CONSTRUCTION NOTES

A. GENERAL
1. THE FOLLOWING CONSTRUCTION NOTES AND TYPICAL DETAILS HAS BEEN APPLIED TO ALL DRAWING 5. REINFORCING BARS HAS BEEN LAPPED A MINIMUM OF 30 BAR DIAMETERS WHERE SPLICE
AND A MORE MODIFIED DETAIL WAS PROVIDED TO MEET SPECIAL CONDITION. DOWELS FROM FOOTING OR SLABS HAS EXTENDED INTO THE BLOCK WALL A MINIMUM OF
2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEELS, 30 BAR DIAMETERS. REBARS WAS PROPERLY TIED W/ G.I. WIRE.
MISCELLANEOUS IRON,PRE-CAST CONCRETE ETC,HAS BEEN SUBMITTED FOR ENGINEERS 6. ALL CELLS CONTAINING REINFORCING BARS OR INSERTS HAS BEEN SOLIDLY FILLED WITH
APPROVAL BEFORE FABRICATION. CONCRETE GROUT (REFER TO SPECIFICATIONS)
3. THE CONTRACTOR HAS VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN CHECK WITH 7. LAP SPLICES AND HOOKS
MECHANICAL AND ELECTRICAL CONTRACTORS FOR CONDUITS PIPES SLEEVES,ETC.,HAS BEEN ALL BARS FOR BEAMS AND COLUMN HAS BEEN LAPPED WITH A LENGTH OF 30 X BAR DIAMETER.
EMBEDDED IN CONCRETE. ALL BARS FOR SUSPENDED SLAB HAS BEEN LAPPED WITH A LENGTH OF 40 X BAR DIAMETER
4. IT WAS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORING & BRACING NO MORE THAN 50% OF THE REBARS HAS BEEN SPLICED WITHIN THE REQUIRED LAP LENGTH.
OF THE STRUCTURE FOR ALL LOADS THAT HAS IMPOSED DURING CONSTRUCTION. 90° HOOKS WITH 12 X BAR DIAMETER EXTENSION(SPECIFICALLY FOR BEAMS) HAS BEEN
B. CONCRETE &REINFORCEMENT ANCHORED
1. ALL MATERIALS AND WORKMANSHIP HAS BEEN CONFORM WITH THE LATEST BUILDING CODE OF
AMERICAN CONCRETE INSTITUTE (ACI-318)
2. ALL CONCRETE HAS BEEN DEVELOP A MIN. COMPRESSIVE STRENGTH AT THE END OF TWENTY
EIGHT (28) DAYS W/ CORRESPONDING MAXIMUM SIZE AGGREGATE & SLUMPS AS FOLLOWS

LOCATION 28 DAYS STRENGTH MAX. SIZE AGGREGATE MAX.SLUMP


(CRASHED ROCK)
FOUNDATION 3000 PSI(20.70 MPa) 1 IN. ( 24mm ) 5 IN. ( 130mm)
12 THK. EXPANSION JOINT 1-10 mm Ø VER. BARS
COLUMNS 3000 PSI(20.70 MPa) 3
4 IN. ( 19mm ) 5 IN. ( 130mm) w/ MASTIC FILLER CHB WALL
3
SUSPENDED BEAMS 3000 PSI(20.70 MPa) 4 IN ( 19mm ) 5 IN. ( 130mm) SEE CONSTRUCTION NOTES FOR THE SIZE
AND SPACING OF VER. AND HOR. BARS
3
SUSPENDED SLABS 3000 PSI(20.70 MPa) 4 IN. ( 19mm ) 5 IN. ( 130mm)

SLAB ON GRADE 3000 PSI (20.70 MPa) 1 IN. (19mm ) 4 IN (100mm )

400.00
3
R.C Piles 4000 PSI (20.70 MPa) 4 IN (19mm ) 5 IN. (130mm )

