24 VOLT DUAL MODE

AUTOMATIC BATTERY CHARGER


MODEL 18330 TYPE 24EL8

Specifications
AC Supply: 120 volts, 60 Hertz, single-phase, 3 amps maximum
DC Output: 24 volts, 8 amps tapering to 2 amps
Battery Capacity: Two series connected, 6 cell, 12 volt deep-cycle motive power batteries. Gel
cell and sealed "maintenance-free" or conventional replaceable electrolyte
deep-cycle batteries
Battery Size: 28 to 90 amp hours
Normal Recharge Time: 8 hours

PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS


For correct operation of the equipment, it is important to read and be familiar
with this entire manual before installing and operating the charger.
DO NOT DISCARD THIS MANUAL AFTER READING.

LOOK FOR THIS SYMBOL TO POINT OUT SAFETY PRECAUTIONS. IT MEANS:


BECOME ALERT—YOUR SAFETY IS INVOLVED. IF YOU DO NOT FOLLOW THESE
SAFETY INSTRUCTIONS, INJURY OR PROPERTY DAMAGE CAN OCCUR.

Features
 Charger output characteristics are adjustable to charge gel cell and sealed or conventional replaceable liquid electrolyte
deep-cycle lead-acid batteries. Different charge characteristics are selected by a switch on the front of the charger.
 Patented electronic circuit monitors battery state of charge and automatically turns charger off as battery reaches full charge
 Line voltage compensation produces consistent charger output for AC supply voltage variations of + 3% from nominal.
 Convection-cooled design for maximum reliability and minimum maintenance.

INTRODUCTION "BATTERY TYPE" switch to the correct setting. A


The Dual-Mode wheelchair battery charger is patented electronic circuit turns the charger on and
designed to recharge deep-cycle, lead-acid batteries off automatically.
of conventional replaceable electrolyte or gel cell Batteries used on wheelchairs are subjected to
and sealed "maintenance-free" design. The different severe deep-cycle duty on a daily basis. For this
charge characteristics required by these different reason, it is important that only Deep-Cycle batteries
types of battery design are selected by sliding the be used.

lesterelectrical.com 1 01577P
AC INPUT
CAUTION: THIS CHARGER IS FOR USE
ONLY ON 12 CELL, 28-90 AMP-HR (20 HR. This battery charger must be grounded to reduce the
RATE), 2.38-2.50 VOLTS PER CELL MAXIMUM risk of electric shock. It is equipped with an electric
VOLTAGE RECHARGEABLE, DEEP-CYCLE cord having an equipment-grounding conductor and
BATTERY SYSTEMS. THIS CHARGER IS FOR a ground-type plug. The plug must be plugged into
USE ON REPLACEABLE ELECTROLYTE OR GEL an appropriate outlet that is properly installed and
CELL AND SEALED "MAINTENANCE-FREE" grounded in accordance with the National Electrical
DEEP-CYCLE BATTERIES. "BATTERY TYPE" Code and all local codes and ordinances.
SWITCH MUST BE SET TO THE PROPER TYPE
OF BATTERY. BATTERIES IMPROPERLY DANGER: IMPROPER CONNECTION OF THE
MATCHED WITH CHARGER MAY BURST, EQUIPMENT-GROUNDING CONDUCTOR CAN
CAUSING PERSONAL INJURY AND DAMAGE TO RESULT IN RISK OF ELECTRIC SHOCK. DO
BATTERIES OR CHARGER. NOT REMOVE GROUNDING PRONG FROM
PLUG.

INITIAL INSTALLATION
GROUNDING INSTRUCTIONS
Circuit breaker or fuse protection in the 120 volt AC
outlet to which the charger is to be plugged should This battery charger is equipped with a grounding
allow 5 amps per charger. Do not overload electrical plug as illustrated in Figure A, for use on a nominal
outlet. Use of an extension cord with the charger 120 volt, 60 Hertz circuit. A temporary adapter, as
should be avoided unless absolutely necessary. illustrated in Figures B and C, may be used to
Use of an improper extension cord could result in a connect this plug to a two-pole receptacle as shown
risk of a fire and electric shock. If an extension cord in Figure B if a properly grounded outlet is not
is needed, use a three-conductor, No. 16 AWG (or available. The temporary adapter should be used
larger) cord with ground, properly wired, in good only until a properly grounded outlet can be installed
electrical condition and keep as short as possible. by a qualified electrician. The green-colored rigid
Make sure that the pins on the plug of the extension ear extending from the adapter must be connected
cord are the same number, size, and shape as that to a permanent ground such as a properly grounded
of the plug on the battery charger. Locate all cords outlet box.
so that they will not be stepped on, tripped over, or
otherwise subjected to damage or stress. Do not DANGER: BEFORE USING THE ADAPTER
operate the battery charger with a damaged cord or AS ILLUSTRATED, BE CERTAIN THAT THE
plug. Do not operate the battery charger if it CENTER SCREW OF THE OUTLET PLATE IS
received a sharp blow, was dropped, or otherwise GROUNDED.
damaged in any matter. Refer to a qualified service GROUNDING METHODS
agent.
Provide adequate ventilation for both batteries and
charger. The convection cooled design requires an
unobstructed flow of cooling air for proper operation.
Keep all charger ventilation openings at least two
inches (2") (5.08cm) away from walls and other
objects. Do not allow clothing, blankets, or other
material to cover charger. DO NOT PLACE UNDER
BED.

