DP6™ PLUS Punchdown Patch Panels

SPECIFICATION SHEET

specifications
TX6 ™ PLUS UTP Copper
Category 6/Class E, punchdown patch panels shall Cabling System
terminate 4-pair, 22 – 26 AWG, 100 ohm unshielded
twisted pair cable with an industry standard single
wire 110 punchdown tool. Patch panels shall include DP6 ™ PLUS Angled Punchdown
a universal label coded for T568A and T568B wiring Patch Panels
schemes and mount to 19" and 23" racks. Patch 24-port, 1 RU: DPA24688TGY
panels shall be easy to identify with pre-printed 48-port, 2 RU: DPA48688TGY
numbers, write-on areas and optional label kits. DP6 ™ PLUS Flat Punchdown
Patch Panels
technical information 12-port:
24-port, 1 RU:
DP12688TGY
DP24688TGY
Category 6/Class E Exceeds channel requirements of ANSI/TIA-568-C.2 Category 6 and 48-port, 2 RU: DP48688TGY
channel and component ISO 11801 Class E standards at swept frequencies 1 to 250 MHz TX6000 ™ UTP Copper Cable
performance:
Plenum: PUP6004*
 Exceeds component requirements of ANSI/TIA-568-C.2 Category 6 Riser: PUR6004*
and ISO 11801 Class E standards at swept frequencies 1 to 250 MHz LSZH: PUL6004*
FCC and ANSI Meets all applicable ANSI/TIA-968-A requirements; contacts plated CM: PUC6004*
compliance: with 50 microinches of gold for superior performance TX6 ™ PLUS UTP Patch Cords
IEC compliance: Meets IEC 60603-7 CM (foot lengths): UTPSP*^Y
PoE compliance: Supports IEEE 802.3af, 802.3at, and IEEE 802.3bt type 3 and 4 for PoE CM (meter lengths): UTPSP^^MY
applications up to 100 W LSZH (meter lengths): UTPSPL^^MY
UL rated: UL 1863 approved TX6™ PLUS 28 AWG UTP Patch Cords
Conductor termination Compatible with 22 – 26 AWG solid or stranded IWC cable with conductor CM/LSZH (foot lengths): UTP28SP^
range: insulation diameters of 0.048 in. CM/LSZH (meter lengths): UTP28SP^^M
Mounting option: Mounts to standard EIA 19" or 23" racks (with optional extender Tools and Accessories
bracket); 12-port version can be wall mounted with optional 89D bracket Wire snipping tool: CWST
Packaging: Includes M6 and #12-24 mounting screws Wire stripping tool: CJAST
Punchdown tool: PDT110
24-port label kit: DPLK24
48-port label kit: DPLK48
key features and benefits Replacement
module: DRJ688TGBL
100% performance tested Confidence that each jack module will deliver the critical Strain relief bar: SRBM19BLY
Extender bracket: PEB1
electrical performance requirements Clear dust cap: MDC-C
Individually serialized Each port is marked with quality control number for future traceability Block out device: PSL-DCJB-^^^
RJ45 interface Industry standard interface provides a quick and easy plug Phone icons: CIPIW-C‡
and play connection to RJ45 patch cords; backwards compatible Data icons: CIDIW-C‡
Identification Can be clearly identified with optional labels and icons for *To designate color, add suffix BU (Blue) or
port identification WH (White). For additional cable colors,
contact customer service.
Universal wiring scheme T568A and T568B wiring schemes clearly identified
^For lengths 1 to 20 feet (one foot increments)
Industry standard Single wire 110 punchdown tool (PDT110) ensures conductors and 25, 30, 35, 40 feet, change the length
termination tool are fully terminated designation in the part number to the desired length.
For standard cable colors other than
Block out device (optional) Provides a simple and secure method to control access to data Off White, add suffix BL (Black), BU (Blue),
ports while not in use RD (Red), YL (Yellow), GR (Green), OR (Orange) or
Angled design (optional) Facilitates proper bend radius control and minimizes the need VL (Violet). For example, the part number for a blue
15-foot patch cord is UTPSP15BUY.
for horizontal cable managers
^^For lengths 1 to 10 meters (one meter
Replacement port module Ability to replace field damaged ports for complete panel utilizations increments) and 2.5, 15, 20, 25, 30, 35, 40 meters,
(optional) change the length designation in the
part number to the desired length. For standard
cable colors other than Off White, add suffix
applications BL (Black), BU (Blue), RD (Red), YL (Yellow), GR
(Green), OR (Orange) or VL (Violet). For example,
DP6™ PLUS Punchdown Patch Panels are a Class E Edition 2.1 standards, these systems the part number for a blue 15-meter patch cord is
UTPSP15MBUY.
component of the TX6™ PLUS UTP Copper will support the following applications:
Cabling System. This end-to-end system is • Ethernet 10BASE-T, 100BASE-T (Fast ^^^To designate color other than Red, add suffix
interoperable and backwards compatible, Ethernet), 1000BASE-T (Gigabit Ethernet) BL (Black), BU (Blue), YL (Yellow), GR (Green), OR
(Orange), IW (Off White) or IG (International
providing design flexibility to protect network • 155 Mb/s ATM, 622 Mb/s ATM, Gray) at the end of the part number. 10/package.
investments well into the future. With certified 1.2 Gb/s ATM
‡To designate color other than IW (Off White),
performance to the ANSI/TIA-568-C.2 Category • Token Ring 4/16 replace IW with EI (Electric Ivory), IG (International
6 and ISO 11801 Class E standards, this system • Digital video and broadband/baseband Gray), BL (Black), BU (Blue),
is ideal for today’s high performance workstation analog video RD (Red), YL (Yellow), GR (Green), OR (Orange)
applications. With certified performance to the • Voice over Internet Protocol (VoIP) or VL (Violet) in the part number. 100/package.
ANSI/TIA-568-C.2 Category 6 and ISO 11801