3. ALL REINFORCING BARS HAS BEEN CONFORM TO ASTM A615 GRADE 60 (414 MPa) SEE CONSTRUCTION NOTES FOR THE SIZE
FOR 20mmØ & LARGER BARS AND GRADE 40 (276 MPa) FOR SMALLER BARS AND SPACING OF VER. AND HOR. BARS
4. IN GENERAL THE LATEST EDITION OF ACI-315, MANUAL OF STANDARD PRACTICE DETAILING
REINFORCED CONCRETE STRUCTURES HAS BEEN ADHERED TO UNLESS OTHERWISE SHOWN
OR NOTED.
5. MINIMUM CONCRETE COVER FOR REINFORCING STEEL WAS MAINTAIN AS FOLLOWS
CHB WALL OPENING OR END WALL
3
SUSPENDED SLABS 4 IN. ( 19mm )
1
SLAB ON GRADE 1 IN. ( 38mm )
2
WALLS ABOVE GRADE 1 IN. ( 25mm )
BEAM STIRRUPS AND COLUMN TIES
WHERE CONCRETE IS EXPOSED TO
1 21 IN. ( 38mm ) CORNER WALL
EARTH BUT POURED AGAINST FORMS 2 IN. ( 50mm )
WHERE CONCRETE IS DEPOSITED RC COLUMN
DIRECTLY AGAINST EARTH 3 IN. ( 75 mm)
CHB WALL
6. SPLICES HAS BEEN SECURELY WIRED TOGETHER & SHALL LAP OR EXTEND IN ACCORDANCE DOWEL BARS TO MATCH
W/ TABLE 1 (TABLE OF LAP SPLICE & ANCHORAGE LENGTH) UNLESS OTHERWISE SHOWN CHB HOR. BARS
ON DRAWINGS, SPLICES HAS BEEN STAGGERED WHENEVER POSSIBLE
7. ALL ANCHOR BOLT,DOWELS, AND OTHER INSERTS,HAS BEEN PROPERLY POSITIONED &
SECURED IN PLACE PRIOR TO PLACING OF CONCRETE.
8. CONTRACTOR HAS NOTE AND PROVIDE ALL MISCELLANEOUS CURBS,SILLS,STOOLS 1-10 mm Ø VER. BAR 12 THK. EXPANSION JOINT
EQUIPMENT'S AND MECHANICAL BASES THAT ARE REQUIRED BY THE ARCHITECTURAL, w/ MASTIC FILLER
ELECTRICAL, AND MECHANICAL DRAWINGS.
12 THK. EXPANSION JOINT
9. ALL CONCRETE HAS BEEN KEPT MOIST FOR A MINIMUM OF SEVEN CONSECUTIVE DAYS 400.00

IMMEDIATELY AFTER POURING BY THE USE OF WET BURLAP FOG SPRAYING,CURING 400.00
w/ MASTIC FILLER 400.00

COMPOUNDS OR OTHER APPROVED METHODS.


10. STRIPPING OF FORM AND SHORES:

FOUNDATION 24 HRS
SUSPENDED SLAB EXCEPT WHEN 400.21

ADDITION LOADS ARE IMPOSED 8 DAYS SEE CONSTRUCTION NOTES


WALLS 18 HRS FOR THE SIZE AND SPACING
BEAMS 14 DAYS OF VER. AND HOR. BARS

C.MASONRY AND CONCRETE BLOCKS INTERSECTING R.C. CORNER WALL


1. ALL NON-LOAD BEARING TYPE CONCRETE BLOCKS HAS A UNIT WEIGHT NOT TO
EXCEED 80 PCF. FOR LOAD BEARING TYPE, TYPE CONCRETE BLOCKS, A MINIMUN
COMPRESSIVE STRENGTH OF 2.41 MPA HAS BEEN DEVELOPED.
2. 1-10 mm Ø BARS AT CORNERS,INTERSECTIONS, END OF WALLS AND EACH INTERSECTING WALL DETAIL
SIDE OF OPENINGS WAS PROVIDED.
3. LINTEL BEAMS HAS BEAR AT LEAST 8 INCHES (200mm) ON EACH SIDE OF MASONRY
WALL OPENING
4. WALL REINFORCEMENT HAS BEEN FOLLOWED.
A TYPICAL CONNECTION DETAIL OF MASONRY WALL
SCALE: NTS
S 1
WALLS THICKNESS VERTICAL REINFORCEMENT HORIZONTAL REINFORCEMENT
8 IN. (200mm) 12mmØ @ 400mm 10mmØ @ 600mm
6 IN. (150mm) 10mmØ @ 600mm 10mmØ @ 600mm
5 IN. (125mm) 10mmØ @ 600mm 10mmØ @ 600mm
4 IN. (100mm) 10mmØ @ 600mm 10mmØ @ 600mm

