Audita
Audita
OFFICE:
Audita Advance Equipment
Plot No. C-12, Sahaj Greens, Nr. Shree Hri Vilas,
MFG. OF PHARMACEUTICAL & SCIENTIFIC EQUIPMENT
b/h Soham Sanidhya, Ramol, Ahmedabad-382449
+91 93709 65719 | +91 89809 65719
[email protected]
auditaadvanceequipment.com
Who We Are ? Our Vision
To be the most successful and respected
industrial specialist scien fic equipment
manufacturing company in the world.
ABHISHEK BHUYAN
Director
1 2
Production & Facilities List Of Products
Stability Chamber
Temperature Range: 20°C to 60°C Humidity Range: 40%RH to 90%RH
3 4
Cold Chamber Deep Freezer
Temperature Range: 2°C to 8°C Temperature Range: -20°C
5 6
Plant Growth Chamber
Temperature Range: 20°C to 60°C Humidity Range: 40%RH to 90%RH
Photo Stability Chamber
Temperature Range: 20°C to 60°C Humidity Range: 40%RH to 90%RH Capacity: 150,250,400 up to 1000Ltrs
Temperature Range: 20°C to 60°C
Temperature Accuracy: ±0.2°C
Humidity Range: 40%RH to 90%RH
Humidity Accuracy: ±2%RH
Capacity: 200,400 up to 1000Ltrs LUX Exposure as Required(Se able)
Temperature Range: 20°C to 60°C Designed as Per GMP
Temperature Accuracy: ±0.2°C MOC SS 304 Adjustable SS Tray
Humidity Range: 40%RH to 90%RH Audio Visual Alarm
Humidity Accuracy: ±2%RH Programmable Logic Controlling System
UV Exposure 200 Wh/m² as required(Se able) PLC HMI based 21 CFR part 11 Compliance So ware
LUX Exposure 1.2 Million as Required(Se able)
21 Days Offline Data Storage facility on HMI
Designed as Per GMP
MOC SS 304 Adjustable SS Tray
Audio Visual Alarm
Programmable Logic Controlling System
PLC HMI based 21 CFR part 11 Compliance So ware
Seed Germinator
21 Days Offline Data Storage facility on HMI
Temperature Range: 20°C to 60°C Humidity Range: 40%RH to 90%RH
7 8
Bacteriological Incubator Cooling Incubator
Temperature Range: 5°C above ambient to 60°C Temperature Range: 5°C to 60°C
Temperature Range: 5°C above ambient to 60°C Temperature Range: 5°C to 60°C
Programmable Logic Controlling System PLC HMI based 21 CFR part 11 Compliance So ware
PLC HMI based 21 CFR part 11 Compliance So ware 21 Days Offline Data Storage facility on HMI
21 Days Offline Data Storage facility on HMI Micro Controller Program based Equipment Available
9 10
Oven Vacuum Oven
Temperature Range: 50°C above ambient to 300°C Temperature Range: 10°C above to 200°C
11 12
WalK-IN Chambers
Muffle Furnace Walk-In Stability Chamber
Temperature Range: 400°C to 1100°C Temperature Range: 20°C to 60°C Humidity Range: 40%RH to 90%RH
13 14
Walk-In Cold Chamber Walk-In Bacteriological Incubator
Temperature Range: 2°C to 8°C Temperature Range: 5°C above ambient to 60 °CRH
AAE/WCC-400 4000 2000Wx1000Dx2000H 2160Wx1490Dx2200H 2 10 730Wx625Dx30H 2.05KW AAE/WBI-400 4000 2000Wx1000Dx2000H 2160Wx1630Dx2200H 2 10 730Wx625Dx30H 2.5KW
AAE/WCC-600 6000 2000Wx1500Dx2000H 2160Wx1990Dx2200H 4 20 600Wx625Dx30H 2.05KW AAE/WBI-600 6000 2000Wx1500Dx2000H 2160Wx2130Dx2200H 4 20 600Wx625Dx30H 2.75KW
AAE/WCC-800 8000 2000Wx2000Dx2000H 2160Wx2490Dx2200H 4 20 850Wx625Dx30H 2.75KW AAE/WBI-800 8000 2000Wx2000Dx2000H 2160Wx2630Dx2200H 4 20 850Wx625Dx30H 2.75KW
AAE/WCC-1000 10000 2000Wx2500Dx2000H 2160Wx2990Dx2200H 6 30 720Wx625Dx30H 2.75KW AAE/WBI-1000 10000 2000Wx2500Dx2000H 2160Wx3130Dx2200H 6 30 720Wx625Dx30H 2.75KW
AAE/WCC-1200 12000 2000Wx3000Dx2000H 2160Wx3490Dx2200H 6 30 885Wx625Dx30H 3.75KW AAE/WBI-1200 12000 2000Wx3000Dx2000H 2160Wx3630Dx2200H 6 30 885Wx625Dx30H 2.75KW