w w w . pa n d u it.c om
DP6™ PLUS Punchdown Patch Panels
Test Results
Mechanical Test Test Method Measurement Typical Test Results
Normal Force — Load (grams) >100
Vibration IEC 512-6d Circuit Resistance (mOhms) <40
Shock IEC 512-6c Contact Disturbance (microseconds) <5
Durability IEC 512-9a Circuit Resistance (mOhms) <40
Mating/Un-Mating IEC 512-13b Mating Force (N) <20
Un-Mating Force (N) <20
Termination Cycles IEC 352 Number of Cycles >20

Electrical Test Test Method Measurement Typical Test Results


Low Level Circuit Resistance IEC 512-2a Resistance (mOhms) <20
Dielectric Withstand Voltage IEC 512-4a 1000 V, 1 minute Passed
Insulation Resistance IEC 512-3a Resistance (mOhms) >500

Environmental Test Test Method Measurement Typical Test Results


Temperature Life IEC 512-9b Circuit Resistance (mOhms) <40
Humidity IEC 512-11c Circuit Resistance (mOhms) <40
Thermal Shock IEC 512-11d Circuit Resistance (mOhms) <40
Climatic Sequence IEC 512-11a Circuit Resistance (mOhms) <40
Flowing Mixed Gas Corrosion IEC 512-11g Circuit Resistance (mOhms) <40

10.0 (254.0)

1.00
(25.4)
12-Port DP6 ™ PLUS Patch Panel 2.09
(53.2)

17.42 (442.5)
17.42 (442.5)

1.17
1.17 (29.6) 19.0 (482.6)
(29.6) 19.0 (482.6)

1.72 48-Port DP6 ™ PLUS Patch Panel 3.47


24-Port DP6 ™ PLUS Patch Panel
(43.7) (88.1)

4.75
(120.6)
4.75
(120.6)
19.0 (482.6)
19.0 (482.6)

1.72 3.47
24-Port DP6 ™ PLUS Angled Patch Panel (43.7)
48-Port DP6 ™ PLUS Angled Patch Panel
(88.1)
Dimensions are in inches. [Dimensions in brackets are metric].

WORLDWIDE SUBSIDIARIES AND SALES OFFICES


PANDUIT CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD.
Markham, Ontario London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia
[email protected] [email protected] [email protected] [email protected] [email protected] [email protected]
Phone: 800.777.3300 Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020

For a copy of Panduit product warranties, log on to www.panduit.com/warranty

For more information ©2016 Panduit Corp.


ALL RIGHTS RESERVED.
Visit us at www.panduit.com COSP398--WW-ENG
Contact Customer Service by email: [email protected] Replaces WW-COSP45
or by phone: 800.777.3300 9/6/2016

You might also like