0% found this document useful (0 votes)
82 views8 pages

FC721-ZZ Datasheet en

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
82 views8 pages

FC721-ZZ Datasheet en

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Cerberus PRO

FC721
Fire control panel
Series FS720 (IP4)

 Compact, prefabricated, microprocessor-controlled fire control panel for the


connection of up to 126 addresses
 Fire control panel can be used as stand-alone version
 Integrated emergency operation function
 Fast Ethernet interface for remote control service
 Integrated user-friendly operating unit
 Optional key switch
 Slot for a RS232 or a RS485 serial port
 Emergency power supply for up to 72 h emergency power time
 Detection and automatic read-in (auto configuration) of all C-NET devices, pro-
viding immediate simple operation
 Processes signals from the Cerberus PRO FD720 detector series
 Floor repeater displays, operating panels and alarm devices in the detector
loop (C-NET)
 Flexible programming of complex applications and controls
 Stored data can be uploaded via remote access
 Firmware download of all processor controlled control panel components

Building Technologies
CPS Fire Safety
System overview

Remote access
Engineering Tool,
Operating Tool
FC721
Fire control panel

DM110x avoid e
lectr ost at ic
charging !

Detection line collective Siemens,


SynovaTM SynoLINE300 or
Explosion- DT110x-Ex
SynoLINE600 RT- Alarm
ec
avoid el tro stat ic
charging!

hazard area
DO1101-Ex SB3 RT-Fault via
FCI2007-A1
24VDC ext.
or

FDCI222
FDCIO223
Fire controls
FDS221
2 in-/outputs via FC2008-A1
FT2011 optionally HI720
Floor repeater FDCL221
display
4 inputs OP720 OP720 Conventional horn line
C-NET via FCI2009-A1
DBS721 / DBS729 OH720
1 loop stub line
DBS720
max. 126 addresses 1 Output

HI722 FDCIO221
FT2010
24VDC ext. Floor repeater terminal
possible OH720
1 input
4 outputs FDCI221
FDS229
FDCIO222

24VDC ext.
FDM22x possible
Mimic display
FDM221
FT2001-A1 1 input
4 inputs

Characteristics

– The FC721 is a compact fire control panel with an integrated operating unit that can
process signals from FD720 devices.
– The control panel can be programmed with the user-friendly Cerberus-Engineering-
Tool.
– All detector lines are monitored for ground faults.
– Adaptation of the user text directly on the terminal or with the software engineering
tool.
– Up to 2000 events can be stored according to various criteria.
– Automatic summer/winter time change.

2
Building Technologies
CPS Fire Safety
Functional elements

Operating unit
The following are located on the operating unit:
– CPU module and the electronics for the operating unit
– Ethernet connection
– Slots for RS232, RS485 modules
– Space for 'Kaba' or 'Nordic' key switch

Periphery board
The following are located on the periphery board:
– Connection terminals for C-NET loops, remote transmission (alarm, fault), horn
output, programmable control inputs/outputs, monitored alarm and fault output,
degrade supply, power supply

Power supply 70 W, emergency power supply


The power supply supplies the hardware and charges the batteries
– The batteries supply the emergency power in case of power failure

Configuration
The FXS7212 Cerberus-Engineering-Tool permits the system to be adapted to specific
customers' requirements.

Application ranges

The FC721 is ideally suited for smaller applications, e.g. in workshops, hotels, etc.

3
Building Technologies
CPS Fire Safety
Display and operating elements

 Each control panel has an integrated operating unit.

1 Large-format, backlit plain text display (LCD 256


x 112 dots) with detailed plain text information for
all events that occur
– Event type, event location, reaction texts,
operating status, etc.
– Operator guidance texts are displayed directly
in alarm situations
– Convenient operation via soft keys and navi-
gation key
2 Alarm indicator lights red when an alarm even is
received
3 4 programmable LEDs and div. display fields
4 Soft keys for direct menu operation
5 2 operation keys with LEDs, individually pro-
grammable
6 Keys –> 'Buzzer off', 'Acknowledge' message
and 'Reset' message
7 Key for scrolling through the alarm messages
8 Navigation and menu key for the display
9 Keypad for numerical and alphanumeric entries
such as password, customer text, etc.
10 Function keys for alarm organization
11 Display and key field for alarming equipment
12 Optional key switch for operating access (Kaba
or Nordic)
13 Label strips inserts.
14 With 24 indicator groups with each one red +
yellow LED

4
Building Technologies
CPS Fire Safety
Overview of FC721 fire control panels

Housing (Eco)
FC721-ZZ FC721-YZ
With 24 indicator groups
with each one red + yellow LED

1 Loop 1 Loop
With power supply (70 W) With power supply (70 W)
Battery capacity max. 7 Ah Battery capacity max. 7 Ah

Expansion
FH7201-Z3 FH7202-Z3
Housing (Eco) Housing (Standard)
430 x 398 x 80 mm 430 x 398 x 160 mm

Empty housing Empty housing


For various applications e.g. For various applications e.g.
for event printer for additional power supply
Space for batteries
2 x FA2004-A1 (12 Ah) or
2 x FA2006-A1 (26 Ah)
+ Power supply kit (150 W)

