Solis-(25-40)K-5G, Solis-(40-50)K-HV-5G

Solis Three Phase Inverters

Features: 360 degree


▶▶ Over 98.8% Max. effciency
▶▶ Wide voltage range and low startup voltage
▶▶ 3/4 MPPT design with precise MPPT algorithm
▶▶ THDi<3%, low harmonic distortion against grid
▶▶ Anti-resonance, supporting over 6MW parallelled in one transformer
629mm

▶▶ Perfect commercial site monitoring solution


▶▶ 130% DC overload ratio, 13A input for each PV string
▶▶ Strings intelligent monitoring, Smart I-V Curve Diagnosis supported 647mm 252mm

▶▶ Fuse free design to avoid fire hazard


▶▶ Type II surge arrester for both DC and AC
▶▶ Natural convection, Fan-less design, longer lifespan Model:
▶▶ Leakage current repression technology 400V: Solis-25K-5G Solis-30K-5G
▶▶ Volt-watt work mode integrated Solis-33K-5G Solis-36K-5G
▶▶ DC input reverse alarm Solis-40K-5G
▶▶ Intergrated Export Power Manager (EPM) 480V: Solis-40K-HV-5G Solis-50K-HV-5G
Datasheet
Model Name Solis-25K-5G Solis-30K-5G Solis-33K-5G Solis-36K-5G Solis-40K-5G Solis-40K-HV-5G Solis-50K-HV-5G
Input DC
Recommended max. PV power 33kW 39kW 43kW 47kW 52kW 52kW 65kW
Max. input voltage 1100V
Rated voltage 600V
Start-up voltage 180V
MPPT voltage range 200-1000V
Max. input current 26A/26A/26A 4*26A
Max. short circuit current 40A/40A/40A 4*40A
MPPT number/Max. input strings number 3/6 4/8
Output AC
Rated output power 25kW 30kW 33kW 36kW 40kW 40kW 50kW
Max. apparent output power 27.5kVA 33kVA 36.3kVA 39.6kVA 44kVA 44kVA 55kVA
Max. output power 27.5kW 33kW 36.3kW 39.6kW 44kW 44kW 55kW
Rated grid voltage 3/N/PE, 220/380V, 230/400V 3/PE, 480V
Rated grid frequency 50/60Hz
Rated grid output current 38.0A/36.1A 45.6A/43.3A 50.1A/47.6A 57.7A/52.0A 60.8A/57.7A 48.1A 60.1A
Max. output current 41.8A 50.2A 55.1A 60.2A 66.9A 53.0A 66.2A
Power Factor >0.99 (0.8 leading - 0.8 lagging)
THDi <3%
Efficiency
Max. efficiency 98.8%
EU efficiency 98.3%
Protection
DC reverse-polarity protection Yes
Short circuit protection Yes
Output over current protection Yes
Surge protection DC Type II / AC Type II
Grid monitoring Yes
Anti-islanding protection Yes
Temperature protection Yes
Strings monitoring Yes
I/V Curve scanning Yes
Anti-PID function Optional
Integrated DC switch Optional
General Data
Dimensions (W*H*D) 647*629*252 mm
Weight 45kg
Topology Transformerless
Self consumption <1W (night)
Operating ambient temperature range -25 ~ +60°C
Relative humidity 0-100%
Ingress protection IP65
Cooling concept Natural convection
Max. operation altitude 4000m
Grid connection standard VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99, EN 50549-1/-2, IEC61727, DEWA
Safety/EMC standard IEC62109-1/-2, EN61000-6-2, EN61000-6-3
Features
DC connection MC4 connector
AC connection OT terminal
Display LCD, 2×20 Z
Communication RS485, Optional: Wi-Fi, GPRS

Sold in India by: Loop Solar | Ph: 9971136369 | E: [email protected] | W: www.loopsolar.com