ESSILOR INSTRUMENTS

PRODUCT CATALOGUE
Contents

Contents
INTRODUCTION – MORE THAN PRODUCTS 4. FINISHING
Contact info - local teams ................................... 4 Delta series ....................................................... 48
Intro Essilor Instruments ...................................... 5 Neksia series ..................................................... 49
ES 800 ...............................................................50
ES 700 ............................................................... 51
1. OPTOMETRY PROE 600 ......................................................... 52
ATNC 550 ............................................................9 PROE 700 ......................................................... 52
SL 650................................................................ 10 TESS ................................................................. 54
SL 550 ............................................................... 12 E-TESS .............................................................. 54
SL 450 ............................................................... 13 PROB 300 ......................................................... 54
SL 400 ............................................................... 13 ESSIBOX ........................................................... 56
Takagi 700GL slit lamp ....................................... 14
Takagi 4ZL slit lamp ............................................ 15 5. FURNITURE
Vision-S 700 ....................................................... 16
Vision-R 700 ...................................................... 17 OST 350 ............................................................ 60
Vision-R 800 ...................................................... 18 OST 250 / 250H ................................................ 61
APH 550............................................................. 19 OST 150 ............................................................ 62
MPH 150 ............................................................ 19 OST 100 ............................................................ 63
TAM 50 ............................................................. 64
AKR 800 ............................................................20
STOOLS ............................................................ 64
AKR 550 ............................................................ 21
AKR 300 ............................................................ 21
TRK-2P ..............................................................22 6. LOCAL PRODUCTS
ALM 800 ........................................................... 23
Henson 9000 .....................................................68
ALM 700 ........................................................... 24
M'Eye E.Store ................................................... 69
ALM 500 ........................................................... 24
Keeler Direct Ophthalmoscopes........................ 70
CS POLA 600 .................................................... 25
Essilor Total ....................................................... 71
CS 550 .............................................................. 26
CP 550 .............................................................. 26

2. MEASUREMENTS
Visioffice X ......................................................... 30
Visioffice 3 ......................................................... 31
WAM 800 .......................................................... 32
VR 800 / AVA .................................................... 33

3. EYE HEALTH
IDRA ................................................................. 36
Activa ................................................................ 37
Den100 .............................................................. 37
DSLC200 ........................................................... 37
E-Eye ................................................................ 38
Tearstim ............................................................ 39
Expert Myopia Care........................................... 40
OCT................................................................... 41
Retina 800 ........................................................ 42
Cornea 550 ....................................................... 43
Medmont Meridia ...............................................44
Medmont M700 .................................................45

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 3
Contact your local Essilor
Contents

Instrument department
UK, Ireland, Nordics and Benelux

BELGIUM Netherlands UK & IRELAND


Essilor Instruments Essilor Instruments Essilor Instruments
Keizer Karellaan 586 Eduard van Beinumstraat 24 Cooper Road,
Avenue Charles Quint 586 1077 CZ Amsterdam Thornbury, Bristol,
1082 St Agatha Berchem / T +31 (0) 088- 0888111 BS35 3UW
1082 Berchem-Sainte-Agathe [email protected] +44 01454 423457
T +32 (0)2 559 72 11 [email protected]
[email protected]

DENMARK FINLAND NORWAY


Essilor Instruments Essilor OY Essilor Norge
Hedegaardsvej 88 Instruments Instrumentavdelingen
2300 København S Lämmittäjänkatu 2 Dyrmyrgata 35
Tlf. 53868500 00880 Helsinki Pb. 8, 3611 Kongsberg
[email protected] tel +358 9 3480800 Tlf. 32 72 60 00
[email protected] [email protected]

SWEDEN
Essilor AB
Instrumentavdelningen
Fagerstagatan 18A
163 08 Spånga
Tel. 08-621 26 00
[email protected]

a part of

4 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
ESSILOR INSTRUMENTS

Contents
MORE THAN PRODUCTS

Essilor Instruments provides a wide range of cutting-edge technology, bringing you access to innovative
equipment in order to deliver the very best in patient care. We aim to provide pioneering optical instruments
to meet the needs of eye care professionals, helping to improve efficiency and quality of service. With the
right instruments, you can also strengthen your trusted relationships with patients and inspire loyalty and
satisfaction.

Essilor Instruments is a leader in visual screening Why choose Essilor?


tools, along with diagnostic and imaging equipment, Meet your patients’ needs and find the right optical
providing the latest in measuring and connectivity instruments that can really make a difference.
solutions. Over the last few years, Essilor Instru­ Founded in 1972, we invest millions into research
ments has won five Silmo d’Or innovation awards. and development to provide effective solutions for
independent opticians. We have more than 20
With more than 160 years of innovation and research partnerships with universities and public
expertise, our mission has been to help improve research organisations.
lives by improving sight. Essilor optical instruments
are distributed across more than 100 countries We also have a commitment to sustainability, and
around the world. have often been recognised as one of the world’s
best performing companies in terms of sustainable
Choose from refractometers, aberrometers, development. As we continue to meet new vision
phoropters, OCTs, topographers, tonometers and challenges, our optical instruments are becoming
more; not forgetting ergonomic furniture for your more tailored to the needs of every individual. Inno­
practice too. vation is at the heart of everything we do, bringing
the latest optical technology to independent opti-
cians across the country and beyond.

In addition, the Essilor Instruments division has a


dedicated team supporting Eye Care Professionals.
We offer technical advice, sales support, training
and financial / rental solutions.

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 5
1
OPTOME TRY
1. Optometry

8 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
1. Optometry
NON-CONTACT TONOMETER

An indispensable device in the glaucoma decision making process

Measurement 1 to 60mmHg or 0.1 to 8kPa


Soft air puff to enhance patient
comfort.
No measurement 1mmHg or 0.1kPa

Accuracy ±5mmHg or ±0.7kPa IOP value automatically corrected


based on central corneal
Working distance 11mm thickness.

Back/forth ±22mm
Measurement unit Right/left ±43mm
Up/down ±17mm

Screen size 5.7’’

Power saving function 3, 5, 10min

Printer Thermal printer

Connectivity RS-232C

Dimensions 422 (L) x 240 (W) x 430 (H) mm

Weight 13kg

Power Supply 100 to 240V - 50/60Hz

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 9
/
1. Optometry

SUPERIOR IMAGE QUALITY

Antibearum erchill abores ma quia ea dolumentorum dent.

Enhance the eye exams and patient management with the SL


650 digital slit lamp by easily taking high-resolution images and
videos to facilitate diagnosis and monitoring over time. Thanks
to its smart design and powerful software, you can now ana-
lyze and compare multiple images of the anterior and posterior
chamber, monitor functional signs and examine the patient’s
Meibomian glands. A complete and hasslefree eye assessment
that you can also share with your patients. Upgrade to the
SL 650+ for complete dry eye diagnostic capacities.

Improved image quality and facilitated diagnosis


x Maximize accuracy and comfort with a high quality optics
x HD digital system records all details in high-resolution image
and video for precise and detailed assessment
x Integrated yellow and blue-cobalt filters provide high contrast
fluorescein images for easy & accurate contact lens fitting

Digitally optimized patient management


x Integrated Anaeyes SL software and DICOM support mean
easy patient management, from the creation of patient to
follow up over time
x Easily record and share high-quality images with patients
x Clear results help educate patients and build trust

Simplified ergonomics, enhanced analysis


x Automatic functions, easy installation and built-in power supply
x An advanced integrated infrared system to assess meibography
x Measure pathology, edit image settings, and compare multiple
pictures and follow-up patient

Upgrade easily to the SL 650+ for a cmpelete dry eye report


x 5 comprehensive and non-invasive tests for a complete dry
eye assessment, including: meibography, NIBUT (Non Invasive
Break Up Time), eye redness analysis, tear meniscus height,
and Lipid layer thickness
x Advanced software and AI-powered identification system con-
duct accurate analysis of imaging
x Generate and share a complete Dry Eye Report with patients

10 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
1. Optometry
Microscope
Dry eye module
Microscope type Galilean type

Magnification change Revolving drum 5 steps AI non-invasive tear break up time


‚ AI identify the break up area time
Total Magnification 6.3x, 10x, 16x, 25x, 40x ‚ Automatic first break up time
‚ Automatic average break up time
Optical Resolution 2700 N Ip/mm (200 lp/mm) ‚ Visible light Placido ring projection (23 ring)

Eyepieces 12.5x
AI Meibomian glands function
Angle between ‚ Evaluation
10º
Eyepieces ‚ AI identify Meibomian glands
Pupillary adjustment 52mm-80mm ‚ Automatic Meibomian glands loss classification

Diopter adjjustment -8D~+8D Eyelid Margin


‚ Optical magnification
Field of view Ø36.2mm, Ø22.3mm, Ø14mm, Ø8.9mm, Ø5.7mm ‚ Electronic amplification
System specifications
AI non-invasive tear meniscus height
Automatic exposure/Automatic white balance/Adjustable depth of field and ‚ AI identification system
Digitale module
aperture
‚ Automatic non-invasive tear meniscus height
Image sensor 1/1.8-inch sensor/2.4µm pixel/5.0M pixels ‚ Optical magnification
‚ Electronic amplification
Photo resolution 2592 x 1944
Lipid layer thickness
Format jpeg
‚ Template comparison evaluation
‚ Visible light White ring projection system
Video resolution 2592 x 1944

Frame of video 25fps Dry eye examination report


‚ Automatic analysis report
Video formats MP4 H. 264

Exposure mode Automatic exposure AI conjunctival hyperemia analysis


‚ AI identification system
Transmission interface USB ‚ Automatic conjunctival congestion percentages
‚ Automatic ciliary congestion percentages
Software Anaeyes SL.
Cornea sodium flourescein staining
Power supply
‚ Eye surface damage report
Input voltage ~100V-240V ‚ Built-in yellow filter
‚ Cobalt blue filter
Input frequency 50Hz/60Hz

