Floor Standing Auto-swing mode Timer selector

Type This unit uses its automatic horizontal swing louver to spread
comfortable air flow to cool every corner of the room. Its vertical
louvers are adjusted manually to match different interior spaces
Operation starts when the preset time of the ON timer elapses
and stops when the preset time of the OFF timer elapses.

The floor standing is designed to look sleek, stylish and and partition as well as to avoid direct airflow.
modern to blend into any environment. Its slim profile Powerful operation
promotes an ideal way of space saving with style and New powerful operation boosts airflow to maximum volume for a
functionality. Its high gloss finishing makes it easy for 20-minute period with highest fan speed. After this, the unit
automatically returns to its previous settings.
cleaning. With its ease of installation, it is suited to be
installed in offices, commercial shops, restaurants,
showrooms and mosque. Indoor unit ON/OFF switch
The unit can be conveniently started manually in the event the
wireless remote controller is misplaced or the wireless remote
controller batteries are not charged.
FVRN71/100/125/140FXV14 Auto horizontal swing
Manual setting of
vertical airflow louvers

User-friendly controls Easy Maintenance


The unit comes with a stylish black control panel with white LED
light for clear display. It comes with a keylock function to prevent Safety clip
setting change from unauthorised personnel. The safety clip feature allows the users to remove the washable
saranet filter with ease during maintenance. At the same time, it
OFF State ON State also acts as a safety feature to prevent the users from reaching
White display lights up to
indicate modes and temperature
into the electrical and mechanical components.
settings when switched on

Keylock icon displayed


when activated

Keylock Function: Safety clip


Activation and deactivation of
keylock by pressing “SWING”
and “TURBO” together for
5 seconds

Wired Controller: Wireless Controller: Additionally, this unit is incorporated with


BRC51A62 BRC52A62 Far air flow infrared sensor for usage with wireless
* Optional * Supplied with unit The Daikin floor standing is able to achieve air flow distance as far as controller (BRC52A62) which comes with Space for water drain pump
25m* which is about the size of a basketball court. the unit as the standard package. Thus, it There is a space in the unit below the fan that allows users to
can also be controlled using wireless install an external condensate water pump.
* The condensate water drain pump is separately purchased and field installed.
V_r (m/s)
controller for the flexibility in controls.
Global
2.44

1.22

0.00

25m Two selectable temperature sensors


* Note: Based on size 140
Both indoor unit and wired remote controller (option) contain
temperature-sensors. Temperature sensing can be set at the unit
or, to further improve comfort level, closer to the target area at
COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES the wired remote control. This feature must be set during
commissioning by the technicians.
Network Interface Module (NIM)
Two selectable temperature

Pre-charged for up to 7.5m

External command control


Weekly scheduled timer

Washable saranet filter


Switchable fan speed

* Temperature-sensor on indoor unit must be used when the air conditioner is controlled
using G-way or BAG
Auto random restart
Programme “Dry”

Group control by

from another room.


Timer selector

Self diagnosis
Auto swing

** Wireless remote controller does not have a temperature-sensor


sensor

Switchable fan speed:


High ➡ Medium ➡ Low
*1 *1 Piping Condensate
High setting provides maximum reach while low setting minimizes Floor Standing Unit water
*1 Applicable when wired controller is used. drain pump
drafts.

07 08
Outdoor Unit Controllers
Wireless controller BRC52A62

1 “Glow-in-the-dark” ON/OFF switch 6 Vertical auto-swing


1 2 Fan speed selection: 7 Selectable mode: Cool, Dry, Fan
6
2 Low, Medium, High, Auto
7
8 Turbo function
8 3 Temperature setting: Up & down 9 Quiet function
3
RR100DXY1A4 9 4 Sleep mode function 10 On timer setting
RN50CXV1A4 RR71CXV1A4 RR125DXY1A4 4
10 5 5 Off timer setting 11 Real time clock
RN60CXV1A4 RR71CXY1A4 RR140DXY1A4
11

Fitted with wide inlet fan Equipped with scroll compressor for
Fully shaped aerodynamic propellers are designed to push air
quiet operation
with a large wing surface, providing both high blow volume and Wired controller BRC51A62
quiet operation with turbulence. Smooth running, minimal vibration, low operating sound.
* Only applicable to RR100/125/140DXY1A4
1

1 Real time clock and day display 7 Turbo function


2 2 Temperature operate in ˚C and ˚F 8 Cool, Dry, Fan mode
7 3 3 Swing function 9 Delay timer (1 or 2 hours)
RR71C RR71C 8
Outdoor RN50C RN60C
(1PH) (3PH) 9
4 4 Quiet function 10 7-days programmable timer
Sound Pressure Level dBA 52 52 56 56 10 5 5 Sleep function 11 Low, Medium, High, Auto fan speed
11 6 6 ON/OFF switch
Outdoor RR100D RR125D RR140D

Sound Pressure Level dBA 58 60 65

Wide inlet fan Wired controller BRC51A62 can directly be connected to the unit’s main board to start operating without extra setting or modification.
It also has a built-in temperature sensor that enables temperature sensing closer to target area for improved comfort (no settings required
to activate the handset temperature sensor).

