0% found this document useful (0 votes)
112 views34 pages

Brilnurse Használati Utasítás

This document provides safety information and instructions for use of a nerve and muscle stimulator device. It describes how transcutaneous electrical nerve stimulation (TENS) and electrical muscle stimulation (EMS) work to relieve pain and stimulate muscles. The document provides extensive details on proper use, contraindications, warnings, and maintenance of the device.

Uploaded by

Ágnes Iványi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
112 views34 pages

Brilnurse Használati Utasítás

This document provides safety information and instructions for use of a nerve and muscle stimulator device. It describes how transcutaneous electrical nerve stimulation (TENS) and electrical muscle stimulation (EMS) work to relieve pain and stimulate muscles. The document provides extensive details on proper use, contraindications, warnings, and maintenance of the device.

Uploaded by

Ágnes Iványi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 34

Nerve Muscle Stimulators

FM-B2404/PRO15AB

+ M
+
V

- T
-

Pain Relief Anywhere and Anytime


http://www.brilnurse.com

EXTENT YOUR WARRANTY TO 2 YEARS & GET SPARE PADS

Register within 2 weeks after receiving your tens unit!

Visit link or scan the QR code & Complete registration

http://www.brilnurse.com

CUSTOMER SERVICE
If you have any problem, please be free to contact us!

[email protected]
http://www.brilnurse.com
@brilnurse

[email protected]
http://www.brilnurse.com

Table of contents
1. SAFETY INFORMATION 01
1.1 General Introduction 01
1.2 Medical Background 01
1.3 Intended for Use 03
1.4 Contraindications 03
1.5 Warnings, Cautions, and Adverse Reactions 04
1.6 Patient Population 08
1.7 Potential Electromagnetic and Other Interference 08
1.8 Explanation of figures, symbols, warning statements
and abbreviations on the device 09
2. DEVICE PRESENTATION 10
2.1 Illustration of the Device 10
2.2 Illustration of the Accessories 16
3 SPECIFICATION 16
4 INSTRUCTIONS FOR USE 16
5 CLEANING AND CARE 22
5.1 Tips for Skin Care 22
5.2 Cleaning the Device 23
5.3 Electrodes 23
5.4 Cleaning the Electrode’s Cords 24
5.5 Maintenance 24
6 TROUBLE SHOOTING 27
7 RECOMMEND USE POSITION 29

[email protected]
http://www.brilnurse.com

1. SAFETY INFORMATION
1.1 General Introduction
Thank you very much for using our Nerve Muscle Stimulator. For
you use this device safely, please read this user manual
carefully before your first use.
Please keep this user manual with your device for future
reference.
This device is a portable electrotherapy device, featuring two
therapeutic modes: Transcutaneous Electrical Nerve Stimulator
(TENS) and Electrical Muscle Stimulation (EMS), which are
used for pain relief and electrical muscle stimulation. The
stimulator sends gentle electrical current to underlying nerves
and muscle group via electrodes applied on the skin. The
parameters of the device are controlled by the buttons on the
touch screen panel. The intensity level is adjustable according
to the needs of the individual user.

1.2 Medical Background


EXPLANATION OF TENS
Transcutaneous Electrical Nerve Stimulation (TENS) is a
noninvasive, drug free method of controlling pain. TENS uses
tiny electrical impulses sent through the skin to nerves to modify
your pain perception. TENS does not work for everyone.
However, in most patients it is effective in reducing or eliminat-
ing the pain, allowing for a return to normal activity.
HOW TENS WORKS
The TENS unit sends comfortable impulses through the skin that
stimulate the nerve (or nerves) in the treatment area. In many
cases, this stimulation will greatly reduce or eliminate the pain
sensation the patient feels. Pain relief varies by individual
patient, mode selected for therapy, and the type of pain. In many
patients, the reduction or elimination of pain lasts longer

01 [email protected]
http://www.brilnurse.com

than the actual period of stimulation (sometimes as much as


three to four times longer). In others, pain is only modified while
stimulation actually occurs.

EXPLANATION OF EMS
Electrical Muscle Stimulation (EMS) is an internationally
accepted and proven way of treating muscular injuries. It works
by sending electronic pulses to the muscle needing treatment;
this causes the muscle to exercise passively. This device has
low frequency and in conjunction with the square wave pattern
allows direct work on muscle groupings. This is widely used in
hospitals and sports clinics for the treatment of muscular injuries
and for the reeducation of paralyzed muscles, to prevent
atrophy in affected muscles and improving muscle tone and
blood circulation.

