Three Phase String Inverter(LV)
SUN-10K-G03-LV SUN-12/15K-G02-LV
SUN-10/12/15/18/20/21K-G04-LV
120V/208V, 127V/220V, 133V/230V and
50/60Hz, Three phase system
2 MPP trackers, Max. efficiency up to 98.6%
Zero export application, VSG application
String intelligent monitoring (optional)
Wide output voltage range
Anti-PID function (Optional)
Stock Code: 605117.SH
Technical Data www.deyeinverter.com
SUN-10K SUN-12K SUN-15K SUN-10K SUN-12K SUN-15K SUN-18K SUN-20K SUN-21K
Model -G03-LV -G02-LV -G02-LV -G04-LV -G04-LV -G04-LV -G04-LV -G04-LV -G04-LV
Input Side
Max. DC Input Power (kW) 13 15.6 19.5 13 15.6 19.5 23.4 26 27.3
Max. DC Input Voltage (V) 800
Start-up DC Input Voltage (V) 250
MPPT Operating Range (V) 200-700
Max. DC Input Current (A) 32+32 32+32 40+40
Max. Short Circuit Current (A) 48+48 48+48 60+60
No.of MPP Trackers 2 2 2
No.of Strings per MPP Tracker 3+3 2+2 3+3
Output Side
Rated Output Power (kW) 10 12 15 10 12 15 18 20 21
Max. Active Power (kW) 11 13.2 16.5 10 12 15 18 20 21
3L/N/PE 127V/220V 0.85Un-1.1Un 3L/N/PE 120V/208V, 127V/220V, 133V/230V
Rated Output Voltage/Range (V)
(this may vary with grid standards) 0.85Un-1.1Un (this may vary with grid standards)
Rated Grid Frequency (Hz) 60 50/60
Operating Phase Three Phase
Rated AC Grid Output Current (A) 26.2 31.5 39.4 27.8/26.3/25.1 33.4/31.5/30.1 41.7/39.4/37.6 50/47.3/45.2 55.6/52.5/50.2 58.4/55.2/52.7
Max. AC Output Current (A) 28.9 34.6 43.3 27.8/26.3/25.1 33.4/31.5/30.1 41.7/39.4/37.6 50/47.3/45.2 55.6/52.5/50.2 58.4/55.2/52.7
Output Power Factor 0.8 leading to 0.8 lagging
Total Harmonics Current Distortion (THDi) <3%
DC Injection Current (mA) <0.5%
Efficiency
Max. Efficiency 98.6%
Euro Efficiency 98%
MPPT Efficiency >99%
Protection
DC Reverse-Polarity Protection Yes
AC Short Circuit Protection Yes
AC Output Overcurrent Protection Yes
Output Overvoltage Protection Yes
Insulation Resistance Protection Yes
Ground Fault Monitoring Yes
Anti-islanding Protection Yes
Temperature Protection Yes
Integrated DC Switch Yes
Remote Software Upload Yes
Remote Change of Operating Parameters Yes
Surge protection DC Type II / AC Type II
General Data
Cabinet Size (WxHxD mm) 362×577×215 (Excluding Connectors and Brackets)
Weight (kg) 23
Topology Transformerless
Internal Consumption <1W (Night)
Running Temperature -25-65℃, >45℃ Derating
Ingress Protection IP65
Noise Emission (Typical) ≤40 dB ≤50 dB
Cooling Concept Smart Cooling
Permissible Altitude (m) 2000
Warranty 5 Years
Grid Connection Standard NBR 16149, NBR 16150, EN 50549, RD 140
Operating Surroundings Humidity 0-100%
Safety EMC / Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Features
Display LCD1602
Interface RS485/RS232/Wifi/LAN
Ningbo Deye Inverter Technology Co., Ltd.
Add: No. 26 South YongJiang Road, Daqi, Beilun, NingBo, Zhejiang, China. | Tel: 0086-0574-86120560 | E-mail:
[email protected]