DuoLine.

The Duo of Power


and Intelligence.
NEW! Tested for
wet areas.
DuoLine

DuoLine – Intelligent
combinations for
more power and intelligence.

More component technology More function

The used materials are selected in such way that the res- Different functional principles were combined in one product in a way
pective functional requirements are optimal supported. that the most suitable function for the building material activates itself
always automatically.

More benefits
More colourful
From the innovative combination of materials and fun-
ctions, there are always new and additional application The colour combination red-grey highlights the functionally optimized
possibilities compared to conventional solutions. design and creates a high recognition value.

More ease of installation More performance

The installation occurs always in an easy way, without any The clever combination of materials and functions leads to more hol-
special tools and saves therefore time and costs. ding force and therefore also to more safety.

» Cleverly combined, very well rewarded «


Due to its convincing innovative performance in regards
to design and expertise in plastic technology,
DuoPower has already received numerous awards.


BEST OF

3
DuoLine

» Simply clever, the combi-


nation of two components
guarantees even better
performance. «

4
DuoLine

DuoPower
The plug with superior performance in a wide variety of building materials.

· Two component materials in red and grey for even · A plug for numerous applications with top load values
more expansion volume and an optimally coordinated in a wide variety of building materials.
screw-in and tightening torque. · European Technical Assessment (ETA) for certain
· Expands in solid building materials, folds in hollow DuoPower dimensions for maximum safety in concrete
building materials and knots in panel building materi- and masonry (see load table).
als. · Due to the compact and short shape, it needs signifi-
· Automatically adapts itself to the requirements of the cantly less drilling effort and shorter screws can be
respective building material and therefore is extremely used.
versatile to use.

Intelligent self-activating functions depending on the base material.

Certificates

CE
ETA-22/0512, for multiple
non-structural systems in
concrete and masonry

The long versions for even more bite in problematic building materials.

· Two component materials in red and grey for even · Automatically adapts itself to the requirements of each
more expansion volume and an optimally coordi- building material. Ensures excellent holding thanks to
nated screw-in and tightening torque despite deeper its longer anchorage depth.
anchorage. · A plug for numerous applications with high load ca-
· Three plug zones: Tip, shaft and base with differently pacity in problematic building materials, e. g. perforat-
arranged expansion and folding functions for more ed building materials, aerated concrete or for plaster
bite and higher pull-out values. bridging.

Long versions with additional bite in problematic building materials.

Certificates

5
DuoLine

» Anchoring with a smart


bite, thanks to innovative
combination of material
and design.«

6
DuoLine

DuoXpand
Clever combination of material and design.

· The special lamella geometry expands gently in the respective building material. This
avoids fractures in porous building materials and enables anchoring close to the edge.
· The European Technical Assessment (ETA) for multiple use for non-structural applications
ensures secure hold in all building material classes.
· The DuoXpand is suitable for push-through installation.
· In perforated bricks, the lamellas expand at the stone web and form an undercut in the
cavity. The anchor geometry ensures that the force is transferred evenly to the material, so
that porous stone webs are not destroyed.
· The version with countersunk screw is particularly suitable for fastening timber to concrete
and masonry. For fixing metal, the version with a wide sleeve rim and a hexagon head
screw with moulded washer is recommended.

Application in solid material Application in perforated material

Certificates

CE

ETA-21/0324, for redundant


non-structural systems in
concrete and masonry

7
DuoLine

» Intelligent combination
for high loads in all panel
building materials. «

8
DuoLine

fischer DuoTec 10
Solves difficult installation tasks in drywall building materials.

· Two component toggle element in red and grey · Suitable for screws and hooks with different
(hard/soft) and flange sleeve made of glass thread types due to its flexible screw insert.
fibre-reinforced plastics ensure high tensile and · Simple installation with the aid of a standard
transverse loads. diameter 10 mm drill bit.
· Folds in cavities behind panel building materials, · A cavity toggle with high load bearing capability
even in ones insulated with mineral wool. Ex- in dry wall materials, especially in gypsum plas-
pands in solid building materials such as wood terboard and gypsum fibreboard.
or concrete.

Ideal toggle plug for drywall building panels, or also as expansion plug in solid materials.

fischer DuoTec 12
Extra strong for all panel building materials.

·  The two component toggle element in red and · Suitable for screws and hooks with different
grey (hard/soft) and flange sleeve made of glass thread types due to its flexible screw insert.
fibre-reinforced plastics ensure high tensile and · Simple installation with the aid of a standard
transverse loads. diameter 12 mm drill bit.
· Extra strong because of its metal skeleton insert. · A cavity toggle with high load bearing capability
· Folds in cavities behind panel building materials, in all panel building materials but also hollow
even in ones insulated with mineral wool, or blocks made of lightweight concrete.
hollow concrete blocks. Expands in solid building
materials such as wood or concrete.

Strong toggle plug for all board materials able to handle high loads.

