SA 07.2 – SA 14.
6
AUMA NORM
Technical data Multi-turn actuators for open-close duty with 1-phase AC motors
Type Output speed Torque range1) Number of Valve attachment3) Handwheel Weight4)
rpm starts2)
Option Max. Ø
Min. Max. Max. Standard EN ISO rising stem Ø Reduct. approx.
60 Hz 50 Hz ft-lb [Nm] ft-lb [Nm] [1/h] MSS SP-102 5210 in [mm] in [mm] ratio lbs [kg]
4.8 4 11 : 1
6.7 5.6 8:1
9.6 8 11 : 1
55 [25]
13 11 8:1
60
19 16 11 : 1
26 22 22 [30] F07 1.02 [26] 8:1
SA 07.2 38 32
7 [10] FA10 6.3 [160]
11 : 1
F10 1.33 [34]
54 45 8:1
75 63 11 : 1
62 [28]
108 90 8:1
30
150 125 5.5 : 1
216 180 18 [25] 4:1
4.8 4 11 : 1
6.7 5.6 8:1
9.6 8 11 : 1
55 [25]
13 11 8:1
60
19 16 11 : 1
26 22 45 [60] F07 1.02 [26] 8:1
SA 07.6 15 [20] FA10 6.3 [160]
38 32 F10 1.33 [34] 11 : 1
62 [28]
54 45 8:1
75 63 11 : 1
108 90 8:1
30 82 [37]
150 125 5.5 : 1
216 180 37 [50] 4:1
4.8 4 11 : 1
62 [28]
6.7 5.6 8:1
9.6 8 11 : 1
60
13 11 8:1
68 [31]
19 16 11 : 1
26 22 88 [120] 8:1
SA 10.2 30 [40] FA10 F10 1.57 [40] 7.9 [200]
38 32 11 : 1
88 [40]
54 45 8:1
75 63 11 : 1
30
108 90 8:1
95 [43]
150 125 5.5 : 1
216 180 74 [100] 4 :1
4.8 4 11 : 1
6.7 5.6 8:1
60 130 [59]
9.6 8 11 : 1
13 11 12.4 8:1
SA 14.2 74 [100] 185 [250] FA14 F14 2.25 [57]
19 16 [315] 11 : 1
134 [61]
26 22 8:1
30
38 32 11 : 1
139 [63]
54 45 8:1
4.8 4 11 : 1
270 [500] 60
6.7 5.6 8:1
139 [63]
9.6 8 15.7 11 : 1
SA 14.6 150 [200] FA14 F14 2.25 [57]
13 11 [400] 8:1
300 [400] 30
19 16 11 : 1
General information 145 [66]
26 22 8:1
AUMA NORM multi-turn actuators require electric controls.
For sizes SA 07.2 – SA 14.6, AUMA offer AM or AC actuator controls. These can also easily be mounted to the actuator at a later date.
Notes on table
1) Torque range The tripping torque is adjustable for directions OPEN and CLOSE within the indicated torque range.
2) Number of starts For actuators equipped 1-phase AC motors with integral permanent split capacitors (motor type VE/AE), an off-time
(reversing prevention time) of 2.5 sec. is required prior to starting in opposite direction.
3) Valve attachment Indicated flange sizes apply for output drive types A and B1.
Refer to dimension sheets for further output drive types.
4) Weight Indicated weight includes AUMA NORM multi-turn actuator with 1-phase AC motor, electrical connection in standard
version, output drive type B1 and handwheel.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Y005.281/065/us Issue 1.16 Page 1/4
SA 07.2 – SA 14.6
AUMA NORM
Technical data Multi-turn actuators for open-close duty with 1-phase AC motors
Features and functions
Type of duty Short-time duty S2 - 15 min, classes A and B according to EN 15714-2
For nominal voltage and 104 °F (+40 °C) ambient temperature and at load with 35 % of the max. torque.
Motors 1-phase AC motor with integral permanent split capacitor (PSC), type IM B9 according to IEC 60034-7, IC410 cooling
procedure according to IEC 60034-6
1-phase AC motor with integral starting capacitor and solid state switch (CSIR), type IM B9 according to IEC 60034-7,
IC410 cooling procedure according to IEC 60034-6
Motor type depending on actuator type/output speed. Refer also to Electrical data SA 07.2 – SA 16.2 with 1-phase
AC motors.
Mains voltage, mains frequency Standard voltages:
1-phase AC current
Voltages/frequencies
Volt 110 – 120 220 – 240
Hz 60 50
Special voltages:
1-phase AC current
Voltages/frequencies
Volt 220 – 240 110 – 120
Hz 60 50
Further voltages on request
Permissible variation of mains voltage: ±10 %
Permissible variation of mains frequency: ±5 %
Overvoltage category Category III according to IEC 60364-4-443
Insulation class F, tropicalized
Motor protection Thermal switches (NC)
Self-locking Self-locking: Output speeds up to 90 rpm (50 Hz) or 108 rpm (60 Hz)
NOT self-locking: Output speeds from 125 rpm (50 Hz) or 150 rpm (60 Hz)
Multi-turn actuators are self-locking if the valve position cannot be changed from standstill while torque acts upon
the output drive.
