AHDA Radio Description
AHDA Radio Description
Functional description
Interfaces
Electrical specifications
g Note: The minimum start-up voltage is –40.5 V DC. If the input voltage is below/beyond
the extended limits, the unit might shut down.
Power consumption
Typical power consumption [W] for 48VDC input, at 25°C, representative of typical
product performance under the same conditions (HW variant, SW version, configuration,
environment, and so on) with +/- 10% margin. Average = (6h low hour load, 10h medium
hour load and 8h busy hour load) /24h
Configurations explained on examples:
• GSM/WCDMA: 2/2/2 = three sectors, two carriers/TRXs per sector
• LTE:
o 2/2/2 2Tx = three sectors, two carriers per sector, 2Tx per carrier
o 1+1/1+1/1+1 4Tx = three dual-band sectors, one carrier per sector per band, 4Tx
per carrier
Some radio units are capable of providing only one sector coverage. Then the power
values in the table consider deployment of three radio units.
Power reduction
g Note: The maximum power reduction (dlCellPwrRed) value is 20 dB. High power
reduction values may cause radio outages.
g Note: Do not configure the GSM cell power below 30 dB total dynamic range from the
max. rated power. It might make the system unstable.
Installation options
w NOTICE: Install this RRH in a vertical orientation with connectors on the bottom side, to
ensure convection cooling. For horizontal installation fans are required.
Volume 13.6 l
Weight 14.0 kg (30.9 lbs)
Environmental specifications
The LTE3678: AirScale RRH 2T4R B8 120W AHDA feature is impacted by the following
features:
• LTE114: Cell Bandwidth - 10 MHz enables the use of LTE 10 MHz carriers.
• LTE115: Cell Bandwidth - 5 MHz enables the use of LTE 5 MHz carriers.
• LTE116: Cell Bandwidth - 3 MHz enables the use of LTE 3 MHz carriers.
• LTE117: Cell Bandwidth - 1.4 MHz enables the use of LTE 1.4 MHz carriers.
• With LTE614: Distributed Site, AHDA can be used in distributed sites with up to 23
km fiber length to the system module.
• LTE1103: Load based Power Saving for multi-layer networksenables the use of Load
based Power Saving for multi-layer networks.
• LTE1203: Load based Power Saving with Tx path switching off enables the use of
Load based Power Saving with Tx path switching off.
• LTE2508: BTS Embedded Power Meter for Energy Efficiency Monitoring enables the
use of BTS Embedded Power Meter for Energy Efficiency Monitoring.
• LTE2541: Nokia CPRI RRH/RFM chaining provides support for chaining.
• LTE3036: Micro DTX extension enables the use of Micro DTX extension.
Functional description