9
DuoLine

DuoBlade
The self-drilling plasterboard plug for fast and easy installation.

· The self-drilling fischer DuoBlade allows fast and · The black metal tip guarantees simple and safe
easy installation in gypsum plasterboard and installation.
gypsum fibreboard. · The fischer DuoBlade is adapted for wood, metal
· PZ2 drive – same drive for plug and screw. and chipboard screws from 4 to 5 mm thickness
· High torque when anchor is installed for the as well as different hooks like the EasyHook.
feelgood-factor and an optimum feeling when · In gypsum fibreboard, pre-drilling with
setting. a drill ø 8mm is recommended.

Fixing in plasterboard.

10
DuoLine

DuoSeal
The sealing plug for wet areas.

· The DuoSeal completely seals drill holes in tiles · Its red component ensures a secure hold in all
without additional sealing compound and thus building materials. Thus, the DuoSeal achieves
prevents structural damage caused by moisture the same load values as conventional nylon
in the building material. plugs.
· The DuoSeal is ideally suited for tiled surfaces · The stainless steel screw included in the set is
which are exposed to very frequent splash water ideally suited for installations in wet areas and
and temporarily accumulated water. In any case, avoids rusting.
please take note of the general national regula- · The soft plastic rim closes the drill hole com-
tions on the use of plugs in wet areas. pletely and flexibly adapts to the shape of the
· The universal plug can be installed gently on tiles attachment part.
with very little effort.

Excellent for many building materials with tiled surfaces.

11
DuoLine

Recommendations
DuoPower building material recommendation DuoPower material properties

CE
ETA-22/0512, for multiple
non-structural systems in
concrete and masonry1)

Suitable for concrete, solid brick, solid sand-lime brick, vertical- Two component injection moulding for
ly perforated brick, cavity floor slabs made of brick, perforated thermal combining of hard and soft plastic.
sand-lime brick, hollow block made of lightweight concrete, 1) DuoPower ETA 8x40 with safety screw and FPF II are
aerated concrete, natural stone, gypsum plasterboard and approved for concrete. DuoPower ETA 10x50 with safety
screw is approved for concrete, solid brick, solid sand-lime
gypsum fibreboard, solid gypsum panels, chipboard. brick and vertically perforated brick.

DuoXpand material recommendation DuoXpand material properties

CE
ETA-21/0324, for redundant
non-structural systems in
concrete and masonry

Suitable for concrete, solid sand-lime brick, solid brick, vertically


perforated brick, perforated sand-lime brick, hollow block solid
brick made from lightweight concrete, aerated concrete.

fischer DuoTec building material recommendation fischer DuoTec material properties

The plastics of all components are extra


glass-fibre reinforced.

Suitable for all panel building materials, for example: gypsum


plasterboard, gypsum fibreboard, OSB boards, chipboard,
MDF sheets, plywood boards, steel panels, plastic boards, etc.
Also functioning in solid materials, such as concrete and wood.

12
DuoLine

DuoBlade building material recommendation DuoBlade material properties

Suitable for panel building materials e.g. gypsum


plasterboard, gypsum fibreboard and lightweight
cement boards.

The plastics of all components are extra


glass-fibre reinforced.

DuoSeal building material recommendation DuoSeal material properties

isch beanspr
em uc
ch h
d

te
n
hu
SFV

Wa
physikalisc

nd u
nd Boden
Säurefliesner-Vereinigung
e.V.

für
Großburgwedel

be
ut
tit
ge


s
In

Suitable for use in tiles or in tile joints on a wide variety of Independently tested and confirmed in
substrates, such as concrete, masonry, vertically per- accordance with ETAG 022 and DIN 18534
forated brick, plasterboard, gypsum planks, lightweight up to the water exposure class W3-I.
concrete (hollow block), lightweight concrete (solid block)
and aerated concrete.

