.5)
39 CASTING REPAIR PROCEDURE APPROVAL REQ'D (5.12.2.5) VENDOR SUBMIT TEST DATA WITHIN 24 HOURS (7.3.3.3e)
40 INSPECTION REQUIRED FOR CONNECTION WELDS (5.12.3.4e) INCLUDE PLOTTED VIBRATION SPECTRA (5.9.3.3)
41 MAG. PARTICLE LIQUID PENETRANT COMPLETION OF INSPECTION CHECK LIST (7.1.6)
42 RADIOGRAPHIC ULTRASONIC SUBMIT INSPECTION CHECKLIST (7.1.6)
43 INSPECTION REQUIRED FOR CASTING (7.2.1.3)(5.12.1.5)
44 MAG. PARTICLE LIQUID PENETRANT
45 RADIOGRAPHIC ULTRASONIC
46 HARDNESS TEST REQUIRED (7.2.2.3) Wear rings
47 ADDITIONAL SURFACE / SUBSURFACE EXAMINATION (7.2.1.3)
48 FOR _________________________________________
49 METHOD _____________________________________
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
Internal Ctrl. No.: 461116-100106-43436-0018

GARRAF FINAL DEVELOPMENT PLAN (GFDP)

Document No.: GFDP-204-52-MC-DS-02-018


Revision : 1

Page : 6 of 7
1
Data Sheet for Closed Drain Pump for Phase 1
2

3 NOTES INFORMATION BELOW TO BE COMPLETED: BY PURCHASER BY MANUFACTURER BY MANUFACTURER OR PURCHASER


4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37 NOTE-29
38 Closed drain drum parameters
39 Closed Drain Drum I/D (D) for Pump P-6411 A and P-6411 B: 1400 mm
40 Closed Drain Drum Nozzle projection (P) for Pump P-6411 A and P-6411 B: 1450 mm Hold (Note-26)
41 Closed Drain Drum I/D (D) for Pump P-6411 C: 1700 mm
42 Closed Drain Drum Nozzle projection (P) for Pump P-6411 C 1300 mm Hold (Note-26)
43
44 Closed drain Pump parameters
45 HLL (Liquid Level High) = 1150 mm (For V-6411 A/B)
46 HLL (Liquid Level High) 1450 mm (For V-6411 C)
47 LLL (Liquid Level Low) = 350 mm
48 LLLL (Liquid Level Low Low) = 250 mm
49
50 H = VTA mm
51 C = VTA mm
52 M = VTA mm
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
Internal Ctrl. No.: 461116-100106-43436-0018

GARRAF FINAL DEVELOPMENT PLAN (GFDP)

