Note From Mal Ikx4M E95
Note From Mal Ikx4M E95
(LLE)
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Continuous Multi – stage Counter-current Extraction
where M is the total mass (kg/h) and is a constant, L0 the inlet feed flow rate (kg/h), VN+1 the inlet
solvent flow rate (kg/h), V1 the exit extract stream, and LN the exit raffinate stream. Material balance
on C gives
• The separation of constituents (solutes) of a liquid solution by contact with another insoluble
liquid.
• The separation process of the components of a liquid mixture by treatment with a solvent in
which one or more desired components is soluble.
• The purpose of LLE is to separate closed-boiling point mixture [e.g. acetic acid (118°C) – water
(100°C)]
• component (s) to be removed from the feed must preferentially distribute in the solvent.
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Definition & Application
• Raffinate - The residual liquid from which solutes has been removed.
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Definition & Application
• In some operations, the solutes are the desired product, hence the extract stream is the
desirable stream. In other applications, the solutes my be contaminants that need to be
removed, and in this instance the raffinate is the desirable product stream.
• Extraction processes are well suited to the petroleum industry because of the need to separate
heat – sensitive liquid feeds according to chemical type (e.g aromatic, naphthenic) rather than
by molecular weight or vapor pressure.
• Application:
• In the inorganic chemical industry, they are used to recover high – boiling components
such as phosphoric acid, boric acid and sodium hydroxide from aqueous solution.
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Definition & Application
• Examples:
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Definition & Application
• Examples:
• The difference between LLE and distillation process in the separation of liquid mixtures:
• LLE depends on solubilities between the liquid components and produces new
solution which in turn has to be separated again, whereas;
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Definition & Application
• Presence of azeotropes or low relative volatilities are involved (α value near unity and
distillation cannot be used)
• Recovery of a high – boiling point component present in small quantities in waste stream,
e.g acetic acid from cellulose acetate.
• Recovery of heat – sensitive materials (e.g food) where low to moderate processing
temperatures are needed. Thermal decomposition might occur.
The solvent is the key to a successful separation by LLE. The several criteria:
• Distribution Coefficient.
• This is the ratio (at equilibrium) of the concentration of solute in the extract and raffinate
phases. It gives a measure of the affinity of the solute for the two phases.
• A distribution coefficient other than unity implies that the solute must have different
affinity in the two phases. If only one solute is involved (such as in the recovery of an
impurity from an effluent stream), only the distribution coefficient need to be considered,
and it is desirable for this to be as large as possible.
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Solvent selectivity
• If there are more than one solutes (sat two solutes A and B), then consideration should be
given to the selectivity of the solvent for solutes A against B.
• The selectivity between two solutes A and B is defined as the ratio of the distribution
coefficient of A to the distribution coefficient of B. For all useful extraction operation the
selectivity must exceed unity. If the selectivity is unity, no separation is possible.
• Insolubility of Solvent.
• The solvent should have low solubility in the feed solution, otherwise the separation is not
“clean”. For example, if there is significant solubility of solvent in the raffinate stream, an
additional separation step is required to recover the solvent.
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Solvent selectivity
• Recoverability.
• It is always necessary to recover the solvent for re-use, and this must ordinarily be done
by other means, e.g distillation. If distillation is to be used, the solvent should form no
azeotrope with the extracted solute and mixtures should show high relative volatility. The
solvent should also be thermally – stable under the distillation temperature.
• Density.
• A large difference in density between extract and raffinate phases permits high capacities
in equipment. This is especially important for extraction devices utilizing gravity for phase
separation.
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Solvent selectivity
• Interfacial tension.
• The larger the interfacial tension, the more readily coalescence of emulsions will occur but
the more difficult the dispersion of one liquid in the other will be. The more readily
coalesces the emulsions the easier phase separation will be.
• Low interfacial tension aids dispersion and thus improves contacting mass transfer
efficiency. Coalescence is usually of greater importance, and interfacial tension should
therefore high.
• Chemical Reactivity.
• The solvent should be stable chemically and inert toward the other components of the
system and toward the common materials of construction.
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Solvent selectivity
• These should be low for ease in handling and storage, for example, a high viscosity leads
to difficulties with pumping, dispersion and mass transfer rate.
• An excellent solvent may not commercially available. Or it may represent a large initial
cost for charging the system, and a heavy continuing expense for replacing inevitable
operating losses.
• Other Criteria.
• Toxicity and flammability of the solvent are important occupational health and safety
consideration.
• Stability of the solvent (i.e resistance to breakdown), particularly in the recovery steps, is
significant, especially if the breakdown products might contaminate the products of the
main separation.
