COMPRESSOR TECHNICAL DATA
COMPRESSOR DEFINITION
Designation VNE K207U
Nominal Voltage/Frequency 100-300 V 33-75 Hz
Engineering Number 860BX71
A - APPLICATION / LIMIT WORKING CONDITIONS
1 Type Hermetic reciprocating compressor
2 Refrigerant R-290
3 Nominal voltage and frequency 100-300 / 33-75 [ V / Hz ]
4 Application type Low Back Pressure R290
4.1 Evaporating temperature range -40°C to -10°C (-40°F to 14°F)
5 Motor type BPM
6 Starting torque HST - Hight starting torque
7 Expantion device Capillary tube or Expansion valve
8 Compressor cooling Operating voltage range
50 Hz 60 Hz
8.1 LBP (32ºC Ambient temperature) - - -
8.2 LBP (43ºC Ambient temperature) - - -
8.3 HBP (32ºC Ambient temperature) - - -
8.4 HBP (43ºC Ambient temperature) - - -
9 Maximum condensing temperature
9.1 Operating 18.4 [kgf/cm²] (262 psig) / ºC - ºF
9.2 Peak 20.6 [kgf/cm²] (293 psig) / ºC - ºF
10 Maximum winding temperature 130 [ °C ]
B - MECHANICAL DATA
1 Commercial designation [hp]
2 Displacement 7.28 [cm³] (0.444 cu.in)
2.1 Bore [mm] 26.497
2.2 Stroke [mm] 13.200
3 Lubricant charge 500 [ml] (16.91 fl.oz.)
3.1 Lubricants approved
3.2 Lubricants type/viscosity ESTER / ISO22
4 Weight (with oil charge) 11.6 [kg] (25.57 lb.)
5 Nitrogen charge - [kgf/cm²]
C - ELETRICAL DATA
1 Nominal Voltage/Frequency/Number of Phases 100-300 V 33-75 Hz 3 ~ (Three phase)
2 Starting device type Inverter
2.1 Starting device CF10C01 M 0.1 X
3 Start capacitor - [µF(VAC minimum)]
4 Run capacitor - [µF(VAC minimum)]
5 Motor protection MST00LJ
6 Start winding resistance 3.82 [W at 25ºC (77ºF)] +/- 8%
7 Run winding resistance 2.53 [W at 25ºC (77ºF)] +/- 8%
8 LRA - Locked rotor amperage (50/60 Hz) - [A] - Measured according to UL 984
9 FLA - Full load amperage L/MBP (50/60 Hz) - [A] - Measured according to UL 984
10 FLA - Full Load Amperage HBP (50/60 Hz) - [A] - Measured according to UL 984
11 Approval boards certification VDE
UPDATE: 28OCT2021 860BX71
COMPRESSOR TECHNICAL DATA
D - PERFORMANCE - CHECK POINT DATA
TEST CONDITIONS: EN12900LBP_HH Evaporating temperature -35°C (-31°F)
@220V2000RPM Static (Condensing temperature 40°C (104°F))
Power Current Gas flow EFFICIENCY RATE
Cooling capacity consumption consumption rate
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
[Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
446 112 131 115 0.56 1.41 3.88 0.98 1.14
TEST CONDITIONS: EN12900LBP_HH Evaporating temperature -35°C (-31°F)
@220V2000RPM Fan (Condensing temperature 40°C (104°F))
Power Current Gas flow EFFICIENCY RATE
Cooling capacity consumption consumption rate
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
[Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
446 112 131 115 0.56 1.41 3.88 0.98 1.14
TEST CONDITIONS: EN12900LBP_HH Evaporating temperature -35°C (-31°F)