Rated current 1.2A

Ouotput voltage LEd 3V, Fixation 15V

Computer specifications

PC configuration i5-10500T 8G memory 250GB SSD+1TB storage

Display 1920x1080 23.8 inch

PC system Windows 10 / Windows 11

Packaging

Dimension 740mm x 450mm x 530mm (L/W/H)

Gross weight 23kg

Net weight 17kg

Slit illumination

Slit width 0~14mm continuous (slit becomes a circle at 14mm)

Slit lenght 1~4mm continuous

Aperture diameters Ø14mm, Ø10mm, Ø5mm, Ø3mm, Ø2mm, Ø1mm, Ø0,2mm

Slit angle 0º

Slit inclination 5º, 10º 15º 20º


Heatabsorbing filter, ND filter, Red-free filter, Cobalt blue filter. Built-in eye
Filters
yellow filter
Lamp LED

Luminance ≥150klx

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 11
1. Optometry

PREMIUM
SLIT LAMP

The professional
solution for complete
examinations of the
anterior eye structure

Lighting system High


High quality optics and cutting-edge
Magnification Drum, 5 steps
LED illumination.
6 x (37mm)
10 x (24mm)
Magnification range 16 x (14mm)
25 x (8mm) 5 magnification levels.
40 x (5.2mm)
Illumination type LED
Magnification type Convergent Galilean Many slit adjustments
Filters Cobalt blue - Green - Red - Grey - Yellow (optional)
and light tilting features.
Slit angle 0° to 180°
Slit length 1mm to 14mm Wide range of filters: cobalt blue, green,
Slit width 0mm to 14mm
red, neutral density.
Standard eyepiece 12.5 x
Pupillary distance 52mm to 78mm Integrated yellow filter
Tilt 0°, 5°, 10°, 15°, 20°
and background illumination.
Accessories Yellow filter / diffuser filter / background light
Tonometer / polarized filter / micrometric eyepiece / observation HD Digital camera DS 550 (optional).
Options
tube
Connectivity Yes

12 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
1. Optometry
SLIT LAMP

Essential features to fit most eye

Lighting system High (SL 450) / Low (SL 400)


Magnification Drum, 5 steps Classic Galilean typemicroscope.
6 x (37mm)
10 x (24mm)
Magnification range 16 x (14mm) Easy selection of magnification by rotating
25 x (8mm)
drum.
40 x (5,2mm)
Illumination type LED or Halogen
Magnification Type Galilean Tilt tower up to 20° (SL 350/SL 450).
Cobalt blue / Green / Anti-caloric (for halogen lighting) / Grey /
Filters
Yellow (optional)
Slit angle 0° to 180° Standard filters: thermal safety, cobalt blue
Slit Length 1mm to 14mm and green (red-free).
Slit width 0mm to 14mm
Standard Eyepiece 12.5 x
Halogen or LED illumination source.
Pupillary distance 48.5mm to 80mm
Tilt 0° (horizontal)
Accessories Yellow filter / Diffuser filter / Background light Continuous adjustment of the slit aperture
Options Tonometer / polarized filter / micrometric eyepiece / observation tube with 14mm aperture.
Connectivity -

Optional accessories
To expand and enhance
the power of your slit lamp,
discover our wide range of
accessories on
www.meyestore.com

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 13
1. Optometry

TAKAGI 700GL SLIT LAMP

This slit lamp is the number one performer behind the scenes.

New LED Optimized Slit Lamp


Innovative Design: No cables are exposed.
x One of the best advantages of LED illumination is that affected Even the power supply cable is concealed
anatomy and structures of the eye can now be more clearly
and visibly seen.
Conventional power cable from the chinrest
x By simply replacing the halogen light source with an LED type, to the light housing has been eliminated – now
700GL has been designed and engineered from scratch to neatly concealed inside the slit lamp body
accommodate the new superior LED lamp.
x LED optimized 700GL provides brighter and sharper light. 700GL looks neat and compact with no exposed
cables, giving a sleek look with an innovative
design.
Clear Observation of both Anterior and Posterior Segments of the Eye
x As a result of our continuous pursuit in improving visibility of the
Even cables for connecting an imaging
fundus while simultaneously maintaining superior visibility of the system can be concealed
anterior segment, the best, brightest, and sharpest optical de-
sign of 700GL has been achieved.
x 700GL's binocular tubes with a 6-degree convergence provide New product color. Background illumination
also discreetly built in with no exposed cables
easy binocular fusion ensuring a stress free observation.

Extended Slit Length


x The diameter of the slit length is extended to 14mm from
10mm. This allows 700GL to illuminate a wider area of the
anterior segment.
x This allows 700GL to maximize it's characteristics such as a
wider field of view.

Improvement of Usability
x The size, placement and other features of various controls are
reconsidered based on ergonomics in order to enhance usability.

Built-in Background Illumination


x For use with an imaging system, the background illumination
is now equipped as standard.
x The color balance of an image taken through 700GL is not lost
because the same LED is used for both main light source and
background illumination.
x Intensity of the background illumination is adjustable by hand
using the lower left hand side control.

The availability of the product will vary depending on the market

14 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
1. Optometry
TAKAGI 4ZL SLIT LAMP

A simple and practical slit lamp ideal for routine examinations

High-grade Slit Lamps without a cable


x 4ZL: High-performance with a 5-step magnification changer
x 2ZL: Excellent performance with a 3-step magnification changer
x Innovative Design: No cables are exposed. Even the power
supply cable is concealed.
x Even cables for connecting an imaging system can be concealed.
x New product color

Converging Binoculars
x Binocular tubes with a 6-degree convergence provide easy
binocular fusion, ensuring stress-free observation.

Improvement of Usability
x The size, placement and other features of various controls
are reconsidered based on ergonomics in order to enhance
usability

Built-in Background Illumination (4ZL only)


x For use with an imaging system, the background illumination is
now equipped in 4ZL as standard.
x The color balance of an image taken through 4ZL is not lost
because the same LED is used for both main light source and
background illumination.
x Intensity of the background illumination is adjustable by hand
using the lower left hand side control.

Reduction of Patient’s Uneasiness


x When 4ZL / 2ZL are switched on, a circular blue LED lights up
around the lower part of the slit unit, which does not disturb the
examination. The blue LED light is associated with mental calm-
ness, reducing patient’s uneasiness.
x Because the circular blue LED indicates the power is on, the
users can examine with 4ZL / 2ZL at ease.

Various Options
x Patient's hand rests and various other options for 4ZL/2ZL are
available according to users' requirements and application.

The availability of the product will vary depending on the market

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 15
1. Optometry

PHOROPTER

Immersive refraction station

Change your business potential with just one device. The Vision-S
Eliminating the need for the traditional chart
700 is a complete refraction room concentrated into one immersive distance, freeing up the space to grow your
station, expanding your refraction capacity through speed, ease business.
of use and ultra compact size. The unique patient experience not
only drives traffic but also helps convert sales. Patented algorithms combined with the optical
module enabling Digital Infinite Refraction™ to
ensure an accurate refraction in only 3 minutes.

Fully accessible to operators of varying levels.


Centering
49.0 to 80.0mm at far distance (in 0.50mm steps)
Pupillary Distance
55.0 to 83.0mm at near distance (in 0.50mm steps)
From 4.0 to 30.0mm in 0.5mm steps, monocular, Patented immersive imaging creates a truly
Vertex Distance unique patient experience and relaxed
measured by cameras
accommodation.
Measuring range

Sphere From -20.00D to +20.00D Prescription can be demonstrated in action


Up to 8.00D depending on the lens combination. with patented life-like scenarios, helping to
Cylinder from -7.00D to 8.00D with sphere at 0D increase lens conversion.
Cylinder
- In “Standard” mode: 0.25D increments with adjustable steps
- In “Intelligent” mode: multiple larger and smaller increments
3 out of 4 people prefer being tested on
Axis 0° to 180° in 1° increments, with adjustable steps the Vision-S 700 compared to a traditional
phoroptor.
Prisms 0 to 20∆ in 0.1∆ increments, with adjustable steps

Auxiliary lenses

Occluders Dark

Pinhole Yes

Retinoscopy lenses +1.50D, +2.00D (powered by optical module)

Fog Lenses +1.50D, +2.00D (powered by optical module)

Jackson Cross Cylinders ±0.25D, ±0.50D (powered by optical module)

Fixed Cross Cylinders ±0.50D (powered by opticalmodules) Console

3∆ base up, 3∆ base down, 6∆ base up, 10∆ base in


Prisms
(powered by varying prisms / diasporameters)
Maddox rods Red, horizontal and vertical

Red/green filters Red on right eye, green on left eye

Dimensions and weight

Compact refraction unit Length = 64.0cm. Width: 32.5cm. Depth: 55.0cm. Total weight: 16Kg

Console (keyboard + screen) Keyboard: 28 x 22cm. Screen display: 10.4”. Total weight: 3.0Kg

Product not yet available worldwide, please check availability with your business contact.

16 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
1. Optometry
PHOROPTER

Fast and secured refraction

In the past, obtaining a faster refraction meant trading-off on


Unique optical module permitting multiple
accuracy. This is no longer the case. Thanks to Essilor’s break- incremental power changes to secure a rapid
through refraction technology, the Vision-R 700 provides an ultra 0.25D proven accuracy.
rapid 3-minute refraction. This easy-to-use phoropter makes
exceptional performance the new standard, greatly adding to Simultaneous lens changes for a more direct
patient comfort and building customer loyalty. & controlled refraction method: Digital Infinite
Refraction™.