13
DuoLine

Applications
DuoPower

Consoles Pipe fastenings Radiators

DuoXpand

Timber substructures Wood Carports Facade substructures Metal

fischer DuoTec

Light wall shelves Mirrors Lamps

14
DuoLine

DuoBlade

Smoke detectors Mirrors Curtain rods

DuoSeal · Tiled surfaces with frequent exposure to water

Furnishing of bathrooms Wall fixings in garages Accessories inside the shower

15
DuoLine

Assortment lS ≥ hef + tfix+ ds

d0 dS

l = hef tfix
h1

DuoPower

DuoPower DuoPower long

Without With Drill hole Min. Min. Min. bolt Anchor Screws Drive Max. fixture Sales
screw screw diameter drill hole panel thick- penetration length thickness unit
depth ness
d0 h1 dp lE,min l ds / ds x ls t fix
Item Item No. Item No. [mm] [mm] [mm] [mm] [mm] [mm] [mm] [pcs]
DuoPower 5 x 25 555005 – 5 35 12,5 29 25 3–4 – – 100
DuoPower 6 x 30 555006 – 6 40 12,5 35 30 4–5 – – 100
DuoPower 6 x 50 538240 – 6 60 12,5 55 50 4–5 – – 100
DuoPower 8 x 40 555008 – 8 50 12,5 46 40 4,5 – 6 – – 100
DuoPower 8 x 65 538241 – 8 75 2x 12,5 71 65 4,5 – 6 – – 50
DuoPower 10 x 50 555010 – 10 70 12,5 58 50 6–8 – – 50
DuoPower 10 x 80 538242 – 10 100 – 88 80 6–8 – – 25
DuoPower 12 x 60 538243 – 12 80 – 70 60 8 – 10 – – 25
DuoPower 14 x 70 538244 – 14 90 – 82 70 10 – 12 – – 20
DuoPower 5 x 25 S – 555105 5 40 12,5 29 25 3,5 x 35 PZ2 6 50
DuoPower 6 x 30 S – 555106 6 45 12,5 35 30 4,5 x 40 PZ2 5 50
DuoPower 6 x 30 S PH TX – 545838 1) 6 45 12,5 35 30 4,5 x 40 TX 20 5 100
DuoPower 6 x 50 S – 538245 6 65 12,5 55 50 4,5 x 60 PZ2 15 50
DuoPower 8 x 40 S – 555108 8 65 12,5 45 40 5,0 x 55 PZ2 10 50
DuoPower 8 x 65 S – 538246 8 85 2x 12,5 70 65 5,0 x 80 PZ2 10 25
DuoPower 10 x 50 S – 555110 10 74 12,5 57 50 7,0 x 69 SW 13/TX 40 12 25
DuoPower 10 x 80 S – 538247 10 112 – 87 80 7,0 x 107 SW 13 20 10
DuoPower 12 x 60 S – 538248 12 85 – 68 60 8,0 x 80 SW 13 12 10
DuoPower 14 x 70 S – 538249 14 100 – 80 70 10,0 x 95 SW 17 15 8
1) DuoPower S PH TX with chipboard screw panhead

lS ≥ hef + tfix+ ds lS ≥ hef + tfix+ ds

dS

d0 dS d0

l = hef tfix l = hef tfix


h1 h1

DuoPower ETA

DuoPower FPF II DuoPower Safety screw

Approval Drill hole Min. Min. bolt Anchor Screw Drive Max. fixture Sales
diameter drill hole penetration length thickness 2) unit
depth 1)
d0 h1 lE,min l ds / ds x ls t fix
Item Item No. ETA [mm] [mm] [mm] [mm] [mm] [mm] [pcs]
DuoPower ETA 8 x 40 FPF II 3) 564789 ● 8 69 46 40 6,0 x 60 TX 30 14 50
DuoPower ETA 8 x 40 Safety screw 564790 ● 8 76 46 40 6,0 x 66,5 SW 10/TX 30 20 50
DuoPower ETA 10 x 50 Safety screw 564792 ● 10 78 57 50 7,0 x 69 SW 13/TX 40 12 50
1) Min.drill hole depth h1 [mm] = ls - tfix + 10
2) Max. fixture thickness t
fix [mm] = ls - l - ds
3) Power Fast II screw

16
DuoLine

Loads DuoPower
DuoPower
Highest recommended loads1) for a single anchor. The given loads are valid for wood screws with the specified diameter.
Type 5 x 25 6 x 30 6 x 50 8 x 40 8 x 65 10 x 50 10 x 80 12 x 60 14 x 70
Wood screw diameter [mm] 4 5 5 6 6 8 8 10 12
Min. edge distance concrete cmin [mm] 30 35 35 50 50 65 65 80 100
Recommended loads in the respective base material Frec2)
Concrete ≥ C20/25 [kN] 0.40 0.95 1.65 1.10 2.30 2.15 4.20 3.30 5.30
Solid brick ≥ Mz 12 [kN] 0.30 0.50 0.55 0.62 0.69 1.20 1.45 1.30 1.35
Solid sand-lime brick ≥ KS 12 [kN] 0.50 1.00 1.60 1.25 2.25 2.20 3.85 2.80 4.50
Aerated concrete ≥ AAC 2 (G2) [kN] 0.05 0.10 0.15 0.10 0.16 0.20 0.30 0.24 0.35
Aerated concrete ≥ AAC 4 (G4) [kN] 0.25 0.38 0.55 0.42 0.60 0.60 1.10 1.00 1.45
Vertically perforated brick ≥ Hlz 12 (ρ ≥ 0.9 kg/dm³) [kN] 0.13 0.15 0.17 0.25 0.40 0.25 0.40 0.35 0.40
Perforated sand-lime brick ≥ KSL 12 (ρ ≥ 1.6 kg/dm³) [kN] 0.40 0.60 0.60 0.70 1.00 0.70 2.00 0.75 1.50
Gypsum block (ρ ≥ 0,9 kg/dm³) [kN] 0.10 0.18 0.37 0.25 0.50 0.35 0.65 0.50 0.50
Gypsum fibreboard 12.5 mm [kN] 0.24 0.33 0.35 0.35 - 0.50 - - -
Gypsum plasterboard 12.5 mm [kN] 0.12 0.15 0.15 0.15 - 0.15 - - -
Gypsum plasterboard 2 x 12.5 mm [kN] 0.13 0.15 0.24 0.20 0.32 0.30 - - -
Mattone Forato Typ F8 [kN] 0.30 0.30 - 0.25 - 0.25 - - -
Tramezza Doppio UNI 19 [kN] 0.15 0.15 0.23 0.15 0.30 0.20 0.52 0.35 0.35
Sepa Parpaing [kN] 0.30 0.45 0.25 3) 0.45 0.453) 0.45 0.453) 0.603) 0.603)
1) Required safety factors are considered.
2) Valid for tensile load, shear load and oblique load under any angle.
3) Load determination on plastered wall.