@220V2400RPM Fan (Condensing temperature 40°C (104°F))
Power Current Gas flow EFFICIENCY RATE
Cooling capacity consumption consumption rate
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
[Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
506 128 148 135 0.65 1.60 3.75 0.95 1.10
TEST CONDITIONS: EN12900LBP_HH Evaporating temperature -35°C (-31°F)
@220V3000RPM Fan (Condensing temperature 40°C (104°F))
Power Current Gas flow EFFICIENCY RATE
Cooling capacity consumption consumption rate
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
[Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
662 167 194 176 0.83 2.09 3.76 0.95 1.10
TEST CONDITIONS: EN12900LBP_HH Evaporating temperature -35°C (-31°F)
@220V4500RPM Fan (Condensing temperature 40°C (104°F))
Power Current Gas flow EFFICIENCY RATE
Cooling capacity consumption consumption rate
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
[Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
976 246 286 271 1.26 3.09 3.60 0.91 1.05
UPDATE: 28OCT2021 860BX71
COMPRESSOR TECHNICAL DATA
E - PERFORMANCE - CURVES
TEST CONDITIONS: EN12900HH (Condensing temperature 35ºC (+95ºF) )
@220V2000RPM Fan
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-40 (-40) 345 87 101 96 0.47 1.04 3.59 0.90 1.05
-35 (-31) 449 113 132 109 0.53 1.36 4.14 1.04 1.21
-30 (-22) 586 148 172 120 0.58 1.78 4.87 1.23 1.43
-25 (-13) 756 190 221 131 0.63 2.30 5.77 1.45 1.69
-20 (- 4) 958 242 281 141 0.68 2.93 6.79 1.71 1.99
-15 (+ 5) 1194 301 350 151 0.72 3.66 7.92 2.00 2.32
-10 (+14) 1462 368 428 160 0.76 4.51 9.13 2.30 2.68
TEST CONDITIONS: EN12900HH (Condensing temperature 45ºC (+113ºF) )
@220V2000RPM Fan
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-40 (-40) 270 68 79 98 0.49 0.89 2.75 0.69 0.81
-35 (-31) 350 88 103 112 0.54 1.16 3.14 0.79 0.92
-30 (-22) 464 117 136 126 0.60 1.54 3.69 0.93 1.08
-25 (-13) 612 154 179 139 0.66 2.03 4.38 1.10 1.28
-20 (- 4) 793 200 232 153 0.72 2.65 5.19 1.31 1.52
-15 (+ 5) 1009 254 296 166 0.78 3.38 6.08 1.53 1.78
-10 (+14) 1258 317 369 179 0.84 4.24 7.03 1.77 2.06
TEST CONDITIONS: EN12900HH (Condensing temperature 35ºC (+95ºF) )
@220V2400RPM Fan
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-40 (-40) 421 106 123 116 0.56 1.27 3.63 0.91 1.06
-35 (-31) 546 138 160 130 0.62 1.66 4.21 1.06 1.23
-30 (-22) 709 179 208 143 0.68 2.15 4.95 1.25 1.45
-25 (-13) 908 229 266 156 0.74 2.76 5.81 1.46 1.70
-20 (- 4) 1144 288 335 169 0.79 3.49 6.78 1.71 1.99
-15 (+ 5) 1416 357 415 181 0.85 4.35 7.83 1.97 2.29
-10 (+14) 1726 435 506 193 0.90 5.32 8.94 2.25 2.62
UPDATE: 28OCT2021 860BX71
COMPRESSOR TECHNICAL DATA
E - PERFORMANCE - CURVES
TEST CONDITIONS: EN12900HH (Condensing temperature 45ºC (+113ºF) )
@220V2400RPM Fan
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-40 (-40) 314 79 92 118 0.58 1.04 2.66 0.67 0.78
