Specification sheet

Diesel
generator set
QSK60 series
engine
1600 kVA – 2500 kVA 50 Hz
1825 kW – 2250 kW 60 Hz

Description
This Cummins® commercial generator set is a Control system - The PowerCommand®
fully integrated power generation system, electronic control is standard equipment and
providing optimum performance, reliability, and provides total genset system integration
versatility for stationary Standby, Prime Power, including automatic remote starting/stopping,
and Continuous duty applications. precise frequency and voltage regulation, alarm
and status message display, AmpSentryTM
Features protection, output metering, auto-shutdown at
Cummins heavy-duty engine - Rugged 4-cycle fault detection and NFPA 110 Level 1
industrial diesel delivers reliable power, low compliance.
emissions and fast response to load changes. Cooling system - Standard integral set-
Permanent Magnet Generator (PMG) - Offers mounted radiator system, designed and tested
enhanced motor starting and fault clearing short for rated ambient temperatures, simplifies facility
circuit capability. design requirements for rejected heat.

Alternator - Several alternator sizes offer NFPA - The genset accepts full rated load in a
selectable motor starting capability with low single step in accordance with NFPA 110 for
reactance 2/3 pitch windings; low waveform Level 1 systems.
distortion with non-linear loads, fault clearing Warranty and service - Backed by a
short-circuits capability, and class F or H comprehensive warranty and worldwide
insulation. distributor network.

Standby rating Prime rating Emissions Data sheets


compliance
50 Hz 60 Hz 50 Hz 60 Hz TA Luft –
kVA (kW) kW kVA (kW) kW (kVA) EU stage
Model (kVA) 50 Hz 60 Hz
C1760 D5e 1760 (1408) 1600 (1280) 2g TA Luft DS49-CPGK

C2000 D5 2063 (1650) 1875 (1500) DS48-CPGK

C2000 D5e 2000 (1600) 1825 (1460) 2g TA Luft DS50-CPGK

C2250 D5 2250 (1800) 2000 (1600) DS52-CPGK

C2500 D5A 2500 (2000) 2250 (1800) 4g TA Luft DS53-CPGK


2000
C2000 D6 1825 (2281) DS86-CPGK
(2500)
2250
C2250 D6A DS87-CPGK
(2813)

power.cummins.com
©2019 Cummins Inc. | SS17-CPGK (QSK60HPI) (04/19)
Generator set specifications
Transient Performance ISO 8528-5 compliant
Voltage regulation, No load to full load ± 0.5%
Random voltage variation ± 0.5%
Frequency regulation Isochronous
Random frequency variation ± 0.25%
EMS compatibility BS EN61000-6-4/BS EN61000-6-2

Engine specifications
Design 4 cycle, V-black, turbocharged and low temperature after-cooled
Bore 158.8 mm (6.25 in)
Stroke 190.0 mm (7.48 in)
Displacement 60.2 L (3673 in3)
Cylinder block Cast iron, 60° V 16 cylinder
Battery capacity 2200 amps at ambient temperature 0 °F to 32 °F (0 °C)
Battery charging alternator 40 amps
Starting voltage 24 volts, negative ground
Fuel system Direct injection
Fuel filter Triple element, spin on fuel filters with water separator
Air cleaner type Dry replaceable element
Lube oil filter type(s) Four spin-on, combination full flow and bypass filters
Standard cooling system 104 ºF (40 ºC) ambient radiator

Alternator specifications
Design Brushless, 4 pole, drip-proof revolving field
Stator 2/3 pitch
Rotor Direct coupled by flexible disc
Insulation system Class H
Standard temperature rise 150 °C Standby
Exciter type Permanent Magnet Generator (PMG)
Phase rotation A (U), B (V), C (W)
Alternator cooling Direct drive centrifugal blower fan
AC waveform Total Harmonic Distortion (THDV) No load < 1.5%. Non distorting balanced linear load < 5%
Telephone Influence Factor (TIF) < 50 Per NEMA MG1-22.43
Telephone Harmonic Factor (THF) < 3%

Available voltages
50 Hz Line – Neutral/Line – Line 60 Hz Line – Neutral/Line – Line
• 220/380 • 1905/3300 • 219/380 • 2400/4160

• 230/400 • 3640/6300 • 254/440 • 7200/12470

• 240/415 • 3810/6600 • 277/480 • 7620/13200

• 254/440 • 6350/11000 • 347/600 • 7970/13800


Note: Consult factory for other voltages.

