1. General Information........................................................................................................... 3
Scope
Product Classification
Model Name
2. Nominal Specification........................................................................................................ 3
Capacity
Nominal Voltage
Operating Voltage Range
Nominal Charge
Charge Current
Nominal Discharge
Discharge Current
Weight
Operating Temperature & Humidity
Storage Temperature
3. Appearance and Dimension.................................................................................................................. 4
Appearance
Dimension
4. Performance Specification.................................................................................................................... 5
Standard Test Condition
Electrical and Environmental Specification
Safety Test Performance
Reliability Characteristics
5. Certification.......................................................................................................................................8
6. Cautions and Prohibitions in Handling............................................................................................. 8
Cautions for Use and Handling
Prohibitions Cautions
for the battery and the pack
7. Exclusion of Liability.............................................................................................................................12
2
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
CONFIDENTIAL
.
1. General Information
Scope
This product specification defines the requirements of the rechargeable lithium ion battery cell to be supplied to
the Customer by Shenzhen Coslight Power.
3
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
CONFIDENTIAL
.
Dimension
Thickness*Width*Height 19.8*106*288
Cell height with terminals 300
Distance between terminals 23.7±0.5;Symmetry
Center distance of the terminals 50±0.5
Overall Dimensions(mm) Terminal position Symmetry
Terminal Length*Width*Height (Φ6±0.05)*(8±1)
Flatness of terminals <0.25
Length * width of OPSD Φ11±0.05
4
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
. CONFIDENTIAL
4. Performance Specification
4.1 Standard test condition
4.1.1 Nominal Charge
Unless otherwise specified, “Nominal Charge” shall consist of charging at constant current of 25A to 3.70V. The
cell shall then be charged at constant voltage of 3.70V while tapering the charge current. Charging shall be
terminated when the charging current has tapered to 1A. For test purposes, charging shall be performed at25 ± 2ºC.
4.1.2 Nominal Discharge
“Nominal Discharge” shall consist of discharging at constant current of 25A to 2.5V. Discharging is to be
performed at 25 ± 2 ºC unless otherwise noted (such as capacity versus temperature).
4.1.3 Fast Charge Condition
Cells shall be charged at constant current of 50A to 3.70V. The cell shall then be charged at constant voltage of
3.70V while tapering the charge current. Charging shall be terminated when the charging current has tapered to 1A.
For test purposes, charging shall be performed at 25 ± 2ºC.
5
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
. CONFIDENTIAL
Cells Shall be full charged per 4.1.1 and discharged per Appearance: no obvious
4.1.2 at following temperature. Record discharge deformation, no rupture, no
4.2.5 capacity. leakage
Discharge
Temperature
Capacity (vs. Initial Capacity)
Performance Charge Discharge
100%
0.5C 0.5C
95%
3C
After full charge per 4.1.1, stay in 25±2℃ constant
temperature cabinet for 28 days, standard discharge per Remaining capacity ≥ rated
4.2.7 4.1.2. Record discharge capacity. Then full charge per capacity * 90 %
Electricity holding 4.1.1 and discharge per 4.1.2, repeat for 3 times. Record Recovery capacity ≥ rated
capacity
the 3 rd discharge capacity as recovery capacity. capacity * 95 %
4.3.2 Measure the initial state of the battery. After the battery is
Over discharge No explosion, no fire charged, discharge 90 min with 1 CA constant current for
performance 1 hour.
6
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
. CONFIDENTIAL
4.3.4 After the battery is charged, the test state of the battery is
Overheat measured, the battery is placed in a drum oven, and the
The battery shall not fire or
performance rate of(5 ± 2) °C / min is heated from room temperature
explode within 10 min at a
to(130 ± 2) °C, and at this temperature, the temperature is
temperature of 130 ± 2 °C
constant. 10 min, Record failure mode and time of
failure.
7
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
. CONFIDENTIAL
(2) Final state: including the final appearance of the battery, open circuit voltage, AC internal resistance,
thickness and weight.
(3) Surplus capacity: the first discharge capacity of the battery after a specific detection procedure.