AAE/WCC-1600 16000 2000Wx4000Dx2000H 2160Wx4490Dx2200H 8 40 905Wx625Dx30H 4.95KW AAE/WBI-1600 16000 2000Wx4000Dx2000H 2160Wx4630Dx2200H 8 40 905Wx625Dx30H 3.5KW
AAE/WCC-2000 20000 2000Wx4000Dx2500H 2160Wx4490Dx2700H 8 48 905Wx625Dx30H 5.95KW AAE/WBI-2000 20000 2000Wx4000Dx2500H 2160Wx4630Dx2700H 8 48 905Wx625Dx30H 4.0KW
AAE/WCC-2500 25000 2300Wx4500Dx2500H 2460Wx4990Dx2700H 10 60 815Wx750Dx30H 5.95KW AAE/WBI-2500 25000 2300Wx4500Dx2500H 2460Wx5130Dx2700H 10 60 815Wx750Dx30H 4.0KW
AAE/WCC-3000 30000 4000Wx3000Dx2500H 4160Wx3490Dx2700H 12 72 885Wx625Dx30H 6.75KW AAE/WBI-3000 30000 4000Wx3000Dx2500H 4160Wx3630Dx2700H 12 72 885Wx625Dx30H 5.0KW
AAE/WCC-4000 40000 4000Wx4000Dx2500H 4160Wx4490Dx2700H 16 96 905Wx625Dx30H 6.75KW AAE/WBI-4000 40000 4000Wx4000Dx2500H 4160Wx4630Dx2700H 16 96 905Wx625Dx30H 5.0KW
AAE/WCC-5000 50000 4500Wx4500Dx2500H 4660Wx4990Dx2700H 20 120 815Wx725Dx30H 6.75KW AAE/WBI-5000 50000 4500Wx4500Dx2500H 4660Wx5130Dx2700H 20 120 815Wx725Dx30H 6.75KW
15 16
Laminar Air Flow
Walk-In Cooling Incubator
Temperature Range: 5°C to 60°C
Size: 2ˈ×2ˈ×2ˈ;3ˈ×2ˈ×2ˈ,4ˈ×2ˈ×2ˈ;6ˈ×2ˈ×2ˈ
Class: 100
Capacity: 4000,5000 up to 50000Ltrs
Par cle Reten on:0.3 Micron
Temperature Range: 5°C to 60°C
Velocity:90ˈ/minute ± 2
Temperature Accuracy: ±0.5°C
Noise level 65db ± 5
Designed as Per GMP
Efficiency 99.97%
MOC SS 304
Audio Visual Alarm
Programmable Logic Controlling System
PLC HMI based 21 CFR part 11 Compliance So ware
21 Days Offline Data Storage facility on HMI
Panel Insula on 80 mm
Technical Specifica on
Ÿ Air Cleanliness: ISO Class 5 / Class100 / M 3.5 Area
Model Selec on Table: Ÿ Air Veloci es: 0.45±0.05 MPS (90±20FPM)
Models Cap. in Internal Size External Size Rack Tray Tray Size Connected
Ÿ Air Flow: Horizontal / Ver cal
Litres in mm in mm Qty. Qty. in mm Load Ÿ Power Supply: 230V AC, 1-O, 50Hz
AAE/WCI-400 4000 2000Wx1000Dx2000H 2160Wx1630Dx2200H 2 10 730Wx625Dx30H 2.5KW Ÿ Eu5 - Intermediate Filter (95% down to 5 micron)
AAE/WCI-600 6000 2000Wx1500Dx2000H 2160Wx2130Dx2200H 4 20 600Wx625Dx30H 2.75KW Ÿ Eu14 - HEPA filter - (99.999% down to 0.3 micron)
AAE/WCI-800 8000 2000Wx2000Dx2000H 2160Wx2630Dx2200H 4 20 850Wx625Dx30H 2.75KW Ÿ Sta cally & Dynamically balanced motor - blower with isolate to reduce noise level
AAE/WCI-1000 10000 2000Wx2500Dx2000H 2160Wx3130Dx2200H 6 30 720Wx625Dx30H 2.75KW Ÿ Fluorescent lights with milky white diffuser
AAE/WCI-1200 12000 2000Wx3000Dx2000H 2160Wx3630Dx2200H 6 30 885Wx625Dx30H 2.75KW
Ÿ Different Pressure gauge: 01 no. (hepa filter0 on/off switches (BL/FL/UV)
AAE/WCI-1600 16000 2000Wx4000Dx2000H 2160Wx4630Dx2200H 8 40 905Wx625Dx30H 3.5KW
Ÿ Auxiliary powder socket: 5/15amp to external equipment DOP port
AAE/WCI-2000 20000 2000Wx4000Dx2500H 2160Wx4630Dx2700H 8 48 905Wx625Dx30H 4.0KW
Ÿ DQ,IQ,OQ,PQ Documenta on
AAE/WCI-2500 25000 2300Wx4500Dx2500H 2460Wx5130Dx2700H 10 60 815Wx750Dx30H 4.0KW
AAE/WCI-3000 30000 4000Wx3000Dx2500H 4160Wx3630Dx2700H 12 72 885Wx625Dx30H 5.0KW
AAE/WCI-4000 40000 4000Wx4000Dx2500H 4160Wx4630Dx2700H 16 96 905Wx625Dx30H 5.0KW
AAE/WCI-5000 50000 4500Wx4500Dx2500H 4660Wx5130Dx2700H 20 120 815Wx725Dx30H 6.75KW
17 18
Biosafety Cabinet Pass Box
19 20
Airshower Unit Dispensing Booth
21 22
21 CFR Complice So ware
PLC Based Features
21 CFR Part 11 Complice So ware :
• So ware developed based on 21 CFR Part 11 Compliance
Instruments Type
• Reports Includes: Temperature & Rh master data & Scanner Data Report, Graph
