SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.

. CONFIDENTIAL

Version: Ver 1.0


Date: 23/06/2020
Doc No:

SHENZHEN COSLIGHT POWER


TECHNOLOGY CO.,LTD
Rechargeable Lithium-ion Battery Cell

Product Specifications

Lithium iron phosphate


Product Name
battery

Model FP20106300A-50Ah

Prepared By Gao mu sen

Checked By Shi qing mo

Approved By Song bai

Effective Date

SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.


Address:No.37,Xiangshan avenue, Luotiancommunity,Yanluo

street, Baoan district,Shenzhen

1
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
. CONFIDENTIAL

Revision History
Revison Date Originator Description

1
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD. CONFIDENTIAL

Contents
Revision History....................................................................................................................... 1
Contents.....................................................................................................................................2
1. General Information........................................................................................................... 3
Scope
Product Classification
Model Name
2. Nominal Specification........................................................................................................ 3
Capacity
Nominal Voltage
Operating Voltage Range
Nominal Charge
Charge Current
Nominal Discharge
Discharge Current
Weight
Operating Temperature & Humidity
Storage Temperature
3. Appearance and Dimension.................................................................................................................. 4
Appearance
Dimension
4. Performance Specification.................................................................................................................... 5
Standard Test Condition
Electrical and Environmental Specification
Safety Test Performance
Reliability Characteristics
5. Certification.......................................................................................................................................8
6. Cautions and Prohibitions in Handling............................................................................................. 8
Cautions for Use and Handling
Prohibitions Cautions
for the battery and the pack
7. Exclusion of Liability.............................................................................................................................12

2
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
CONFIDENTIAL
.

1. General Information
Scope
This product specification defines the requirements of the rechargeable lithium ion battery cell to be supplied to
the Customer by Shenzhen Coslight Power.

Product Classification: Lithium-ion Battery Cell


Model Name: FP20106300A
2. Nominal Specification
Item Condition / Note Specification

Nominal charge / discharge at 25℃


2.1 Capacity ≥50Ah

Average for nominal discharge


2.2 Nominal Voltage 3.2 V

2.3 Operating Voltage Range 0%~100% SOC


2.50 ~ 3.70 V

Constant current 25 A (0.5 C)


2.4 Nominal Charge Constant voltage 3.70 V
End condition (Cut off) 1A
Fast Continuous Charge current
50A (1 C)
2.5 Charge Current (25℃)
Max Continuous Charge Current
50A (1 C)

Constant current 25A (0.5 C)


2.6 Nominal Discharge End voltage(Cut off) 2.50 V
2.7 Discharge Current (25℃) Max Continuous Discharge Current
150A (3C)

2.8 Weight / 1.2±0.03 kg

Charge 5 ~ 45℃, ≤85%RH


2.9 Operating Temperature
&Humidity
Discharge -20~60 ℃, ≤85%RH

≤1M -20 ~ 60℃,50%SOC


≤3M -20 ~ 45℃,50%SOC
2.10 Storage Temperature -20 ~ 25℃,50% SOC
≤12M After every tree months, 100%
DOD is needed before
recharged to 50% SOC
1)It can be adjusted upon discussion with Shenzhen Coslight Power because battery life span can be differentiated by
user patterns and environment.

3
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
CONFIDENTIAL
.

3. Appearance and Dimension


Appearance
There shall be no such defects as deep scratch, crack, rust, discoloration or leakage, which may adversely affect
the commercial value of the cell.

Dimension
Thickness*Width*Height 19.8*106*288
Cell height with terminals 300
Distance between terminals 23.7±0.5;Symmetry
Center distance of the terminals 50±0.5
Overall Dimensions(mm) Terminal position Symmetry
Terminal Length*Width*Height (Φ6±0.05)*(8±1)
Flatness of terminals <0.25
Length * width of OPSD Φ11±0.05

4
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
. CONFIDENTIAL

4. Performance Specification
4.1 Standard test condition
4.1.1 Nominal Charge
Unless otherwise specified, “Nominal Charge” shall consist of charging at constant current of 25A to 3.70V. The
cell shall then be charged at constant voltage of 3.70V while tapering the charge current. Charging shall be
terminated when the charging current has tapered to 1A. For test purposes, charging shall be performed at25 ± 2ºC.
4.1.2 Nominal Discharge
“Nominal Discharge” shall consist of discharging at constant current of 25A to 2.5V. Discharging is to be
performed at 25 ± 2 ºC unless otherwise noted (such as capacity versus temperature).
4.1.3 Fast Charge Condition
Cells shall be charged at constant current of 50A to 3.70V. The cell shall then be charged at constant voltage of
3.70V while tapering the charge current. Charging shall be terminated when the charging current has tapered to 1A.
For test purposes, charging shall be performed at 25 ± 2ºC.

