SW Oil Break 26020
SW Oil Break 26020
Switches
Electrical Apparatus
Electrically Operated, Types NR, NRV,
VR, VCR, VLR, & TSC 260-20
Figure 1. 85670KMA
2
260-20
Catalog
Description Number
Type VR, VCR, VLR, VRV Switches (cont’d)
17 in. creepage bushing (Types VR, VCR, VLR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA190VR
17 in. creepage bushing on switches that include a KA217VR
load-transfer accessory (Types VR, VCR, VLR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA170GV1
120 Vac low-voltage surge arrester
Switch with standard operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA88VR
Switch with quick-close operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA134VR
Operator cabinet heater with on/off switch; 50 W
120 Vac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA97VR1
240 Vac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA97VR2
Type TSC Switch
Auxiliary switch
One-stage; two independent contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA51TSC1
Four-stage; eight independent contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA51TSC4
240 Vac control (120 Vac is standard) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA54TSC
Load-transfer wiring accessory for use with Type S load-transfer
control without fault-block feature; includes auxiliary switch,
special wiring, receptacle, and mating plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA5TSC2
Load-transfer wiring accessory for use with Type S load-transfer
control with fault-block feature; includes auxiliary switches,
internal BCTs, special wiring, receptacles, and mating plugs . . . . . . . . . . . . . . . . . . . . . KA5TSC1
Slip-on bushing current transformer kit; one BCT per kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA712L2-3
Mounting Equipment
Catalog
Description Number
For Types NR, NCV
Crossarm mounting hanger; one required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA39H
For Types VR, VCR, VLR, VRV
Types VR, VCR, VLR switches
Double-crossarm bracket or substation hanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA19H3
Broadside-mounting pole hanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA116H3
End-mounting pole hanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA114H3
Substation mounting frame (mounting frame
KA584R1 and switch mounting kit KA720VR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA194VR
Kit for mounting switch in KA584R1 substation mounting frame . . . . . . . . . . . . . . . . . . . KA720VR
Tank-lifting windlass for substation mounting frame KA194VR . . . . . . . . . . . . . . . . . . . . KA584R2
Type VRV switch
Direct-pole-mounting hanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA146W3
Types VR, VCR, VLR, VRV switches
Surge arrester mounting bracket for KA116H3 and KA146W3 hangers . . . . . . . . . . . . KA126H3
Surge arrester mounting bracket for KA116H3 and KA146W3 hangers; set of 2 . . . . . . . . KA126H3-2
For Type TSC
Direct-pole mounting hanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA2TSC1
Capacitor-structure-mounting hanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA2TSC2
Windlass for pole- and capacitor-structure-mounting hangers . . . . . . . . . . . . . . . . . . . . . . . KA2TSC3
3
Types NR, NRV, VR, VCR, VLR, VRV & TSC Oil Switches
83507KMA
Figure 2.
Untanked Type NR switch.
4
260-20
Ratings and Specifications TABLE 1 Mechanical Counter: A three-digit
Electrical Data (Control) counter that cumulatively counts
Type Type
Description Rating switch operations. Mounted under
Description NR NRV
Nominal operating voltage the sleet hood, the counter is actuat-
Nominal voltage class,
(Vac) . . . . . . . . . . . . . . . 120 ed by movement of the operating
kV rms 14.4 20*
Operating voltage range handle.
Rated maximum voltage, (Vac) . . . . . . . . . . . . . . . 95 to 130 Actuating Motor Operating
kV rms 15.0 22 Closing-motor current Voltage: The standard actuator
Impulse withstand (BIL), (A) . . . . . . . . . . . . . . . . .. .9 motor requires 120 Vac operating
kV cress 95† 125 Switch response time, power. An accessory is available for
60 Hz dielectric withstand opening (sec) . . . . . . . . 4.0 240 Vac operation.
Dry, 1 minute, kV 35 60 Switch response time, NOTE: Five-pin plugs accommodate cables having
Wet, 10 seconds, kV 30 50 .375-.500 inch O.D. and a No. 12 maximum wire
closing (sec) . . . . . . . . . 0.5
size. Six-pin plugs accommodate cables having
Continuous current, A 200 60 .500-.625 inch O.D. and a No. 16 maximum wire
Rated capacitive switching
current, A 200 60
Accessories size.
