1550 1700 CFM 1700 CFM EACH 300 X 300 X 05 NOS.

-
COUNTER-6 300 X 250- 1000 CFM
CONNECTED TO SCRUBBER
450 CFM EACH
PLACED AT TERRACE
HOOD-6, 2850
DISPLAY KITCHEN
EXHAUST(TYP)
AIR OPENING WITH VCD
375 X 375 X 06 NOS.-
MINIMUM (TYP)
HOOD-9,CONVECTION OVEN
9000
EXHAUST AIR OPENING WITH VCD
375 X 375 X 01NO.-
COLLAR SIZE - 400 X 150 9000
(TYP)
3650
(TYP)
ALL BOH AREA
1165 CFM EACH
3 FEET WIDE AND 12 FEET
1000 CFM

1500
SUPPLY AIR GRILLE WITH VCD
300 X 300 X 10 NOS.- 06-SH-226
HOOD-6, DISPLAY KITCHEN HOOD-9, CONVECTION OVEN
300 CFM EACH
FRESH AIR COLLAR WITH VCD
1100 X 200 X 05 NOS.- LENGTH SHAFT REQUIRED FOR
FRESH AIR COLLAR WITH VCD
750 X 200 X 01 NO.- COLLAR SIZE - 400 X 150

3550
BAKERY
COUNTER-7

3100
1150 CFM EACH 700 CFM T.O.DUCT=4800MM

PASSAGE R EXHAUST AND FRESH AIR DUCTS.R 1# NO. HI WALL


R UNIT-
1.5 TR-600 CFM
R 06-SH-225
PIPE FLANGE
B.O.DUCT=4150MM
SUPPLY AIR DUCT
6350
2400 5250 2050 1250 5225 SUPPLY & RETURN SHAFT. 350 X 600- 3000 CFM
IF-02 MAIN ENTRY P.O.S. CONNECTED TO EXISTING AHU
PLACED AT TERRACE
0 X 200 250 X 200 250 X 200 250 X 200 250 X 200 H-9
0 CFM 350 CFM GD 350 CFM 350 CFM 350 CFM ELE.PANEL B.O.DUCT=4000MM
0 MM T.O.DUCT=5250MM B.O.F.C. 3950 MM
T.O.DUCT=5250MM T.O.DUCT=5250MM B.O.F.C. 3950 MM T.O.DUCT=4800MM B.O.DUCT=3550MM T.O.DUCT=4800MM 300 X 250-1000 CFM FRESH AIR DUCT
B.O.DUCT=4800MM B.O.DUCT=4600MM B.O.DUCT=4600MM B.O.DUCT=4450MM 200 X 400-1000 CFM B.O.DUCT=4250MM 800 X 550- 13500 CFM
H-5 GRILL TANDOOR
350 X 300-1200 CFM
ONLINE COUNTER 350 X 500-2400 CFM
WALL
DN
(TYP)

T.O.DUCT=4800MM
WALL
2100

MOUNTED

750 X 250-2500 CFM


T.O.DUCT=4800MMFD
SPEAKER MOUNTED

650 X 400-4000 CFM ENTRANCE


650 X 600-7150 CFM
SPEAKER

350 X 600-2850 CFM IF-05 CONNECTED TO AIR WASHER


LOBBY
B.O.DUCT=4250MM HOT B.O.DUCT=3850MM
PLACED AT TERRACE

B.O.C=3250MM
T.O.C=3400MM
2550 D2 800 X 250-2400 CFM KITCHEN POT
R T.O.DUCT=4300MM 800 X 550 FD FD09a
BAKERY T.O.DUCT=3800MM

200 X 400-1000 CFM


B.O.DUCT=3550MM
B.O.DUCT=4000MM
T.O.DUCT=4300MM WASH
UP 9650 CFM EXHAUST AIR DUCT
B.O.DUCT=4000MM B.O.DUCT=3750MM B.O.DUCT=3750MM
950 X 600-11250 CFM