Document No.: GFDP-204-52-MC-DS-02-018


Revision : 1

Page : 7 of 7
1
Data Sheet for Closed Drain Pump for Phase-1
2
3
4 NOTES:
5
6 1. Pump VENDOR to complete all missing data.
7 2. Pumps shall be as per API 610 11 th Edition and Specification for Vertical Centrifugal Pump-Process service (Doc no GFDP-COM-52-MC-SP-GE-014).
8 3. Tag numbers,Quantity & reference P&ID are as follows :
9 Quantity
Wellpad & WC Tag No. Pump Tag nos Motor Tag nos Reference P&ID No. Remarks
10 (Nos)
11 Wellpad D Closed Drain Pump 04-P-6411A / B / C 04-PM-6411A / B / C 3 GFDP-204-52-PRS-DW-16-01-043 (Sht 1& Sht 2) Note-4
12 Wellpad E Closed Drain Pump 05-P-6411A / B / C 05-PM-6411A / B / C 3 GFDP-204-52-PRS-DW-16-01-056 (Sht 1& Sht 2) Note-4
13 WC-1 Closed Drain Pump 15-P-6411 C 15-PM-6411C 1 GFDP-204-52-PRS-DW-16-01-006 (Sht 2 of 2) Note-4
14 WC-2 Closed Drain Pump 12-P-6411 C 12-PM-6411 C 1 GFDP-204-52-PRS-DW-16-01-017 (Sht 2 of 2) Note-4
15 4. In Wellpad D & E location, pumps P-6411 A /B /C shall be installed in Vessels V-6411 A /B /C respectively and in Wellcluster -1 & 2 location, pump
16 P-6411 C shall be installed in Vessel V-6411 C. Hence total installed pumps shall be 8. One common ware house pump with motor
17 will be provided for the above pumps for Phase-1.
18 5. The pump shall be suitable to handle dirty services.
19 6. The indicated discharge pressure is at the delivery flange. Pump VENDOR shall take into considerations pump shaft length, line losses to arrive at the
20 rated pump discharge conditions.
21 7. NPSHA shall exceed the NPSH3 by at least 1 m (3 ft) throughout the range from minimum continuous stable flow up to and including the rated capacity,
22 and by 0.3 m (1 ft) at the lessor of, 120 % of best efficiency flow and maximum system capacity.
23 8. Pump VENDOR to furnish pump performance curve(s) along with the bid duty point duly marked, showing H, Q, NPSHR, BKW / Efficiency.
24 9. The corrosion allowance for Pump Casing shall be 3 mm.
25 10. Pump VENDOR shall provide Vertical centrifugal submerged pump for the furnished duty.(VS1 Design estimated, Pump VENDOR to confirm)
26 11. Pump VENDOR to decide the pump length based on Closed drain drum dimensions and also select minimum submergence above the vessel
27 bottom required for pump operation. Pump shaft length shall be selected to ensure evacuation of the vessel upto low low liquid level.
28 12. Downstream design pressure is 35 barg and design temperature is 83 oC. Shut-off pressure including pump maximum suction pressure and including all tolerances
29 shall not exceed this value of downstream design pressure.
30 Maximum allowable working pressure of the pump to be indicated by Pump VENDOR.As a minimum,same shall be in excess of above downstream pressure.
31 13. Pump is in sour service, hence all parts in contact with the pumped fluid shall be as per NACE STD MR-0175/ISO 15156.
32 Maximum H2S content of 100 ppm(w) shall be considered for design purpose.
33 14. Make of the motor shall be as per COMPANY approved VENDOR list.
34 15. Motor kW rating shall be selected for end of curve operation of pump and as per Clause 4.5 of Specification for Vertical Centrifugal Pump-Process service.
35 16. The electric motor shall be designed in accordance with the Specification for Induction Motor (Doc no GFDP-COM-52-ELE-SP-GE-006).
36 17. Line shaft intermediate bearing shall be lubricated using pumped liquid.
37 18. Pump VENDOR to provide non-sparking guard.Coupling shall be sourced from the COMPANY approved Coupling VENDOR list.
38 19. Pumps to be auto start on high level. Pump VENDOR to consider open discharge start-up of the pump.
39 20. Pump VENDOR to design and furnish critical loads for all load cases for support pedestal design.
40 21. Single mechanical seal shall be provided for each pump. Same shall be as API 682 latest edition. Seal plan shall be Plan 13,61.
41 22. Gasket material shall be Spiral Wound, Graphite filled, SS316 Winding, SS 316 Inner Ring / CS Centering Ring, ASME B16.20.
42 23. Pumping liquid contains sludge with sand particles size of 100 microns. Pump VENDOR shall consider this requirement during design of impeller
43 & suction strainer ( to be included in Pump VENDOR scope).
44 24. Mounting plate with associated gasket and bolting shall be provided by Pump VENDOR.
45 25 All auxiliaries and accessories shall be sourced from approved VENDOR with prior approval from COMPANY in writing.
46 26. Pump mounting nozzle projection from Vessel centerline shall be confirmed by EPC CONTRACTOR during detail engineering. Pump shaft length
47 from suction flange to discharge flange shall be identical for wellpad and wellcluster - 1 & 2.
48 27 VENDOR to consider the corrosive components properties CO2 = 0.3 %, H2S=100 ppm and Chloride =103.7 gm/lts.
49 28 Density and Viscosity figures specified on page 3 are that corresponds to respective temperature.
50 29 The Closed drain drum / pump parameters specified on page 6 are preliminary and to be verified and confirmed by EPC Contractor during detail engineering.
51
52
53
54 Legends
55 VTA: Pump VENDOR to advise
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79