HOW EMS WORKS


The EMS units send comfortable impulses through the skin that
stimulate the nerves in the treatment area. When the muscle
receives this signal, it contracts as if the brain has sent the
signal itself. As the signal strength increases, the muscle flexes
as in physical exercise. When the pulse ceases, the muscle
relaxes and this cycle is repeated until therapy is completed.
The goal of electrical muscle stimulation is to achieve
contractions or vibrations in the muscles. Normal muscular
activity is controlled by the central and peripheral nervous
systems, which transmit electrical signals to the muscles. EMS
works similarly but uses an external source (the stimulator) with
electrodes attached to the skin for transmitting electrical
impulses into the body. The impulses stimulate the nerves to
send signals to a specifically targeted muscle, which reacts by
contracting, just as it does with normal muscular activity.

02 [email protected]
http://www.brilnurse.com

1.3 Indication for use (IFU)


TENS:
The device is designed to be used for temporary relief of pain
associated with sore and aching muscles in the shoulder, waist,
back, neck, upper extremities (arm), lower extremities (leg),
abdomen and bottom due to strain from exercise or normal
household work activities.
EMS:
The device is designed to be used to stimulate healthy muscles
in order to improve or facilitate muscle performance:
IMPORTANT SAFETY INFORMATION
Read instruction manual before operating. Be sure to comply
with all “Contraindications”, Warnings”, “Cautions” and “Adverse
reactions” in the manual. Failure to follow instructions may
cause harm to user or device.

1.4 Contraindications
1) This device should not be used for symptomatic local pain
relief unless etiology is established or unless a pain syndrome
has been diagnosed.
2) This device should not be used when cancerous lesions are
present in the treatment area.
3) Stimulation should not be applied over swollen, infected,
inflamed areas or skin eruptions (e.g., phlebitis, thrombophlebi-
tis, varicose veins, etc.).
4) Electrodes must not be applied to sites that might cause
current/stimulation to flow through the carotid sinus region
(anterior neck) or trans-cerebrally (through the head).
5) Patients with an implanted electronic device, such as a
cardiac pacemaker, implanted defibrillator, or any other metallic
or electronic device should not use this device without first
consulting a doctor.

03 [email protected]
http://www.brilnurse.com

6) This device should not be used over poorly enervated areas.


7) This device should not be used on patients with serious
arterial circulatory problems in the lower limbs.
8) This device should not be used on patients with abdominal or
inguinal hernia.
9) Patients with heart disease, epilepsy, cancer or any other
health condition should not use this device without first
consulting a physician.

1.5 Warnings, Cautions, and Adverse Reactions


Warnings
1.Apply stimulation only to normal, intact, clean, healthy skin.
2.Do not apply stimulation when in the bath or shower.
3.Do not apply stimulation while sleeping.
4.Do not use this device during pregnancy unless directed by
your physician.
5.Stimulation should not be applied over the neck, mouth or
eyes. Severe spasm of the laryngeal and pharyngeal muscles
may occur, and the contractions may be strong enough to close
the airway or cause difficulty in breathing.
6.Stimulation should not be applied across the chest in that the
introduction of electrical current into the heart may cause
cardiac arrhythmias.
7.Stimulation should not be applied across the head.
8.Stimulation should not be applied over the carotid sinus nerve,
particularly in patients with a known sensitivity to the carotid
sinus reflex.
9.Replacement of a component could result in an unacceptable
risk. Please contact us if you have any problem with the device.
10.Keep this device out of the reach of infants, toddlers, and
children.

04 [email protected]
http://www.brilnurse.com

11.Do not recharge, use or leave the battery and device in any
high temperature environment such as a location near fire or in
direct sunlight. Doing so may cause the battery to overheat,
ignite or rupture.
12.There is potential hazard from simultaneous connection of a
patient to a high frequency surgical equipment and the
stimulator that may result in burns and possible damage to the
stimulator.
13.Operation in proximity (e.g. 1 m) to a shortwave or
microwave therapy equipment may produce instability in the
stimulator output.
14.When the device is transferred to another patient,replace
used pads with new pads.
15.Please avoid the use of the equipment as much as possible
in the following occasions or conditions, as it may result in
incorrect operation: talking on a mobile phone; near the signal
emission base station for broadcasting, television, communica-
tion, radar, navigation, etc.; near active HF SURGICAL
EQUIPMENT and the RF shielded room of an ME SYSTEM for
magnetic resonance imaging.
16.Use of accessories, transducers and cables other than those
specified or provided by the manufacturer of the equipment
could result in increased electromagnetic emissions or
decreased electromagnetic immunity of this equipment and
result in improper operation.
17.Portable RF communications equipment (including peripher-
als such as antenna cables and external antennas) should be
used no closer than 30 cm (12 inches) to any part of the
equipment including cables specified by the manufacturer.
Otherwise, degradation of the performance of this equipment
could result.
18.The device delivers a current density 0.612 mA/cm2, In order
to mitigate potential adverse events:

05 [email protected]
http://www.brilnurse.com

1)Please do not turn on the device before connecting the wires,


electrode pads, device and body.
2)The electrode pads have been pasted to the appropriate part,
and the mainframe and wire have been properly connected
before it can be turned on.
3)During normal use, do not touch the hydrogel on the electrode
pads, do not pull out the wire plug, do not pull out the electrode
pads. All these actions must be performed after shutting down.

Cautions
1. This device is for single patient use only.
2. Keep yourself informed of the contraindications.
3. This device is not intended for use on an unattended patient
who is noncompliant, emotionally disturbed, has dementia, or a
low IQ.
4. This device should not be used while driving, operating
machinery, close to water or during any activity in which
involuntary muscle contractions may put the user at undue risk
for injury.
5. Never use the device in rooms where aerosols (sprays) are
used or pure oxygen is being administered.
6. Do not use this device at the same time as other equipment
which sends electrical pulses to your body.
7. Do not confuse the electrode cables and contacts with your
headphones or other devices, and do not connect the electrodes
to other devices.
8. Do not use sharp objects such as pencil point or ballpoint pen
to operate the buttons on the control panel.
9. Inspect applicator cables and associated connectors before
each use.
10. Turn the device off before applying or removing the
electrodes.

06 [email protected]
http://www.brilnurse.com

11. Electrical stimulators should be used only with the leads and
electrodes recommended for use by the manufacturer.
12. Do not use it in the presence of explosive atmosphere or
flammable mixture.

Adverse Reactions
1. Potential allergic reactions due to the electrical stimulation or
gel including skin irritation, redness, burning or hypersensitivity.
If skin irritation occurs, discontinue use and consult your
physician.
2. Discomfort occurs due to improper stimulation levels, reduce
the stimulation intensity or turn the device off directly.
3. Headache and other painful sensations during or following the
application of electrical stimulation near your eyes, to your head
and face.

*** You should stop using the device and consult with your
physician if you experience any adverse reactions from the
device. ***

Notes
1. Please note that the original recognized accessories,
detachable parts and material which are approved by standard.
2. Please note that the adapter you choose for battery charging
must complies with ANSI/AAMI/ES60601-1 or IEC 60950
standards.

07 [email protected]
http://www.brilnurse.com

1.6 Patient Population


The “Patient” is an intended user.
Adults who suffer from sore and aching muscles in the shoulder,
waist, back, neck, upper extremities (arms), and lower extremities
(leg) due to strain from exercise or normal household work
activities can use this Device.
However, it should not be used by children, pregnant women, or
anyone who has an implanted metallic or electronic device. Ask
your physician if you have any questions related to your health.

Notes
1. This part is about the safety information. It is intended to help
you use it safely, prevent injury and avoid situation which could
result in damage on the device. It is important for you to read this
information carefully.
2. Please note that the original recognized accessories,
detachable parts and material which are approved by standard.
3. Please note that the adapter you choose for battery charging
must complies with ANSI/AAMI/ES60601-1 or IEC 60950
standards.

1.7 Potential Electromagnetic and Other Interference


This product is sensitive to the electromagnetic interference, and
the following cases may interfere with normal use:
● When talking on the mobile phone.
● Near the base station for signal transmission (broadcast,
television, communications, radar, navigation, etc.).
● Near high radiation medical instruments such as nuclear
magnetic resonance.
The operator should be away from the equipment or occasion as
soon as possible if the essential performance of the equipment is
degraded or lost due to EM DISTRUBANCES. The essential
performance of the equipment should be restored. If not, please
contact your local dealer.

08 [email protected]
http://www.brilnurse.com

1.8 Explanation of figures, symbols, warning statements


and abbreviations on the device

Meanings of symbols used for marking described in


instructions for use

Caution!