Universal plug DuoPower


Permissible loads1)2)3) of a single anchor as part of a multiple fixing of non-structural systems.
For the design the complete current assessment ETA-22/0512 of 04.11.2022 has to be considered.

Type DuoPower ETA 8x40 DuoPower ETA 8x40 DuoPower ETA 10x50
Power Fast II special screw special screw

Anchor diameter d0 [mm] 8 8 10


Screw diameter d [mm] 6 6 7
Anchorage depth hnom [mm] 40 40 50
Anchorage in concrete ≥ C16/204)
Permissible tensile load Nperm [kN] 0.12 0.79 0.79
Permissible shear load Vperm zinc coated screws (gvz) [kN] 3.10 4.23 5.98
stainless steel screw (R) [kN] - 3.93 5.98
Minimum member thickness hmin [mm] 150 150 150
Characteristic edge distance ccr,N [mm] 55 90 80
Characteristic spacing a resp. scr,N [mm] 15 50 50
Minimum spacing smin [mm] 50 50 50
with an edge distance c≥ [mm] 100 100 100
Minimum edge distance cmin [mm] 50 80 80
with a spacing s≥ [mm] 100 160 160
Anchorage in masonry
Permisible load5) Fperm in solid brick ≥ Mz 10/2; NF [kN] – – 0.40 –
≥ Mz 16/2; NF [kN] – – 0.57 –
≥ Mz 20/2; NF [kN] – – 0.71 –
Permissible load5) Fperm in solid sand-lime brick ≥ KS 8/2; 2DF [kN] – – 0.60 0.706)
≥ KS 12/2; 2DF [kN] – – 0.60 0.706)
Permissible load5) Fperm in perforated clay brick ≥ Hlz 10/1.2; 9 DF [kN] – – 0.17
≥ Hlz 12/1.2; 9 DF [kN] – – 0.21
Minimum member thickness hmin [mm] – – 115
Minimum spacing (single anchor) amin [mm] – – 250
Minimum spacing (anchor group) smin [mm] – – 50
Minimum edge distance (anchor group) cmin [mm] – – 80
1) Validfor zinc coated (gvz) Power Fast II and special screw and as well as for special screw made of stainless steel (R). For exterior use of the zinc coated screws measures against incoming
humidity have to be taken.
2) The required partial safety factors for material resistance as well as a partial safety factor for load actions γ = 1.4 are considered. As a single anchor counts e.g. an anchor with a minimum
L
spacing a according to Annex B 2 or B 3 of the assessment.
3) Valid for temperatures in the substrate up to +24 °C (resp. short term up to +40 °C).
4) For values in concrete C12/15 see assessment.
5) Valid for tensile load, shear load and oblique load under any angle. For combinations of tensile loads, shear loads and bending moments see assessment. Bulk density of stone in [kg/dm3]

and minimum compressive strength in [N/mm2] according to EN 771.


6) Only valid for c
1min 110 mm and c2min 165 mm.

17
DuoLine

Assortment d0

hnom tfix
l
h2

DuoXpand-T – with fischer countersunk head safety screw

DuoXpand T
Item Item No. Item No. Approval Drill hole Min. drill hole depth Usable length at anchorage depth Anchor Drive Sales unit
diameter for through fixings length