Ternary Phase Equilibrium Diagram
• Liquid-liquid system have 3 components: A (Solute), B (Carrier) and C (Solvent) and two phases
in equilibrium: 1) Extract 2) Raffinate
• Example:
1) Methyl isobutyl ketone (A) – Water (B) – Acetone (C)
2) Water (A) – Chloroform (B) – Acetone (C)
3) Benzene (A) – Water (B) – Acetic Acid (C)
4) Acetic Acid (A) – Water (B) – Isopropyl ether (C)
5) Acetone (A) – Water (B) – Trichloroethylene (C)
6) Acetone (A) – Water (B) – Methyl isobutyl ketone (C)
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Ternary Phase Equilibrium Diagram
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Ternary Phase Equilibrium Diagram
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Ternary Phase Equilibrium Diagram
wt% of B
Tie lines:
Show the compositions of the
equilibrium phases
wt% of A
(Solute) (Solvent)
wt% of C
Single – stage Counter-current Extraction
• Solvent and the solution are in contact with each other only once and thus the raffinate and
extract are in equilibrium only once.
• The solution – normally binary solution containing solute (A) dissolved in a diluent or
carrier (B). The extracting solvent can be either pure solvent C or may content little A.
Raffinate (R) is the exiting phase rich in carrier (B) while extract is exiting phase rich in
solvent (C).
• When liquid solution mixed with solvent (C), an intermediate phase M momentarily forms
as the light liquid moves through the heavy liquid in the form of bubbles. These bubbles
provide a large surface area for contact between the solution and the solvent that speed up
mass transfer process.
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Single – stage Counter-current Extraction
Extract, V1 Solvent, V2
Feed, Lo Raffinate, L1
xA0 , xC0 xA1 , xC1
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Single – stage Counter-current Extraction
• In most single – extraction, we are interested to determine the equilibrium composition and
masses of raffinate and extract phases by using ternary phase diagram and simple material
balances.
Overall: L0 + V2 = L1 + V1 = M (1)
• To find the final compositions in the two phases, it is required to know the mixture total
mass and composition (point M).
• After point M is identified, the product composition can be found by the equilibrium tie
line.
Single – stage Counter-current Extraction
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Single – stage Counter-current Extraction
Point g
Extract layer
Point M
tie line
Point i
Raffinate layer
45° line
equilibrium line
Example 12.5-2
• A single-stage extraction is performed in which 400 kg of a solution containing 35 wt% acetic acid
in water is contacted with 400 kg of pure isopropyl ether. Calculate the amounts and compositions
of the extract and raffinate layers. What percent of the acetic acid is removed? Use equilibrium
data from Appendix A.3-24.
Appendix A.3-24
Acetic acid (A) - Water (B) - Isopropyl Ether
(C) System
Mol fraction
Water layer (wt%) Ether (wt%) Water layer, x Ether layer, y
A B C A B C xA xB xC yA yB yC
0 98.8 1.2 0 0.6 99.4 0 0.988 0.012 0 0.006 0.994
0.69 98.1 1.2 0.18 0.5 99.3 0.0069 0.981 0.012 0.0018 0.005 0.993
1.41 97.1 1.5 0.37 0.7 98.9 0.0141 0.971 0.015 0.0037 0.007 0.989
2.89 95.5 1.6 0.79 0.8 98.4 0.0289 0.955 0.016 0.0079 0.008 0.984
6.42 91.7 1.9 1.93 1 97.1 0.0642 0.917 0.019 0.0193 0.01 0.971
13.3 84.4 2.3 4.82 1.9 93.3 0.133 0.844 0.023 0.0482 0.019 0.933
25.5 71.1 3.4 11.4 3.9 84.7 0.255 0.711 0.034 0.114 0.039 0.847
36.7 58.9 4.4 21.6 6.9 71.5 0.367 0.589 0.044 0.216 0.069 0.715
44.3 45.1 10.6 31.1 10.8 58.1 0.443 0.451 0.106 0.311 0.108 0.581
46.4 37.1 16.5 36.2 15.1 48.7 0.464 0.371 0.165 0.362 0.151 0.487
0.464 0.165
Example 12.5-2
Continuous Multi – stage Counter-current Extraction
• Single-stage equilibrium contact was used to transfer solute A from one liquid to another liquid phase.
• To transfer more solute, single-stage contact can be repeated by bringing the exit L1 stream into contact
with fresh solvent, V2.
• Therefore, a greater percentage removal of solute A is obtained. However, this is wasteful of the solvent
stream as well as giving a dilute product of A in the outlet solvent extract streams.
• In order to use less solvent and to obtained more concentrated exit extract stream, counter-current
multistage is used.
• Solvent and solution which flow opposite (countercurrent) to each other, come into contact more than
once and mix on stages inside the reactor.
