8 7 6 5 4 3 2 1

REVISIONS
REV. ECO DATE DESCRIPTION AUTH. DR.
LIFTING POINT
196
REQ. FOR ELEMENT REMOVAL
7.7 5.13 [130] MAX DIA 133
5.2
762 LIFTING POINT
25 30.0
D
1.0 NPT 5 1 D
.97 OUTLET

0.75NPT 508
20.00 622
MTG 24.5

584
79 23.00
C 3.1
C

38 53
38 1.50 TYP MTG 2.1
1.50 7 4 38
.38 DIA MTG
HOLE (6X) NOTES: 1.5
151 19
546 508 1. REFERENCE SYSTEM MODEL AND SERIAL NUMBER WHEN
5.9 .75 TYP MTG ORDERING REPLACEMENT PARTS.
21.50 TYP MTG 20.00 TYP MTG
2. ACCEPTABLE MOUNTING ORIENTATION SHOWN.
INLET
POWER IN CONTROL SIGNAL 1.5NPT 3. FOR CONTROL BOX REF DWG# A-7417-2S, FOR WIRING
1.0 NPT 0.75 NPT SCHEMATIC REF DWG# A-7417-3.
B B
4. LOCAL/OFF/REMOTE SWITCH OPERATION:
51 LOCAL POSITION - SYSTEM ON
2.0 OFF POSITION - SYSTEM OFF
REMOTE POSITION - AUTOMATIC OPERATION VIA
CUSTOMER SIGNAL

344 5. RESET BUTTON USED TO RESET MOTOR PROTECTIVE SWITCH.


13.6
6. DIMENSIONS IN PARENTHESES ARE FOR REFERENCE ONLY.
151 174
6.9 7. PRIME BUTTON USED FOR START UP AND
5.9 WHEN FLUID IS REFILLED TO MAKE SURE FLUID IS
CIRCULATING THROUGH THE SYSTEM.

84
3.3 HOTSTART, INC. SPOKANE, WA. A
44 PROPRIETARY INFORMATION
A 1.75 This drawing and the information shown on it are property of Hotstart, Inc.
219 127 and are for the sole purpose of doing business with us. Any copying or transmittal to others
of this information is strictly prohibited without prior written consent Hotstart.
8.6 5.0 TITLE
OLA OIL EX. RESISTANT 3HP ATEX HEATING SYSTEM
1092 APPROVALS DATE
UNLESS OTHERWISE SPECIFIED
DWG. NO.

43.00 DRAWN BY
KF 03-12-12
DIMENSIONS ARE IN INCHES [mm]

TOLERANCES
A-7637-0S
1201 APPROVED BY (Except as noted)
SIZE ORIGIN
BJH 03-13-12 .XX
B
47.3 .13 ANGULAR
CO7536
THIRD ANGLE .XXX N/A N/A SCALE SHEET REV.
PROJECTION DO NOT SCALE DRAWING 1:8 1 OF 2 00
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
REVISIONS
REV. ECO DATE DESCRIPTION AUTH. DR.

OIL ELEMENT
ASSEMBLY

D PUMP D
PRIME HIGH LIMIT
BUTTON TEMP PROBE

MOTOR
RESET
BUTTON

CONTROL BOX

PRESSURE GAUGE

TEMP PROBE
C C

SW1
LOCAL / OFF / REMOTE
SWITCH

B B

MOTOR
OIL PUMP

PRESSURE
RELIEF VALVE

HOTSTART, INC. SPOKANE, WA. A


PROPRIETARY INFORMATION
A This drawing and the information shown on it are property of Hotstart, Inc.
and are for the sole purpose of doing business with us. Any copying or transmittal to others
of this information is strictly prohibited without prior written consent Hotstart.
TITLE
OLA OIL EX. RESISTANT 3HP ATEX HEATING SYSTEM
APPROVALS DATE DWG. NO.
UNLESS OTHERWISE SPECIFIED

OLA PART NUMBERS


DRAWN BY
KF 03-12-12
DIMENSIONS ARE IN INCHES [mm]

TOLERANCES
A-7637-0S
APPROVED BY (Except as noted)
SIZE ORIGIN
PART NO. DESCRIPTION BJH 03-13-12 .XX
B
.13 ANGULAR
CO7536
N/A N/A
OLA3025A‐F40 OLA 400V 50Hz 3P 2.5kW 3HP 1450RPM 24GPM 24VDC IP66 THIRD ANGLE .XXX SCALE SHEET REV.
PROJECTION DO NOT SCALE DRAWING 1:6 2 OF 2 00
8 7 6 5 4 3 2 1