A L A R M A N N U N C I A T O R S

MBAS 0600 *

1D 1D 1D 2D 2D 2D

14B0SPO 10B8SPO 10B6SP0 28B0S0O 22B10SP0 20B16SPO

MBAS 0600 is a improved version of earlier MBAS 9400 and is available for 4 to 32 windows

The Functional Features The Design Features System Enclosures


• Fixed Sequence ( S1/S2/S3/S4) • Single chip microcontroller logic The MBAS 0600 annunciation systems is configured in multiples
• Potential free dry contact inputs • Opto isolated inputs and outputs
of four basic ABS moulded enclosures
• Super Bright LED window illumination
• NO/NC inputs selectable configuration • High Noise immunity / isolation Size 1 D Size 2 D Size 3 D Size 4 D
• Relay output for external Audible • Switch mode power supply
rd
Hooter 3 Relay (optional) for either of • Self surveillance watchdog LED
below mentioned features The Constructional Flexibility
a) Ring back hooter • Conforming to DIN panel cutouts
b) Supervisory control • Replaceable snap-on window capsules
• Two different window size Basic Standard Enclosures
• Minilec Standard Communication
Protocol • Moulded enclosures

Back view showing Terminal details

Optional Features • Fault Follower contact output


• Any custom built operating per fault Input (NO or NC) DIP for
RS 232
sequences • Supply fail indication / NO/NC &
Port
• Manned / Unmanned function annunciation Built-in Fault Input Grouping
• MODBUS RTU/ASCII Protocol • Built-in control push buttons Terminals

Manned /
Functional Block Diagram Unmanned

Repeat
Relay Output
Terminal Relays

Fuse DIP Switches


Power
for
Supply
Sequence
Selection

PC Side software

52
A L A R M A N N U N C I A T O R S
MBAS 0600 *

3D 3D 4D 4D

312B0SPO 30B24SPO 416B0SPO 40B32SPO

Connection Diagram (FOR MAX. 32 POINT MBAS 0600.) TECHNICAL SPECIFICATIONS :


Note: Mention specific voltage
M
Supply Voltage 24 / 30 / 48 / V DC, 20-60 V DC, 90-270 V AC / DC
F1 ( Fixed/wide range ) in order

F2 A1 Windows 4 / 6 / 8 / 12 / 16 / 18 / 22 / 24 / 32
SW
F3 U/M Window Sizes 30 x 30mm / 30 x 65 mm
F4 A2 Display Device Super bright high efficiency low power consuming LEDs
F5 + Facia Type Individual windows lens Front Replaceable
F6 - RS 485 OUTPUT
F7 E Window Colours RED, Yellow, Amber, Green, White & Blue
F8 C3
RC N/W STAND BY Flash Rate Fast - 60 flashes/min. Slow - 30 flashes/min.
RLY-3
C I3 HOOTER
Response Time 40 msec.
F9 C2
RLY-2 RC N/W Input Signal Potential free contacts (NO or NC site selectable)
F10 I2
F11 C1 Grouping Trip / Non Trip site selectable
RLY-1 RC N/W
F12 I1 Interrogation Voltage + 12 V DC
F13 ~/+VE STAND BY Output Contacts 1 NO + 1 NO + 1 NO (optional)
F14 ~/ - VE SUPPLY
~/+VE AUX. SUPPLY Architecture Integral
F15
~/ - VE NORMAL Operational Sequences Auto/Manual/First-up/Ringback (optional)
F16 AUX. SUPPLY SUPPLY
C E AUX. SUPPLY (site selectable) OR any other sequence on request
F17 Operational Temp. 0-60 degrees C
F18
Note Power Consumption 1.5 Watts per Window (Max)
F19 1) In Case of Normal Supply Failure, RLY-3
F20 is for Stand by Hooter (at AC/DC fail
Optional AC-DC fail Annunciation or Indication / Repeat Relays / RS232 - 485 Port
F21 feature) Dimensions (mm) 1D 2D 3D 4D
F22 2) For supply fail Annunciators/Indication,
Panel Cutout (L x W) 138 x 66 138 x 138 138 x 210 138 x 282
F23 Window no. 01 is dedicated.
Overall (L x W x D) 144 x 72 x 215 144 x 144 x 215 144 x 216 x 215 144 x 288 x 215
F24
C Wherever not specified Contact Rating : 5A @ 230 V AC (resistive) * CE marked products available on request.
F25
F26
F27 Dimensional & Panel Cutout Details
F28
F29 72 72
72
F30 F1 F1 F2
F1 F2
F2 F3 F4
F31 144 F3 F4
F3 F5 F6
F32 F5 F6
F4 F7 F8
C
TEST TPB 1D
MUTE MPB 144 144 144
ACK APB F1 F5 F1 F5 F1 F2 F9 F10
RST RPB F2 F6 F2 F6 F3 F4 F11 F12
144
C 2D
F3 F7 F3 F7 F5 F6 F13 F14
F4 F8 F4 F7 F8

216 216 216


F1 F5 F9 F1 F5 F9 F1 F2 F9 F10 F17 F18
F2 F6 F10 F2 F6 F10 F3 F4 F11 F12 F19 F20
144
F3 F7 F11 F3 F7 F11 F5 F6 F13 F14 F21 F22
3D F4 F8 F12 F4 F8 F7 F8 F15 F16

288 288
F1 F5 F9 F13 F1 F2 F9 F10 F17 F18 F25 F26
F2 F6 F10 F14
144 144 F3 F4 F11 F12 F19 F20 F27 F28
F3 F7 F11 F15 F5 F6 F13 F14 F21 F22 F29 F30
F4 F8 F12 F16 F7 F8 F15 F16 F23 F24 F31 F32