• Normally numbering of the stages begin at the top down to the bottom. Thus the top most stage is
named as stage 1, stage directly below stage 1 is stage 2 and so on.
• The analysis of multistage extraction can be performed using right – angle or equilateral triangular
diagram to determine the number of ideal stages required for a specified separation.
Continuous Multi – stage Counter-current Extraction
• To find the compositions and the amount of extract and raffinate streams:
1. Plot ternary phase diagram (equilateral/right-angle)
2. Find the values of yAN+1, yCN+1 (composition of A&C in solvent), xA0, xC0 (composition of
A&C in feed), xAN, xCN (composition of A&C in raffinate) and xAM, xCM (composition of
A&C in mixture)
3. Plot VN+1 (yAN+1, yCN+1), L0 (xA0, xC0), LN (xAN, xCN) and M (xAM, xCM)
4. V1 is located by drawing a line from LN through M & extending it until it intersects the
phase boundary in the extract phase. This give yA1 and yC1 (compositions of A&C in
extract stream)
5. Find the amount of extract (V1) and raffinate (LN) using material balance.
VN+1
(yAN+1, yCN+1)
V1
(yA1, yC1)
L0
LN (xA0, xC0)
(xAN, xCN)
Continuous Multi – stage Counter-current Extraction
M
(xAM, xBM, xCM)
V1 Plait Point
(yA1, yB1, yC1) L0
V1 (xA0, xB0, xC0)
L0
VN+1 M Operating Point
(yAN+1, yBN+1, yCN+1) Δ
LN LN
VN+1 (xAN, xBN, xCN)
(Solvent) (Carrier/Diluent)
Example 12.7-1
Pure solvent isopropyl ether (C) at the rate of VN+1 = 600 kg/h is being used to extract an aqueous
solution of L0 = 200 kg/h containing 30 wt % acetic acid (A) and 70 wt % water (B) by countercurrent
multistage extraction. The desired exit acetic acid concentration in the aqueous phase is 4%. Calculate
the compositions and amounts of the ether extract V1 and the aqueous raffinate LN. Use equilibrium
data from Appendix A.3-24.
Appendix A.3-24
Acetic acid (A) - Water (B) - Isopropyl Ether (C) System
Mol and mass fraction
Water layer (wt%) Ether (wt%) Water layer, x Ether layer, y
A B C A B C A B C A B C
0 98.8 1.2 0 0.6 99.4 0 0.988 0.012 0 0.006 0.994
0.69 98.1 1.2 0.18 0.5 99.3 0.0069 0.981 0.012 0.0018 0.005 0.993
1.41 97.1 1.5 0.37 0.7 98.9 0.0141 0.971 0.015 0.0037 0.007 0.989
2.89 95.5 1.6 0.79 0.8 98.4 0.0289 0.955 0.016 0.0079 0.008 0.984
6.42 91.7 1.9 1.93 1 97.1 0.0642 0.917 0.019 0.0193 0.01 0.971
13.3 84.4 2.3 4.82 1.9 93.3 0.133 0.844 0.023 0.0482 0.019 0.933
25.5 71.1 3.4 11.4 3.9 84.7 0.255 0.711 0.034 0.114 0.039 0.847
36.7 58.9 4.4 21.6 6.9 71.5 0.367 0.589 0.044 0.216 0.069 0.715
44.3 45.1 10.6 31.1 10.8 58.1 0.443 0.451 0.106 0.311 0.108 0.581
46.4 37.1 16.5 36.2 15.1 48.7 0.464 0.371 0.165 0.362 0.151 0.487
0.464 0.165
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Example 12.7-2
Pure isopropyl ether (C) of 450 kg/h is being used to extract an aqueous solution of 150 kg/h with 30
wt % acetic acid (A) and 70 wt % water (B) by countercurrent multistage extraction. The exit acid
concentration in the aqueous phase is 10 wt %. Calculate the number of stages required.
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Example 12.7-1 & 2
Example – using equilateral triangular diagram
A 1000 kg/h mixture of 30 wt% acetic acid and 70 wt % water is to be fed to a countercurrent
extraction process. The solvent is 99 wt% isopropyl ether and 1 wt % acetic acid and has an inlet flow
rate of 2500 kg/h. The raffinate stream should contain 5 wt % acetic acid.
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Example – using equilateral triangular diagram
Water(B) Ether(C)
Minimum Solvent Rate
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Problem 12.7-3
An aqueous feed solution of 1000 kg/h containing 23.5 wt % acetone and 76.5 wt % water is being
extracted by countercurrent multistage extraction using pure MIK solvent at 298 K. The outlet water
raffinate will contain 2.5 wt % acetone. Calculate the minimum solvent that can be used. Using a
solvent flowrate of 1.5 times the minimum, calculate the number of stages required.