4.2 Electrical and Environmental Specification


Item Condition Specification
4.2.1 50% SOC cells shall be measured at least 1KHz by
Initial AC Impedance internal resistance device ≤1.0 mΩ

Cells shall be full charged per 4.1.1 and discharged per


4.1.2within 10min after full charge at 25±2℃.Record
4.2.2 discharge capacity. Repeat 3 times. When the range of
≥50.0 Ah,
Initial Capacity three consecutive test is less than 3% of Nominal
capacity, finish test. Take average of the last 3 times as
result.

4.2.3 Voltmeter,50% SOC,25 ± 2℃.


Open circuit voltage 3.30V±0.10V

Cells shall be full charged by 0.5C and discharged per


4.2.4 4.1.2 2000 cycles at 25 ºC. A cycle is defined as one
≥ 80 % vs.Initiation Capacity
Cycle Life charge and one discharge.

5
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
. CONFIDENTIAL

Cells Shall be full charged per 4.1.1 and discharged per Appearance: no obvious
4.1.2 at following temperature. Record discharge deformation, no rupture, no
4.2.5 capacity. leakage
Discharge
Temperature
Capacity (vs. Initial Capacity)
Performance Charge Discharge

- 20ºC(2.0V cut off) 70%


25± 2ºC 25ºC 100%
55ºC 95%
Cells Shall be full charged per 4.1.1 and discharged Appearance: no obvious
according to following discharge current,2.5V cut off. deformation, no rupture, no
4.2.6 Record discharge capacity. leakage
Discharge Ratio
Performance at
Capacity (vs. Initial Capacity)
25± 2ºC Charge Discharge

100%
0.5C 0.5C
95%
3C
After full charge per 4.1.1, stay in 25±2℃ constant
temperature cabinet for 28 days, standard discharge per Remaining capacity ≥ rated
4.2.7 4.1.2. Record discharge capacity. Then full charge per capacity * 90 %
Electricity holding 4.1.1 and discharge per 4.1.2, repeat for 3 times. Record Recovery capacity ≥ rated
capacity
the 3 rd discharge capacity as recovery capacity. capacity * 95 %

4.3 Safety Test Performance


Item Specification Test Condition
After measuring the initial state of the battery, after the
battery is charged, the battery is charged with a constant
4.3.1 current of 1 CA current to the voltage that reaches 1.5
Over charge No explosion, no fire times the charging termination voltage specified in the
performance enterprise technical conditions or the charging time
reaches 1 hour and stops charging. Observe 1 hour and
record the failure mode. And the failure time.

4.3.2 Measure the initial state of the battery. After the battery is
Over discharge No explosion, no fire charged, discharge 90 min with 1 CA constant current for
performance 1 hour.

After the battery is recharged, the test state of the battery


4.3.3 is measured, and then the positive and negative poles are
Short circuit No explosion, no fire short connected with a wire with a resistance of 5mΩ,
performance and 10min is observed to record the failure mode and the
failure time.

6
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
. CONFIDENTIAL

4.3.4 After the battery is charged, the test state of the battery is
Overheat measured, the battery is placed in a drum oven, and the
The battery shall not fire or
performance rate of(5 ± 2) °C / min is heated from room temperature
explode within 10 min at a
to(130 ± 2) °C, and at this temperature, the temperature is
temperature of 130 ± 2 °C
constant. 10 min, Record failure mode and time of
failure.

After the battery is charged, the test state of the battery is


measured, that is, the appearance, open-circuit voltage,
AC resistance, and thickness before the extrusion test.
The maximum plane of the battery is placed parallel to
4.3.5 the extrusion table. 1. Squeeze direction: perpendicular to
Extrusion No explosion, no fire the direction of the battery plate. Pressure. 2. Extrusion
performance head area: not less than 20cm2; 3.Extrusion degree: Until
the battery shell breaks or the internal short circuit(the
battery voltage becomes 0V), immediately release the
pressure, observe for 1 hour, record the failure mode and
the failure time.