The Types NR and NRV switches
Inductive load switching
can be tailored to meet various appli-
current, A
cation requirements through the use
75 to 100% power factor 200 60
of factory-installed accessories.
50 to 75% power factor 100 60
Relay for Two-Wire Control: A
Under 50% power factor 50 60
single-pole, double-throw relay
Rated making current, A
installed in the actuator permits
asymmetrical** 9000 9000
opening and closing commands to
Momentary current, A
be transmitted on two wires using a
asymmetrical 9000 9000
single-pole, single-throw switch. If
Short-time current ratings, A
plug and receptacle accessories
sym.
are used for control wiring, this
1/2 second 6000 6000
accessory requires the five-pin,
1 second 4500 4500
four-conductor type.
* Can be used for switching solidly grounded
Holding Switch: Installed in the
capacitor banks on 20/34.5 kV systems. actuator housing, this accessory
** Applies to electrical closing only. reduces to one second the mini-
† For 125 kV BIL version of the Type NR switch, mum time the control circuit must
available as an accessory, 60 Hz dielectric with- be energized to effect an opening
stand; dry, 1 minute is 42 kV; wet, 10 seconds is or closing operation. If plug and
36 kV.
receptacle accessories are used
for control wiring, this accessory
requires the five-pin, five-conductor
type.
Plug and Receptacle
Assemblies: Mounted in the
bottom of the actuator housing,
receptacles provide a convenient,
weather-proof connection to switch
control circuits. The number of
conductors tabulated for the recep-
tacles listed indicates the number of
pins wired to the actuator terminal
strip. Plugs must be specified
separately.
Receptacles: Five-pin, three
conductors wired (standard); five-
pin, four conductors wired; five-pin,
five conductors wired; six-pin, six
conductors wired.
Plugs: Five-pin (for five-pin
receptacles); six-pin (for six-pin
receptacles).
Low-Voltage Surge Arresters:
Installed in the actuator housing,
the arresters protect the switch
controls from transient overvoltage.
Arresters cannot be installed when
the relay for two-wire control
accessory is included.
5
Types NR, NRV, VR, VCR, VLR, VRV & TSC Oil Switches
Figure 3.
Type NR (standard & 17” creepage bushing).
Figure 4.
Type NR (125 kV BIL). Type NRV (standard).
6
260-20
Switch Dimensions (in.)
Type Bushing A B C D E
NR Standard 7-3/8 12 20 15 15-1/2
NR 17” 7-3/4 14-1/4 22-1/4 17-1/4 17-3/4
Creepage
NR 125 kV 12-5/8 14 22 17 17-1/2
BIL
NRV Standard 12-5/8 14 22 17 17-1/2
Figure 5.
For crossarm mounting, one KA39H bracket is required.
7
Types NR, NRV, VR, VCR, VLR, VRV & TSC Oil Switches
Figure 7. 83491KMA
Figure 8. 83468KMA
8
260-20
Description of Switch
Operation
STANDARD ACTUATOR
These switches are equipped with a
motor-operated actuator mecha-
nism (Figure 9) for remote closing.
Remote tripping is initiated by
energizing a trip-open solenoid
which unlatches the spring-loaded
operating mechanism to open the
main switch contacts.
Subsequent closing is accom-
plished by operating the motor which
loads the opening springs, latches
the operating mechanism, and
extends the closing spring until it
overtoggles and closes the main
switch contacts. Operating time of 83469KMA
the closing circuit is approximately Figure 9.