Type BF applied part

Direct current

Protected against solid foreign objects of 12,5 mm Ø


and greater; Protection against vertically falling water
drops when ENCLOSURE tilted up to 15°

Refer to instruction manual

Serial Number
Manufacture date
Manufacture information

Authorized representative in the European Community

WEEE Label

09 [email protected]
http://www.brilnurse.com

2. DEVICE PRESENTATION
2.1 Illustration of the Device

On/Off switch USB port

Time indicator

Battery indicator

LCD Mode indicator

A/B Intensity indicator

Mode adjustment
A/B / Pause

A Intensity adjustment(+) B Intensity adjustment(+)


Mode select + M
+ Mode select
V

A Intensity adjustment(-)
- T
- B Intensity adjustment(-)

Time adjustment

Output A Output B
A B

ON/Off Switch: When the switch is turned to the "ON" position,


the device is turned on, and when it is turned to the "Off"
position, the device is turned off.
USB Port: AC adapter connecting port, when used for charging,
the interface between the charging cable and the device.

10 [email protected]
http://www.brilnurse.com

Battery Indicator: Used for battery level display. When the


battery is about to run out, a flashing battery symbol will appear
on the display. It should be charged as soon as possible.
However, depending on the settings and intensity level, the
machine may continue to operate for a longer period of time.
Time Indicator: Display the remaining working time after being
ON(Min).
Mode Indicator: There are 24 modes in total, in the middle area
of the display, touch the mode adjustment button, the control
area corresponding to the mode will flash. Then press the mode
select button to select the mode.
There are 12 TENS modes:

There are 12 EMS modes:

11 [email protected]
http://www.brilnurse.com

Icon Mode Name Description

Simulation of Tuina is a
hands-on body treatment
1 Tuina
which help with pain relief and
relaxation

Stimulate pain points in the


2 Hand hand area for pain relief or
muscle relaxation.

It is a type of alternative
medicine consisting of finger
3 Kneading and palm pressure, stretches,
and other massage
techniques.

Stimulate pain points in the


4 Back lumbar area for pain relief or
muscle relaxation.

Stimulating tapping is intended


to produce a hard thumping
sensation that massages your
1 Tapping
muscles, which can give you
an invigorated and revitalized
feeling.

Random combination of basic


modes. Full body relaxation
2 Blend after workout, exercises &
fitness after a hard day
working.

12 [email protected]
http://www.brilnurse.com

Stimulate pain points in the


3 Hip hip, sciatica nerve for pain
relief or muscle relaxation.

Stimulate pain points in the


4 Foot Foot area for pain relief or
muscle relaxation.

Simulation of acupuncture
provides the same sensation
Acupunc- without needles, by utilizing
1 electronic pulses to achieve
ture
the sensation of differing
needle depths.

Combination of acupuncture. It
helps lose weight or tone,
2 Weight strengthen and firm muscles
Loss at abs, back,thighs and arms
etc.

It is the manipulation of
superficial and deeper layers
3 Pressure of muscle and connective
tissue using various
techniques.

Stimulate pain points in the


4 Knee knee area for pain relief and
muscle relaxation.

Stimulate pain points in the


1 Guasha elbow area for pain relief or
muscle relaxation.

13 [email protected]
http://www.brilnurse.com

Stimulate pain points in the


3 Hip lumbar area for pain relief or
muscle relaxation.

Shiatsu is simulation of a type


4 Foot of finger and palm pressure,
stretches, and other massage
techniques.

Stimulating with a low


Acupunc- frequency setting provides the
1 user with a scratching and
ture
kneading sensation.

Mimic the sensation of suction


created on the skin. Cupping
is a traditional Chinese
1 Cupping therapy in which heated glass
cups are applied to the skin,
creating suction as a way of
stimulating the flow of energy.

Mimic the sensation of suction


created on the skin. Cupping
is a traditional Chinese
2 Shoulder therapy in which heated glass
cups are applied to the skin,
creating suction as a way of
stimulating the flow of energy.

Stimulate pain points in the


3 Elbow elbow area for pain relief or
muscle relaxation.

14 [email protected]
http://www.brilnurse.com

Stimulate pain points


specifically in the ankle for
4 Ankle
pain relief or muscle
relaxation.

Combina- Random combination of basic


1
tion modes

Deep tissue massage therapy


is similar to Swedish
Deep
massage, but the keeper
2 Tissue
pressure is beneficial in
Massage
releasing chronic muscle
tension.

It helps muscle reduction,


relaxation of muscle spasms,
Fibrillation
3 increase range of motion,
massage
injury recovery post surgery
recovery.