4.4 Reliability Characteristics


Item Specification Test Condition

Measurement of initial battery capacity; Standard charging


into 50 % charged state energy, that is, the initial state before
Remaining capacity ≥
4.4.1 storage; Open circuit holds for 7 days at 55 °C ± 2 °C to
nominal capacity * 80 %
Storage measure the process state of the battery, that is, the appearance
Appearance: no obvious
performance at after storage, open circuit voltage, AC resistance, thickness
deformation, no leakage, no
55 °C and weight; Then open the road at room temperature and
smoke, no explosion.
shelve 2H. The standard discharge to the end voltage measures
the remaining capacity of the battery.

Measurement of initial battery capacity; After standard


charging, the test state of the battery is measured, that is, the
initial state at the beginning of the test; Within 1 hour, the
Remaining capacity ≥ battery is fixed on the vibration table and subjected to
nominal capacity * 95 %, vibration tests. The battery is subjected to a frequency of 10 to
4.4.2 Appearance: There should be 55 Hz, an amplitude of 1.6 mm, and a sweep frequency
Vibration no obvious damage, no vibration with a sweep rate of 1 oct/min. The frequency is
performance leakage, no deformation, no swept in X, Y, and Z directions. 10 times; After the frequency
smoke, no explosion. sweep is over, the final state of the battery is measured, that is,
the final appearance, open circuit voltage, AC internal
resistance, thickness and weight; Standard discharge to
termination voltage, measure battery residual capacity and
final state.

Remarks: Definition and determination of some terms in the above criteria.


(1) Initial state: including battery initial appearance, open circuit voltage, AC internal resistance, thickness and
weight.

7
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
. CONFIDENTIAL

(2) Final state: including the final appearance of the battery, open circuit voltage, AC internal resistance,
thickness and weight.
(3) Surplus capacity: the first discharge capacity of the battery after a specific detection procedure.
(4) Recovery capacity: After the battery has undergone a specific detection procedure, the discharge capacity
after the state is restored through repeated charging and discharge.
(5) Standard cycle: After the battery is charged, it is stationary for 10 minutes. At an ambient temperature of 25 ±
2 °C, the standard discharge is to terminate the voltage.
(6) Deformation: Change in battery size by more than 10 %
(7) Leakage: Leakage of electrolytes, gases or other substances from the battery, if there is no obvious indication,
can be determined by the loss of weight of the battery: When the weight of the battery less than 1g is lost by more
than 0.5 %, Leakage is determined by loss of more than 0.2 % for batteries weighing more than 1g but less than 5g
and 0.1 % for batteries weighing more than 5g.
(8) Pressure discharge: The battery is subjected to internal pressure to cause the safety device to move out of the
exhaust or liquid, and the outer part of the shell other than the safety device remains intact.
(9) Fire: Fire and flame appear on the surface of the battery.
(10) Explosion: Instantly ejected solid material from the inside of the battery, the shell is incomplete.
Circulation of charge and discharge currents not specified in the standard is performed in accordance with the
standard cycle.

5.Certification
——

6.CautionsandProhibitions inHandling
Warning for using the rechargeable lithium-ion battery cell - Mishandling of the battery may cause
heat, fire and deterioration in performance. Be sure to observe the following.

 Cautions for Use and Handling


 Before using devices equipped with the battery, refer to the user’s manual.
 Battery cells must be charged and discharged at operating temperature range.
 Battery cells must be charged and discharged below max. electric current of each operating temperature
range.
 Positive (+) and negative (-) direction must be checked before battery packassembly.
 When a lead plate or wire is connected to the cell for battery pack assembly, check insulation not to
make short-circuits.
 Battery cells must be stored separately.
 Battery cells must be stored in a cool, dry place for long-term storage.
 Do not place the battery in direct sunlight or heat.
 Do not use battery cells in high static electricity environment where the protection device can be
damaged.
 When rust or odor is detected before initial use, please return the product to the sellerimmediately.
 Battery cells must be kept away from children or pets
 When cell life span shortens after long usage, please replace with new cell.
 Do insulate between the metal plate and cell or other components not to make an electrical short.
 Battery cells should be handled by and used in Pack / System manufacturing companies only.
 Battery cells should be sold only to Battery Pack Maker(s) or System Integrator(s).
 The cells should not be handled by or sold to individual consumers.
 Be sure to request and confirm the most recent product specifications in advance.

