TRA & TRA-RF

Flexible cables for reeling applications - Heavy duty operations - 0.6 / 1 kV

All the very stringent characteristics of the insulating cover and the
sheath make the cable suitable for use with reeling systems such as
6 power supply of moving machines. In addition to its excellent mechanical
4 characteristics, the polyurethane sheath has a good resistance to wear
combined with a high flexibility over a large range of temperatures.
5

3
7G and
Design 12G
2
1 Green polyurethane outer sheath RAL 6032 (TRA-RF: black)
2 Textile anti twist braid
20G up
3 Polyurethane inner sheath to 28G
1 4 Plain copper cores 2.5 mm²
5 Polypropylene insulation:
• Phase cores: black with printed marking 42G and
54G
• Earth core: green / yellow
6 Reinforced kevlar filler

Marking
« CONDUCTIX WAMPFLER / TRA __G2.5 - 0.6/1kV »

Standards Conditions of use Voltage


• NF-EN 60228 (class 5) and/or • Suitable for all spool types in • 0.6 / 1 kV - Low Voltage
CEI 60228 for the copper cores adequacy with the minimum
• VDE 295 - BSI 6360 for bending radius. Linear reeling speed
the copper cores • Installation with deflection pulley: • 200 m/min max.
• Flame resistance: class C3 use TRA-RF reinforced cable.
(not tested) Ambient temperature
• Halogen free • From -25 up to +60°C (see table
for de-rating factors on next page).
Cables TRA & TRA-RF (a) Technical Data
Type TRA TRA-RF
No of Cores and Nominal C.S.A. (mm²) 7G2.5 12G2.5 20G2.5 24G2.5 28G2.5 42G2.5 54G2.5 42×2.5
Mechanical Data
Min. outer diameter (mm) 13.3 20.5 21.0 24.3 25.7 30.0 33.2 31.0
Max. outer diameter (mm) 14.7 22.6 23.1 26.8 28.4 33.1 36.7 34.1
Unsheathed cable diameter (mm) 9.5 15.0 15.5 18.0 19.5 23.0 26.5 23.0
Linear weight (kg/m) 0.30 0.63 0.80 1.00 1.10 1.60 2.00 1.60
Min. bending radius (mm):
Anchor drum Max. outer diameter × 4
Spool Max. outer diameter × 6
Guiding device Max. outer diameter × 9
Pulley Not recommended - Contact us Max OD× 12
Max. tensile load (daN):
Direct 52 90 150 180 210 315 405 315
With guiding device 35 60 100 120 140 210 270 210
With pulley Not recommended - Contact us 210
Electrical Data
Current carrying capacity (A) (b) 20 16 13 12 11 10 9 10
Voltage drop (V/A.km) (c)
14 14 14 14 14 14 14 14
Resistance Max. DC resistance of a core @ +20°C = 7.98 Ω/km

(a): Cable TRA-RF especially designed for use with deflection pulley, (b): Cable laid on the ground @+30°C
without green / yellow earth conductor, black outer sheath. (c): cos = 0.8 / temperature of cores = +90°C

Recommendations Installation
• Amperage de-rating factor for • Minimum distance between two guiding devices: L min = 20 × cable O.D.
reeling applications: 0.85
in
• De-rating factors in relation to the Lm
ambient temperature above 30°C:
30°C up to 40°C 0.90
40°C up to 50°C 0.80
L min

50°C up to 55°C 0.74


55°C up to 60°C 0.65

• Recommended voltage drop limits: • Deflection angle (if Ør < bending radius) = 15° max for laying on rollers
Usual 5%
Lighting 3% Ør
15°

Frequency inverter 2.5%


15°

E-TRA-0609