Installation and Maintenance


Pre-charged for up to 7.5 metres
Model Pre-charged Max. Piping Max. Piping
Piping Length, m Length, m Elevation, m
RN50C 7.5 30 15
RN60C 7.5 30 15
RR71C(1PH) 7.5 45 25
RR71C(3PH) 7.5 45 25 IR receiver on wired handset
received the signal
RR100D 7.5 50 30
RR125D 7.5 50 30
RR140D 7.5 45 25
Signal sent from
wireless handset

Durability
• The unit is covered with corrosion-proof galvanized steel to enhance its durability.
• Heat exchange fins are provided with anti-corrosion treatment.

09 10
Auto random restart (*available on all models)
Control features
Specifications
If there is a power outage while the equipment is operating, operations will restart randomly (within 180 to 244 seconds) in the same
mode as before the power cut when electricity is restored.
Ceiling cassette
Group control by Network Interface Module (NIM) Capacity PK 2.0 2.5 3.0 3.0 4.0 5.0
You can turn up to 16 indoor units on/off with a single remote controller. (When using connected indoor units, the settings must all Indoor unit FCRN50FXV14 FCRN60FXV14 FCRN71FXV14 FCRN71FXV14 FCRN100FXV14 FCRN125FXV14
be the same and on/off will be simultaneous.) Model Outdoor unit RN50CXV1A4 RN60CXV1A4 RR71CXV1A4 RR71CXY1A4 RR100DXY1A4 RR125DXYA14
Decoration panel BC50F2XW4
External command control using G-way or BAG Nominal cooling capacity
Btu/hr 18,500 23,000 28,000 28,000 36,000 42,000
Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) kW 5.4 6.8 8.2 8.2 10.6 12.3
room. Nominal total input power W 1,760 2,050 2,930 2,900 3,660 4,110
Nominal COP W/W 3.08 3.29 2.80 2.83 2.88 3.00
Power supply V/Ph/Hz 220-240/1/50 (power from outdoor) 380-415/3/50 (power from outdoor)
Airflow (H/M/L/Q) cfm 730/620/510/360 840/700/560/440 890/760/620/490 890/760/620/491 1030/870/730/580 1120/1030/890/760
Options Sound pressure level (H/M/L/Q) dB(A) 38/35/33/29 39/37/34/31 41/38/35/32 41/38/35/33 46/41/37/34 48/45/41/37

Indoor unit
Unit mm 246x840x840 246x840x840 246x840x840 246x840x841 288x840x840 288x840x840
Dimensions
Fresh-air intake kit (HxWxD) with decoration panel mm 301x950x950 301x950x950 301x950x950 301x950x951 343x950x950 343x950x950
You can provide air-conditioning with fresh air from outside. Unit kg 22 22 22 22 25 25
Machine weight
It is convenient for places where a ventilation fan cannot be installed. decoration panel kg 5 5 5 5 5 5

Note: * Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally. Sound pressure level dB(A) 52 52 56 56 58 60
Dimensions (HxWxD) mm 651x855x328 651x855x328 753x855x328 753x855x329 852x1030x400 852x1030x400

Outdoor unit
Machine weight kg 43 47 57 56 71 95
Liquid (Flare) mm 6.35 6.35 9.52 9.52 9.52 9.52
Piping connections
Gas (Flare) mm 12.70 15.88 15.88 15.88 15.88 15.88
Max. interunit piping length m 30 30 45 45 50 50
Max. installation level difference m 15 15 25 25 30 30
1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length: 7.5m

Floor standing
Capacity PK 3.0 3.0 4.0 5.0 6.0
Indoor unit FVRN71BXV14 FVRN71BXV14 FVRN100BXV14 FVRN125BXV14 FVRN140BXV14
Model
Outdoor unit RR71CXV1A4 RR71CXY1A4 RR100DXV1A4 RR125DXY1A4 RR140DXY1A4
Btu/hr 29,000 28,000 36,000 42,000 55,000
Nominal cooling capacity
kW 8.5 8.2 10.6 12.3 16.1
Nominal total input power W 2,900 2,850 3,550 4,100 5,490
Nominal COP W/W 2.93 2.88 2.97 3.00 2.94

Power supply 220-240/1/50 380-415/3/50


V/Ph/Hz
(power from outdoor) (power from outdoor)
Airflow (H/M/L) cfm 675/625/530 675/625/530 1035/945/845 1035/945/845 1170/1085/985

Indoor unit
Sound pressure level (H/M/L) dB(A) 44/42/39 44/42/39 49/47/44 49/47/44 54/53/51
Dimensions (HxWxD) mm 1850x600x270 1850x600x270 1850x600x350 1850x600x350 1850x600x350
Machine weight kg 42 42 45 45 51
Sound pressure level dB(A) 56 56 58 60 65
Outdoor unit Dimensions (HxWxD) mm 753x855x328 753x855x328 852x1030x400 852x1030x400 852x1030x400
Machine weight kg 57 56 71 95 105
Liquid (Flare) mm 9.52 9.52 9.52 9.52 9.52
Piping connections
Gas (Flare) mm 15.88 15.88 15.88 15.88 19.05
Max. interunit piping length m 45 45 50 50 45
Max. installation level difference m 25 25 30 30 25

1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length: 7.5m

15 16