-35 (-31) 416 105 122 133 0.64 1.38 3.13 0.79 0.92
-30 (-22) 556 140 163 149 0.71 1.84 3.74 0.94 1.10
-25 (-13) 734 185 215 165 0.78 2.44 4.45 1.12 1.30
-20 (- 4) 949 239 278 181 0.85 3.17 5.23 1.32 1.53
-15 (+ 5) 1203 303 352 198 0.92 4.03 6.08 1.53 1.78
-10 (+14) 1494 377 438 215 0.99 5.03 6.95 1.75 2.04
TEST CONDITIONS: EN12900HH (Condensing temperature 35ºC (+95ºF) )
@220V3000RPM Fan
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-40 (-40) 505 127 148 149 0.71 1.53 3.40 0.86 1.00
-35 (-31) 673 170 197 166 0.79 2.04 4.06 1.02 1.19
-30 (-22) 887 223 260 183 0.86 2.69 4.85 1.22 1.42
-25 (-13) 1146 289 336 200 0.93 3.49 5.74 1.45 1.68
-20 (- 4) 1450 365 425 216 1.01 4.43 6.72 1.69 1.97
-15 (+ 5) 1799 453 527 232 1.08 5.52 7.77 1.96 2.28
-10 (+14) 2193 553 643 247 1.15 6.76 8.87 2.23 2.60
TEST CONDITIONS: EN12900HH (Condensing temperature 45ºC (+113ºF) )
@220V3000RPM Fan
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-40 (-40) 417 105 122 151 0.72 1.38 2.75 0.69 0.80
-35 (-31) 555 140 163 172 0.81 1.84 3.23 0.81 0.95
-30 (-22) 734 185 215 192 0.90 2.43 3.82 0.96 1.12
-25 (-13) 956 241 280 212 0.99 3.18 4.50 1.13 1.32
-20 (- 4) 1218 307 357 232 1.08 4.06 5.24 1.32 1.53
-15 (+ 5) 1522 384 446 253 1.18 5.10 6.03 1.52 1.77
-10 (+14) 1867 471 547 273 1.27 6.29 6.84 1.72 2.01
UPDATE: 28OCT2021 860BX71
COMPRESSOR TECHNICAL DATA
E - PERFORMANCE - CURVES
TEST CONDITIONS: EN12900HH (Condensing temperature 55ºC (+131ºF) )
@220V3000RPM Fan
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-40 (-40) 334 84 98 151 0.72 1.22 2.21 0.56 0.65
-35 (-31) 450 113 132 174 0.82 1.64 2.60 0.66 0.76
-30 (-22) 604 152 177 197 0.93 2.21 3.07 0.77 0.90
-25 (-13) 796 201 233 221 1.04 2.93 3.60 0.91 1.06
-20 (- 4) 1026 258 301 245 1.15 3.79 4.18 1.05 1.22
-15 (+ 5) 1293 326 379 270 1.26 4.80 4.78 1.21 1.40
-10 (+14) 1597 403 468 296 1.38 5.96 5.40 1.36 1.58
TEST CONDITIONS: EN12900HH (Condensing temperature 35ºC (+95ºF) )
@220V3600RPM Fan
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-40 (-40) 644 162 189 183 0.86 1.95 3.51 0.88 1.03
-35 (-31) 859 217 252 205 0.95 2.60 4.20 1.06 1.23
-30 (-22) 1121 283 329 226 1.05 3.41 4.97 1.25 1.46
-25 (-13) 1431 361 419 247 1.14 4.36 5.81 1.46 1.70
-20 (- 4) 1788 451 524 267 1.24 5.46 6.70 1.69 1.96
-15 (+ 5) 2193 553 643 287 1.33 6.73 7.64 1.93 2.24
-10 (+14) 2646 667 775 307 1.42 8.15 8.61 2.17 2.52
TEST CONDITIONS: EN12900HH (Condensing temperature 45ºC (+113ºF) )
@220V3600RPM Fan
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-40 (-40) 487 123 143 182 0.86 1.61 2.69 0.68 0.79
-35 (-31) 675 170 198 207 0.97 2.23 3.26 0.82 0.95
-30 (-22) 906 228 266 233 1.08 3.00 3.88 0.98 1.14
-25 (-13) 1181 298 346 258 1.20 3.93 4.56 1.15 1.34
-20 (- 4) 1501 378 440 284 1.32 5.01 5.27 1.33 1.55