UP 600 X 500- 5500 CFM


B.O.DUCT=4200MM
T.O.DUCT=4850MM

5900
DN T.O.DUCT=4800MM

B.O.F.C. 2700 MM
NGT-30
B.O.F.C. 3950 MM T.O.DUCT=5350MM UP
T.O.DUCT=4775MM 600 X 200-1000 CFM DN CONNECTED TO SCRUBBER
Ø40 PIPE RISE (TYP)
NGT-14
B.O.DUCT=4550MM H-7 H-8 NGT-14

RISE B.O.DUCT=4900MM B.O.DUCT=4225MM


DISPLAY KITCHEN PLACED AT TERRACE
DETAIL-J2
T.O.DUCT=4700MM 700 X 250 700 X 550-7250 CFM 500 XBUTCHERY
900- 9500 CFMD1
DETAIL-J1 D3 DN
D3 STAFF
EXHAUST AIR DUCT
DETAIL-J3 DN UP B.O.DUCT=4250MM TOILET
B.O.F.C. 3950 MM B.O.F.C. SS pipe
discharge tube
T.O.DUCT=4800MM HK STORAGE
500 X 900- 9500 CFM
3000 MM
DESSERT DISH T.O.DUCT=4800MM Heat detector
sensitive tube

B.O.DUCT=3850MM CONNECTED TO SCRUBBER


DN WASH

P.O.S. through
H-6
Nozzles as
per req.

CASHIER COUNTER B.O.DUCT=4500MM


Exhaust
(TYP)

pass
Hood
5000

750 X 600-9500 CFM Nozzles as


per req.
NGT-14
PLACED AT TERRACE
T.O.DUCT=4200MM T.O.DUCT=4800MM
B.O.F.C. 4050 MM B.O.DUCT=3900MM B.O.DUCT=4150MM

SOUP
NGT-20
P.O.S. NON.VEG. COLD VEG.
P.O.S. PLATE 1400 X 900-31500 CFMD2 SUPPLY AIR DUCT-1400 X 900

LOCKERS
STAFF
T.O.DUCT=4850MM T.O.DUCT=4850MM FOR 2500 FPM- 31500 CFM
T.O.DUCT=5150MM
B.O.DUCT=4500MM B.O.DUCT=4200MM 1400 X 600 SALAD
1400 X 800-25850 CFM B.O.DUCT=4200MM CONNECTED TO EXISTING AHU
19550 CFM 600 X 400-4500 CFM
750 X 300-3300 CFM 750 X 600-8300 CFM T.O.DUCT=5050MM PLACED AT TERRACE
T.O.DUCT=5050MM

B.O.DUCT=4300MM

B.O.DUCT=4300MM
LIVE GRILL B.O.F.C. 4050 MM

T.O.DUCT=4550MM

T.O.DUCT=4550MM
B.O.DUCT=4200MM

300 X 200-600 CFM

300 X 200-600 CFM


COUNTER T.O.DUCT=4850MM B.O.DUCT=4600MM
AL12 DN
H-3 T.O.DUCT=5050MM
B.O.DUCT=4200MM
B.O.DUCT=4600MM B.O.F.C. 4050 MM B.O.F.C. 12'-0" STAFF HAND
WASH
600 X 400-4500 CFM D4A STAIRCASE - 05
06-ST-05
H-4
FD11 SERVICE

IF-17
D4 FIRE
T.O.DUCT=5150MM T.O.DUCT=5150MM ENTRY EXHAUST AIR DUCT
600 X 500-5500
WALL CFM
PLANTER PLANTER
WALL PLANTER 600 X 500-5500 CFM EXIT
B.O.DUCT=4600MM B.O.DUCT=4600MM
WALL
MOUNTED
SPEAKER
MOUNTED
SPEAKER
MOUNTED
SPEAKER
WALL
MOUNTED
SPEAKER
400 X 900- 5500 CFM
B.O.F.C. 11'-6" B.O.F.C. 11'-6" B.O.F.C. 11'-6" B.O.F.C. 11'-6" FD IF-02 CONNECTED TO SCRUBBER
FLOOR DB PLANTER
P.O.S.
P.O.S.
PLACED AT TERRACE
T.O.DUCT=4800MM
B.O.DUCT=4350MM
RETURN AIR GRILLE FULL HEIGHT

TFA GRILL REQUIRED