Patient specific program recommendation


Centering for guidance from start to finish.
49.0 to 80.0mm at far distance (in 0.50mm steps)
Pupillary Distance
55.0 to 83.0mm at near distance (in 0.50mm steps)
Automatic, compared to the position of the target for near vision Smart Programs for easy refraction by simply
Convergence
and to the patient's pupillary distance recording patient answers.
Vertex Distance From 4.0 to 30.0mm in 0.1mm steps, monocular, measured by cameras

Measuring range Improved patient experience thanks to a wider


field of view, silent lens changes and easy
Sphere From -20.00D to +20.00D answering method.
up to 8.00D dependent on lens combinations
Cylinder - in “Standard” mode: 0.25D increments with adjustable steps
- in “Intelligent” mode: multiple smaller and larger steps which round to 0.25D Instant power changes for easy comparison
Axis 0° to 80° in 1° increments, with adjustable steps and patient confidence.

Prisms 0 to 20∆ in 0.1∆ increments, with adjustable steps

Auxiliary lenses

Occluders Dark

Pinhole Yes

Retinoscopy lenses +1.50D, +2.00D (powered by optical module)

Fog Lenses +1.50D, +2.00D (powered by optical module) Console

Jackson Cross Cylinders ±0.25D, ±0.5D (powered by optical module)

Fixed Cross Cylinders ±0.50 D (powered by opticalmodules)


3∆ base up, 3∆ base down, 6∆ base up, 10∆ base in
Prisms Chart screen
(powered by varying prisms / diasporameters)
Maddox rods Red, horizontal and vertical

Red/green filters Red on right eye, green on left eye

Polarized filter Both linear and circular

Dimensions and weight


Phoropter
Width: 29.6cm at top - 21.9cm at bottom / height = 22.2cm. head
Head of the phoropter
Depth: 8.4cm at top - 6.5cm at bottom. Total weight: 3.5Kg
Console (keyboard +
Keyboard: 28x22cm. Screen display: 10.4’’. Total weight: 3.0Kg
screen)
Power supply Length: 16.3cm Width: 19.3cm. Depth: 5.8cm. Total weight: 1.0Kg

Product not yet available worldwide, please check availability with your business contact.

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 17
1. Optometry

PHOROPTER

Reinventing refraction

For many years, subjective refraction techniques have hardly


changed. Today, Vision-R 800 phoropter offers continuous Patented optical module which controls
power and provides prescriptions at 0.01D.
power changes and makes refraction more precise, easier to
perform for the practitioner and more comfortable for the patient!
Continuous and simultaneous changes of
sphere, cylinder and axis to improve efficiency
and accuracy.

Centering
50.0mm to 80.0mm in 0.1mm steps
Pupillary Distance Silent and instant lens changes.
Binocular and monocular adjustments
Automatic, in relation to near vision chart location and patient’s inter-
Convergence
pupillary distance
From 8.0mm to 30.0mm in 0.1mm steps
Vertex Distance
Monocular and measured by cameras Smart tests and unique algorithms.
Measuring range

Sphere From -20.00D to +20.00D


Smooth power changes and wider field of
Up to 8.00D vision to make the procedure shorter and the
For both sphere and cylinder: refraction more comfortable.
Cylinder - In “standard" mode: 0.25D increments, adjustable to 0.05, 0.10, 0.25,
0.50, 1.00 and 2.00D
- In “smart" mode: 0.01D increments
0° to 180° in 1° increments, with adjustable steps to 5°, 10°, 20°, 45° Customizable tests and programs.
Axis
and 90°
Prisms 0∆ to 20∆ in 0.1∆ increments, with adjustable steps to 0.5, 1, 2, 3 and 6∆

Auxiliary lenses
Possibility of comparing refraction in custom-
ized and immersive real life scenario.
Occluders Dark and translucent

Pinhole Yes

Retinoscopy lenses +1.50D, +2.00D (powered by optical module)


Compare multiple data such as lensmeter
and auto refractor with one click.
Fog Lenses +1.50D, +2.00D and manual (powered by optical module)

Jackson Cross Cylinders ±0.25D, ±0.50D (powered by optical module)

Fixed Cross Cylinders ±0.50 D (powered by opticalmodules)


3∆ base up, 3∆ base down, 6∆ base up, 10∆ base in (powered by
Prisms
varying prisms / diasporameters)
Maddox rods Red, horizontal and vertical

Red/green filters Red on right eye, green on left eye


Phoropter head
Polarized filter Both linear and circular

Connectivity
Data import from most lensmeters and auto-refractometers Chart screen
Connectivity
Data export to most practice management softwares
Printer Optional.

Power

Power supply AC 100V to 240V (50 / 60Hz) Console

18 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
1. Optometry
PHOROPTER PHOROPTER

High-end automatic An efficient solution for


phoropter for your refraction room
speed precision
The availability of the
and comfort product will vary depending
on the market.

Extensive range of lenses and filters to guarantee


Highly-intuitive, easy-to-use touch screen control.
quality refractions in far and near vision.

Tilt mechanism allowing easy optical axes conver-


Customizable test sequences.
gence for near vision exam.

Easy data transfer from lensmeter to streamline exam. Flexible and qualitative mechanical design.

Compare prescriptions in 2 clicks to speed final Rapid advance of lenses through a simple knob with
verification. automatic driving of the discs.

Quiet and high speed rotation disk for optimal patient


comfort.

-28.75D to +27.25D Sphere -28.75D to +27.25D

+6.00D Cylinder -6.00D

0° to 180° Axis 0° to 180°

0 to 20 Prism 0 to 20

48mm to 80mm Pupillary distance 50mm to 70mm

±0.25 / ±0.50 Cross cylinder ±0.25

30cm to 70cm Near charts range 40cm to 67cm

12mm, 13.75mm, 16mm, 18mm Vertex distance 11.5mm, 13.75mm, 15.75mm, 17.75mm
- Red filter - Red filter
- Green filter - Green filter
- Linear polarized filter (45° / 135°) - Linear polarized filter (45° / 135°)
- White & red maddox - White & red maddox
Auxtens
- Skiascopy glass - Skiascopy glass
- Cross cylinder ±0.50 - Cross cylinder ±0.50
- Pinhole - Pinhole
- Occluder - Occluder
Total Convergence Total

Controller keyboard Control system -

10’’ Screen size -

Yes Touch screen -

Yes Tiltable screen -

11 Key number -

Wired Wired / not wired -

- WFI / BT -

Yes Connectivity -

Integrated to the keyboard Printer integrated -

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 19
1. Optometry

AUTO KERATO-REFRACTOMETER

Automatic and easy AKR to enhance your daily practice

Sphere (refraction) -30D to +22D (step: 0.01/0.12(0.25D) The AKR 800 autokerato-refractometer
conducts precise and reliable objective
refraction and keratometry.
Cylinder 0D to ±10D (step: 0.01/0.12(0.25D)

Axis 0° to 180° (step: 5º/1º unit)


Deliver precise & reliable objective refraction

Min pupil diameter Ø 2.0mm


measurement
Refraction

Vertex distance 0, 10, 12, 13.5, 15mm Enhance your daily practice with
great user convenience
Light environment Photopic, Mesopic, Scotopic

Auto tracking 3D Auto (X-Y-Z directions) or manual Assess night vision and fit contact lens

Auto shot Available

Auto transition from right to left eye Available

Corneal curvature radius 5.0 to 10.0mm (step: 0.01mm)

Corneal refractivity 33.75 to 67.5D (step: 0.12/0.25D)


measurement
Keratometry

Degree of corneal astigmatism 0 to ±10D (step: 0.12/0.25D)

Axis Angle 1 to 180º (step: 5º/1º)

Peripheral measurement Ø7.0mm

Pupilllary distance 0mm to 85mm (step: 1mm)


measurement
Other

Pupil diameter Ø2.0mm ~ 8.5mm (step: 0.1mm)

ø12mm – (diagonal measurement: Ø14mm (step:


Corneal measurement
0.1mm)

10.4 inches color LCD monitor (TFT)


Screen
180º rotatable, 40º tiltable

Chinrest Motorized
specifications

Printer Thermal line printer with auto-cutter


Hardware

Data output LAN, USB-A, RS-232C

Dimensions & weight 271(W) x 464(D) x 482-523(H)mm – 22kg

Power source 100-240V AC, 50/60Hz, 90VA

20 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
1. Optometry
AUTO KERATO- AUTO KERATO-
REFRACTOMETER REFRACTOMETER

Advanced refractive Convenient and


measurementwith quick easy-to-use objective
and simple operation refraction

Integrated periphery keratometry measurement for


High-accuracy measurement on even small pupils.
contact lens fitting.

Guided alignment that automatically starts measure- Cornea, pupil & hard contact lens diameter easy
ment when pupil is focused. measurement.

Pupil size measurement in scotopic and photopic


Measurement Protocol Customization.
light conditions.

Screen tilts and swivels for comfort when seated or Instant access & display of last 10 measurements
standing. stored in memory.

Automatic data transfer to APH 550. Assistant measurement function.

Unique technology: « Live mode » to assist ECP's


measurement.

-30D to +22D Sphere (refraction) -25D to +22D


measurement
Refraction

0D to ±10D Cylinder 0D to ±10D

0° to 180° Axis 0° to 180°

5mm to 10mm Curvature radius (Keratometry) 5mm to 10.2mm


Keratometry measurement

33.75D to 67.5D Corneal refraction 33D to 67.5D

0D to ±10D Cylinder 0D to ±15D

0° to 180° Axis 0° to 180°

- Peripheral keratometry Yes

- Eccentricity Yes

0, 10, 12, 13.5, 15mm Vertex distance 0, 10, 12, 13.5, 15mm

2mm Minimum pupillary diameter 3mm

2mm to 8.5mm (pupil only – auto) Pupil diameter measurement 2mm to 8.5mm

10mm to 85mm PD measurement 10mm to 88mm

5.7’’ (40° tilt, 30° pivot) Screen size 5.7’’ (40° tilt)

- Touch screen Yes

Manual Chinrest Motorized

- Auto-focus Yes

Yes Auto-shooting Yes

Integrated Printer Integrated

RS-232C Connectivity RS-232C

430 (H) x 422 (D) x 240 (W) mm Dimensions 450 (H) x 500 (D) x 260 (W) mm

13kg Weight 20kg

230V AC Power supply 230V AC

The availability of the product will vary depending on the market.