-15 (+ 5) 1864 470 546 310 1.43 6.25 6.01 1.52 1.76
-10 (+14) 2272 573 666 336 1.55 7.65 6.77 1.71 1.98
UPDATE: 28OCT2021 860BX71
COMPRESSOR TECHNICAL DATA
E - PERFORMANCE - CURVES
TEST CONDITIONS: EN12900HH (Condensing temperature 55ºC (+131ºF) )
@220V3600RPM Fan
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-40 (-40) 385 97 113 180 0.85 1.40 2.14 0.54 0.63
-35 (-31) 539 136 158 208 0.97 1.97 2.59 0.65 0.76
-30 (-22) 733 185 215 238 1.10 2.69 3.09 0.78 0.91
-25 (-13) 968 244 284 268 1.24 3.56 3.62 0.91 1.06
-20 (- 4) 1243 313 364 299 1.38 4.59 4.16 1.05 1.22
-15 (+ 5) 1559 393 457 331 1.52 5.79 4.71 1.19 1.38
-10 (+14) 1916 483 562 364 1.67 7.15 5.26 1.33 1.54
TEST CONDITIONS: EN12900HH (Condensing temperature 35ºC (+95ºF) )
@220V4500RPM Fan
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-40 (-40) 759 191 222 229 1.07 2.29 3.31 0.83 0.97
-35 (-31) 1010 254 296 258 1.21 3.06 3.92 0.99 1.15
-30 (-22) 1321 333 387 287 1.34 4.01 4.61 1.16 1.35
-25 (-13) 1692 426 496 314 1.46 5.15 5.38 1.36 1.58
-20 (- 4) 2124 535 622 341 1.58 6.49 6.23 1.57 1.82
-15 (+ 5) 2617 659 767 366 1.69 8.03 7.14 1.80 2.09
-10 (+14) 3170 799 929 390 1.80 9.77 8.13 2.05 2.38
TEST CONDITIONS: EN12900HH (Condensing temperature 45ºC (+113ºF) )
@220V4500RPM Fan
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-40 (-40) 594 150 174 227 1.06 1.96 2.61 0.66 0.77
-35 (-31) 833 210 244 264 1.22 2.75 3.16 0.80 0.93
-30 (-22) 1123 283 329 299 1.38 3.72 3.75 0.94 1.10
-25 (-13) 1463 369 429 334 1.54 4.86 4.38 1.10 1.28
-20 (- 4) 1853 467 543 367 1.68 6.19 5.05 1.27 1.48
-15 (+ 5) 2295 578 672 398 1.83 7.69 5.76 1.45 1.69
-10 (+14) 2787 702 817 429 1.96 9.38 6.51 1.64 1.91
UPDATE: 28OCT2021 860BX71
COMPRESSOR TECHNICAL DATA
E - PERFORMANCE - CURVES
TEST CONDITIONS: EN12900HH (Condensing temperature 55ºC (+131ºF) )
@220V4500RPM Fan
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-40 (-40) 422 106 124 213 1.00 1.54 1.99 0.50 0.58
-35 (-31) 649 163 190 259 1.21 2.37 2.50 0.63 0.73
-30 (-22) 916 231 268 304 1.41 3.36 3.01 0.76 0.88
-25 (-13) 1224 308 359 347 1.61 4.50 3.53 0.89 1.04
-20 (- 4) 1573 396 461 388 1.79 5.81 4.06 1.02 1.19
-15 (+ 5) 1962 494 575 428 1.97 7.28 4.59 1.16 1.35
-10 (+14) 2393 603 701 466 2.14 8.93 5.12 1.29 1.50
UPDATE: 28OCT2021 860BX71
COMPRESSOR TECHNICAL DATA
F - EXTERNAL CHARACTERISTICS
1 Base plate Universal
2 Tray holder No
3 Connectors
3.1 SUCTION 8.1 +0.10/+0.00 [mm] (0.319" +0.004"/+0.000")
3.1.1 Material Copper
3.1.2 Shape Slanted 42°
3.2 DISCHARGE 6.45 +0.10/+0.00 [mm] (0.254" +0.004"/+0.000")
3.2.1 Material Copper
3.2.2 Shape Slanted parallel to Base Plate
3.3 PROCESS 6.45 +0.10/+0.00 [mm] (0.254" +0.004"/+0.000")
3.3.1 Material Copper
3.3.2 Shape Slanted 42°
3.4 Oil cooler (Copper) No [mm]
3.5 Connector sealing Rubber Plugs
UPDATE: 28OCT2021 860BX71