Advanced Hybrid Inverter Guide

This document provides specifications for several hybrid inverter models ranging from 3kW to 6kW in power output. The inverters can operate in both off-grid and on-grid modes and feature MPPT solar charging, battery charging and discharging, and backup power functions. Key specifications covered include power ratings, voltage and current levels, charging algorithms, efficiencies, and protections.

Uploaded by

nizarb2009
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
43 views1 page

Advanced Hybrid Inverter Guide

This document provides specifications for several hybrid inverter models ranging from 3kW to 6kW in power output. The inverters can operate in both off-grid and on-grid modes and feature MPPT solar charging, battery charging and discharging, and backup power functions. Key specifications covered include power ratings, voltage and current levels, charging algorithms, efficiencies, and protections.

Uploaded by

nizarb2009
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Hybrid Inverter M ODEL

Rated power
EAHI-3000-SL
3000W
EAHI-3600-SL
3600W
EAHI-5000-SL
5000W
EAHI-6000-SL
6000W
Operating mode Flexible setting via upper computer software or display screen
3kW-6kW PV I N PUT
Max. input power 4680W 6500W 7900W
Max. input voltage 550 Vdc
Rated input voltage 420 Vdc
Highlights Start- up voltage 100 Vdc
Initial feeding voltage 150 Vdc
MPPT voltage range(Full load) 100 ~ 540 Vdc (250 ~ 450 Vdc)
Max. input current 15A 15A 15A/15A 15A/15A
Elegant appearance, wall-mounted design, easy installation Number of MPPTs 1 2
AC O UTPUT
IP65 all-aluminum body, adaptable to outdoor environment Phase Single phase(L+N+PE)
Rated AC power 3000VA / 3 000W 3600VA / 3 600W 5000VA / 5 000W 6000VA / 6 000W
Off-grid and on-grid dual output, and the switching time is less Rated output voltage 230 Vac
Output voltage range 184 ~276 Vac
than 20ms Rated output frequency 50 / 60 Hz
Output frequency range 50 ± 5 / 60 ± 5 Hz
High efficiency charging and discharging technology, compatible Rated output current 13.05 A 15.7 A 21.8 A 26.09 A
with lithium and lead-acid battery Power factor 0.8 (leading) ~ 0.8 (lagging)
THDI(@ R ated Power) ≤ 3%
EPS O UTPUT
Graphical LCD and key design, user-friendly operation interface Rated EPS power 3000 VA / 3 000 W 3600 VA / 3 600 W 5000 VA / 5 000 W 6000 VA / 6 000 W
Rated EPS voltage 230 Vac (208 / 220 / 240 Vac settable)
Flexible setting of charging and discharging time period and Rated EPS current 13.05 A 15.7 A 21.8 A 26.09 A
EPS voltage range 184 ~ 276 Vac
power, peak load shaving EPS frequency range 50 / 60 Hz ± 1%
THDv ≤ 3% (linear load)
App real-time monitoring system, easy operation and maintenance Transfer time ≤ 20 ms
BATTERY
Excellent off-grid output performance, suitable for various Battery type Li- ion, Lead- acid battery
non-linear loads Rated voltage 48 Vdc
Voltage range 42 ~ 58 Vdc
Charging current Max. 66A Max. 75A Max. 100A Max. 100A
AC charge Support
Max. charge voltage 58V(Settable)
Max. discharge current 66 A 75 A 100 A 120 A
BMS(Lithium battery )
Charging curve
3- Stage( Lead- acid battery)
System Principle Digram EFFICIEN CY
Max. efficiency 97.8%
MPPT efficiency 99.9%
Battery charge discharge efficiency 94%
OTHERS
Over/under voltage, over/under- frequency, over load, short- circuit, over temperature,
Protections PV and battery reverse polarity, leakage current, insulation resistance, anti islanding protection
Communications USB / R S485 (standard), SNMP / W i- Fi / G PRS (optional)
Warning LED, Buzzer
Display LED/LCD
EN 62109- 1, IEC62109- 2, EN 61000- 6- 2,EN 61000- 6- 3, VDE- AR- N 4105,
Standards DIN V DE 0126- 1- 1, DIN V DE V 0124- 100, CEI 0- 21,G83
IP rating IP 65
Operating temperature - 25 ~ 60 ( > 45 d erating)
Cooling mode Natural cooling
Installation mode Wall hanging
Relative humidity 0 ~ 90%
Altitude ≤3000 m (> 3000 m derating)
Noise level at 1 m ≤ 25 dB
Topology Transformer
Dimensions (W×H×D) (mm) 548 × 440 × 197 mm
Weight (kg) 23.4kg