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 21
TRK-2P
1. Optometry

AUTO KERATO-REFRACTO-TONOMETER

The TRK-2P combines a refractometer, keratometer, non-contact


tonometer and pachymeter in one compact instrument.

The TRK-2P features a fully auto alignment system with auto


measurement function. The compact size and 8.5 inch rotating 4 in 1: refraction, keratometry, tonometry &
pachymetry
color touchscreen control panel offers total flexibility for the
operator and also instrument location.
Fully automatic
Cataract mode
The TRK-2P has a built-in function that allows the measurement
of patients who have cataract or opacity. This function works
automatically or manually. Soft air puff

Soft air puff


Improved nozzle design controls the optimal amount of air required
for every IOP measurement. A softer air puff improves patient Rotary Prism
comfort and results in an improved measurement experience.
With just one touch of the
fingertip on the control panel
Adjusted intraocular pressure (IOP)
the Topcon TRK-2P will
The pachymeter function can be used to adjust the measured IOP
measure both eyes accurately
value depending on the cornea thickness. The integrated formula
due to Topcon’s exclusive
for IOP adjustment can be customized by the eye care practitioner.
Rotary Prism Technology™.

REF Measurement Specification

Measuring range Spherrical refractive power: -30D to ±25D (0.12/0.25D steps)*

Minimum measureble pupil diameter ø 2.00 mm

PD measurement range 20 to 85mm (1mm step)

Target fixation Auto fog system

KRT Measurement
Corneal curvature radius: 5.00mm to 13.00mm (0.01mm step).
Corneal refrative power: 67.5D to 25.9612D (0.12/0.25D
Measuring range steps) (where corneal refractive power = 1.3375D) Corneal
astigmatic power: 0D to ±12D (0.12D/0.25D steps). Direction
of corneal astigmatic axis: 0º to 180º (1º/5º steps).
Ocular Pressure Measurement

Measuring range 1 to 60mmHg (1mmHG step)

Corneal Thickness Measurement

Measuring range 0.400mm to 0.750mm (0.001mm step)

Others

Chinrest travel distance Up/down: 67mm

Other Specification

Dimensions 293-396mm(W) x 505-601mm(D) x 470-682mm(H)

Weight 22.0kg

Power Supply 100-240V AC, 50-60Hz, 100VA

* -30D≤ spherical refractive power + cylindrical refractive power or spherical refractive power + cylindrical refractive power ≤ +25D

The availability of the product will vary depending on the market

22 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
1. Optometry
LENSMETER

Unique combination of the latest Lensmeter Technologies

The new generation of lensmeter measures both harmful and


beneficial blue light transmission and an easy lens measurements. Measurement technology using the green
light beam.
The exclusive design of the marking system enables blocking and
marking in one single operation.
Lens support adapted to all lenses and
frames curves.

Measuring range

Sphere 0.0D to ±25D – (0.01 / 0.12 / 0.25)


Guided and automated prism marking.
Cylinder 0.0D to ±10.0D

Axis 1° to 180°

Addition 0.0D to 10.0D – (0.01 / 0.12 / 0.25) Measurement of UV transmission.

Prism 0.0∆ to 10.0∆ – (0.01 / 0.12 / 0.25)

Wavelength 525nm
Measurement of inter-pupillary distance.
Type of measurement

Lenses / frames Unifocals, multifocals, progressives

Tints Up to class 4 (>5%)


Ergonomic design with tilting color screen.
Contact lenses Soft and hard (dedicated support)

Measurement of UV transmission 0% to 100% (-25D to +25D)

Wavelength 375nm (UV-A) Data transfer to automatic phoropter or Patient.

Inter-pupillary distance 45mm to 85mm (0.5mm)

Screen LCD Color 5.7”


Management Software (PMS).
Integrated printer Yes

Connection RS 232 C

Dimensions 170 (L) x 205 (W) x 468 (H) mm Printer.


Weight 4.7kg

Power supply 100V to 240V – 50/60Hz – 40V VA

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 23
1. Optometry

LENSMETER LENSMETER

Intuitive and practical Measurement of all


lensmeter for rapid and types of lenses and
accurate measurement frames

Measurement technology using the green light beam. Measurement technology using the green light beam.

Lens support adapted to all lenses and frames curves. Lens support adapted to all lens and frames cambers.

Measurement of UV transmission. Ergonomic design with tilting color screen.

Measurement of inter-pupillary distance. Built-in printer.

Ergonomic design with tilting color screen. Data transfer to automatic phoropter.

Data transfer to automatic phoropter.

Measuring range

0.0D to ±25D – (0.01 / 0.12 / 0.25) Sphere 0.0D to ±25D – (0.01 / 0.12 / 0.25)

0.0D to ±10.0D Cylinder 0.0D to ±10.0D

1° to 180° Axis 0° to 180°

0.0D to 10.0D – (0.01 / 0.12 / 0.25) Addition 0.0D to 10.0D – (0.01 / 0.12 / 0.25)

0.0∆ to 10.0∆ – (0.01 / 0.12 / 0.25) Prism 0.0∆ to 10.0∆ – (0.01 / 0.12 / 0.25)

525nm Wavelength 525nm

Type of Measurement

Unifocals, multifocals, progressives Lenses/frames Unifocals, multifocals, progressives

Up to class 4 (>5%) Tints Up to class 4 (>5%)

Soft and hard (dedicated support) Contact lenses Soft and hard (dedicated support)
Measurement of
0to 100% (-25D to + 25D) -
UV transmission
375nm (UV-A) Wavelength -

45mm to 85mm (0.5mm) Inter-pupillary Distance -

LCD Color 5.7” Screen LCD Color 5.7”

Yes Integrated printer Yes

RS 232 C Connection RS 232 C

170 (L) x 205 (W) x 468 (H) mm Dimensions 170 (L) x 205 (W) x 468 (H) mm

4.3kg Weight 4.3kg

100 to 240V – 50/60Hz – 40V VA Power supply 100V to 240V – 50/60Hz – 40V VA

24 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
1. Optometry
TEST PROJECTOR AND SCREEN

Wide choice of ETDRS optotypes with many polarized tests

Technology 16/9, LCD


24" polarized LCD display.
Screen size 24’’

Resolution 1920 x 1080 pixels


Projection distance: 2M to 8M.

Contrast From 100% to 1.5%

Luminosity (brightness) 300cd/m2


Customizable slideshow.

Projection distance From 1.5m to 8m

Test number 100 Wireless connection.

Polarisation Yes (linear and circular)

Optotypes Landoldt C, numbers, letters, ETDRS

- Astigmatism
- Jackson cross
- Cross cylinder
- Lines (horizontal / vertical)
- Duochrome test
- Binocular vision
- Fixation point
Masks and tests
- Aniseiconia
- Stereoscopy
- Phories
- Color vision
- Amsler grid
- Red / green
- Woth test

Connectivity APH 550, Vision-R 800

Remote control Yes

Dimensions 621 (L) x 468 (W) x 76 (H) mm

Weight 9kg

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 25
1. Optometry

A SCREEN TO TEST PROJECTOR


EASILY MEASURE AND SCREEN
VISUAL ACUITY
A must for LED
Test projector Technology
and screens

Over 100 kinds of charts. 50 charts.

High definition screen. Fast, quiet disk rotation.

Red and green charts. Long lasting LED light illumination.

Wireless connection. Projection distance: 2m to 7m.

4/3, LCD Technology 4/3, LED Lamp

19’’ Screen size 16’’ (to 5m)

1280 x 1024 pixels Resolution Not applicable (projector technology)

From 100% to 1.5% Contrast -

320cd/m2 Luminosity (brightness) 200cd/m2 (to 5m)

From 1.5m to 6m Projection distance From 2m to 7m

100 Test number 50

- Polarization Yes (linear)

Landoldt C, numbers, letters, Snellen, Children’s drawing Optotypes Landoldt C, numbers, letters, Snellen, Children’s drawing
- Lines (horizontal/vertical)
- Astigmatism
- Cross cylinder
- Astigmatism - Jackson cross
- Binocular vision - Worth 4 dots
- Coincidence - Binocular balance
- Aniseiconia Masks and tests - Duochrome
- Red / Green - Coincidence
- Heterophoria - Shober
- Stereoscopy - Phories
- Stereoscopy
- Fixation point
- Eye schematic
APH 550 Connectivity APH 550

Yes Remote control Yes

436 (L) x 362 (W) x 60 (H) mm Dimensions 248 (L) x 234 (W) x 336 (H) mm

5.5kg Weight 4.5kg

26 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
1. Optometry

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 27
2
MEASUREMENTS
2. Measurements

PERSONALISED MEASUREMENTS

Measuring system to bring outstanding customer experience

Visioffice X is an optical measuring system that gives you access


to state-of-the-art technology. Engineered with a number Top 3 benefits
of different features, Visioffice X can transform your patient for your practice
experience and make sure they keep coming back. x Precise and personalised
measurements
x Unique patient experience
x Enhanced patient interaction

Three cameras work simultaneously to


provide a 3D reconstruction of the eye-lens
combination in the front and views. Three
cameras work simultaneously to provide a 3D
reconstruction of the eye-lens combination
in the front and views.

The markers placed on the frames allow for the


statistical analysis of the patient’s natural
posture. The precision of the measurements
is one-tenth of a millimetre and one-tenth of
a degree.

The two infra-red cameras provide you with


the option of taking measurements through
tinted lenses without removing them.

1080x1920 resolution full HD touch screen


makes it possible to see the tiniest of
differences.

Dynamic point of sale function via its digital


screen to help enhance the image of the prac-
tice and offer a more compelling experience
in the front of the practice.

Through vocal and visual instructions, the


Visioffice® X gives the patient a greater
appreciation of the measurements taken.