10 seconds. Standard actuator.
QUICK-CLOSE ACTUATOR
When equipped with the quick-close
accessory (Figure 10), the main
switch contacts close in 2.5 to 5
cycles after energizing the closing
circuit (compared to 10 seconds for
the standard control). However, at
least 10 seconds must elapse
between an opening and closing
operation to allow the motor opera-
tor to preload the closing springs.
The accessory includes a solenoid
operated latch to trip the preloaded
closing mechanism and a cam-
operated cutout switch to allow
preloading of the closing mechanism.
9
Types NR, NRV, VR, VCR, VLR, VRV &TSC Oil Switches
Figure 12.
Outline dimensions for Type VR, VCR, and VLR oil switches.
10
260-20
Figure 13.
Mounting dimensions of Type VR,
VCR, and VLR oil switches in
KA19H3 double crossarm bracket
or substation hanger.
Figure 15.
Mounting dimensions of Type VR, VCR, and VLR oil switches KA194VR
substation frame with KA584R2 windlass.
Figure 14.
Mounting dimensions of Type VR,
VCR, and VLR oil switches on
KA116H3 broadside-mounting
pole frame.
11
Types NR, NRV, VR, VCR, VLR, VRV & TSC Oil Switches
Figure 16.
Outline dimensions Type VRV switch.
12
260-20
Figure 17.
Type VRV switch in KA146W3 single-pole mounting hanger.
13
Types NR, NRV, VR, VCR, VLR, VRV & TSC Oil Switches
TYPE TSC SWITCH release of preloaded springs. The sequence. The clutch is disen-
The Kyle Type TSC switch is a three- double-blade moving contacts, gaged when the motor circuit is
phase, oil-filled device designed pinned to the shaft, are rotated in deenergized to provide the switch
specifically for capacitor bank 90° increments into and out of with local manual operating
switching applications on distribution spring-load, finger-type stationary capability.
systems rated up to 34.5 kV. With a contacts. The fast rotary action of the The TSC switch is manually
capacitive current switching rating of shaft provides contact opening and operated by a single downward pull
135 A and momentary and latching contact closing times of about five- of the manual operating handle
ratings of 12,000 asymmetrical A, the eighths of one cycle. The operating located under the sleet hood.
Type TSC can switch single-bank springs are preloaded by an electric
capacitors rated up to 6000 kvar. The motor and reduction gear train drive Electrical Operation
switch also has an inductive continu- through the point of release to The Type TSC switch is electrically
ous and load-switching rating of 300 provide this fast rotary action. Total opened and closed by means of
A, maximum, at 75 to 100% lagging operating time for the motor to load customer-furnished 120 Vac 60 Hz
power factor. and release the springs for either a auxiliary power controlled by some
The Type TSC switch is equipped close or open operation is 15 seconds, SPDT switching device.
with a simple, fast-response mecha- maximum. A solenoid-operated
nism that simultaneously operates clutch engages the motor drive to the
double-break rotary contacts on all operating mechanism of the switch
three phases from a common shaft when the motor is energized during a
operated by shaft operated by the remote electrical operating
85671KMA
Figure 18.
Untanked Type TSC oil switch.
14
260-20
85674KMA
Figure 19.
Type TSC switch indicator and operating levers.
85673KMA
Figure 20
Close-up of operating mechanism.
15
Types NR, NRV, VR, VCR, VLR, VRV & TSC Oil Switches
16
260-20
Outline and Mounting Dimensions
Figure 21.
Outline dimension Type TSC switch.
17
Types NR, NRV, VR, VCR, VLR, VRV & TSC Oil Switches
Mounting Information
Figure 22.
Direct-pole mounting hanger KA2TSC1.
Figure 23.
Capacitor-structure-mounting hanger KA2TSC2.
18
260-20
19
Types NR, NRV, VR, VCR, VLR, VRV & TSC Oil Switches
KDL