WARNING: CHARGERS CAN IGNITE NOTE: Use of adapter shown in Figures B and C is
FLAMMABLE MATERIALS AND VAPORS. DO NOT permitted in Canada.
NOT USE NEAR FUELS, GRAIN DUST,
SOLVENTS, THINNERS, OR OTHER
BATTERY TYPE
FLAMMABLES.
Battery manufacturers frequently use the same
WARNING: KEEP DRY; DO NOT EXPOSE TO battery cases for different battery types.
RAIN OR SPRAY. FOR STORAGE, KEEP Replaceable liquid electrolyte deep-cycle batteries
CHARGER IN A BUILDING. REPLACE WORN, have removable cell caps. Water electrolyzed by
CUT, OR DAMAGED ELECTRICAL CORDS AND discharging and charging the battery is replaced
PLUGS IMMEDIATELY. through these openings.

lesterelectrical.com 2 01577P
Gel cell and sealed "maintenance-free" deep-cycle GOOD WORKING CONDITION. DO NOT USE
batteries are generally distinguished by non- CONNECTORS THAT ARE CRACKED,
removable cell caps. The physical appearance of CORRODED, OR DO NOT MAKE ADEQUATE
the battery case is frequently the same as that of a ELECTRICAL CONTACT. USE OF A DAMAGED
replacement liquid electrolyte battery though the cell OR DEFECTIVE CONNECTOR MAY RESULT IN A
caps are generally not removable. RISK OF OVERHEATING OR ELECTRIC SHOCK.
Refer to the battery manufacturer's information panel 2. Move "POWER" switch to "OFF" position.
on the battery case to determine the type battery 3. Connect the power supply cord to a properly
you have. If the information panel is missing or not grounded, 120 volt, 60 Hertz single-phase outlet.
legible, do not use the battery. Refer to your dealer
if you do not understand what type battery you are 4. Connect charger's DC output plug to the
using and have them set the "BATTERY TYPE" wheelchair charging receptacle. Do not connect
switch accordingly. the DC plug unless the "POWER" switch is in
the "OFF" position.
The "BATTERY TYPE" switch is a two-position slide
switch visible in the rectangular opening on the front 5. Move the "POWER" switch to "ON" and the RED
of the charger. Using a small screwdriver, slide the and GREEN lights will come on steady for a few
switch from one setting to the other through the seconds to test the light. If the lights do not
opening. Take care not to damage the switch when come on, either the AC cord is not plugged in or
moving it to the desired setting. the AC outlet is not live. Test for a live AC outlet
by connecting a suitable household appliance
into the specific outlet.
NORMAL OPERATION
Instructions printed on cover of charger are for WARNING: CHARGER IS NOT TO BE USED
daily reference. WHILE THE EQUIPMENT IS OPERATING.
1. Set "BATTERY TYPE" switch to the proper style
ATTENTION! Ne pas utiliser le charger
of battery to be charged.
pendant que l'equipment est en marche.
CAUTION: MAKE SURE THE BATTERY
WARNING: LEAD-ACID BATTERIES
PACK IS A 24-VOLT, 12-CELL, SERIES
GENERATE GASES WHICH CAN BE EXPLOSIVE.
CONNECTED, 28-90 AMP-HOUR (20 HR. RATE),
TO PREVENT ARCING OR BURNING NEAR
RECHARGEABLE DEEP-CYCLE BATTERY
BATTERIES, DO NOT DISCONNECT DC
SYSTEM. THE "GEL CELL AND SEALED DEEP-
CHARGING CORD FROM BATTERIES WHEN
CYCLE BATTERY" SETTING CHARGES TO A
THE CHARGER IS OPERATING. IF THE CHARGE
MAXIMUM ON-CHARGE VOLTAGE OF 2.38
CYCLE MUST BE INTERRUPTED, MOVE THE
VOLTS PER CELL. THE "REPLACEABLE
"POWER" SWITCH TO "OFF", AND
ELECTROLYTE DEEP-CYCLE BATTERY"
DISCONNECT THE CHARGER POWER SUPPLY
SETTING HAS AN ON-CHARGE VOLTAGE OF AT
CORD BEFORE DISCONNECTING THE DC
LEAST 2.50 VOLTS PER CELL. VISUALLY
OUTPUT CORD FROM THE BATTERIES. KEEP
CHECK THAT THE BATTERY TYPE SWITCH IS
SPARKS, FLAME, AND SMOKING MATERIALS
SET CORRECTLY FOR THE TYPE OF BATTERY
AWAY FROM BATTERIES.
YOU ARE USING.
WARNING: ALWAYS SHIELD EYES WHEN
CAUTION: MANY DC PLUGS DO NOT HAVE
WORKING NEAR BATTERIES. DO NOT PUT
A STANDARDIZED WIRING PATTERN. BEFORE
WRENCHES OR OTHER METAL OBJECTS
CONNECTING TO EQUIPMENT, VERIFY THAT
ACROSS BATTERY TERMINAL OR BATTERY
THE CHARGER PLUG WIRING PATTERN
TOP. ARCING OR EXPLOSION OF THE
MATCHES THE EQUIPMENT BEING CHARGED
BATTERY CAN RESULT!
BEFORE CONNECTING. DAMAGE MAY RESULT
IF A PLUG THAT IS WIRED FOR OTHER Charger will output power three to five (3-5)
APPLICATIONS IS USED ON YOUR EQUIPMENT. seconds after turning switch "ON" as indicated
CONTACT YOUR DEALER OR THE EQUIPMENT by the RED light turning off, the slow blinking
MANUFACTURER FOR MORE INFORMATION. GREEN light (once per second), and a slight
transformer hum.
DANGER: TO PREVENT ELECTRIC SHOCK, If both lights go off about five (5) seconds after
DO NOT TOUCH UNINSULATED PARTS OF THE AC is applied, check to see if the DC plug is
CHARGER DC OUTPUT CONNECTOR, BATTERY correctly connected to the battery. If the DC