Eyecode™ technology - 3D Measurements of


Personalised lenses with Varilux XR the exact position of the Eye Rotation Centre
Near Vision Behaviour - The wearers behaviour
while performing a near vision task H3D
analysis - Analyses the natural posture of the
patient in far vision with an accuracy of one-
tenth of a degree.

30 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
2. Measurements
PERSONALISED MEASUREMENTS

Go a step further in lens personalisation with H3D

With its latest pure and elegant design coupled with new features,
Visioffice® 3 offers the high precision of the Visioffice range. It Top 3 benefits
contributes towards creating a memorable patient experience for your practice
and imposes itself as an indispensable tool for the sale of precise, x Personalised measurements
accurate and personalised lenses. x Interactive sales tool
x Precision & accuracy

Frame choice highlight Illustration of the


the in-store selection wearer’s benefits
x Automatic detection of the Accentuate the value of
patient’s face personalised lenses
x Fluid navigation of the inter-
face
x Compare different photos

Eyecode™ measurements Lens and treatment


lens personalisation options visual and realistic
x Pupillary distances in far vision demonstrations
x Fitting heights in far vision Go a step further in lens
x ERC and ELD personalisation with the H3D
options. The exclusive and
x Pantoscopic tilt and wrap angle patented H3D protocol carries
x Dominant eye out a study of the client’s Personalised lenses with Varilux XR
x Reading distance natural posture to ensure an
optimal visual comfort. The
x Near Vision Behaviour com- analysed posture is automati-
patible cally taken into account in the
measurements by Visioffice ®
3’s algorithms.

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 31
2. Measurements

WAVEFRONT ABERROMETER

Boost your patients' experience in practice

WAM™ 800 is a very intuitive, rapid and fully-automatic aberro-


meter that combines several technologies. This enables the eye Top 3 benefits
care professional to provide a comprehensive screening of the for your practice
eye in less than two minutes. x Fully automatic
x Fast eye screening
x Intuitive user interface

Improved tonometry using fixation point and IOP


value, automatically corrected according to the
corneal thickness.

Placido rings topography to help analyse over


100,000 points of cornea and provide the kera-
toconus probability index.

Using infrared retro-illumination, WAM 800 pro-


vides a detailed view of the crystal lens opacity,
helpful in identifying cataracts.

Individual autorefractometer and pupil measure-


ment for mesopic, photopic conditions and near
vision

Real time evaluation of the patient’s eye fatigue


when focusing on nearby objects

Topography and pupillometry for contact lens


fitting and keratoconus detection

The Wave Analyser can show the difference of


a patient’s day and night vision. In practice you
scientifically highlight this sensitivity with
different functions

The Wave Analyser can show the difference of


a patient’s day and night vision. In practice you
scientifically highlight this sensitivity with
different functions

32 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
2. Measurements
SUBJECTIVE REFRACTION

Refraction providing unique patient experience

The Vision-R 800 is an automated, accurate phoropter, complete


with unique SMART algorithms to assist you during the procedure. Top 3 benefits
for your practice
x Excellent patient experience
A more comfortable experience for the patient… x Automated phoropter
Smooth power changes and wider field of vision make refraction x More accurate than ever
very comfortable for the patients. The procedure is shorter and before
no fatigue is experienced. Answers are easier to give during the
refraction procedure. At the end, the Vision-R 800 phoropter
offers the opportunity to compare refractions in a customised
and immersive real-life scenario. A fascinating experience for
the patients!
…for complete confidence.

A more accurate phoropter…


Vision-R 800’s exclusive optical module controls powers at 0.01D
and delivers continuous and instantaneous changes of sphere,
cylinder and axis, at the same time. Refraction is made more
accurate, but prescriptions can also be made in 0.5 D steps.
Patients can now get the full potential of their vision!
…for a more precise refraction.

An easier procedure for the practitioner…


Thanks to its continuous and simultaneous changes of the sphere
power, cylinder axis and cylinder power, Vision-R 800 phoropter
generates a more precise refraction end point to 0.01D, compared
to traditional refraction methods. In addition, “Smart Tests” and
their unique algorithms assist the practitioner in conducting the
whole refraction procedure. Refraction is made both very easy
and very accurate!
…for a fully reliable prescription.

AVAILABLE WITH ESSILOR AVA LENSES

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 33
3
EYE HEALTH
3. Eye health

DRY EYE MANAGEMENT SYSTEM

Integrated system for the analysis of the ocular surface

Dry eye is the most common ocular condition encountered in


ophthalmic practice. IDRA is designed to perform tear film tests, Top 3 benefits
from the quality of tears to the analysis of the Meibomian glands. for your practice
x Offer expertise and diagnos-
tics of dry eye syndrome
x Attract more patients
Image resolution 5MP
x Positive patient experience
Acquisition mode Multi shot, video

Auto interferometry
Focus Autofocus, manual focus

ISO management Variable


Tear meniscus

Cones Main cone and Placid cone

Camera Coloured, sensitive to infrared (NIR), yellow-filtered Nibut with map and graph

Light source Infrared LED – Blue, red and white LED


Meibography (3D)

Functions Blink quality


The SBM Device is the new instrument for the individual analysis
of tear film that allows a quick detailed structural research of the
Blepharitis
tear composition.

Research on all the layers (Lipid, Aqueous, Mucin) and Meibomian


Ocular redness classification
glands.

Thanks to the SBM Device it is possible to identify the type of Pupillometry


Dry Eye Disease (DED) and determine which components can
be treated with a specific treatment, in relation to the type of
deficiency. White to white measurement

Anterior segment imaging

36 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
3. Eye health
EYE MASK

Innovative eye mask with heating and automatic squeezing


technology

This innovative eye-mask provides a complete heating and auto- How does it work?
matic squeezing technology in a fast and painless single device.
Touch screen controlled, user-friendly and
Effective on meibomian glands dysfunction associated with tear easy to manage. Through a fully automated
film evaporation. After each use the mask can be easily sanitized procedure the device is able to melt the
and does not require any gel during treatment as many other meibum inside the glands at 43°C and simul-
taneously squeeze them. This way releasing
devices do. the melted oil and allowing a strong improve-
ment of the lipid layer quality. The complete
procedure takes only 15 minutes.
The service provided will offer better comfort in daily life for lens
wearers, stressed eyes caused by heavy use of digital screens
will become fitter with each eye service application. Effective
on Meibomian glands dysfunction associated with tear
film evaporation.

x Unclog glands
x Melting the meibom
x Restore natural meibom flow
x Better pathology management
x Increase glands functionality

Improve your slit lamp

A dedicated platform for dry eye diagnosis, provides complete


dry eye tests according to the recommendation of TFOS DEWS
II report. Can be mounted on the majority of slit lamps.

x DSLC200 is the new Slit Lamp imaging system. Thanks to its


high optical quality it provides amazing images and videos.
The 3.1 MP camera with 1/1.8“ sensor and high-quality optical
image splitter offer incredible results.
x Switch your Slit Lamp into a complete dry eye assessment
test. The new DEM 100 fitting on any Slit Lamp allows a com-
plete Tear Film automated digital analysis.
x The DSLC200 device can also be used in combination with
the DEM 100 and is adaptable to your Slit Lamp System.
The devices can be installed in less than 5 minutes on your
Slit Lamp and transform it into a complete and unique diag-
nostic tool for dry eye. DEM100 DSLC200

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 37
3. Eye health

DRY EYE SOLUTION

Dry eye syndrome solution using intense regulated pulse light


technology

Dry eye syndrome is commonly caused by insufficient tears


or excessive evaporation. A large majority of cases are due to Top 3 benefits
evaporation caused by insufficiency of the external lipid layer of for your practice
the lacrimal film secreted by the Meibomian glands. An increase x Offer expertise and solutions
in screen usage, artificial lighting, air pollution and other elements for dry eye syndrome
from our modern lifestyle can make dry eye symptoms an ever x Attract more patients and
increasing nuisance. generate additional revenue
stream
x Increased patient satisfaction
The treatment
E-Eye generates sculpted, regulated train pulses. The energy,
spectrum and time are precisely set to stimulate the meibomian
The lacrimal film, necessary
glands in order for them to return to a normal function.
to the eye function, is made
Protective eyewear is placed over the patient’s eyes and optical
of three layers:
gel is applied on the cheek and temporal area. A series of five x The mucous layer, in contact
flashes is applied under one eye and then repeated under the with the ocular globe,
other. Sessions only take a few minutes with instant improvements. secreted by the conjunctival
mucous cells
For optimal results, it is recommended to run a full series of x The aqueous layer, secreted
by the lacrimal gland
treatments:
x The lipid layer, secreted by
meibomian glands
x Day 0
x Day 15 Lacrimal film Lacrimal gland
Mucous layer
x Day 45 Aqueous layer
x Day 75 (optional) Lipid layer

Meibomian
glands
Conjunctival
goblet cells

38 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
TEARSTIM

3. Eye health
DRY EYE SOLUTION

Dry eye syndrome solution using intense regulated pulse light


technology

Dry eye syndrome is commonly caused by insufficient tears


or excessive evaporation. A large majority of cases are due to Top 3 benefits
evaporation caused by insufficiency of the external lipid layer of for your practice
the lacrimal film secreted by the Meibomian glands. An increase x Offer expertise and solutions
in screen usage, artificial lighting, air pollution and other elements for dry eye syndrome
from our modern lifestyle can make dry eye symptoms an ever x Attract more patients and
increasing nuisance. generate additional revenue
stream
x Increased patient satisfaction
How TearStim works?
The procedure only takes a few minutes, giving you the chance
to go the extra mile to help maintain your patients’ eye health. The lacrimal film, necessary
With the patient sitting comfortably in a chair, the optician simply
to the eye function, is made
covers the patients’ eyes with protector shells and applies a
of three layers:
special gel.
x The mucous layer, in contact
A series of 8-10 light pulses is then aimed at the region below the with the ocular globe,
eyes, before being repeated in the same way on the other eye. secreted by the conjunctival
mucous cells
x The aqueous layer, secreted
The solution needs only three sessions to make a difference:
by the lacrimal gland
x The lipid layer, secreted by
x Day 0
meibomian glands
x Day 15
x Day 45 Lacrimal film Lacrimal gland
Mucous layer
x Day 75 (optional) Aqueous layer
Lipid layer

Analysis with tearcheck®


x 9 exams in less than 10 minutes Meibomian
glands
x Fully automatic imaging Conjunctival
goblet cells
x Unique usability
x Wireless data export & print
x PC inside
x Plug & Play
x High-end technology
x 2 patented examinations

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 39
EXPERT MYOPIA CARE
3. Eye health

BECOME A REFERENCE IN MYOPIA CARE. NATURALLY.