Generator set options


Engine Exhaust system (continued) Control panel (continued)
• 208/240/480 V thermo-statically • Residential grade exhaust silencer – • Masterless load demand
controlled coolant heater for ambient shipped loose • Warning high bearing temperature
above and below 4.5 ºC (40 ºF) • Side entry silencer • Alternator temperature monitoring
• Oil drain pump – manual • Exhaust gas temperature monitoring
• Engine toolkit Control panel
• 6x user-configurable relays
• Heavy duty air filter • Multiple language support • 120/240 V Heater control cabinet
• Oil Level regulator (REN Valve) • Right or left facing mounting • Mechanical hour meter
• Remote duplex filter • Floor mounted • 2x digital input/output
• 3 phase differential CTs
Exhaust system (3x or 6x CTs)
• None supplied

power.cummins.com
©2019 Cummins Power Generation Inc. | SS17-CPGK (04/19)
Generator set options (continued)
Alternator Generator set Cooling system
• 120, 240 or 110/240 V control anti- • 5 A or 10 A batteries • Remote radiator
condensation heater • Standalone or wall mountable battery • 50 ºC (122 ºF) radiator
• Stator winding temp sensor 2 charger • Slip fit connection
RTDs/phase • Manual available in multiple languages • Flanged (ASA) connection
• Bearing temp sensor RTDs • Standard spring mounts • Enhanced environmental protection for
• 1 or 2 hole lug output terminal • Oil sampling valve C2500 D5A
• Cable entrance box set mounted top or • Fuel transfer pump hand or electric
bottom entry • Free standing, single wall fuel tank
• Cable entrance box left or right mounting 1350 L/356 US Gal
• Oil make up system
Note: Some options may not be available on all models - consult factory for availability

PowerCommand 3.3 – control system • Digital power transfer control (AMF) provides load
transfer operation in open or closed transition or soft
(ramping) transfer mode
Alternator data
• Line-to-Neutral and Line-to-Line AC volts
• 3-phase AC current
• Frequency
• kW, kVar, power factor kVA (three phase and total)

Engine data
Control system • DC voltage
The PowerCommand control system is an integrated • Engine speed
microprocessor based generator set control system • Lube oil pressure and temperature
providing voltage regulation, engine protection, alternator • Coolant temperature
protection, operator interface and isochronous governing. • Comprehensive FAE data (where applicable)
AmpSentry – Includes integral AmpSentry protection,
Other data
which provides a full range of alternator protection functions
that are matched to the alternator provided. • Genset model data
• Start attempts, starts, running hours, kW hours
Power management – Control function provides battery
• Load profile (operating hours at % load in 5%
monitoring and testing features and smart starting control
increments)
system.
• Fault history
Advanced control methodology – Three phase sensing, • Data logging and fault simulation (requires InPower)
full wave rectified voltage regulation, with a PWM output for
stable operation with all load types. Standard control functions
Communications interface – Control comes standard with Digital governing (optional)
PCCNet and Modbus interface. • Integrated digital electronic isochronous governor
Regulation compliant – Prototype tested: UL, CSA and • Temperature dynamic governing
CE compliant.
Digital voltage regulation
Service - InPower™ PC-based service tool available for
• Integrated digital electronic voltage regulator
detailed diagnostics, setup, data logging and fault
• 3-phase, 4-wire Line-to-Line sensing
simulation.
• Configurable torque matching
Reliable design – The control system is designed for
reliable operation in harsh environment. AmpSentry AC protection
Multi-language support • AmpSentry protective relay
• Over current and short circuit shutdown
Operator panel features • Over current warning
Operator panel features – The operator panel, in addition • Single and three phase fault regulation
to the alternator, displays the Utility/AC Bus data. • Over and under voltage shutdown
Operator/display functions • Over and under frequency shutdown
• 320 x 240 pixels graphic LED backlight LCD • Overload warning with alarm contact
• Reverse power and reverse Var shutdown
• Auto, manual, start, stop, fault reset and lamp test/panel
• Field overload
lamp switches
• Alpha-numeric display with pushbuttons Engine protection
• LED lamps indicating genset running, remote start, not in • Battery voltage monitoring, protection and testing
auto, common shutdown, common warning, manual run • Over speed shutdown
mode, auto mode and stop • Low oil pressure warning and shutdown
• High coolant temperature warning and shutdown
Paralleling control functions
• Low coolant level warning or shutdown
• Digital frequency synchronization and voltage matching • Low coolant temperature warning
• Isochronous kW and kVar load sharing controls • Fail to start (over crank) shutdown
• Droop kW and kVar control • Fail to crank shutdown
• Cranking lockout
• Sync check
• Sensor failure indication
• Extended paralleling (Peak Shave/Base Load) • Low fuel level warning or shutdown