Motor heater (option) Voltages: 110 – 120 V AC, 220 – 240 V AC
Power depending on the size 12.5 W
Manual operation Manual drive for setting and emergency operation, handwheel does not rotate during electrical operation
Options: Handwheel lockable
Handwheel stem extension
Power tool for emergency operation with square 1 inch [30 mm] or 2 inches [50 mm]
Indication for manual operation Indication whether manual operation is active/not active via single switch (1 change-over contact)
(option)
Electrical connection Standard: AUMA plug & socket connector with screw-type connection
Options: Terminals or crimp connection
Gold-plated control plug (sockets and plugs)
Threads for cable entries Standard: NPT-threads
Options: Pg-threads, metric threads, G-threads
Terminal plan TPA01R1AB-001-AJ3 (1-phase AC motor with permanent split capacitor)
TPA02R1AB-001-AJ3 (1-phase AC motor with starting capacitor and solid state switch 110 – 120 V AC)
TPA03R1AB-001-AJ3 (1-phase AC motor with starting capacitor and solid state switch 220 – 240 V AC)
Depending on motor type/output speed. Refer also to Electrical data SA 07.2 – SA 16.2 with 1-phase AC motors.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Y005.281/065/us Issue 1.16 Page 2/4
SA 07.2 – SA 14.6
AUMA NORM
Technical data Multi-turn actuators for open-close duty with 1-phase AC motors
Valve attachment Standard: B1 according to MSS SP-102
Options: A, B2, B3, B4 according to MSS SP-102
A, B, D, E according to DIN 3210
C according to DIN 3338
Special valve attachments: AF, AK, AG, B3D, ED, DD, IB1, IB3
A prepared for permanent lubrication of stem
Electromechanical control unit
Limit switches Counter gear mechanism for end positions OPEN and CLOSED
Turns per stroke: 2 to 500 (standard) or 2 to 5,000 (option)
Standard: Tandem switch (2 NC and 2 NO) for each end position, switches galvanically isolated
Options: Triple switch (3 NC and 3 NO) for each end position, switches galvanically isolated
Intermediate position switch (DUO limit switches), adjustable for each direction of operation
Gold plated contacts (Au), recommended for low voltage actuator controls
Torque switches Torque switches adjustable for directions OPEN and CLOSE
Standard: Single switch (1 NC and 1 NO) silver contact (Ag) for each direction, not galvanically isolated
Options: Tandem switch (2 NC and 2 NO) for each direction, switches galvanically isolated
Gold plated contacts (Au), recommended for low voltage actuator controls
Position feedback signal, analogue Potentiometer or 0/4 – 20 mA (electronic position transmitter)
(options)
Mechanical position indicator Continuous indication, adjustable indicator disc with symbols OPEN and CLOSED
(option)
Running indication Blinker transmitter
Heater in switch compartment Standard: Self-regulating PTC heater, 5 – 20 W, 110 – 250 V AC/DC
Option: 24 – 48 V DC/DC
A resistance type heater of 5 W, 24 V AC is installed in the actuator in combination with AM or AC actuator controls.
Electronic control unit (only in combination with AC actuator controls)
Non-intrusive setting (option) MWG magnetic limit and torque transmitter
Turns per stroke: 1 to 500 (standard) or 10 to 5,000 (option)
Position feedback signal Via actuator controls
Torque feedback signal Via actuator controls
Mechanical position indicator Continuous indication, adjustable indicator disc with symbols OPEN and CLOSED
(option)
Running indication Blinking signal via controls
Heater in switch compartment Resistance type heater with 5 W, 24 V AC
Service conditions
Use Indoor and outdoor use permissible
Mounting position Any position
Installation altitude ≤ 6,500 ft [2,000 m] above sea level
> 6,500 ft [2,000 m] above sea level on request
Ambient temperature Standard: –22 °F to 158 °F (–30 °C to +70 °C)
Options: –40 °F to 176 °F (–40 °C to +80 °C)
–76 °F to 140 °F (–60 °C to +60 °C)
Humidity Up to 100 % relative humidity across the entire permissible temperature range
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Y005.281/065/us Issue 1.16 Page 3/4
SA 07.2 – SA 14.6
AUMA NORM
Technical data Multi-turn actuators for open-close duty with 1-phase AC motors
Enclosure protection according to Standard: IP68 (NEMA 4X / 6P) with AUMA 1-phase AC motors of types AE..., VE..., AC..., VC...
EN 60529 For special motors, differing enclosure protection is possible
Option: DS terminal compartment additionally sealed against interior of actuator (double sealed)
According to AUMA definition, enclosure protection NEMA 4X / 6P (IP68) meets the following requirements:
•• Depth of water: maximum 26 ft (8 m) head of water
•• Duration of continuous immersion in water: Max. 96 hours
•• Up to 10 operations during continuous immersion
Pollution degree according to Pollution degree 4 (when closed), pollution degree 2 (internal)
IEC 60664-1
Corrosion protection Standard: KS Suitable for use in areas with high salinity, almost permanent condensation, and high pollu-
tion.
Option: KX Suitable for use in areas with extremely high salinity, permanent condensation, and high
pollution.
Coating Double layer powder coating
Two-component iron-mica combination
Color Standard: AUMA silver-gray (similar to RAL 7037)
Option: Available colors on request
Lifetime AUMA multi-turn actuators meet or exceed the lifetime requirements of EN 15714-2. Detailed information can be
provided on request.
Noise level < 72 dB (A)
Further information
Directives and compliances Canadian Standards Association (CSA): (C22.2)
Electromagnetic Compatibility (EMC): (2014/30/EU)
Low Voltage Directive: (2014/35/EU)
Machinery Directive: (2006/42/EC)
Reference documents Product description Electric multi-turn actuators SA .2 with AM .1 and AC .2
Dimensions SA 07.2 – SA 14.6/SAR 07.2 – SAR 14.6 with 1-phase AC motors
Electrical data SA 07.2 – SA 14.6 with 1-phase AC motors
Technical data for switches
Technical data Electronic position transmitter/potentiometer
Technical data Sizing of reduction gearings for mechanical position indication, potentiometers, EWG, RWG and IWG
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Y005.281/065/us Issue 1.16 Page 4/4