Stimulate pain points in the


4 Reflexolo- body area for pain relief or
gy muscle relaxation.

M Select Button: Mode select button, When the type of mode is


determined (Mode Adjustment), you can select the specific
mode by pressing the M button.
< and > Button: Mode adjustment button, used to select the
type of mode(6 types, please to see the mode indicator).
Intensity Indicator: A and B, A only shows the intensity of A
channel, B only shows the intensity of B channel. When you
repeatedly click the A/B button at the bottom of the device, A or
B Intensity Indicator will switch and flash.

15 [email protected]
http://www.brilnurse.com

+ / - Button: Intensity adjustment button, Select the A channel or


the B channel by the A/B button, to touch once + button, the
strength will increase by one, and touch once – button, the
strength will decrease by one.
A/B Button: A/B channel switch button, the default is channel A
when power on, click the A/B button once to switch to channel B,
click repeatedly to switch repeatedly.
Pause Button: Used to pause the device during use.
T Button: Used to adjust the device working time, the default
time is 30 minutes. User are able to adjust the time from 10
minutes to 90 minutes by the T button. The timer could be
increased by 10 minutes intervals.
A and B: Output A and Output B, are output socket, electrical
signal output after connection of the cable with adhesive
electrodes channel A or channel B.

2.2 Illustration of the Accessories


Features of the Device
● LCD display
● 2 independent channels
● Adjustable timer up to 90 minutes
● 24 different operating modes
● Rechargeable internal polymer bazttery
● 30 level intensity settings
● Allows 2- 4 pads to be applied to the different targeted areas
at the same time
● 2 outputs are isolated, so both channel A and channel B has
the same 100% power
● Applied part: self-adhesive electrode pads

Important Information
Degraded sensors and electrodes, or loosened electrodes, can
degrade performance or cause other unsafe issues.

16 [email protected]
http://www.brilnurse.com

Included in this package


● Tens Device × 1pc
● Oval pads × 2 pcs
● Palm pads × 6 pcs
● Rectangular pads × 2 pcs
● Electric wire × 2 pcs
● USB cable × 1 pc
● Instruction manual × 1pc
● lanyard × 1pc
● Storage Bag × 1pc

3. SPECIFICATION
Power
Input voltage: DC5V
Rated current: ≤ 50mA
Rated power: ≤ 0.25W
Li-ion battery:3.7 V dc

4. INSTRUCTIONS FOR USE


How to Use the Device

1.Environmental operating conditions: Temperature: -5 ~ +40°C


Humidity: Does not exceed 85% Atmospheric pressure range of
800 hPa to 1 060 hPa
2.Please make sure the device is on the OFF position when
setting up the unit, adjusting the pads, or making a new
connection.
3.Do not turn on the device before you place pads on your skin.

17 [email protected]
http://www.brilnurse.com

Before using the device, please check following carefully:


1.Check the electrode wires for any damages or irregularities.
2.Check the electrode pads for any damages or irregularities.
3.Check for any physical damage on the unit.

Step 1: Connect the electrode to the device


The FM-B2404 is equipped with two isolated channels A&B.
This will allow you to set separate modes and separate
intensities on each channel using the 2 outputs A, B. Before
connecting the wires to the unit, decide which channel you wish
to use (channel A or B). To use A channel only, connect the
electrode wire(s) to outputs A. To use B channel only, connect
the electrode wire(s) to outputs B. To use both A, B channels,
connect the electrode wires to all outputs.
1.Plug the electrode wire into the output located at the bottom of
the device.
2.Ensure that the electrode wires are fully inserted into the
output and secured. Make sure the wires are not loose. A loose
connection will lower the power output of your device, potentially
causing unreliable connection.
3.Repeat 1 & 2 to connect another wire.

CAUTION:
Do not insert the plug of the patient lead wire into any AC power
supply socket.

Step 2: Connect the electrode pads to the wires


1.Each wire has two leads with pin-in connectors. Insert the wire
connectors into the pads. Make sure that at least one pair (2
pieces) of pads is attached to the same wire. One pad alone will
not work.
2.Make sure at least one pair of pads is attached to the same
wire.
3.Check the connections to ensure they are fastened.