power.cummins.com
©2019 Cummins Inc. | SS17-CPGK (QSK60HPI) (04/19)
• Exerciser clock and time of day start/stop
Standard control functions (continued) • Data logging
Engine protection • Cycle cranking
• Fuel-in-rupture-basin warning or shutdown • Load shed
• Full authority electronic engine protection • Configurable inputs and outputs (4)
• Remote emergency stop
Control functions
• Time delay start and cool down Options
• Real time clock for fault and event time stamping • Auxiliary output relays (2)

Ratings definitions
Emergency Standby Power (ESP):
Applicable for supplying power to varying electrical
load for the duration of power interruption of a reliable
utility source. Emergency Standby Power (ESP) is in
accordance with ISO 8528. Fuel stop power in
accordance with ISO 3046, AS 2789, DIN 6271 and
BS 5514.
Limited-Time Running Power (LTP):
Applicable for supplying power to a constant electrical This outline drawing is to provide representative configuration
load for limited hours. Limited Time Running Power details for model series only.
(LTP) is in accordance with ISO 8528.
See respective model data sheet for specific model outline
Prime Power (PRP): drawing number.
Applicable for supplying power to varying electrical
load for unlimited hours. Prime Power (PRP) is in Do not use for installation design
accordance with ISO 8528. Ten percent overload
capability is available in accordance with ISO 3046,
AS 2789, DIN 6271 and BS 5514.
Base Load (Continuous) Power (COP):
Applicable for supplying power continuously to a
constant electrical load for unlimited hours.
Continuous Power (COP) in accordance with ISO
8528, ISO 3046, AS 2789, DIN 6271 and BS 5514.

Model Dim ‘A’ (mm) Dim ‘B’ (mm) Dim ‘C’ (mm) Set weight dry* (kg) Set weight wet* (kg)
C1760 D5e 6175 2494 3422 14825 16040
C2000 D5 6175 2286 2537 14880 15945
C2000 D5e 6175 2494 3422 15345 16560
C2250 D5 6175 2286 2537 15095 16160
C2500 D5A 6175 2494 3201 16840 17990
C2000 D6 6175 2286 2537 14880 15945
C2250D6A 6175 2494 3201 15380 16530
* Note: Weights represent a set with standard features. See outline drawings for weights of other configurations.

Codes and standards


This generator set is designed
All enclosed products are
in facilities certified to ISO 9001
designed to meet or exceed EU
and manufactured in facilities
certified to ISO 9001 or
2000/14/EC noise legislation 2000/14/EC
step 2006.
ISO 9002.
This generator set is available
This generator set has been
with CE certification subject to
EU RoHS exclusion per EU ISO 8528 designed to comply with
ISO 8528 regulation
2011/65.

For more information contact your local Cummins distributor


or visit power.cummins.com

©2019 Cummins Inc. All rights reserved. Cummins is a registered trademark of Cummins Inc. PowerCommand, AmpSentry, InPower and “Our energy working for you.” are trademarks of
Cummins Inc. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice.
SS17-CPGK (QSK60HPI) (04/19)

You might also like