LAPPED A MINIMUM OF 30 BAR DIAMETERS WHERE SPLICE

CUBO Juan Miguel R. Santos Fritz D. Natividad Bulacan Standard


9071 Tambo Kulit Brgy. Tambo Kulit Indang Cavite
-
- STRUCTURAL PLAN
S-01
A A' B C
A A' B C

B
S-02
C-2 C-2 C-2
C2-F1 C2-F1 C2-F1 1
1 WF-1 WF-1
2"x6" Treated Lumber (Sill plate)
Placed on 6" CHB

WF-2

WF-1
2"x8" Treated Lumber (Sill plate)
WF-1
Placed on 2- 4" CHB
GROUND COVERED
W/ 6 MIL
POLYETHYLENE BULACAN UNIT
SHEET
C-1 C-1 C-1
C1-F1 C1-F1 C1-F1
WF-1 WF-1
2
2

WF-1
WF-1

WF-2
2"x8" Treated Lumber (Sill plate)
Placed on 2- 4" CHB

C-2 C-2 C-2


C2-F1 C2-F1
C2-F1
3
3 WF-2 WF-2
A
2"x6" Treated Lumber (Sill plate)
Placed on B-1 S-02

B-1 DECK B-1

C1-F2 C1-F2 C1-F2


4
4 C-1 B-1 C-1 B-1 C-1

Foundation Plan Floor Framing Plan


Scale 1:30 Scale 1:30

CUBO Juan Miguel R. Santos Fritz D. Natividad Bulacan Standard


9071 Tambo Kulit Brgy. Tambo Kulit Indang Cavite
-
- STRUCTURAL PLAN
S-02
4-12mm dia. Vertical Bars
4-12mm dia. Vertical Bars 40mm Concrete Cover 4-12mm dia. Vertical Bars
40mm Concrete Cover 5-12mm dia.BOTHWAYS 40mm Concrete Cover
5-12mm dia.BOTHWAYS 5-12mm dia.BOTHWAYS

10mm dia. Lateral Ties 1@ 50mm,


10mm dia. Lateral Ties 1@ 50mm, 4@ 100mm REST @ 200mm 10mm dia. Lateral Ties 1@ 50mm,
4@ 100mm REST @ 200mm 4@ 100mm REST @ 200mm

1 1
2"Dia. x12" L Bolt w/ washer 2"Dia. x12" L Bolt w/ washer
1
2"Dia. x12" L Bolt w/ washer Spaced @ 450mm O.C. Spaced @ 450mm O.C.
Spaced @ 450mm O.C. FLOOR JOIST 2"X3" ENGINEERED BAMBOO FLOOR JOIST 2"X3" ENGINEERED BAMBOO
FLOOR JOIST 2"X3" ENGINEERED BAMBOO SILL PLATE 2"X6" LUMBER SILL PLATE 2"X6" LUMBER
SILL PLATE 2"X6" LUMBER

B-1

4-12mm VERTICAL BARS 4-12mm VERTICAL BARS


10mm dia. Lateral Ties 1@ 50mm, 10mm dia. Lateral Ties 1@ 50mm,
4-12mm VERTICAL BARS 40mm CONCRETE COVER 40mm CONCRETE COVER
10mm dia. Lateral Ties 1@ 50mm, 4@ 100mm REST @ 200mm 4@ 100mm REST @ 200mm
40mm CONCRETE COVER 4@ 100mm REST @ 200mm

