0% found this document useful (0 votes)
32 views1 page

Celsa 2

This document provides technical specifications for IA170 split core current transformers, including applicable standards, materials, connections, insulation class, system voltage, test voltage, operating frequency, rated secondary output, rated burden, ambient temperature range, storage temperature range, thermal and dynamic short circuit currents, accuracy classes, mounting options, and dimensional details.

Uploaded by

surasakng36
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
32 views1 page

Celsa 2

This document provides technical specifications for IA170 split core current transformers, including applicable standards, materials, connections, insulation class, system voltage, test voltage, operating frequency, rated secondary output, rated burden, ambient temperature range, storage temperature range, thermal and dynamic short circuit currents, accuracy classes, mounting options, and dimensional details.

Uploaded by

surasakng36
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

CURRENT TRANSFORMERS

IA170 - Split core

IA170 Technical Features, Executions


Primary Class 0.5 / VA Class1/ VA
Current A sec. 5A
500 1.25 5
600 1.25 5
750 5 10
800 7.5 10
1000 10 20
1200 15 20
1250 15 20
1500 20 30
1600 20 30
2000 25 30
2500 25 30
3000 30 45
4000 30 45
5000 30 45

Technical Data
Applicable standard: IEC-61869-1&2 / IEC- 60044 -1, BS 3938, IS 2705 -1,2&3
Case Unfilled polycarbonate, flame retardant grades classified UL 94V-0.
Two connection on each side. M4 screws with self lifting clamp strap assembly for celsa series
Connection
and 1 connection on each side M4 screws with self lifting clamp strap for Celsa CT series.
Insulation class E (120°C max)
System voltage 720V maximum
Test voltage 4 KV 50 Hz for 1 min
Operating frequency 50Hz / 60Hz
Rated secondary output 5A standard (1A on request)
Rated burden 1, 1.25, 1.5, 2.5, 3.75, 5, 7.5, 10, 12.5, 15, 20, 30, 45 VA
Ambient temperature -25°C to +40°C
Storage temperature -25°C to +40°C
Thermal short circuit current (Ith) 60xIn for Bus Bar type CT.
Dynamic short circuit current (Idyn) 2.5xIth
Instrument security factor (FS) 2.5, 5, 10
Accuracy class 0.5, 1 and 3
Mounting busbar, cable or wall
Terminal cover hinged

Dimensiones:

Dimensions in mm
Front view a b c d e
IA170 85 245 172 177 195
Side view a’ b’ c’ d’ e’
IA170 78 71 40 62 76
Window 85 x 172

Celsa Messgerate España S.L.


www.celsamessgerate-spain.com
[email protected] / +34 96 130 93 78