Naturally scale your expertise in myopia care

Expert Myopia Care is composed of Myopia Expert™ 700 and its


digital solution Essibox® Myopia Care, offering you a highly accurate Top 3 benefits
and turnkey resource that enables proactive myopia management. for your practice
x Offer myopia management
A fast and accurate solution for measuring axial length x Attract new patients
and corneal topography x Build patient loyalty
The Myopia Expert 700 is a corneal analyser with an integrated
pupillographer and optical biometer.
Naturally scale your expertise in myopia care
Essilor Instruments brings a scalable and
x Measurement of Eye Axial Length professional protocol to your practice for
effective and proactive myopia management,
x Corneal topography from the early detection to long term
x Fluorescence imaging for contact lens fitting monitoring.

x Pupil measurements
x Storage and overviews of historic ocular data properties for Build this expertise on an easy to adopt
solution
easy observation of changes over time. Myopia care made easy for you. All the exper-
tise at your fingertips.
Measurement specifications

Function Features Share your expertise to create long term


Axial length Low coherence interferometry customer relationships
Engage your patients in the long term, using
Keratoscopic cone: 24 rings equally distributed on a 43D sphere
Expert Myopia Care to explain clinical results
Analyzed points: Over 100,000 in a meaningful way.
Corneal topography
Measured points: Over 6,000
and keratometry
Corneal coverage: Up to 9.8 mm on a sphere of radius 8mm (42.2 diopters with n = 1.3375)
Focus system: Guided focus
Pupillometry Infrared LEDs + white LEDs for photopic pupil acquisition
Fluorescein Blue LEDs with barrier yellow filter
Measurement range and accuracy

Measurement Measuring range


Curve radius: 5.00 – 12.00 mm
Keratometry
Curve Radius in Diopter (D)(n=1.3375): 28.00 – 67.50 D
Axial length 15.00 – 36.00 mm
Pupil dimension 0.50 – 10.00 mm
Limbus (white-to-white) 8.00 – 14.00 mm
Electrical specifications
Power supply AC 100-240V 50/60 Hz
Power consumption 100 VA
Type: 20 x 5 mm
Fuse
Value: T 2.5 A L 250 V anti-surge
Mechanical specifications
Width 320 mm
Height 490 mm
Length 470 mm
Weight 18 kg
All-in-one instrument
PC on board Integrated PC with complete software and patient database
Touch screen Integrated monitor with capacitive touchscreen display
Motorized chinrest Integrated motorized chinrest completely managed by the software

40 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
OCT

3. Eye health
OPTICAL COHERENCE TOMOGRAPHER (OCT)

A fully automated OCT with true color fundus camera &


angiography**

Observation & photography of fundus image Easy to use & fully automatic OCT
allowing optimal patient posi-
Scan mode Color, red-free & IR tioning without operator action
for effective & fast screening.
45° ±5%
Picture angle
30° or equivalent (digital zoom)
Integrated live fundus imaging
Operating distance 34.8mm (in fundus photography)
and maximize OD/optometrist time
Normal pupil diameter: ø 4.0mm or more by locating region of interest exact
Photographable diameter of pupil position for an OCT-scan.
Small pupil diameter: ø 3.3mm or more

Observation & photographing of the fundus/tomogram


Efficient glaucoma screening
(on fundus) with 3D wide scan (12mm x 9mm)
Scan mode Horizontal direction 3-12mm allowing to screen fovea & optic
Vertical direction 3-9mm nerve in a single scan reducing
3D scan (horizontal/vertical) numbers of scan.
Scan pattern
Lineer scan (line-scan/cross-scan/radial-scan)

Scan speed 50.000 A-Scans per second Automated angiography** &


Anterior chamber (ICA, cornea
Lateral resolution 20μm or less thickness) analysis.

In-depth Resolution 6μm or less

Photographable diameter of pupil ø 2.5mm or more

Internal fixation target Dot matric type organic

Electric rating

Source voltage AC 100-240V

Power input 70-150VA

Frequency 50Hz-60Hz

Dimensions and weight

Dimensions 543-680 (L) x 340-480 (W) x 530-735 (H) mm

Power Input 25kg

Observation & photographing of anterior segment

Photography type Color & IR

Operating distance 62.6mm ±0.1mm (when taking a picture of anterior segment)

Observation & photographing of the anterior segment tomogram

Horizontal direction 3-6mm ±5%


Scan range (on cornea)
Vertical direction 3-6mm ±5%

Scan pattern Linear scan (line-scan/radial-scan)

Fixation target External fixation target

The availability of the product will vary depending on the market.

* Limited geographical coverage


** Angiography module priced as an additional option

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 41
3. Eye health

FUNDUS CAMERA

Streamline retinal screening in your practice

Automatization Fully automatic Next generation automatic


fundus camera
Minimum pupil size 2.5 Innovative and unique optical
design allows fast and high qual-
Field of view 45° up to 90° ity image capture with minimal
operator training.
Internal fixation points 7

Resolution 5MP (2448x2051) Optimized workflow with friendly


user interface
Built in software Yes Helping Eye Care Professionals
easily screen patients and open
Cup to disk ratio Yes doors to remote diagnostic or
digitally assisted evaluation.
MOSAIC function Yes

Light source LED


Designed for remote diagnostic
Connectivity Teleconsultation available with retina800.essilor.com and teleconsultation.

Dimensions 43 (L) x 34 (W) x 46 (H) cm

Weight 13kg
D 430
Printer integrated -

H 460mm

W 340

D 430

H 460mm

W 340

42 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
3. Eye health
CORNEAL TOPOGRAPHER

Precise diagnosis and effortless contact lens fitting

White and blue Light (470nm) Streamlined contact lens


Corneal topography and video keratoscopy
Light source
Infrared LED
fitting process
Pupillography and melbography
Precise evaluation of the corneal surface
Measurement points 6144 and wide variety of graphic presentations.

Working distance 78mm


Rapid and easy selection of the best lens
Digital camera Colors, high definition (1024 x 960px) thanks to fluorescent image simulation and
integrated database which includes lenses
- Graphical representation for an accurate evaluation of the anterior from 27 brands.
surface of the cornea
- Dynamic and static measurement of pupil diameter in scotopic, photopic
and mesopic vision Dynamic and static capture of the pupil reac-
Analysis
- Evaluation of tear film breakthrough time tion according to light conditions (scotopic,
- Real-time observation of tear film stability under blue and white light
photopic, mesopic).
- Evaluation and classification of the degree of atrophy of the melbomian
glands

Connectivity USB 3.0 – with the software


Advanced tear film analysis
Dimensions 320 (L) x 205(W) x 510 (H) mm for dry eye
Blue and white light image capture allowing
Weight 6kg
real-time observation of the tear film
clearance.
Source voltage 230V AC

Non-invasive measurement of the tear film


break-up time (pictures and videos).

Meibography with color scale enabling


evaluation of gland loss.

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 43
MEDMONT MERIDIA™
3. Eye health

ADVANCED TOPOGRAPHER

One system. Many choices.

The Medmont Meridia™ Advanced Topographer is designed


to improve patient outcomes and grow your practice with NEW
multi-purpose clinical evaluation options to fit your needs. This
system platform is available as a choice of two models – Classic
and Professional.

Built from the proprietary concepts of the E300, the Classic model
offers the same proven best-in-class topography, enhanced with a
larger color field-of-view and ergonomic quick keys for navigating
the software. The Professional model extends the features of the
Classic with anterior, fluorescein, and meibomian gland imaging
and videos. The Professional model also features a choice of pro-
ven dry eye grading scales and insightful reports. This evidence-
based approach with collaborative views and insightful patient
reports facilitates patient communication and engagement.

Key new features Medmont Meridia™ | Professional Medmont Meridia™ | Classic

Increased field of view topography


 
Optimized depth of field focus
 
High resolution digital color imaging
 
Horizontal visible iris detection
 
Scleral lens simulation
 
Medmont studio 7 improved user experience
 
Ergonomic quick keys on instrument
 
Convenient and secure calibration ball storage
 
Enhanced and quicker interface connections
 
Anterior imaging and video

Meibomian gland imaging

Fluorescein imaging and video

Tear meniscus height measurements

Scotopic and photopic pupil measurements

Focus guidance aid

Proven imaging grading scales
(EFRON, BHVI, Meiboscale) 
Dry eye patient screening reports

44 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
MEDMONT M700

3. Eye health
AUTOMATED PERIMETER

The Medmont M700 Automated Perimeter offers practitioners an


effective tool for assessing visual fields. With the advent of Fast
Thresholding capabilities to improve patient comfort, perimetry
is now more efficient for monitoring and assessment of disease.