100mm THK GRAVEL BEDDING 100mm THK GRAVEL BEDDING


100mm THK GRAVEL BEDDING

C2-F1 Detail C1-F2 Detail


C1-F1 Detail NOT TO SCALE NOT TO SCALE
NOT TO SCALE

1
2" Dia. X12" L Bolt w/ washer @ 450mm O.C.
1
2" Dia. X12" L Bolt w/ washer @ 450mm O.C.
2-FLOOR JOIST 2"X3"
FLOOR JOIST 2"X3"
ENGINEERED BAMBOO
SILL PLATE 2"X6" LUMBER ENGINEERED BAMBOO
SILL PLATE 2"X8" LUMBER BEAM ID BEAM DETAILS
10mm HORIZONTAL BAR
every 3rd Layer 10mm HORIZONTAL BAR
2" THK CONCRETE CAP W/ 2-10mm dia. every 3rd layer
2" THK CONCRETE CAP W/ 2-10mm dia.
Horizontal Bars and C-bar @300mm O.C. Horizontal Bars and C-bar @300mm O.C. 2-16mm dia. TOP BAR
6" CHB WALL WITH 10mm dia. 2-4" CHB WALL WITH 10mm dia.
VERTICAL BARS @ 600mm O.C VERTICAL BARS @ 600mm O.C
10mm dia.Stirrups 1@50mm,

B-1 4@100mm Rest @ 200mm O.C

2-16mm dia. BOTOOM BAR


40mm Concrete Cover
2-12mm dia. HORIZONTAL BARS 2-12mm dia. HORIZONTAL BARS
WITH 10mm dia. LATERAL TIES @ WITH 10mm dia. LATERAL TIES @
300mm O.C 300mm O.C

Wall Footing 1 Details Wall Footing 2 Details


NOT TO SCALE NOT TO SCALE

CUBO Juan Miguel R. Santos Fritz D. Natividad Bulacan Standard


9071 Tambo Kulit Brgy. Tambo Kulit Indang Cavite
-
- STRUCTURAL PLAN
S-03
1
2"Dia. L Bolt w/ 2"x2"x0.229" Steel Plate
FLOOR JOIST 2"X3" ENGINEERED BAMBOO Spaced @ 450mm O.C. 1
2"Dia. x12" L Bolt w/ washer
SILL PLATE 2"X6" LUMBER FLOOR JOIST 2"X3" Spaced @ 450mm O.C.
ENGINEERED BAMBOO WALL
2" THK CONCRETE CAP
W/ 2-10mm dia. Horizontal Bars and C-bar SILL PLATE 2"X6" LUMBER
@300mm O.C.
6" CHB WALL WITH 10mm dia.
VERTICAL BARS @ 600mm O.C

B-1

2-12mm dia. HORIZONTAL BARS


WITH 10mm dia. LATERAL TIES @
300mm O.C

100mm THK GRAVEL BEDDING

Wall Footing to Column Connection A DECK BLOW UP DETAIL


Not to Scale
S-02 Not to Scale
1
2"Dia. L Bolt w/ 2"x2"x0.229" Steel Plate
12MM THK ENGINEERED Spaced @ 450mm O.C.
BAMBOO PLYBOARD
SILL PLATE 2"X6" LUMBER
FLOOR JOIST 2"X3" ENGINEERED BAMBOO
2" THK CONCRETE CAP
W/ 2-10mm dia. Horizontal Bars and C-bar
@300mm O.C.
12MM THK ENGINNERED 6" CHB WALL WITH 10mm dia.
BAMBOO PLYBOARD VERTICAL BARS @ 600mm O.C

6 mil Polyethylene Sheet


2X3 ENGINEERED BAMBOO
FLOOR JOIST 50mm thk Sand Bedding

SILL PLATE

6mil Polyethylene Sheet covering the


whole unit except the deck 2" THK GRAVEL COVER &
6" THK GRAVEL
2" THK CONCRETE CAP BEDDING AT THE
EATH FILL
W/ 2-10mm dia. Horizontal Bars and C-bar 4" DIA. PERFORATED
PIPES (TO BE INSTALLED
@300mm O.C. IN FLOOD PRONE AREAS)

ANCHOR BOLT W/ SINK HOLE

100mm THK GRAVEL BEDDING

Connection Blow up B Polyehtylene Sheet Placement


Not to Scale
S-02 Not to Scale

CUBO Juan Miguel R. Santos Fritz D. Natividad Bulacan Standard


9071 Tambo Kulit Brgy. Tambo Kulit Indang Cavite
-
STRUCTURAL PLAN
S-04