GRAMPIAN LIFTING SERVICES

GRAMPIAN HOUSE, ST FERGUS, PETERHEAD


Tel: 07753 722288 Fax: 01779 838758
E-Mail: [email protected]
PROOF LOAD TEST AND MAGNETIC PARTICLE INSPECTION REPORT
Client Name: Client Order Number:
AQUATIC Certification Number: Date of Examination:
AQIM / 146 27/06/17

ID Number Quantity Description SWL Proof Load


AQPR-08E- 1 PAIR REEL TOWER SECTION TOWERS IN
TA ACCORDANCE WITH DNV 2.22
WELDED STEEL CONSTRUCTION
2.00M x 1.50M x 4.20M

06 BOTTOM MOUNTED HANDLING POINT 8.5TE PER 10.62TE


PADEYES PADEYE PER
PADEYE

02 TOP MOUNTED MAIN LIFT POINT 12TE PER 15TE PER


PADEYES PADEYE PADEYE

MANUFACTURER AND DATE OF MANUFACTURE IF KNOWN 12-07-12


DATE OF NEXT THOROUGH EXAMINATION 26/12/17
EQUIPMENT SAFE TO OPERATE? YES
ADDRESS WHERE EXAMINATION TOOK PLACE AQUATIC
Dales Ind. Estate, Peterhead

MAGNETIC PARTICLE INSPECTION


Standard: BSEN9934-1:2001 Equipment Type: AC YOKE Contrast Media:
NPT16 WHITE PAINT
Test Procedure No: QP9.6 Pole Spacing: 100mm Indicator: BLACK INK

Inspector: Ian McLeman


RESULTS: 100% MAGNETIC PARTICLE INSPECTION WAS CARRIED
OUT ON THE LIFTING POINT WELDS OF THE ABOVE EQUIPMENT. Qualification: SNT Level II
NO CRACKS OR CRACKLIKE INDICATIONS WERE NOTED AT THE
TIME OF INSPECTION.

(a) The Lifting Operations and Lifting Equipment Regulations 1998 SI No 2307
(b) The Supply of Machinery (Safety) Regulations 1992 SI No 3073
(c) The Provision and Use of Work Equipment Regulations 1998 SI No 2306

I hereby certify that the equipment described on this certificate has been visually examined and found to be free of flaws or other
defects.

Signature of Test Engineer:

Grampian Lifting Services – For all your Lifting Requirements


Form – CF-24-Rev: 0 – August 2014