Description Zinc-plated Stain- d0 h2 tfix l


steel less
steel
hnom = hnom = hnom = hnom =
gvz R ETA [mm] [mm] 50 mm 70 mm 140 mm 160 mm [mm] [pcs]
DuoXpand 8x80 T 562149 – ● 8 90 30 10 – – 80 T30 50
DuoXpand 8x100 T 562150 – ● 8 110 50 30 – – 100 T30 50
DuoXpand 8x120 T 562151 – ● 8 130 70 50 – – 120 T30 50
DuoXpand 10x80 T 562155 562163 ● 10 90 30 10 – – 80 T40 50
DuoXpand 10x100 T 562156 562164 ● 10 110 50 30 – – 100 T40 50
DuoXpand 10x120 T 562157 562165 ● 10 130 70 50 – – 120 T40 50
DuoXpand 10x140 T 562158 562166 ● 10 150 90 70 – – 140 T40 50
DuoXpand 10x160 T 562159 – ● 10 170 110 90 20 – 160 T40 50
DuoXpand 10x180 T 562160 – ● 10 190 130 110 40 20 180 T40 50
DuoXpand 10x200 T 562161 – ● 10 210 150 130 60 40 200 T40 50
DuoXpand 10x230 T 562162 – ● 10 240 180 160 90 70 230 T40 50

d0

hnom tfix
l
h2

DuoXpand-FUS – with fischer hexagon head safety screw with moulded washer and integrated bit recess

Item Item No. Item No. Approval Drill hole Min. drill hole depth Usable length at anchorage depth Anchor Drive Sales unit
diameter for through fixings length

Description Zinc- Stain- d0 h2 tfix l


plated less
steel steel
hnom = hnom = hnom = hnom =
gvz R ETA [mm] [mm] 50 mm 70 mm 140 mm 160 mm [mm] [pcs]
DuoXpand 8x80 FUS 562152 – ● 8 90 30 10 – – 80 T30/SW10 50
DuoXpand 8x100 FUS 562153 – ● 8 110 50 30 – – 100 T30/SW10 50
DuoXpand 8x120 FUS 562154 – ● 8 130 70 50 – – 120 T30/SW10 50
DuoXpand 10x80 FUS 562167 562175 ● 10 90 30 10 – – 80 T40/SW13 50
DuoXpand 10x100 FUS 562168 562176 ● 10 110 50 30 – – 100 T40/SW13 50
DuoXpand 10x120 FUS 562169 562177 ● 10 130 70 50 – – 120 T40/SW13 50
DuoXpand 10x140 FUS 562170 562178 ● 10 150 90 70 – – 140 T40/SW13 50
DuoXpand 10x160 FUS 562171 – ● 10 170 110 90 20 – 160 T40/SW13 50
DuoXpand 10x180 FUS 562172 – ● 10 190 130 110 40 20 180 T40/SW13 50
DuoXpand 10x200 FUS 562173 – ● 10 210 150 130 60 40 200 T40/SW13 50
DuoXpand 10x230 FUS 562174 – ● 10 240 180 160 90 70 230 T40/SW13 50

18
DuoLine

Loads DuoXpand
Frame fixing DuoXpand

Permissible loads1)2)3) of a single anchor as part of a multiple fixing of non-structural systems.


For the design the complete current assessment ETA-21/0324 has to be considered.

Type DuoXpand 8 DuoXpand 10

Anchor diameter d [mm]