Composition data (wt%) Acetone Distribution data (wt%) Mass fraction Mass fraction of acetone
MIK (C ) Acetone (A) Water (B) Water phase MIK phase MIK (C ) Acetone (A) Water (B) Water phase (xA) MIK phase (yA)
98 0 2 0 0 0.98 0 0.02 0 0
93.2 4.6 2.33 2.5 4.5 0.932 0.046 0.0233 0.025 0.045
77.3 18.95 3.86 5.5 10 0.773 0.1895 0.0386 0.055 0.1
71 24.4 4.66 7.5 13.5 0.71 0.244 0.0466 0.075 0.135
65.5 28.9 5.53 10 17.5 0.655 0.289 0.0553 0.1 0.175
54.7 37.6 7.82 12.5 21.3 0.547 0.376 0.0782 0.125 0.213
46.2 43.2 10.7 15.5 25.5 0.462 0.432 0.107 0.155 0.255
12.4 42.7 45 17.5 28.2 0.124 0.427 0.45 0.175 0.282
5.01 30.9 64.2 20 31.2 0.0501 0.309 0.642 0.2 0.312
3.23 20.9 75.8 22.5 34 0.0323 0.209 0.758 0.225 0.34
2.12 3.73 94.2 25 36.5 0.0212 0.0373 0.942 0.25 0.365
2.2 0 97.8 26 37.5 0.022 0 0.978 0.26 0.375
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Problem 12.7-3
Problem 12.7-3
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Problem 12.7-3
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Counter-current Stage Extraction with Immiscible Liquid
• If the component stream VN+1 contains components A and C and feed stream L0 contains A and B and
if components B and C are relatively immiscible in each other, the stage calculations may be made more
easily.
• The solute A is relatively dilute and is being transferred from L0 to VN+1.
• Overall balance for A:
L’ = kg inert B/h (pure B)
V’= kg inert C/h (pure C)
y = mass fraction A in V stream
x = mass fraction A in L stream
= LN (1 – xN) = V1 (1 – y1)
• Operating line is plotted at
(xAN, yAN+1) and (xA0, yA1)
• Kremser equation • If diluted solution, operating
line is a straight line
• If not diluted solution,
operating line is slightly curve
line
Example 12.7-3
An inlet water solution of 100 kg/h containing 0.010 wt fraction nicotine in water is stripped with a
kerosene stream of 200 kg/h containing 0.0005 wt fraction nicotine in a countercurrent stage tower.
The water and kerosene are essentially immiscible in each other. It is desired to reduce the
concentration of the exit water to 0.0010 wt fraction nicotine. Calculate the flow rate of the nicotine in
both of the exit streams. Determine the theoretical number of stages needed. The equilibrium data are
as follows with x the weight fraction of nicotine in the water solution and y in the kerosene.
Plot the equilibrium data and graphically determine the number of stages
Use Kremser equation to determine the number of stages
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Example 12.7-3
Figure 12.7-6. Solution for extraction with immiscible liquids in Example 12.7-3.
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Counter-current Stage Extraction with Immiscible Liquid –
Minimum Solvent
• In extraction process, the inlet feed flow (L0) and its solute
composition (xA0) are usually set.
• The solute concentration in raffinate (xAN) is often set by the
designer.
• The solute concentration in solvent (yAN+1) is generally fixed
by the process requirements in regenerating the solvent for
recycle back to the tower.
• Hence, the amount of the entering solvent (VN+1) is open to
choose.
• Minimum solvent (V’min) is when the operating line has a
maximum slope and touches the equilibrium line at point P
(point xA0).
• The value of yA1 is at a maximum (yA1max).
• Optimum flowrate is taken at 1.2-1.5 times V’min with 1.5
normally used.
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Example 12.7-4
Example 12.7-4
• A mechanical mixer is often used to provide intimate contact between the two liquid
phases – to provide efficient mass transfer.
• One phase is usually dispersed into the other in the form of small droplet.
• In figure 12.6 – 1(a) for typical mixer settler, mixer or agitator is entirely separate from
the settler. The feed of aqueous phase and organic phase are mixed in the mixer, and
then the mixed phases are separated in the settler.
• In figure 12.6 – 1(b) for combined mixer settler, sometimes used in extraction of
uranium salts or copper salts from aqueous solution.
Liquid – liquid extraction equipment
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Liquid – liquid extraction equipment
Reference: Geankoplis, C.J. (2014), Transport Processess & Unit Operations, 4th Edition, Pearson New International Edition
Liquid – liquid extraction equipment
• Packed Extraction Towers
Liquid – liquid extraction equipment