8
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
. CONFIDENTIAL

 Prohibitions
 Do not charge with constant current higher than maximum charge current.
 Do not attempt to disassemble or alter battery cells.
 Do not throw or subject the battery to severe impacts.
 Do not puncture or otherwise damage a battery with sharp objects (e.g. nail, knife, pencil, drill)
 Do not use with other batteries or cells.
 Do not directly solder on battery.
 Do not press the battery with overload in manufacturing process, especially while undergoing ultrasonic
welding.
 Do not use old and new cells together for battery pack assembly.
 Do not expose the battery to high heat.
(such as a fire).
 Do not microwave or put batteries under high pressure.
 Do not use the battery in reverse.
 Do not connect positive(+) and negative(-) terminals with conductive materials (such as metal, wire, etc.)
 Do not immerge or wet batteries with water or sea-water.
 Do not give immoderate heat and force to cell during a welding process of metal plates on it.
 Do not bend or apply excessive force to the welded part of terminals.

 Cautionsforthe battery and the pack


 Pack shall meet under condition to maintain battery safety and last long performance of the
rechargeable lithium-ion cells.
 Installing the battery into the pack
 Battery cells should be inspected visually before battery pack assembly
 Damaged cell should not be used.
 Different types of cells, or same types but different cell maker’s should not be used together.
 Design of battery pack
 The battery pack must be designed to prevent external short circuit.
 The design of battery pack and its structure should be reviewed physically, mechanically and
electrically not to cause cell imbalance.
 The battery pack for multiple cells should be designed to monitor the voltage.
 Charge
 Charging should be operating under maximum charge voltage and current which is
specified in product specification.
 The battery should be charged under operating temperature specified in product specification. (Refer to
2.9)
 Discharge
 Discharging should be operating under maximum discharge voltage and current which is
specified in product specification.
 Discharging should be done by cut off voltage which is specified in product specification. (Refer to 2.6)
 The battery should be discharged under operating temperature specified in product specification. (Refer
to 2.9)
 Protection Circuit
 The protection circuit should be installed in the battery pack.
 Battery pack should have voltage sensing system to control over charge or discharge.
 Battery pack should have warning system for over temperature, over voltage and over current
When battery packs for any applications are assembled with cells, following functions must be
designed into the battery packs.
The detailed levels, values, conditions for each following functions should be referring to the contents

9
SHENZHEN COSLIGHT POWER TECHNOLOGY CO.,LTD.
. CONFIDENTIAL

specified in this Product Specification. If one or more than one function is/are to be omitted, the Packer
Company (and/or System Integration Company) must be informing to Shenzhen Coslight Power or to
Shenzhen Coslight Power’s Marketing Department. Without informing to Shenzhen Coslight Power,
Shenzhen Coslight Power will not be liable for any field quality issues happened due to exclusion of
following functions.
Over voltage protection circuit
(1) Under voltage protection circuit
(2) Over Charge current protection circuit
(3) Over Discharge current protection circuit
(4) Short circuit protection
(5) Over Temperature protection circuit
(6) 2nd over voltage protection
(7) Cell imbalance protection circuit (only for battery packs assembled with more than one cell)
(8)Cell Voltage balancing function (only for battery packs assembled with more than one cell)
7. Exclusionof Liability
The warranty shall not cover defects caused by normal wear and tear, inadequate maintenance, handling,
storage, faulty repair, modification to the battery or pack by a third party other than Shenzhen Coslight
Power or Shenzhen Coslight Power’s agent approved by Shenzhen Coslight Power, failure to observe the
product specification provided herein or improper use of installation, including but not limited to, the
following:
 Damage during transport or storage
 Incorrect installation of battery into pack or maintenance
 Use of battery cell or battery pack in inappropriate environment
 Improper, or incorrect charge / discharge, or protection of circuits other than stipulated herein
 Incorrect use or inappropriate use
 Insufficient ventilation
 Ignoring applicable safety warnings and instructions
 Any attempt to alter or repair by unauthorized personnel
 In case of force majeure (Ex. Lightening, Storm, Flood, Fire, Earthquake,etc.)
There are no warranties – implied or express – other than those stipulated herein. Shenzhen Coslight
Power shall not be liable for any consequential or indirect damages arising out of or in connection with
the product specification, battery or pack

10

You might also like