Anchorage in concrete ≥ C16/204)
Anchorage depth hnom ≥ [mm] 50 70 50 70 – –
Permissible tensile load Nperm [kN] 1.39 1.59 1.59 1.79 – –
Permissible shear load Vperm zinc coated screws (gvz) [kN] 4.23 4.23 5.98 5.98 – –
stainless steel screw (R) [kN] 3.93 3.93 5.98 5.98 – –
Minimum member thickness hmin [mm] 80 100 80 100 – –
Characteristic edge distance ccr,N [mm] 50 50 50 50 – –
Characteristic spacing a resp. scr,N [mm] 65 70 70 80 – –
Minimum spacing smin [mm] 50 50 50 50 – –
with an edge distance c≥ [mm] 100 100 100 100 – –
Minimum edge distance cmin [mm] 50 50 50 50 – –
with a spacing s≥ [mm] 100 100 100 100 – –
Anchorage in masonry5)6)
Anchorage depth hnom [mm] 50 70 50 70 140 160
Permisible load Fperm in solid brick Mz, ≥ NF; ≥ 10 [N/mm2] / ρ ≥ 1.8 [kg/dm3] [kN] 0.43 0.43 0.26 0.26 – –
e.g. Ziegelwerk Nordhausen ≥ NF; ≥ 20 [N/mm2] / ρ ≥ 1.8 [kg/dm3] [kN] 0.86 1.00 0.57 0.57 – –
Permissible load Fperm in solid sand-lime brick ≥ NF; ≥ 10 [N/mm2] / ρ ≥ 2.0 [kg/dm3] [kN] 0.43 0.57 0.57 0.57 – –
KS,
e.g. Wemding ≥ NF; ≥ 20 [N/mm2] / ρ ≥ 2.0 [kg/dm3] [kN] 1.00 1.14 1.14 1.14 – –
Permissible load7) Fperm in lightweight concrete ≥ 2 DF; ≥ 2 [N/mm2] / ρ ≥ 1.4 [kg/dm3] [kN] 0.11 0.17 0.09 0.17 – –
block Vbl, e.g. KLB ≥ 2 DF; ≥ 4 [N/mm2] / ρ ≥ 1.4 [kg/dm3] [kN] 0.21 0.34 0.17 0.34 – –
Permissible load7) Fperm in vertically perforated 3 DF; ≥ 10 [N/mm2] / ρ ≥ 0.9 [kg/dm3] [kN] 0.21 0.34 0.21 0.34 – –
brick HLz, e.g. Schlagmann 3 DF; ≥ 12 [N/mm2] / ρ ≥ 0.9 [kg/dm3] [kN] 0.26 0.43 0.26 0.43 – –
Permissible load Fperm in perforated sand-lime 3 DF; ≥ 8 [N/mm2] / ρ ≥ 1.4 [kg/dm3] [kN] 0.26 0.21 0.17 0.26 – –
brick KSL, e.g. Wemding 3 DF; ≥ 16 [N/mm2] / ρ ≥ 1.4 [kg/dm3] [kN] 0.43 0.43 0.34 0.57 – –
Permissible load7) Fperm in hollow lightweight 16 DF; ≥ 2 [N/mm2] / ρ ≥ 0.7 [kg/dm3] [kN] 0.14 0.14 0.21 0.21 – –
concrete blocks Hbl, e.g Knobel, DE 16 DF; ≥ 4 [N/mm2] / ρ ≥ 0.7 [kg/dm3] [kN] 0.26 0.26 0.43 0.43 – –
Permissible load7) Fperm in hollow lightweight ≥ 2 [N/mm2] / ρ ≥ 1.0 [kg/dm3] [kN] 0.09 – 0.14 0.14 – 0.09
concrete blocks Hbl, eg. Sepa Parpaing, FR ≥ 4 [N/mm2] / ρ ≥ 1.0 [kg/dm3] [kN] 0.21 0.14 0.26 0.26 0.14 0.14
Minimum member thickness hmin [mm] 115 115 115 115 200 200
Minimum spacing (single anchor) amin [mm] 250 250 250 250 250 250
Minimum spacing (anchor group) smin [mm] 100 100 100 100 100 100
Minimum edge distance (anchor group) cmin [mm] 100 100 100 100 100 100
Anchorage in aerated concrete6)
Anchorage depth hnom ≥ [mm] 70 – 70 – – –
Permissible load Fperm in aerated concrete, AAC 2 [kN] 0.11 – 0.14 – – –
acc.to EN 771-4:2011+A1:2015 AAC 4 [kN] 0.27 – 0.21 – – –
AAC 6 [kN] 0.54 – 0.32 – – –
Permissible load Fperm in reinforced aerated AAC 4; fck ≥ 4 N/mm2 [kN] – – 0.18 – – –
concrete, acc. to EN 12602:2016 AAC 6; fck ≥ 6 N/mm2 [kN] – – 0.32 – – –
Minimum member thickness hmin [mm] 100 / 1758) – 100 / 1758) – – –
Minimum spacing (single anchor) amin [mm] 250 – 250 – – –
Minimum spacing (anchor group) smin [mm] 100 / 808) – 100 / 808) – – –
Minimum edge distance (anchor group) cmin [mm] 100 – 100 – – –
1) Validfor zinc coated screws (gvz) and for screws made of stainless steel (R). For exterior use of the zinc coated screws measures against incoming humidity according to assessment have to
be taken.
2) The required partial safety factors for material resistance as well as a partial safety factor for load actions γ = 1.4 are considered.
L
As a single anchor counts e.g. an anchor with a minimum spacing a according to the ETA.
3) Valid for temperatures in the substrate up to +50 °C (resp. short term up to +80 °C). For long term temperatures up to +30 °C higher permissible loads may be possible.
4) For concrete specifications in C12/15, see ETA.
5) Stone property data in min. compressive strength [N/mm2] and bulk density [kg/dm3]. Corresponding mean compressive strengths according to EN 771 and other brick variants or brick

geometries are listed in the ETA.


6) Load data are valid for tensile load, shear load and oblique load under any angle. For bending moments and invisible or not mortar-filled joints the design specifications of the ETA must be

observed.
7) Rotary drilling method.
8) Only valid for groups of anchors in AAC with compression strength ≥ 6 N/mm².

19
DuoLine

Assortment dS
d0

a dp tfix
lS

fischer DuoTec in gypsum board wall

fischer DuoTec 10 fischer DuoTec 12


Drill hole Min. Max. Min. Screw Screw Sales unit
diameter panel thickness panel thickness cavity depth diameter length
d0 dp dp a ds ls
Item Item no. [mm] [mm] [mm] [mm] [mm] [mm] [Stück]
fischer DuoTec 10 S 537259 1) 10 12 55 40 5.0 60 25
fischer DuoTec 10 537258 10 12 55 40 4.5 – 5 ≥ dp + tfix +20 50
fischer DuoTec 10 S PH 539025 2) 10 12 55 40 5.0 60 25
fischer DuoTec 12 542796 12 12 55 50 5 – 6/M6 ≥ dp + tfix +20 10
fischer DuoTec 12 RH 542798 4) 12 12 55 50 5.5 70 10
fischer DuoTec 12 S PH M 542797 3) 12 12 55 50 M6 70 10
1) fischerDuoTec S – with chipboard screw countersunk head
2) fischer DuoTec S PH – with chipboard screw Panhead
3) fischer DuoTec S PH M – with machine screw Panhead
4) fischer DuoTec RH – with screw with round hook