18 [email protected]
http://www.brilnurse.com

CAUTION:
1.Please make sure the device is on the OFF position when
setting up the unit, adjusting the pads, or making a new
connection.
2.DO NOT turn on the unit before you put pads on your skin.
3.Use at least one pair of pads. One pad alone will not work.
Step 3: Place Electrodes on Skin
1.Remove the plastic films on the pads.
2.Check if the adhesive side of on the pad is clean after
removing the plastic film.
3.Place pads on the muscle you wish to treat. Make sure your
skin has been cleaned of all dirt, oil, or lotions.
4.Be sure to place the adhesive side of pad on your skin.
5.We recommend keeping the plastic films for storing the pads
after usage.
6.Make sure that you use at least one pair of pads on the same
wire at the same time.
7.Make sure the pads are stick adhered closely on your skin.

CAUTION:
1. Do not overlap pads or place one pad on top of another one.
2. Never remove the self-adhesive electrodes from the skin
while the device is turned on. You will feel an uncomfortable
electrical shock.

Electrode Placement
The placement of electrodes can be one of the most important
parameters in achieving success with this therapy. Of utmost
importance is the willingness of the physician to try the various
styles of electrode placement to find which method best fits the
needs of the individual patient.
Once an acceptable location has been achieved, mark down the
electrode sites and the device settings, so the patient can easily
continue treatment on them.

19 [email protected]
http://www.brilnurse.com

Step 4: Turn on the device


Push the “ON/OFF” switch located on the top of the unit to the
ON position.
Verify the channel indicator on the screen to make sure the
device is on the same channel you wish to use. The “A” letter will
blink to indicate channel A is working. The “B” letter will blink to
indicate channel B is working.

CAUTION:
Before using the device for the first time, you are strongly
advised to take careful note of the contraindications and safety
measures detailed at the beginning of this manual (Safety
information).

Step 5: Select modes and intensity


Once the device is turned ON, it will show all icons for 1 second
to ensure that all icons are displaying properly. The unit will
automatically set to channel A, mode 1, with zero intensity. As
mentioned in the previously, this device is equipped with two
isolated channels A&B. You will need to select the mode and
intensity for the channel you wish to use. You have the option to
use one channel alone or both channels.
There are two therapeutic programs available: TENS and EMS.
The therapeutic mode can be selected by pressing the mode
button.
Select desire mode
1.Press M to select from first icon to the sixth icons;
2.Press < or > to select 1-2-3-4 mode in selected icon;

CAUTION:
Refer to Mode Indicator illustration of the device to confirm what
kinds of mode you choose, TENS or EMS.

20 [email protected]
http://www.brilnurse.com

Adjust Channel Intensity for channel A, use output(s) A:


1.To select the mode, touch any of the TENS modes or EMS modes
displayed on the screen. The selected mode will blink.
2.Press intensity “+” button to increase the intensity. When changing
the mode, the intensity level will automatically reset zero.
3.Keep increasing the intensity by pressing the intensity increase
button to get to the desired level.

Adjust Channel Intensity for channel B, use output(s) B:


1.Press the channel switch button once, to switch to channel B.
The B letter will blink to indicate channel B is working.
2.To select the mode, touch any of the TENS modes or EMS
modes displayed on the screen. The selected mode will blink.
3.Press intensity “+” or “-” button to increase/decrease the
intensity. When changing the mode, the intensity level will
automatically reset zero.
4.Keep increasing the intensity by pressing the intensity
increase button to get to the desired level.

CAUTION:
1. We recommend starting at the lowest level of intensity and
gradually increase to a level that is comfortable.
2. The intensity should be set at a level where you will
experience some muscular vibration and involuntary muscle
movements.
3. If the stimulation levels become uncomfortable, reduce the
stimulation intensity to a comfortable level or turn it off directly.

Step 6: Adjust timer


The timer will increase in the increment of 10. Adjust timer from
10 minutes up to 90. Keep pressing the T button to set to 90
minutes.

Step 7: Pause
Long Press the A/B/Pause button to pause or resume during the
device working.
21 [email protected]
http://www.brilnurse.com

Step 8: Turn off the device


Push the “ON/OFF” switch located at the top of the unit to the
OFF position.

Step 9: Remove the pads from your skin


Lift the corner of the electrode and gently remove it from the
skin, and place them back on the protective plastic film.

Caution
DO NOT remove the pads before you turn off the equipment.

Step 10: Take off the pads from wires. Unplug wires from
device.
Maintain the device in accordance with maintenance requirements.

