Delrin 500P NC010 (White)
Delrin 500P NC010 (White)
Delrin® acetal resin typically is used in demanding applications in the automotive, domestic appliances, sports, industrial engineering, electronics, and consumer goods industries.
Delrin® 500P is a general purpose medium viscosity acetal homopolymer for injection molding. It has improved processing thermal
stability, a good combination of mechanical properties, and low VOC emissions.
General information Value Unit Test Standard
Resin Identification POM - ISO 1043
Part Marking Code POM - ISO 11469
Rheological properties Value Unit Test Standard
Melt volume-flow rate 13 cm³/10min ISO 1133
Temperature 190 °C ISO 1133
Load 2.16 kg ISO 1133
Melt mass-flow rate 15 g/10min ISO 1133
Melt mass-flow rate, Temperature 190 °C ISO 1133
Melt mass-flow rate, Load 2.16 kg ISO 1133
Molding shrinkage, parallel 2.0 % ISO 294-4, 2577
Molding shrinkage, normal 1.9 % ISO 294-4, 2577
Mechanical properties Value Unit Test Standard
Tensile Modulus 3100 MPa ISO 527-1/-2
Yield stress 70.5 MPa ISO 527-1/-2
Yield strain 17 % ISO 527-1/-2
Nominal strain at break 30 % ISO 527-1/-2
Flexural Modulus 3000 MPa ISO 178
Flexural Stress at 3.5% 80 MPa ISO 178
Tensile creep modulus ISO 899-1
1h 2800 MPa
1000h 1600 MPa
Charpy impact strength ISO 179/1eU
73°F 320 kJ/m²
-22°F 280 kJ/m²
Charpy notched impact strength ISO 179/1eA
73°F 9 kJ/m²
-22°F 8 kJ/m²
Puncture - maximum force, 73°F 2000 N ISO 6603-2
Puncture energy, 73°F 3 J ISO 6603-2
Izod notched impact strength ISO 180/1A
73°F 9 kJ/m²
-22°F 8 kJ/m²
Izod impact strength ISO 180/1U
73°F 280 kJ/m²
-22°F 250 kJ/m²
Ball indentation hardness, H 358/30 192 MPa ISO 2039-1
Ball indentation hardness, H 961/30 170 MPa ISO 2039-1
Hardness, Rockwell, M-scale 92 - ISO 2039-2
Hardness, Rockwell, R-scale 120 - ISO 2039-2
Thermal properties Value Unit Test Standard
Melting temperature, 18°F/min 178 °C ISO 11357-1/-3
Characteristics
Processing Injection Molding
Delivery form Pellets
Additives Lubricants Release agent
North America Asia Pacific Near East/Africa
Regional Availability
Europe South and Central America Global
Processing Texts
Injection molding
Drying is recommended, but not necessary for newly opened packaging stored in a dry location.
Diagrams
Viscosity-shear rate
1E3 200 °C
215 °C
230 °C
Viscosity in Pa s
1E2
1E1
1E2 1E3 1E4
Shearstress-shear rate
1E6 200 °C
215 °C
230 °C
Shearstress in Pa
1E5
1E4
1E2 1E3 1E4
1E4
Shear modulus in MPa
1E3
1E2
-50 0 50 100 150
Temperature in °C
Stress-strain
100 Y -40 °C
-20 °C
0 °C
Y 23 °C
40 °C
60 °C
80 Y 90 °C
120 °C
Y Y - Yield
60
Stress in MPa
40
Y
Y
20
0
0 5 10 15 20
Strain in %
Secant modulus-strain
5000 -40 °C
-20 °C
0 °C
23 °C
40 °C
60 °C
4000 90 °C
120 °C
Y - Yield
Secant modulus in MPa
3000
2000
1000
Y
Y Y YY
Y Y
0
0 5 10 15 20
Strain in %
20 1 h
10 h
100 h
1000 h
10000 h
100000 h
15
Stress in MPa
10
0
0 0.5 1 1.5 2
Strain in %
3500 1 MPa
2 MPa
3 MPa
4 MPa
3000 5 MPa
6 MPa
Creep modulus in MPa
2500
2000
1500
1000
500
1E0 1E1 1E2 1E3 1E4 1E5
Time in h
0.8
0.75
0.7
0.65
0 50 100 150 200 250
Temperature in °C
Tensile modulus-temperature
1E4
Tensile modulus in MPa
1E3
1E2
-50 0 50 100 150
Temperature in °C
250 250
200 200
CLTEn in E-6/K
CLTEp in E-6/K
150 150
100 100
-50 0 50 100 150
Temperature in °C
Acids
Acetic Acid (5% by mass) (23°C)
Citric Acid solution (10% by mass) (23°C)
Lactic Acid (10% by mass) (23°C)
Hydrochloric Acid (36% by mass) (23°C)