d0

dS

h1 tfix
lS

fischer DuoTec in solid brick

fischer DuoTec 10 fischer DuoTec 12


Drill hole Min. drill hole Screw diameter Min. screw Anchor length Max. fixture Sales unit
diameter depth length thickness

d0 h1 ds ls l t fix
Item Item no. [mm] [mm] [mm] [mm] [mm] [mm] [Stück]
fischer DuoTec 10 S 537259 1) 10 65 5.0 60 50 27 25
fischer DuoTec 10 537258 10 ls - tfix + 10 4.5 – 5 tfix + 55 50 ls - 55 50
fischer DuoTec 10 S PH 539025 2) 10 65 5.0 60 50 27 25
fischer DuoTec 12 542796 12 ls - tfix + 10 5–6 tfix + 65 60 ls - 65 10
fischer DuoTec 12 RH 542798 3) 12 75 5.5 55 60 – 10
1) fischerDuoTec S – with chipboard screw countersunk head
2) fischer DuoTec S PH – with chipboard screw Panhead
3) fischer DuoTec RH – with screw with round hook

20
DuoLine

Loads DuoTec
Nylon toggle DuoTec

Recommended loads1) 2) for a single anchor.


Type fischer DuoTec 10 fischer DuoTec 12

Chipboard screws Metrical screw Chipboard screws Metrical screw

Screw diameter [mm] 4.5 5.0 5.0 5.0 6.0 6.0


Recommended loads in the respective base material Frec3) for a
span in the construction b = 625 mm

Gypsum plasterboard 9.5 mm [kN] 0.17 0.17 0.17 0.17 0.17 0.17
Gypsum plasterboard 12.5 mm [kN] 0.20 0.20 0.20 0.20 0.20 0.20
Gypsum plasterboard 2x 12.5 mm [kN] 0.43 0.43 0.43 0.43 0.43 0.43
Gypsum fibreboard 12.5 mm [kN] 0.51 0.51 0.51 0.51 0.51 0.51
Chipboard 16 mm [kN] 0.71 0.71 0.71 0.75 0.80 0.80
OSB board 18 mm [kN] 0.75 0.75 0.75 0.75 1.30 1.30
Recommended loads in the respective base material Frec3) for a
span in the construction b = 120 mm

Gypsum plasterboard 9.5 mm [kN] 0.20 0.20 0.20 0.20 0.20 0.20
Gypsum plasterboard 12.5 mm [kN] 0.36 0.36 0.36 0.36 0.36 0.36
Gypsum plasterboard 2x 12.5 mm [kN] 0.59 0.59 0.59 0.70 0.80 0.80
Gypsum fibreboard 12.5 mm [kN] 0.75 0.75 0.75 0.80 1.10 1.10
Chipboard 16 mm [kN] 0.75 0.75 0.75 0.80 1.40 1.30
OSB board 18 mm [kN] 0.75 0.75 0.75 0.80 1.50 1.40
Recommended loads in solid building materials Frec3)
Concrete ≥ C20/25 [kN] 0.45 0.75 – 0.40 0.75 –
Wood [kN] 0.30 0.75 – 0.20 0.65 –
Recommended loads in the respective base material Frec3)
Hollow block of lightweight aggregate fb ≥ 8 N/mm² [kN] – – – 0.65 1.00 1.00
concrete ‚Sepa Parpaing‘
Pre-stressed hollow-core concrete slabs [kN] – – – 1.00 1.40 1.30
Lightweight concrete hollow block Hbl acc. to fb ≥ 2 N/mm² [kN] – – – 0.90 1.00 1.00
EN 771-3
1) Required safety factors are considered.
2) The recommended loads are reference values and depending to the building material and the workmanship. The values are only valid for the given screw diameter.
3) Valid for tensile load, shear load and oblique load under any angle.
4) Bending of the hook is decisive. Only for tension load.

21
DuoLine

Assortment & Loads O(PLQ


O6

KHI

Plasterboard plug DuoBlade

DuoBlade

Min. thickness Anchor length Anchor length Anchorage Min. bolt Screw Drive Sales unit
to first suppor- without drill tip depth penetration
ting layer
t l l1 hef lE,min ds/ds x ls
Item Item no. [mm] [mm] [mm] [mm] [mm] [mm] [Stück]
DuoBlade 545675 50 44 29 9.5 – 25 28 4–5 PZ2 50
DuoBlade S 545676 1) 50 44 29 9.5 – 25 28 4.5 x 40 PZ2 25
DuoBlade K NV 545683 50 44 29 9.5 – 25 28 4–5 – 10
DuoBlade S K NV 545684 1) 50 44 29 9.5 – 25 28 4.0 x 46 PZ2 6
DuoBlade RH K NV 545686 2) 50 44 29 9.5 – 25 28 4.5 x 40 – 6
DuoBlade WH K NV 545685 3) 50 44 29 9.5 – 25 28 4.2 x 40 – 6
1) DuoBlade S - with chipboard screw countersunk head.
2) DuoBlade RH - with round hook.
3) DuoBlade WH - with angled hook.