(4) Recovery capacity: After the battery has undergone a specific detection procedure, the discharge capacity
after the state is restored through repeated charging and discharge.
(5) Standard cycle: After the battery is charged, it is stationary for 10 minutes. At an ambient temperature of 25 ±
2 °C, the standard discharge is to terminate the voltage.
(6) Deformation: Change in battery size by more than 10 %
(7) Leakage: Leakage of electrolytes, gases or other substances from the battery, if there is no obvious indication,
can be determined by the loss of weight of the battery: When the weight of the battery less than 1g is lost by more
than 0.5 %, Leakage is determined by loss of more than 0.2 % for batteries weighing more than 1g but less than 5g
and 0.1 % for batteries weighing more than 5g.
(8) Pressure discharge: The battery is subjected to internal pressure to cause the safety device to move out of the
exhaust or liquid, and the outer part of the shell other than the safety device remains intact.
(9) Fire: Fire and flame appear on the surface of the battery.
(10) Explosion: Instantly ejected solid material from the inside of the battery, the shell is incomplete.
Circulation of charge and discharge currents not specified in the standard is performed in accordance with the
standard cycle.
5.Certification
——
6.CautionsandProhibitions inHandling
Warning for using the rechargeable lithium-ion battery cell - Mishandling of the battery may cause
heat, fire and deterioration in performance. Be sure to observe the following.
8
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
. CONFIDENTIAL
Prohibitions
Do not charge with constant current higher than maximum charge current.
Do not attempt to disassemble or alter battery cells.
Do not throw or subject the battery to severe impacts.
Do not puncture or otherwise damage a battery with sharp objects (e.g. nail, knife, pencil, drill)
Do not use with other batteries or cells.
Do not directly solder on battery.
Do not press the battery with overload in manufacturing process, especially while undergoing ultrasonic
welding.
Do not use old and new cells together for battery pack assembly.
Do not expose the battery to high heat.
(such as a fire).
Do not microwave or put batteries under high pressure.
Do not use the battery in reverse.
Do not connect positive(+) and negative(-) terminals with conductive materials (such as metal, wire, etc.)
Do not immerge or wet batteries with water or sea-water.
Do not give immoderate heat and force to cell during a welding process of metal plates on it.
Do not bend or apply excessive force to the welded part of terminals.
9
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
. CONFIDENTIAL
specified in this Product Specification. If one or more than one function is/are to be omitted, the Packer
Company (and/or System Integration Company) must be informing to Shenzhen Coslight Power or to
Shenzhen Coslight Power’s Marketing Department. Without informing to Shenzhen Coslight Power,
Shenzhen Coslight Power will not be liable for any field quality issues happened due to exclusion of
following functions.
Over voltage protection circuit
(1) Under voltage protection circuit
(2) Over Charge current protection circuit
(3) Over Discharge current protection circuit
(4) Short circuit protection
(5) Over Temperature protection circuit
(6) 2nd over voltage protection
(7) Cell imbalance protection circuit (only for battery packs assembled with more than one cell)
(8)Cell Voltage balancing function (only for battery packs assembled with more than one cell)
7. Exclusionof Liability
The warranty shall not cover defects caused by normal wear and tear, inadequate maintenance, handling,
storage, faulty repair, modification to the battery or pack by a third party other than Shenzhen Coslight
Power or Shenzhen Coslight Power’s agent approved by Shenzhen Coslight Power, failure to observe the
product specification provided herein or improper use of installation, including but not limited to, the
following:
Damage during transport or storage
Incorrect installation of battery into pack or maintenance
Use of battery cell or battery pack in inappropriate environment
Improper, or incorrect charge / discharge, or protection of circuits other than stipulated herein
Incorrect use or inappropriate use
Insufficient ventilation
Ignoring applicable safety warnings and instructions
Any attempt to alter or repair by unauthorized personnel
In case of force majeure (Ex. Lightening, Storm, Flood, Fire, Earthquake,etc.)
There are no warranties – implied or express – other than those stipulated herein. Shenzhen Coslight
Power shall not be liable for any consequential or indirect damages arising out of or in connection with
the product specification, battery or pack
10