Internal printer External printer


FTO2001-A1 DL3750+
Event printer Matrix printer (Extern)
RS232 interface

installable in empty housings


RS232 module must be ordered
separately
RS232 module must be ordered
separately

5
Building Technologies
CPS Fire Safety
Configuration FC721

11

2 13
4 7 1
5
9

6
10 8
12

Basic equipment Designation Notes


1 Rear (Eco) FHA2001-A1
2 Periphery board (1-Loop) FCI2010-A1 Pos. 1-5 –> Basic equipment for each FC721 (Eco)
3 Power supply (70 W) FP2001-A1
4 Mains terminals on DIN mounting rail TS35 – Space for 2 relay modules
5 Operating unit FCM7xx-xx Combined system operating panel and CPU, incl. cover
6 Space for batteries – 2 x 12 V / 7 Ah
Expansion
7 Relay module Z3B171 Relay for fire controls
Key switch (Kaba) FTO2005-C1
8 For operating access rights
Key switch (Nordic) FTO2006-B1
RS485 module (isolated) or FCA2002-A1 For peripheral devices with RS485 port
9
RS232 module(isolated) FCA2001-A1 For stations with RS232 port
10 Battery (12V, 7Ah, VDS) FA2003-A1 For emergency power supply
rd
11 19" mounting kit FHA2016-A1 For the installation in 3 party housings
12 License key L1 FCA2012-A1 For Cerberus-Remote
13 Cable kit (communication) FCA2014-A1 For flexible cable connections to the modules on the operating
unit

6
Building Technologies
CPS Fire Safety
Technical data

Mains voltage AC 85… 265 V


Power supply 70 W
Operating voltage DC 21… 28.6 V
Operating current max. 2.5 A
Battery capacity 2 x 12 V, 7 Ah
Battery monitoring yes
Mains monitoring yes
Connectable detector series Cerberus PRO FD720 (C-NET)
Number of lines
– Loop or 1
– Stub lines 2
Number of addresses max. 126
Integrated inputs/outputs
– Relay output
– RT alarm 1
– RT fault 1
– Monitored outputs
– Alarm 1
– Fault 1
– Horn 1
– Free programmable inputs/outputs 4
Operating unit integrated
Plug-in position for serial interfaces RS232, RS485 1
Mounting place for cable kit (communication) 1
Ethernet connection RJ45 1
Operating temperature -8… +42 °C
Storage temperature -20… +60 °C
Humidity (no condensation permitted) ≤95 % rel.
Dimensions (W x H x D)
– Without cover cap 430 x 398 x 80 mm
– With cover cap 430 x 398 x 108 mm
Color
– Housing grey, ~RAL 7035
– Cover grey, ~RAL-Design 050 00 00
Protection category (IEC 60529) IP30
Standards EN 54-2, EN 54-4
Approvals
– VdS pending
– LPCB 126aw/05

7
Building Technologies
CPS Fire Safety
Details for ordering

Type Part no Designation Weight


Fire control panels FC721-ZZ S54400-C32-A2 Fire control panel (1L) 8.900 kg
FC721-YZ S54400-C32-A3 Fire control panel (1L, 1LED) 9.000 kg
Expansion Z3B171 BPZ:4843830001 Relay module 250 VAC / 10 A (1 relay) 0.042 kg
FTO2001-A1 A5Q00010126 Event printer 0.250 kg
– A5Q00017619 Replacement printer rolls (10 rolls) 0.090 kg
FTO2005-C1 A5Q00010113 Key switch (Kaba) 0.013 kg
FTO2006-B1 A5Q00010129 Key switch (Nordic) 0.050 kg
FCA2002-A1 A5Q00009923 RS485 module (isolated) 0.067 kg
FCA2001-A1 A5Q00005327 RS232 module (isolated) 0.068 kg
FCA2014-A1 A5Q00023027 Cable kit (communication) 0.224 kg
FH7201-Z3 S54400-B72-A101 Housing (Eco) 5.700 kg
FH7202-Z3 S54400-B70-A101 Housing (Standard) 7.500 kg
FHA2016-A1 A5Q00020179 19" mounting kit 3.000 kg
FN2006-A1 S54400-A109-A1 Fiber network module (SM) 0.770 kg
FN2007-A1 S54400-A110-A1 Fiber network module (MM) 0.770 kg
Additional power supply FP2003-A1 A5Q00016005 Power supply kit (70 W) 0.650 kg
FP2004-A1 A5Q00020825 Power supply kit (150 W) for installation in 1.366 kg
empty housing
Batteries FA2003-A1 A5Q00019353 Battery (12 V, 7 Ah, VDS) 2.450 kg
FA2004-A1 A5Q00019354 Battery (12 V, 12 Ah, VDS) 3.930 kg
FA2006-A1 A5Q00019356 Battery (12 V, 26 Ah, VDS) 7.572 kg
Software license FCA2012-A1 A5Q00018856 License key (L1) 0.010 kg
External printer DL3750+ A5Q00023962 Matrix printer (Extern) 7.300 kg
Spare part – A5Q00023963 Black typewriter ribbon for matrix printer 0.078 kg
DL3750+

Siemens Switzerland Ltd


Infrastructure & Cities Sector
Building Technologies Division
International Headquarters © 2012 Copyright by
CPS Fire Safety Siemens Switzerland Ltd
Gubelstrasse 22
CH-6301 Zug Data and design subject to change without notice.
Tel. +41 41 724 24 24 Supply subject to availability.
www.siemens.com/buildingtechnologies
Document no. A6V10203220_d_en_-- Manual FS720
Edition 04.2012 Section 1

You might also like