Patient Reliability Indicators


x False Positives Rapid Testing Times

x False Negatives
x Fixation Losses
x Video Fixation Eye Tracking Monitor Full Field Coverage (160°)

x Automatic Fixation Tracking

Advanced Fast Threshold Testing Strategy,


Field Analysis Tools Employing Baysean Testing Techniques
x Glaucoma Progression
x Pattern Defect Index (PD)
Flicker Test Facility, With Proven Early Field
x Overall Defect Index (OD) Loss Detection Capabilities
x Cluster Analysis (Glaucoma) Index
x Regression Analysis Over Entire Field or Localised Areas
x Baseline Analysis

Display Options
x Grey Scale
x Numeric Decibel Data
x Patient Hill of Vision Deviation (Localised Defect Identification
x Age Normal Deviation (General Depression Identification)
x Severity of Loss Indicators (Relative Probability of Loss)

Result Outputs
x Customizable Page Layout
x Single Result Per Page
x Left Eye/Right Eye On One Page
x Difference Maps
x Multiprint with 5 Results Per Page (Extendable)
x Regression graphs printing: Pattern Defect Index,
Overall Defect Index, Data Histograms, OP, 3D Display

Microsoft Windows™ Based Software


x Multiple Workstations Connected to Central Database
x EMR/EHR Interface
x USB Computer Interface
x DICOM Interface

No Regular Professional Servicing and Maintenance Requirements.

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 45
4
FINISHING
4. Finishing

DELTA SERIES

The compact all-in-one edger

DELTA is a concentrate of technology for an optimal cost effective


Full parallel tasking
solution. Easy to use and intuitive it will raise your productivity. x Tracing, centering and blocking in parallel
Delta is also a excellent solution to complete your offer and pro- of edging without quality compromise.
x A unique user-friendly display to manage
vide a fast delivery service to your customers. all functions.

Fast and precise optical tracing


x Direct tracing without handling a lens
or any accessories.
Drilling tilt 0-15° x Shape recognition whatever the lens
position.
Chamfering Chamfering x Simultaneous recognition of shape and
drilling data.
Grooving Grooving
Place and trace
Polishing Polishing Polishing 3D technology
x With the curve and
frame base.
Flat edge finish Flat edge finish Flat edge finish
x Delta footprint is one
of the smallest of the
Bevel Bevel Bevel market.

Patented ergonomic
blocker
x Parallax-free centering
(video assistance).
x Natural and smooth
flow of movement.
x Delta is the only one
product which allows
to compensate a
deviation that occurs
during the blocking
without removing
the block.

Optical shape tracing

48 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
4. Finishing
NEKSIA SERIES

The simple edging solution for the daily workflow

Born in 2014 as the successor of Kappa range, Neksia’s success


EASIER WORKING PROCESS
is indisputable. It has been built thanks to a great mix of reliability, x 8.4-inch user friendly touch-
workflow efficiency, quality, and productivity. Now available with screen.
x Fast-access settings.
the high curve function, Neksia has a bright future ahead. x 1,000-job database.

EXPERIENCE WORKFLOW EFFICIENCY


x Fast, easy and extended frame
Drilling tilt 0-15° Drilling tilt 0-15° tracing.
x Embedded mechanical tracer
Smart optical tracing with
High curve bevel High curve bevel automatic axis and drill holes
recognition.
Chamfering Chamfering Chamfering Chamfering x Ergonomic environment for a
convenient centering.
x Automatic blocking.
Grooving Grooving Grooving Grooving

Polishing Polishing Polishing Polishing Polishing ACHIEVE HIGH PERFORMANCE


x Smart processing cycles to
guarantee sizing and axis even
Flat edge finish Flat edge finish Flat edge finish Flat edge finish Flat edge finish
for the most demanding lenses.
x Patented flexible chamfering
Bevel Bevel Bevel Bevel Bevel wheel.

HIGH CURVE

Specific wheels set for high curve lens

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 49
/
4. Finishing

ES RANGE

Reveal your creativity

The ES™ 800 is a compact and easy-to-use in-store finishing system. It is the perfect solution to demon-
strate your craftsmanship, reveal your creativity, and reinforce your expertise while enhancing the value of
your work. It incorporates Essilor’s state-of-the-art technologies giving it unparalleled edging possibilities.
It includes TCB™ 800, the new Automatic TCB (Tracer-Centerer-Blocker)

ES™ 800 combined ES™ 800 M combined


M'EYE CUSTOM™ WEB APP Screen size TCB & Edger and position
with TCB™ 800 with TCB™ 800

M'Eye Sign™ (Engraving)


  12¨ / 12:9 – Multitouch titable top vertical heads up
display
M'Eye Shape™ (Creative shape)
 
M'Eye Cip™ (Chemestrie cip)
  Dimensions Edger HxWxD (mm) and weight(kg)

M'Eye Diamond™ (Crystal pavé)


  H: 625 – W: 585 – D: 515 – 64kg
M'Eye SportRx™ (Half Jacket) NA

Dimensions TCB (Tracer-centerer-blocker)
MASTER YOU EDGING FEATURES HxWxD (mm) and weigt (kg)

Myopia Fit Automatic & Manual centering


  H: 597 – W: 306 – D: 515 – 25.9kg
Advanced optical tracinig
made for highly complex lens zones
and automatic drilling detection
  Power consumption & Power supply voltage
FULL High Curve™. TCB (Tracer-centerer-blocker)
3D Binocular mechanical tracing  
Fit 4 Frame Technology/ 2.0: Aesthetic 250W – 240-110V – 60/50Hz 5-3A
and robust mountings in all finished  
Automatic Centering & Booking with
Power consumption & Power supply voltage Edger
automatic adjustment of the centering data
based on the 3-D parameters of the frame
 
Hydrophobic lens Management Via Roughing Via Miling 1350Wz – 220-240V – 60/50Hz 10A
2000Wz – 100-120V – 60/50Hz 12A
Fast Roughing Cycle (FRC)
 
Remote maintenance and software and library
update including Embedded OMA shapes  
Front side USB stick sict to integrate
OMA shapes in local library  
Job management
 
FINISHINGS FEATURES

Bevel / Flat / Polish / Charmfering


 
Grooving & Drilling Tilt up to 30º
 
Mixed Finishing
 
High Curve bevel up to wrap 30º base 10
 
Shelf or asymmetric bevel
with adjustable height  
Mini-bevel
 
Step bevel up to 3 mm depth up to 5.5 mm depth

Back step bevel & inclined back step bevel


 

50 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
/

4. Finishing
ES RANGE

Master your edging

A compact and user-friendly in-store finishing system, composed of the ES™ 700 edger and TCB™ 800,
Automatic Tracer-Centerer-Blocker (TCB). It is the perfect solution to reach precision with ease.

ES™ 700 combined ES™ t00 M combined


MASTER YOU EDGING FEATURES Screen size TCB and position
with TCB™ 800 with TCB™ 800

Myopia Fit Automatic & Manual centering


  12¨ / 16:9 – Multitouch titable top vertical heads up
display
Advanced optical tracing mode for highly
complex lens zones and automatic drilling
hole detection
  Screen size Edger and position

FULL High Curve™. 3D binocular mechanical


tracing   10¨ / 16:9 – Multitouch top right display
Fit 4 Frame techonology / 2.0: Aesthetic and
robust mounting in all finishes   Dimensions Edger HxWxD (mm) and weigt (kg)
Automatic Centering & Booking with
automatic adjustment of the centering data
based on the 3-D parameters of the frame
NA
 H: 497 – W: 585 – D: 518 – 63 kg

Hydrophobic lens Management Via Roughing Via Miling Dimensions TCB (Tracer-centerer-blocker)
HxWxD (mm) and weigt (kg)
Fast Roughing Cycle (FRC)
  H: 597 – W: 306 – D: 515 – 25.9 kg
Remote maintenance and software and library
update including Embedded OMA shapes   Power consumption & Power supply voltage
Front side USB stick sict to integrate TCB (Tracer-centerer-blocker)
OMA shapes in local library  
250W – 240-110V – 60/50Hz 5-3A
Job management
 
Power consumption & Power supply voltage Edger
FINISHINGS FEATURES
1350Wz – 220-240V – 60/50Hz 10A
Bevel / Flat / Polish / Charmfering
  2000Wz – 100-120V – 60/50Hz 12A

Grooving & Drilling Tilt up to 30º


 
Mixed Finishing
 
High Curve bevel up to wrap 30º base 10
 
Shelf or asymmetric bevel
with adjustable height  
Mini-bevel
 
Step bevel up to 3 mm depth up to 3.5 mm depth

Back step bevel & inclined back step bevel


 

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 51
PRO-E SERIES
4. Finishing

EDGE AHEAD WITHOUT COMPROMISE

Edgers designed to meet high productivity


and uncompromising quality

The most compact industrial edger on the market, PROE will Versatility
be ideal for a workshop handling more than 60 jobs per day. x All types of mountings and
It achieves a high level of productivity especially on the most finishing.
x All materials except glass.
demanding job without any compromise on the quality.
Precision
x Top-end edger precision.
x Advanced processes to enable
faultless sizing, axis control &
aesthetic mountings.

Chemistrie™ Robustness
x Specific durable tools.
x Easy & fast maintenance
Creative shape processes.

Engraving Easy integration


x Compact table top format.
Half jacket x No need for compressed air.
x Intuitive & user-friendly MMI.
x Large range of configuration.
Super chamfer
Productivity
Step bevel Step bevel x Productivity gain: up to 50%.¹
x Groove: 3X faster. ¹
High curve bevel - Up to wrap 30°, base 9 High curve bevel - Up to wrap 30° Base 9 x Drill 4 holes: 2X faster.¹
x Dry milling to secure hydropho-
bic lenses as fast as roughing
Milling Milling wheels cycles.²
x Start and stop mechanical
button and bar code scanner
All type of mixed jobs All type of mixed jobs
embedded.

Drilling tilt up to 30° Drilling tilt up to 30° ¹ Versus standard ECP table top finishing system.
² Versus 2 stars cycle.