Plasterboard fixing DuoBlade


Recommended loads1) for a single anchor.
Type DuoBlade
Chipboard screw diameter [mm] 4.0–5.0
Recommended loads in the respective base material Frec2)
Gypsum plasterboard 9.5 mm [kN] 0.08
Gypsum plasterboard 12.5 mm [kN] 0.10
Gypsum plasterboard (e.g. Knauf Diamant board or Rigips Die Harte) 12.5 mm [kN] 0.18
Gypsum plasterboard 2x 12.5 mm [kN] 0.20
Lightweight cement board 12.5 mm [kN] 0.08
Gypsum fibreboard 12.5 mm [kN] 0.34
1) Required safety factors are considered. The given loads are valid for chipboard screws with the specified diameters.
2) Valid for tensile load, shear load and oblique load under any angle.

22
DuoLine

lS
hmin
tV

d0 d
S

t fix
tF
h ≥ ( lS - tfix ) + ds

DuoSeal

DuoSeal

Drill- Drill hole Minimum Minimum Plug Screw Screw Drive Sealing Tile Maximum Sales
diameter diameter drill hole building length length diameter depth thick- thickness unit
tolerance depth material ness of the at-
thickness tachment

dO h1 hmin l ls ds tV tF tfix
Item Item No. [mm] [mm] [mm] [mm] [mm] [mm] [mm] [TX] [mm] [mm] [mm] [Stück]
DuoSeal 6 x 38 S A2 557727 6 6.0 – 6.40 65 - tfix 22 38 60 4.5 20 5 – 14 5 – 10 12 50
DuoSeal 8 x 48 S A2 557728 8 8.0 – 8.45 75 - tfix 25 48 70 6.0 30 5 – 14 5 – 10 16 25
DuoSeal 6 x 38 S A2 K (4) 557733 6 6.0 – 6.40 65 - tfix 22 38 60 4.5 20 5 – 14 5 – 10 12 4
DuoSeal 8 x 48 S A2 K (2) 557734 8 8.0 – 8.45 75 - tfix 25 48 70 6.0 30 5 – 14 5 – 10 16 2

DuoSeal
Recommended loads1) for a single anchor.
Type DuoSeal 6 DuoSeal 8
Diameter stainless steel wood screw [mm] 4.5 6.0
Recommended loads in the respective base material Frec 2) 3)
Concrete ≥ C20/25 [kN] 0.40 0.60
Solid brick ≥ Mz 12 [kN] 0.20 0.30
Solid sand-lime brick ≥ KS 12 [kN] 0.30 0.40
Aerated concrete ≥ PB2, PP2 [kN] 0.10 0.10
Vertically perforated brick ≥ HLZ 12 [kN] 0.20 0.30
Perforated sand-lime brick ≥ KSL 12 [kN] 0.30 0.40
Gypsum plasterboard impregnated GKBI (green) 12.5 mm [kN] 0.104) 0.105)
Gypsum plasterboard impregnated GKBI (green) 2x 12.5 mm [kN] 0.15 0.15
Gypsum plasterboard fire resistant and impregnated GKFI 12.5 mm [kN] 0.154) 0.154)
Gypsum plasterboard fire resistant and impregnated GKFI 2x 12.5 mm [kN] 0.20 0.20
Gypsum fibreboard 12.5 mm [kN] 0.204) 0.204)
Gypsum block ρ ≥ 0.85 kg/dm³ 100 mm [kN] 0.10 0.10
1) Required safety factor is considered. Load values are valid for using the supplied stainless steel wood screws with the specified diameters according to DIN 7998.
2) Valid for tensile load, shear load and oblique load under any angle.
3) alues apply to tile thickness 5 – 10 mm.
4) Values apply to tile thickness 5 – 10 mm and total tile thickness 9.5 – 14.5 mm.
5) Values apply to tile thickness 8 – 10 mm and total tile thickness 12.5 – 14.5 mm.

23
Dealer:

www.fischer-international.com

fischer stands for

XXXXXX · 03/2023 · V-MKS · Printed in Germany · Subject to technical modifications.


Fixing Systems
Automotive
fischertechnik
Consulting
Electronic Solutions

fischerwerke GmbH & Co. KG


Klaus-Fischer-Straße 1 · 72178 Waldachtal
Germany
T +49 7443 12 - 0
www.fischer-international.com · [email protected]