CONNECTOR, OR BATTERY TERMINALS. MAKE plug is connected properly, either an open circuit
SURE ALL ELECTRICAL CONNECTORS ARE IN exists in the wheelchair's internal circuitry or the
lesterelectrical.com 3 01577P
battery voltage is below 7 volts (see normal charging. Larger batteries (greater than
Troubleshooting). 90 ampere-hours) or severely discharged
The charger has an under-voltage protection batteries may require up to 16 hours to be
mode which will terminate the charge if the properly charged and equalized. If the charger
battery voltage does not increase above 18 volts operates for 16 hours and is unable to fully
in 10 minutes. This prevents destroying 12-volt charge the batteries, an internal timer turns the
battery systems with this 24-volt charger. When charger off and begins to fast blink the RED
this shutoff occurs, the RED light will come on light.
steady. A maximum voltage shutoff for wet batteries is
6. Correct initial charge rate should be between 7 an additional safety feature of the charger.
to 9 amps. As the batteries become more When the battery potential increases above 2.83
charged, the charge rate decreases. When the volts per cell, the charge cycle is terminated and
batteries reach approximately 80% of full the RED light begins to slow blink.
charge, the GREEN light will fast blink (eight 9. After the charger has turned off, move the
times per second), the charge rate will have "POWER" switch to "OFF", then disconnect the
decreased as determined by the "BATTERY DC output cord from the wheelchair charging
TYPE" switch setting and the condition of the receptacle.
batteries.
Replaceable Electrolyte Deep Cycle Batteries CAUTION: TO AVOID DAMAGE TO THE
CHARGER CORD AND BATTERY CONNECTOR,
With healthy batteries, the charging current will DISCONNECT BY GRASPING THE PLUG
decrease to between 1 to 3 amps and remain HANDLE OR BODY AND PULLING IT STRAIGHT
there until the charger turns off. As replaceable OUT OF THE BATTERY CONNECTOR. DO NOT
electrolyte deep cycle batteries lose capacity, PULL ON THE CHARGER CORD. DO NOT
the charge rate may no longer decrease to this TWIST, ROCK, OR PULL THE PLUG SIDEWAYS.
reading. The charger will still determine when
the batteries are as charged as they are capable
WARNING: TO PREVENT ARCING OR
of being and will turn off. When battery capacity
BURNING NEAR THE BATTERIES, DO NOT
has decreased to where the charger is no longer
DISCONNECT THE OUTPUT CORD FROM THE
able to taper down to less than 3 amps, or the
BATTERIES WHILE THE CHARGER IS
batteries will no longer perform as desired, they
OPERATING. IF THE CHARGE CYCLE MUST BE
should be replaced.
INTERRUPTED, FIRST SLIDE THE "POWER"
Gel Cell and Sealed Deep Cycle Batteries SWITCH TO "OFF", THEN DISCONNECT THE
The charging current will decrease to near zero OUTPUT CORD FROM THE BATTERIES. KEEP
and remain there until the charger turns off. Gel SPARKS, FLAME, AND SMOKING MATERIALS
cell deep cycle batteries will still taper to near AWAY FROM BATTERIES. NO SMOKING.
zero charge current even as they wear out and
lose capacity and range. As sealed deep cycle WARNING: DO NOT LEAVE THE DC
batteries lose capacity and range, the charge OUTPUT CONNECTOR PLUGGED IN WHILE
current may no longer decrease to this low a UNATTENDED FOR MORE THAN TWO (2) DAYS.
reading. The charger will still determine when SEVERE OVERCHARGING AND DAMAGE TO
the batteries are as charged as they are capable THE BATTERIES MAY RESULT IF THE
of being and turn off. When the batteries will no CHARGER DOES NOT TURN OFF.
longer perform as desired, they should be
replaced.
PROPER CARE OF DEEP-CYCLE MOTIVE
7. Charger is equipped with a thermal breaker POWER BATTERIES
which automatically turns the charger off if it
overheats. Should charger turn off before the Batteries used on wheelchairs are subjected to
batteries are fully charged, check to be sure all severe deep-cycle duty on a daily basis. For this
ventilation openings are free from obstructions. reason, it is important that only deep-cycle batteries
After charger cools down to a safe temperature, be used. Although these batteries are designed to
it will automatically restart. If charger repeatedly withstand such duty, the following precautions must
overheats, refer to a qualified service agent. be observed to obtain good performance and
maximum cycle life.
8. Charger turns off automatically when batteries
are fully charged as indicated by steady ON CAUTION: ALWAYS WEAR PROTECTIVE
GREEN light. Charge time varies with battery EYE SHIELDS AND CLOTHING WHEN WORKING
size and depth of discharge. Allow 8 hours for WITH BATTERIES. BATTERIES CONTAIN ACID