Chamfering Chamfering

Grooving Grooving

Polishing Polishing

Flat edge finish Flat edge finish

Mini bevel (option) Mini bevel (option)

Bevel Bevel

52 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
4. Finishing
Feeler metal pin

Technician tool case


Robotic cable
& connection

Perfect lens thickness


measurement with free wear pin

Ref: M40TB1

Parts & tools


Easy & fast maintenance
Longer life time

Milling Design for productivity

Dry cutting process to fully secure A unique Embedded


lens axis deviation during roughing start button barcode reader
and eliminate bad smell from MHI

Need Essibox® solution

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 53
TRACERS AND BLOCKERS SOLUTIONS
4. Finishing

PRODUCTIVITY

Complete range to meet all the professionnal need

Tess tracer and PRO B blockers are renowned worldwide for


Patented frame groove acquisition
their performances and are used in Essilor Service Centres. for a perfect lens size adjustment
Their design is optimized to meet the most demanding level of and fitting
productivity and accuracy.

Centering-blocking Tracing centering-blocking

Auto recognize holes Auto recognize holes

Pedal for blocking (option) Pedal for blocking (option)

Scanner holder Scanner holder

Weco block compatibility Weco block compatibility

Manual centering Manual centering


& Automatic blocking & Automatic blocking

Lab use Lab use

Shape and drilling libraries Shape and drilling libraries Shape and drilling libraries

Reinforced table (>100kjob)

User comfort User comfort User comfort

Shape modification Shape modification Shape modification

High curve frame High curve frame High curve frame


(up to base 9) (up to base 9) (up to base 9)

54 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
4. Finishing
Remote edging solutions Reinforce tracing table for lab volume*

A pedal (optional) Pro-B 300

Start the blocking With or without


process without touching robust reinforce tracing
the screen table

*Lifetime: more than 100 000 jobs

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 55
ESSIBOX
4. Finishing

CONNECT

The connectivity solution to increase lab efficiency

ESSIBOX® connects multiple devices and centralises upgradable solution that enables the gradual
all data flow for a higher lab efficiency. Designed addition of new functions and services, enhancing
around an open communication system, it is an profitability for the organisation.

Unlimited storage capacity and integrated database


Create an unlimited archive of shapes and drilling models
with a easy management of the libraries:
x Multi-criteria searches
(search by manufacturer, by collection or by model).
x Immediate visualisation of the shape
and the related drilling pattern.

Creation of personalized shapes and drilling patterns


x Shape and drilling creation module.
x A user friendly design, based on the underlying principles
used for computer aided design software.

Job management and LMS1 / PMS2 connection


x Automatic data transfer (shape, prescription, height, PD, lens
type, etc.) to the centring and egding system with barcodes.
x Visualisation and management of all the jobs and their states
of progress.
x Full integration within the lab and/or store network for an easy
and quick access.

Multi-site
Centralized workshop and/or Job transfer between shops:
x Delegation for capability need.
x Delegation for functionality need (creative shape...).
x Delegation for availability.

56 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
4. Finishing

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 57
5
FURNITURE
5. Furniture

REFRACTION UNIT

Ophtalmic refraction unit for advanced practice

Chair maximum load 150kg


3 instruments sliding table.
Dimensions: 42cm x 82cm
Sliding tabletop
Max weight: 40kg

Versions Right or left handed version Projector holder and self-balancing refractor
arm².
Power supply 110/230 V- 50/60 Hz

Dimensions 1.68 (L) x 1.80 (P) x 1.90 (H)m Variable LED lighting, near vision lamp, fixed
chinrest, dual voltage and accessories holder.
Weight 240kg

Wheel chair accessibility, magnetic brake


and keypad on table side.

Options
3 instruments table top.
x Additional screen holder (OST048)
x Additional projector plate (OST202)
x Electric arm (OST380) Room light condition control at table side
x Additional shelf (OST377) (keypad).

x Drawer and shelf optimum design (OST376)

Colors available for lateral covers

Red: OST386 – Blue: OST384 – White: OST385

60 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
5. Furniture
REFRACTION UNITS

Ergonomic and comfortable motorized refraction unit for daily use

OST 250 configuration


Chair maximum Load 150kg

Dimensions: 42cm x 82cm 2 instruments sliding table


Sliding tabletop
Max. weight: 40kg

Versions Right or left handed version

Projector holder and self-balancing refractor


Power supply 110/230V-50/60Hz arm².

Dimensions 1.26 (L) x 2.14 (W) x 1.90 (H) m


Variable LED lighting, near vision lamp, fixed
Weight 240kg chinrest, dual voltage, accessories holder.

Motorized chair with 90 tiltable back.


Options

x Additional screen holder (OST048) Drawer integrated.


x Additional projector plate (OST202)
x Electric arm (OST380)
x Additional shelf (OST377) Motorized table.
x Drawer and shelf optimum design (OST376)

OST 250H configuration


Colors available for lateral covers
OST 250 configuration.
OST250 / Red: OST010 – Blue: OST020 – White: OST030
OST250H / Red: OST253 – Blue: OST251 – White: OST252
Wheel chair accessibility, magnetic brake.

OST250C

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 61
5. Furniture

REFRACTION UNIT

Comprehensive refraction unit for small place

Chair maximum load 150kg


2 instruments sliding table.
Dimensions: 42cm x 82cm
Sliding tabletop
Max weight: 50kg

Versions Right or left handed version


Motorized chair.

Power supply 230V-50/60Hz

Dimensions 1.25 (L) x 1.5 (W) x 1.80 (H) m


Projector plate.

Weight 195kg

Self-balancing refractor arm.

Options
LED lighting.
x 5cm spacer (OST046)
x Near vision lamp (OST208)
x Additional projector plate (OST202) Lift-up elbow rests and footrest.
x Additional screen holder (OST048)
x Comon chinrest adapter (OST210)
x Accessories holder (OST047)

Colors available for lateral covers

Red: OST010 – Blue: OST020 – White: OST030

62 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
5. Furniture
REFRACTION UNIT

Comprehensive refraction unit for small place

Chair maximum load 150kg


2 instruments sliding table.
Dimensions: 42cm x 82cm
Sliding tabletop
Max weight: 50kg

Versions Right or left handed version


Motorized chair.

Power supply 230V-50/60Hz

Dimensions 1.25 (L) x 1.5 (W) x 1.80 (H) m


Projector plate.

Weight 195kg

Self-balancing refractor arm.

Options
LED lighting.
x 5cm spacer (OST046)
x Near vision lamp (OST208)
x Additional projector plate (OST202)
x Additional screen holder (OST048)
x Comon chinrest adapter (OST210)
x Accessories holder (OST047)

Colors available for lateral covers

Red: OST010 – Blue: OST020 – White: OST030

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 63
MOTORIZED SIDE TABLES AND STOOLS
5. Furniture

STOOLS
MOTORIZED TABLE FOR ONE INSTRUMENT CHROME FIVE-STAR BASED

Table size 435x600mm / Hmaxi 840mm / Hmini 670mm Exists in 3 colors 1080x480m / Hmaxi 940mm / Hmini 670mm

Max loading 75kg Colors available Blue: RUEA18 – Red: RUEA19 – Black: RUEA17

64 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
5. Furniture

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 65
6
LOCAL
PRODUCTS
HENSON 9000
6. Local products

OPTIMISED VISUAL FIELD SCREENING AND ANALYSIS

The Henson 9000 visual field analyser is the perfect tool for glau-
coma screening and management, enabling eye care professionals
to detect and monitor glaucoma progression.

We know that when screening for disease, the two statistics


determining performance are sensitivity and specificity. We also Top 3 benefits
know that a screening test needs to be conducted as quickly as for your practice
possible, for the benefit of your practice and your patient. Until x Small footprint
now, these factors have been interdependent. For example, x High speed
quicker testing has been achieved but at the expense of accuracy. x High specificity
Or increased accuracy has limited speed. Now we have the
Henson 9000 that does all three.
New ZATA threshold algorithm conforms to
Goldmann standard

Faster threshold testing using prior data for


greater accuracy

Uses variable terminating criteria to further


reduce test times especially in normal and
severely damaged eyes

Fast single and multiple stimulus supra


threshold programme

Numerous PC configuration options

Fully compatible with Henson 8000

Fully compliant DVLA Estermann test

Optional motorised chin rest controlled by PC

PDF format printouts available

Low maintenance costs

68 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
M’EYE E.STORE

6. Local products
OPTOMETRIC ACCESSORIES Discover our wide
range of accessories on
meyestore.com
Solutions for accurate and precise visual assessment.

TRIAL FRAMES & TRIAL CASES PRISMS

RETINOSCOPES & OPTHALMOSCOPES QUICKSEE


- PORTABLE AUTOREFRACTOMETER

STEREO & ISHIHARA TESTS PORTABLE SLIT LAMP

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 69
6. Local products

DIRECT OPHTHALMOSCOPES

A combination of optical perfection, superb ergonomics and versatile features make Keeler direct
ophthalmoscopes the ideal choice. Whatever your requirement from basic examination to detailed
diagnosis, there is a Keeler ophthalmoscope for you.

DIRECT OPHTHALMOSCOPES OPHTHALMIC DIAGNOSTIC SETS

x Specialist Ophthalmoscope x Specialist Ophthalmoscope and Streak


x Professional Ophthalmoscope Retinoscope Set
x Practitioner Ophthalmoscope x Specialist Ophthalmoscope and Spot
x Standard Ophthalmoscope Retinoscope Set
x Professional Ophthalmoscope and Streak
Retinoscope Set
x Professional Ophthalmoscope and Spot
Retinoscope Set

Ask your local Essilor Instrument department for more information about Keeler products.

70 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
ESSILOR TOTAL

6. Local products
MORE THAN PRODUCTS

Essilor Total is our renting solution for you as an Eye Care


Professional. It offers you everything you need to successfully
run your practice: technical products, service, free software
update (remote), one monthly fee and 5 years guarantee.

x Instruments
x Service
x Free software update (remote)
x Insurance
x 5 years guarantee

We offer flexible rental solutions through our financing partner.


Please contact your local Essilor Instrument department for more
information.

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 71
NOTES

72 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
NOTES

We reserve the right to make printing errors and local variations in the product portfolio. | Essilor 73
NOTES

74 Essilor | We reserve the right to make printing errors and local variations in the product portfolio.
For more information please contact your local
Essilor Instruments department

You might also like