5. CLEANING AND CARE


5.1 Tips for Skin Care
Follow these suggestions to avoid skin irritation, especially if
you have sensitive skin:
1. Wash the area of skin you will be placing the electrodes on
with soap. Rinse thoroughly and dry the area completely before
and after placing electrodes.
2. Excess hair may be clipped with scissors; do not shave
stimulation area.
3. Many skin problems arise from the “pulling stress” from
adhesive patches that are excessively stretched across the skin
during application. To prevent this, apply electrodes from center
outward; avoid stretching over the skin.
4. To minimize “pulling stress”, tape extra lengths of lead wires
to the skin in a loop to prevent tugging on electrodes.
5. When removing electrodes, always remove by pulling in the
direction of hair growth.

22
[email protected]
http://www.brilnurse.com

6. It may be helpful to rub skin lotion on electrode placement


area during treatment down time when you are not wearing
electrodes.
7. Never apply electrodes over irritated or broken skin.

5.2 Cleaning the Device


1. Remove the battery from the device before you clean the
device.
2. Clean the device after use with a soft, slightly moistened
cloth.
3. Do not use any chemical cleaners or abrasive agents for
cleaning.

5.3 Electrodes
1. Use this device only with the leads and electrodes provided
by the manufacturer.
2. Inspect your electrodes before every use. Replace electrodes
as needed. Reusable electrodes can cause slight skin irritation,
lose adhesion properties and deliver less stimulation if
overused.
3. The ordering information of the electrodes pads: Available for
purchasing on Amazon, or other e-commerce platforms. But it
specifies the manufacturer of the electrode pads, the manufac-
turer is the best choice for you. Be free to contact the seller if
you need.
4. The electrode type: It is a kind of hydrogel and medical
silicone.
5. The type of connector on the electrode: Pin-in.

Warning:
1. The electrode size, shape, and type may affect the safety and
effectiveness of treatment and that a risk associated with use of
the wrong size electrode is thermal burn.
2. We advises you to obtain replacement electrodes that are the
same type, have the same dimensions and same connectors as
those you distribute with your device.

23 [email protected]
http://www.brilnurse.com

TO REMOVE YOUR ELECTRODES:


1. Lift the corner of the electrode and gently remove it from the
skin.
2. It may be helpful to improve repeated electrode application by
spreading a few drops of cold water over the adhesive side and
turn the surface up to air dry. Over saturation with water will
reduce the adhesive properties.
3. Between uses, place the electrodes back onto the protective
sleeve and insert them into the re-sealable bag and store in a
cool dry place.

CAUTION:
1. Do not pull on the electrode wire. Doing so may damage the
wire and electrode.
2. The electrodes should be discarded when they are no longer
adhering to the skin.
5.4 Cleaning the Electrode’s Cords
Clean the electrode cords by wiping them with a damp cloth.
Coating then lightly with talcum powder will reduce tangles and
prolong their life.

5.5 Maintenance
1. Maintenance and all repairs should only be carried out by an
authorized agency. The manufacturer will not be held responsi-
ble for the results of maintenance or repairs by unauthorized
persons.
2. The user must not attempt any repairs to the device or
accessories. Please contact the seller if you have any problems.
3. Opening of the equipment by unauthorized agencies is not
allowed and will terminate any claim to warranty.
4. Check the unit before each use for signs of wear and/or
damage. Replace worn items as required.

24 [email protected]
http://www.brilnurse.com

5. Please clean the main machine frequently. Use a piece of soft


dry cloth to wipe the dirt on the main machine. Don't wash with
water or clean with the detergent, thinner, volatile oil, etc. that
contains chemical substances.
6. The gel surface of the massage pad should be kept clean and
avoid dirt like dust, oily substances, sticky substances, etc.,
otherwise the stickiness will be decreased.
7. Please paste the protective films back onto the pads after
use.
8. When the stickiness of the massage pad becomes weak due
to dirt or if there is a tingling sensation in the skin, please use a
piece of damp cloth dipped in a little water to gently wipe the gel
surface. After drying, the stickiness will recover, but if water is
overused, the stickiness will be decreased.
9. Please don't wipe the gel surface with a paper towel.
10. Please Do not scrape the gel surface with nail, brush, etc.
11. Massage pads are consumables with the service life of
generally 20-30 times. If the pads are not sticky or the stimulator
becomes weak, please change the pads in time.
12. The batteries for this product are built-in polymer batteries.
If it is not used for a long time, please charge it every 6 months.

