American Power Design, Inc.: Features
American Power Design, Inc.: Features
ELECTRICAL SPECIFICATIONS
GENERAL SPECIFICATIONS
Temp. Stability ................................................... +/-0.02%/°C EMI/RFI ........................ Six Sided Shield (Case is Connected to -IN)
Temp. (Operating , Case) ................................... -25 to +70°C Derating ......................................................................... None
Temp. (Storage) ............................................... -40 to +125°C Cooling ................................................... Free-Air Convection
PHYSICAL SPECIFICATIONS
Encapsulation Material ................................. UL 94V-0 Epoxy
Dimensions .............................................. 1 x 2 x 0.41 inches
Case Material ............................................ Nickel Plated Metal
Weight ......................................................................... 1.2 Oz
(With Non-Conductive Base Plate)
A15-120/B/Y
/Y RoHs Compliance
Product Family
2.03 [51.44]
0.80 [20.32]
0.61 [15.56]
1
1.03 [26.04] 0.80 [20.32]
2
(BOTTOM VIEW)
0.41 [10.48]
0.11 [2.86]
0.20 [5.08]
0.41 [10.41]
PIN # FUNCTION
1 + Input
2 - Input
The A15 Series of power converters have been designed Figure below shows a typical output voltage during turn-on,
to be stable with no external capacitors when used in low measured at no load current with no additional output
inductance input and output circuits. However, in some filtering.
applications, the inductance associated with the distribution
from the power source to the input of the converter can
affect the stability of the converter. The addition of a 100
µF electrolytic capacitor with an ESR <1 Ohm across the
input helps ensure stability of the converter. In many
applications, the user has to use decoupling capacitance at
the load.
The inrush current of the A15 Series has been kept as low The figure below show how to connect outputs of several
as possible. However, a series resistor may be inserted in units with equal nominal output voltage in parallel with the
the input line to limit this current further. use of oring diodes.
UNIT 1 Dx
+ OUTPUT
+ IN
LOAD TRANSIENT - IN
Load
- OUTPUT
Figure below shows a typical output voltage response,
measured during a transition from full rated load current to
no load current with no additional output filtering.
UNIT 2 Dx
+ OUTPUT
+ IN
- IN
- OUTPUT
NOTE:
The ratings of Dx should be 1.5
times the maximum current and
voltage expected in each branch.
CONNECTION IN SERIES
+ IN
Dx
- IN
- OUTPUT
Load
UNIT 2
+ OUTPUT
NOTE:
+ IN
The ratings of Dx should be 1.5
Dx
- IN times the maximum current and
voltage expected in each branch.
- OUTPUT
In order to avoid possible damage, any penetration of The appearance of products, including safety agency
cleaning fluids must be prevented, since the power certifications pictured on labels, may change depending
supplies are not hermetically sealed. on the date manufactured. Specifications are subject to
change without notice.
American Power Design products are not designed, The converters are designed to meet North American and
intended for use in, or authorized for use as critical International safety regulatory requirements per UL 60950-
components in life support systems, equipment used in 1/CSA 22.2 No. 60950-1-07 Second Edition, IEC 60950-1:
hazardous environments, or nuclear control systems 2005, and EN 60950-1:2006. Basic Insulation is provided
without the express written consent of American Power between input and output. To comply with safety agencies
Design, Inc. requirements, an input line fuse must be used external to
the converter. The table below provides the recommended
fuse rating for use with this family of products.
9-36Vdc 3A
20-60Vdc 1.5A
36-72Vdc 1A
WARRANTY
All products manufactured by American Power Design, Inc. (APD) are warranted to be free of defects due to material or
workmanship for a period of one year from date of shipment. At our option, APD will repair or replace any non-conforming
product.
APD expressly disclaims any liability for consequential or incidental damages resulting from the use or misuse of its products
by the purchaser or others.
This warranty is in lieu of all warranties expressed or implied, including the warranties of merchantability. No other warranties,
obligations, or liabilities are expressed or implied.
All products being returned for repair require a return material authorization(RMA) assigned by APD prior to return shipment.