lesterelectrical.com 4 01577P
WHICH CAN CAUSE BODILY HARM. DO NOT 3. Wear complete eye protection and clothing
PLACE WRENCHES OR OTHER METAL protection. Avoid touching eyes while working
OBJECTS ACROSS THE BATTERY TERMINALS near battery.
OR BATTERY TOP. ARCING OR EXPLOSION OF 4. If battery acid contacts skin or clothing, wash
THE BATTERY MAY RESULT. SOMEONE immediately with soap and water. If acid enters
SHOULD BE WITHIN THE RANGE OF YOUR eye, immediately flood eye with running cold
VOICE OR CLOSE ENOUGH TO COME TO YOUR water for at least 10 minutes and get medical
AID WHEN YOU WORK NEAR A LEAD-ACID attention immediately.
BATTERY. HAVE PLENTY OF FRESH WATER
AND SOAP NEARBY IN CASE BATTERY ACID 5. NEVER smoke or allow a spark or flame in
CONTACTS SKIN, CLOTHING OR EYES. vicinity of battery.
6. Be extra cautious to reduce risk of dropping a
WARNING: RISK OF EXPLOSIVE GASES. metal tool onto battery. It might spark or short-
WORKING IN VICINITY OF A LEAD-ACID circuit battery or other electrical part that may
BATTERY IS DANGEROUS. BATTERIES cause explosion.
GENERATE EXPLOSIVE GASES DURING 7. Remove personal metal items such as rings,
NORMAL BATTERY OPERATION. FOR THIS bracelets, necklaces, and watches when
REASON, IT IS OF UTMOST IMPORTANCE THAT working with a lead-acid battery. A lead-acid
EACH TIME BEFORE USING YOUR CHARGER, battery can produce a short-circuit current high
YOU READ THIS MANUAL AND FOLLOW THE enough to weld a ring or the like to metal,
INSTRUCTIONS EXACTLY. causing a severe burn.
1. New batteries should be given a full charge 8. NEVER charge a frozen battery.
before their first use because it is difficult to
know how long batteries have been stored.
2. Limit use of new batteries for first 5 cycles. New TROUBLESHOOTING GUIDE
batteries are not capable of their rated output To be able to troubleshoot safely and effectively,
until they have been discharged a number of it is important to read this guide completely
times. before beginning any tests.
3. Do not excessively discharge batteries.
Excessive discharge can cause polarity reversal CAUTION: DO NOT DISASSEMBLE THE
of individual cells resulting in complete failure CHARGER. TAKE IT TO A QUALIFIED SERVICE
shortly thereafter. Limited use of new batteries AGENT WHEN SERVICE OR REPAIR IS
will minimize the change of cell reversal. REQUIRED. INCORRECT REASSEMBLY MAY
RESULT IN RISK OF ELECTRIC SHOCK OR FIRE.
4. CHECK THE LEVEL OF THE ELECTROLYTE
IN CONVENTIONAL LIQUID ELECTROLYTE The following procedures are intended only to
LEAD ACID BATTERIES MONTHLY. determine if a malfunction may exist in the charger.
MAINTAIN THE PROPER ELECTROLYTE
LEVEL BY ADDING WATER WHEN DANGER: TO REDUCE THE RISK OF
NECESSARY. Electrolyte levels lower during ELECTRIC SHOCK, ALWAYS DISCONNECT
discharge and rise during charge. Therefore, it BOTH THE POWER SUPPLY CORD AND THE
is mandatory that water be added to cells ONLY OUTPUT CORD BEFORE ATTEMPTING ANY
when they are fully charged; do not overfill. Old MAINTENANCE OR CLEANING; TURNING THE
batteries require more frequent additions of CHARGER OFF DOES NOT REDUCE THE RISK.
water compared to new batteries.
5. Keep tops of batteries clean and dry to prevent WARNING: DO NOT OPERATE THE
CHARGER IF IT IS MALFUNCTIONING.
excessive self-discharge. Keep battery terminals
PERSONAL INJURY OR PROPERTY DAMAGE
reasonably tight.
COULD RESULT.
Use the following chart to help you troubleshoot
PERSONAL PRECAUTIONS problems with the battery and charger system.
1. Someone should be within range of your voice There are four different modes that each light can
or close enough to come to your aid when you have: OFF (light is off), SLOW BLINK (light blinks
work near a lead-acid battery. on and off once per second), FAST BLINK (light
blinks on and off eight times per second), and
2. Have plenty of fresh water and soap nearby in
STEADY (light is full on).
case battery acid contacts skin, clothing, or
eyes.