Nitric Acid (40% by mass) (23°C)
Sulfuric Acid (38% by mass) (23°C)
Sulfuric Acid (5% by mass) (23°C)
Chromic Acid solution (40% by mass) (23°C)
Bases
Sodium Hydroxide solution (35% by mass) (23°C)
Sodium Hydroxide solution (1% by mass) (23°C)
Ammonium Hydroxide solution (10% by mass) (23°C)
Alcohols
Isopropyl alcohol (23°C)
Methanol (23°C)
Ethanol (23°C)
Hydrocarbons
n-Hexane (23°C)
Toluene (23°C)
iso-Octane (23°C)
Ketones
Acetone (23°C)
Ethers
Diethyl ether (23°C)
Mineral oils
SAE 10W40 multigrade motor oil (23°C)
SAE 10W40 multigrade motor oil (130°C)
SAE 80/90 hypoid-gear oil (130°C)
Insulating Oil (23°C)
Standard Fuels
ISO 1817 Liquid 1 - E5 (60°C)
ISO 1817 Liquid 2 - M15E4 (60°C)
ISO 1817 Liquid 3 - M3E7 (60°C)
ISO 1817 Liquid 4 - M15 (60°C)
Standard fuel without alcohol (pref. ISO 1817 Liquid C) (23°C)
Standard fuel with alcohol (pref. ISO 1817 Liquid 4) (23°C)
Salt solutions
Sodium Chloride solution (10% by mass) (23°C)
Sodium Hypochlorite solution (10% by mass) (23°C)
Sodium Carbonate solution (20% by mass) (23°C)
Sodium Carbonate solution (2% by mass) (23°C)
Zinc Chloride solution (50% by mass) (23°C)
Other
Ethyl Acetate (23°C)
Hydrogen peroxide (23°C)
DOT No. 4 Brake fluid (130°C)
Ethylene Glycol (50% by mass) in water (108°C)
1% nonylphenoxy-polyethyleneoxy ethanol in water (23°C)
50% Oleic acid + 50% Olive Oil (23°C)
Water (23°C)
Water (90°C)
Phenol solution (5% by mass) (23°C)
Symbols used:
possibly resistant
Defined as: Supplier has sufficient indication that contact with chemical can be potentially accepted under the intended use conditions and
expected service life. Criteria for assessment have to be indicated (e.g. surface aspect, volume change, property change).
Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.
ISO Mechanical properties measured at 160 mil (Hytrel® measured at 80 mil), IEC Electrical properties measured at 80 mil, all ASTM properties
measured at 120 mil, and test temperatures are 73°F unless otherwise stated.
The information set forth herein is furnished free of charge and is based on technical data that DuPont believes to be reliable and falls within
the normal range of properties. It is intended for use by persons having technical skill, at their own discretion and risk. This data should not be
used to establish specification limits nor used alone as the basis of design. Handling precaution information is given with the understanding that
those using it will satisfy themselves that their particular conditions of use present no health or safety hazards. Since conditions of product use
and disposal are outside our control, we make no warranties, express or implied, and assume no liability in connection with any use of this
information. As with any product, evaluation under end-use conditions prior to specification is essential. Nothing herein is to be taken as a
license to operate or a recommendation to infringe on patents. Caution: Do not use in medical applications involving permanent implantation in
the human body. For other medical applications, discuss with your DuPont customer representative and read Medical Caution H-50103-5.
Copyright © 2017 DuPont or its affiliates. All Rights Reserved. The DuPont Oval Logo, DuPont™, The miracles of science™ and all products
denoted with ® or ™ are registered trademarks or trademarks of E.I. du Pont de Nemours and Company or its affiliates.