Reports, Machine Alarm Reports, Machine Audit Reports, So ware Audit Reports,
MKT Reports in Non Editable Pdf Format
Hea ng Cooling Stability
Products Products Products • Electronic Signature
• Password Complexity
& Expiry, and Block
Salient Features Safety User if more than 3
• PLC & HMI Touch Controller wrong password
• Compressor Standby +
• PID Precise Control Ac on a empts
Auto-changeover
• Data, Alarm, User Logging • Humidity Heater Standby • Connec vity: Ethernet
• SMS / Email Alert System • RH Limits Alert LAN Cable, can be
• 21 CFR So ware connected to any PC to
• Non Editable PDF Reports Machine within same
• Printer Interface Op onal Network
• Remote Monitoring IOT
• SMS Alert • User Management, access based on Level
• Scanner 4/8/16/24 Channel
• Email Alert
• Resolu on 0.1°c & 0.1%
• Remote Access • Offline Record can stored upto 1 lakh
• Accuracy 0.1°C & 0.5%
• IOT records, and Downloads within 1 mins
• Uniformity 0.5°C & 1-2% Display
• Mul ple Chamber Connec vity Op on
Serial Serial
Printer
Serial
LAN RJ45
Ethernet
23 Analog Sensors 24
Data Logger So ware Salient Features
Data Logging : • Our So ware comply the 21 CFR Part 11 guidelines set by the FDA (Food and Drug
Administra on), mainly Recoding Electronic Record and Signature which are considered
• Temperature & RH data record are Equivalent to Paper Records and Handwri en Signatures.
stored in Memory with Date & • Our So ware is an Advance PLC HMI base So ware
Time Stamp. • Our So ware is designed to Control and Monitor Parameters of the Equipments Provided by Our
• Upto 2 Lakh Record can be saved So ware ADVANCE EQUIPMENT.
in Internal Memory respec vely. • Our So ware is designed to Monitor Parameters of the Equipments from any PC within the Server
• Scanner Data will also be recorded of the Pharmaceu cal or Scien fic Organiza on assigned by the Organiza on.
if Scanner is available. • Our So ware has the following func on
• One So ware connects mul ple equipment of different Departments irrespec ve of Equipment's
loca ons.
Alarm Logging : • High Speed Ethernet Connec vity
• Temperature & RH data record are • User friendly UI.
stored in Memory with Date & • Mul ple User Group Crea on.
Time Stamp. • Mul ple User Crea on assigned with specific user group.
• User Login, Logout with Correct User ID and password.
• Upto 2 Lakh Record can be saved
• Password Protec on Alphanumeric Password.
in Internal Memory respec vely.
• User Lockout on Mul ple wrong a empts.
• Scanner Data will also be recorded
• Password Length Se able.
if Scanner is available.
• History of Login Logout Of user.
• Equipment Master Sensor TEMPERATURE and HUMIDITY Data Report.
Audit Logging : • Equipment Scanner Sensor TEMPERATURE and HUMIDITY Data Report.
• MKT Report.
• User Opera on will be recorded &
• MKRH Report.
stored in Memory with Date &
• Alarm Report.
Time Stamp.
• Event Report
• Upto 1 Lakh Record can be saved
• SMS and Email for Alarm and Events.
in Internal Memory respec vely. • BIOMETRIC Access.
• Audit Trail Report for User Login Logout.
• Audit Trail Report for Equipment all ac vity Performed.
• Audit Trail So ware User-wise or Equipment-wise or for all irrespec ve of User and Equipment.
• Header of the Reports with Customer Company Name, LOGO, Set Values, Set Values Limits, Time
Printer : Stamp of Report Crea on, Verifica on.
• If Printer is Connected, Direct Online Data • and more
21
25 12
26