lesterelectrical.com 5 01577P
RED LIGHT GREEN LIGHT FUNCTION a. Using the wheelchair before batteries are
OFF OFF No AC power or no battery connected fully charged and charger is turned off
STEADY STEADY Light test when AC connected shortens battery life and begins reducing
OFF SLOW BLINK Charging (less than 80% charged) daily range. This battery capacity loss is
OFF FAST BLINK Charging (over 80% charged)
permanent and not recovered with additional
OFF STEADY Normal charge completed
charge cycles.
STEADY OFF Undervoltage shutoff, < 18.0 volts b. Conventional replaceable liquid electrolyte
SLOW BLINK OFF Overvoltage shutoff, > 33.96 volts batteries are being under charged on the gel
FAST BLINK OFF Maximum timer shutoff, > 16 hours
cell "BATTERY TYPE" switch setting.
Battery capacity lost in this manner is
permanent and is not recovered with
1. If the GREEN and RED lights do not illuminate
additional charge cycles.
within three (3) seconds after the AC power is
applied to the charger, it indicates one of the c. Severe overcharging occurs when gel cell
following: (maintenance-free) batteries are charged on
the conventional wet led acid "BATTERY
a. Charger "POWER" switch is not in "ON"
TYPE" switch setting. Battery capacity lost
position.
in this manner is permanent and occurs very
b. Charger is not plugged into a live AC outlet. rapidly. Check with your dealer about
2. If both lights go off and stay off three to five (3-5) battery replacement.
seconds after the charger connections are d. The battery has been allowed to sulfate.
completed, it indicates one of the following and Charge the battery no less frequently than
the charger is prevented from turning on: once every three (3) days when the
a. DC plug not connected to the wheelchair wheelchair is lightly utilized. Once sulfation
receptacle. is allowed to take place, it may be partially
reduced by returning, temporarily, to daily
b. Fault in wheelchair wiring. Poor or open
charging.
connections in the wheelchair wiring that
connects to the batteries; corroded e. The electrolyte level in conventional liquid
terminals, loose or worn plugs and electrolyte lead-acid batteries was allowed
receptacles, loose or worn fuseholders. to drop below the top of the battery plates.
(Have your dealer repair the wheelchair.) Add distilled water to just cover the tops of
the plates immediately upon discovery and
c. Battery connections in wheelchair wrong
fill to the proper level with distilled water at
(reverse polarity). the completion of the very next charge cycle.
d. One or both batteries no longer serviceable Battery capacity lost in this manner is
(voltage below 7 volts for a 24-volt system). permanent and is not recovered with
3. If the charger turns off before the batteries are additional charge cycles.
fully charged, it indicates one of the following: f. This is the normal wearout process for all
a. Charger internal thermal breaker turned the types of deep-cycle motive power batteries.
charger off due to overheating because 5. If battery voltage does not exceed 18 volts after
charger ventilation openings are blocked. 10 minutes of charging, the charger turns off and
After the charger has cooled down to a safe the RED light will turn on steady indicating one
temperature, it will automatically restart. If of the following:
the charger repeatedly overheats, it may be
a. Improper batteries used with charger. Must
malfunctioning. be a 12-cell, series connected 2.38-2.50
b. The AC power was interrupted during volts per cell battery system.
charge. b. Failed cells in the battery do not allow the
c. The DC cord charging plug accidentally battery voltage to rise above 18 volts.
disconnected during charge. 6. The charger operates through 16 hours before
d. Fault in wheelchair wiring. The wheelchair turning off. The RED light will begin to blink very
charging circuit has high resistance, rapidly indicating one of the following:
corroded or loose connections; loose or
a. Batteries of higher than 90 amp-hour
worn wheelchair charging receptacle, loose
capacity (20 hr. rate) can require more than
or worn wheelchair fuseholders.
16 hours to charge.
4. A decrease in wheelchair range where the chair
b. New batteries (5 cycles or less) can require
loses power earlier and earlier in the day
more than 16 hours to charge.
indicates one of the following:
lesterelectrical.com 6 01577P
c. Very deeply discharged batteries (100% a. Improper batteries used with charger. Must
discharged) can require more than 16 hours be a 12-cell, 2.38-2.50 volts per cell battery
to charge. system.
d. Several failed cells in the batteries that do b. Battery design may be inappropriate for this
not allow the charge rate to taper below 4 use. Check with your dealer for deep-cycle
amps. batteries only.
7. If battery voltage exceeds 2.83 volts per cell, the c. Sulfation of batteries may have occurred.
charger turns off and the right light begins to
slow blink indicating one of the following:

lesterelectrical.com 7 01577P
WIRING DIAGRAM

PARTS LIST FOR 24 VOLT DUAL MODE CHARGER


MODEL 18330 TYPE 24EL8
120 VAC / 60 HZ

PART NO. QTY. DESCRIPTION

31153S 1 CASE ASSEMBLY


22458S 1 SWITCH, ROCKER
04275S 1 BUSHING, STRAIN RELIEF, FOR AC CORD
18363S 1 BUSHING, STRAIN RELIEF, FOR DC CORD
23083S 1 CORDSET, AC, 18/3, 102" W/ MOLDED PLUG
23049S 1 CORDSET, DC, 16/2, 108", W/ CANNON PLUG
16612S 1 CORDSET, DC, 16/2, 108", W/ CANNON PLUG
17219S 1 CORDSET, DC, 16/2, 108", W/ SB50 GRAY PLUG
20838S 1 CORDSET, DC, 16/2, 108", W/ SB50 RED PLUG
14422S 1 CORDSET, DC, 16/2, 108", W/ 30A POWER POLE PLUG
23171S 1 CORDSET, DC, 16/2, 108", W/ 30A POWER POLE PLUG
33099S 1 CORDSET, DC, 16/2, 108", W/ NEUTRIK PLUG

WARNING: DO NOT DISASSEMBLE THE CHARGER. TAKE IT TO A QUALIFIED SERVICE AGENT


WHEN SERVICE OR REPAIR IS REQUIRED.

lesterelectrical.com 8 01577P