Safekeeping
1.Please do not put the main machine in the place exposed to
sunlight, high temperature, humidity, lots of dust, or the place
close to fire, easy to vibrate or shock.
2.Please put where children can't reach it.
Cleaning and Storage
Environmental conditions of transport and storage:
Temperature: -20 ~ +60℃,
Humidity: Humidity does not exceed 85%
Use a lightly moistened cloth to clean the device and wipe
gently.

25 [email protected]
http://www.brilnurse.com

● Make sure the device is off when you clean it.


● Do not let water to get into the device.
Cleaning and Storing Pad
Clean: After using pads on your body, please drop a little clean
water on the sticky side and use fingertips to clean it softly.
● Please turn off the device and disconnect the pads with wires
first before you clean the pad.
● Do not use nails or other sharp objects on the sticky side.
● Do not use chemical liquids on sticky side.
Storage: Place plastic film on the sticky side of pad to keep the
gel moisture.

STORAGE
1. For prolonged pauses in treatment, store the device in a cool
dry room and protect it against heat, sunshine and moisture and
remove the battery to avoid battery leaking.
2. Store the device in a cool, well-ventilated place.
3. Never place any heavy objects on the device.

DISPOSAL
Please dispose of the device in accordance with the laws in your
area.

26 [email protected]
http://www.brilnurse.com

6. TROUBLE SHOOTING
If your device does not seem to be operating correctly, refer to
the chart below to determine what may be wrong. Should none
of these measures correct the problem, the device should be
serviced.

PROBLEM CAUSE SOLUTION

One pad feels This is normal. Nothing needs to be done.


stronger than Different areas Make sure the pads are
the other. of your body will moist and are making good
react differently. contact.

During the Adhesive gel Apply a few drops of water to


massage, the pads are not adhesive surface of each pad
skin feels a adhering firmly and make sure the pads are
painful burning to the skin. pressed firmly to the skin
sensation or The gel pads during application.
the stimulation are too dry. Use a new set of pads.
becomes wires are Use a new set of wires.
weakened. damaged.

Unit is on, but Both pads are Make sure both pads are
no sensation not firmly on the firmly pressed to the skin.
is felt in the skin. (two pads minimum) One
pads. There is a loose pad alone will not work.
connection. Make sure all connections
The intensity are secure from the unit to
level needs to the wires and the wires to the
be increased. pads.
Increase the intensity level.

27 [email protected]
http://www.brilnurse.com

Adhesive gel Adhesive Adhesive gel pads need to


pads Do not material ran out. be replaced.
stick to skin
even after
cleaning and
moistening
the gel pad.

Unit does not Battery is low. Recharge the battery.


turn on or the
screen is dim.

Unit does not Wall adapter or Charge your unit using USB
charge. USB cord. cord only using any USB
power outlet.

Only feel ●Your device ●Try to set the mode and/or


stimulation features the AB the intensity on each channel.
one channel. independent ●Try to use a new set of
channel. wires.
●Bad wire.

28 [email protected]
http://www.brilnurse.com

7. RECOMMEND USE POSITION


Neck Shoulder Back

Neck Hip

Neck Abdomen

Waist/Foot Hand Joint

29 [email protected]
http://www.brilnurse.com

Medical Disclaimer
All information is intended for you general knowledge only and
is not a substitute for medical advice or treatment for specific
medical conditions. The information contained here is intended
to provide broad consumer understanding and knowledge of
product offered.
The information should not be considered complete and should
not be used in place of a visit, call, consultation or advice or your
health care provider.

Contact
Manufacturer: Shenzhen Jianfeng Electronic Technology Co.,
Ltd.

Address: #902,903 Jialingyu Industrial Building, Dapu Road,


Houting Village, Shajing Town, Baoan District,
Shenzhen City,Guangdong Province, China.

Postal Code: 518104

Website: http://www.brilnurse.com

Email: [email protected]

30 [email protected]
http://www.brilnurse.com

Warranty
Dear customer,
Thanks for purchasing our product and welcome to join the
Brilnurse family!
Brinurse is committed to be a mature and excellent seller with
good reputation and high sense of responsibility.
We are trying our best to provides all buyers with high-quality
products and professional after-sales team.
And we feel so proud to serve you as our customer and we hope
you get the most out of your purchase.
If you have any problems, please don't hesitate to contact us. All
we want is your satisfaction!

CUSTOMER SERVICE
[email protected]
http://www.brilnurse.com
@brilnurse

Visit link or scan the QR code & Complete registration

http://www.brilnurse.com

EXTENT YOUR WARRANTY TO 2 YEARS & GET SPARE PADS

31 [email protected]

You might also like