0% found this document useful (0 votes)
56 views5 pages

Datasheet 1196812 SSW301HV-115V 10102010-171535

This document provides detailed technical specifications for a fail-safe standstill monitor called the SSW 301HV-115V. It includes information on the product's approvals, properties, ambient conditions, electrical data, inputs, outputs, LED display conditions, dimensions, applications, and links to additional documents.

Uploaded by

CRISENTENA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views5 pages

Datasheet 1196812 SSW301HV-115V 10102010-171535

This document provides detailed technical specifications for a fail-safe standstill monitor called the SSW 301HV-115V. It includes information on the product's approvals, properties, ambient conditions, electrical data, inputs, outputs, LED display conditions, dimensions, applications, and links to additional documents.

Uploaded by

CRISENTENA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Print - Create PDF - Create EXCEL file 10.10.

2010
-
17:15:34h

Datasheet - SSW 301HV-115V


Fail-safe standstill monitors / SSW 301HV

• Fail-safe standstill monitors


• This fail-safe standstill monitor has the particular advantage that no adjustment
for a required-value is needed during comissioning.
• 3 safety contacts, STOP 0
• 1 Signalling output
• Control category 4 to EN 954-1

(Minor differences between the printed image and the original product
may exist!)

Ordering details

Product type description SSW 301HV-115V


Article number 1196812
EAN code 4030661364971

Approval

Approval
USA/CAN

Global Properties

Product name SSW 301HV


Standards IEC/EN 60204-1, IEC 60947-5-3, EN 954-1, BG-GS-ET-14, BG-GS-ET-20
Compliance with the Directives (Y/N) Yes
Climatic stress EN 60068-2-3
Mounting snaps onto standard DIN rail to EN 60715
Terminal designations EN 50005, EN 50013
Materials
- Material of the housings Plastic, glass-fibre reinforced thermoplastic
- Material of the contacts , self-cleaning, positive action
Weight
Start conditions Automatic after detection of the standstill
Start input (Y/N) No
Feedback circuit (Y/N) Yes
Start-up test (Y/N) No
Reset after disconnection of supply voltage (Y/N) -
Automatic reset function (Y/N) Yes
Reset with edge detection (Y/N) No
Pull-in delay
- ON delay with automatic start approx. 7 s after detection of the standstill
Drop-out delay
- Drop-out delay in case of emergency stop < 15 ms

Mechanical data

Connection type Screw connection


Cable section
- Min. Cable section 0,5 mm²
- Max. Cable section 2.5 mm²
Pre-wired cable rigid or flexible
Tightening torque for the terminals 0,6 Nm
Detachable terminals (Y/N) No
Mechanical life 10.000.000 operations
Electrical lifetime Derating curve available on request
restistance to shock 30 g / 11 ms
Resistance to vibration To EN 60068-2-6 10 ... 55 Hz, Amplitude 0,35 mm

Ambient conditions

Ambient temperature
- Min. environmental temperature - 25°C
- Max. environmental temperature + 45°C
Storage and transport temperature
- Min. Storage and transport temperature - 25°C
- Max. Storage and transport temperature + 70°C
Protection class
- Protection class-Enclosure IP40
- Protection class-Terminals IP20
- Protection class-Clearance IP54
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp 6 kV
- Overvoltage category III To VDE 0110
- Degree of pollution 2 To VDE 0110

Electromagnetic compatibility (EMC)

EMC rating conforming to EMC Directive

Electrical data

Rated DC voltage for controls


- Min. rated DC voltage for controls -
- Max. rated DC voltage for controls -
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz 97.75 V
- Max. rated AC voltage for controls, 50 Hz 126.5 V
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz 97.75 V
- Max. rated AC voltage for controls, 60 Hz 126.5 V
Contact resistance max. 100 mΩ
Power consumption 3.0 W, 4 VA
Type of actuation AC
Rated operating voltage Ue 115 VAC
Frequency range 50 / 60 Hz
Electronic protection (Y/N) No
Fuse rating for the operating voltage 80 mA slow blow

Inputs

Monitored inputs
- Short-circuit recognition (Y/N) Yes
- Wire breakage detection (Y/N) Yes
- Earth connection detection (Y/N) Yes
Number of shutters 0 piece
Number of openers 0 piece
Cable length 10 m

Outputs

Stop category 0
Number of safety contacts 3 piece
Number of auxiliary contacts 0 piece
Number of signalling outputs 1 piece
Switching capacity
- Switching capacity of the safety contacts max. 250 VAC, 6 A ohmic ( inductive in case of appropriate protective wiring)
- Switching capacity of the signaling/diagnostic outputs 24 VDC, 2 A
Fuse rating
- Protection of the safety contacts 6 A gG D-fuse
- Fuse rating for the signaling/diagnostic outputs 2 A gG D-fuse A
Number of undelayed semi-conductor outputs with signaling
function 0 piece
Number of undelayed outputs with signaling function (with
contact) 1 piece
Number of delayed semi-conductor outputs with signaling
function. 0 piece
Number of delayed outputs with signalling function (with contact). 0 piece
Number of secure undelayed semi-conductor outputs with
signaling function 0 piece
Number of secure, undelayed outputs with signaling function, with
contact. 3 piece
Number of secure, delayed semi-conductor outputs with signaling
function 0 piece
Number of secure, delayed outputs with signaling function (with
contact). 0 piece

LED switching conditions display

LED switching conditions display (Y/N) Yes


Number of LED´s 5 piece
LED switching conditions display
- The integrated LEDs indicate the following operating states.
- UB: Supply voltage available
- B: Frequency at channel B
- A: Frequency at channel A
- OUT: Enabling safety contacts 13-14, 23-24 closed
- ERR: Error functional defect
Miscellaneous data

Applications
safe standstill monitoring

Dimensions

Dimensions
- Width 90 mm
- Height 83 mm
- Depth 127 mm

notice

Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

notice - Wiring example

The sensor-free standstill monitor checks the e.m.f. of the three phase motor.
To secure a guard door
The wiring diagram is shown with guard doors closed and in de-energised condition.

Documents

Operating instructions and Declaration of conformity (de) 1 MB, 25.06.2010


http://127.0.0.1/Bilddata/Si_baust/Pdf/ssw301hv/bedien/DE/mrl_ssw_301hv_de.pdf

Operating instructions and Declaration of conformity (en) 899 kB, 21.01.2010


http://127.0.0.1/Bilddata/Si_baust/Pdf/ssw301hv/bedien/EN/mrl_ssw_301hv_en.pdf

Wiring example (99) 18 kB, 20.08.2008


http://127.0.0.1/Bilddata/Si_baust/ssw301hv/schaltun/kssw3l01.pdf

Images

Wiring example

K.A. Schmersal GmbH, Möddinghofe 30, D-42279 Wuppertal


The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 10.10.2010 - 17:15:35h Kasbase 1.4.0 DBI