Diagram Reference
1 Components and Beeps
E.G
Alarm Keypad
Indicator
Solid Green: No Zone Fault in Operation Mode
Set Solid Red: Zone Fault in Operation Mode
Product Information Flashed Green: Not in the Operation Mode
Fault Solid Orange: System Fault Off: No Fault
COPYRIGHT ©2018 Hangzhou Hikvision Digital Technology Solid Green: All Enabled Channels Connected Normally
Co., Ltd. Network Off: Part of or All Enabled Channels Connected Abnormally
ALL RIGHTS RESERVED.
Armed/Disarmed Solid Blue: Armed Off: Disarmed
1 2 3 4 5
Any and all information, including, among others, wordings,
pictures, graphs are the properties of Hangzhou Hikvision Alarm Flashed Red: Alarm Occurred
Digital Technology Co., Ltd. or its subsidiaries (hereinafter Solid Red: Tamper Alarm Off: No Alarm
referred to be “Hikvision”). This user manual (hereinafter Key low high
referred to be “the Manual”) cannot be reproduced, Query Project Bypass Scoll Up
changed, translated, or distributed, partially or wholly, by
One-Push Scoll Down
any means, without the prior written permission of Fire Panic to Arm
BIN=00111
Hikvision. Unless otherwise stipulated, Hikvision does not Beeps
make any warranties, guarantees or representations, One Beep Pressing keys/command timed out or too long.
express or implied, regarding to the Manual. Two Beeps Successful operation/Report uploaded.
About this Manual Five Beeps Failed operation/Failed to upload the report in 60s.
This Manual is applicable to Alarm Keypad. Continuous Beeping For Two Seconds Fault Prompt.
The Manual includes instructions for using and managing
the product. Pictures, charts, images and all other
Slowly Continuous Beeps
Rapidly Continuous Beeps
Rapid Beeps
Entry/Exit Delay, more than 10s.
Entry/Exit Delay, less than 10s. DEC=7
information hereinafter are for description and explanation Zone Alarm/keypad not registered.
only. The information contained in the Manual is subject to Three Long Beeps and Two Short Beeps Keypad tampered.
change, without notice, due to firmware updates or other Three Beeps Keypad registered.
reasons. Please find the latest version in the company
website (http://overseas.hikvision.com/en/).
2 Keypad Address Settings
Configure the address via DIP switch of the keypad before powering
ADD=7
Please use this user manual under the guidance of on the system. The address should be in the range of 0 to 31. The
professionals. binary value shown in the diagram is 00111, which means the decimal
Trademarks Acknowledgement and other value is 7. So the address of the keypad is 7.
Hikvision’s trademarks and logos are the properties of 3 Keypad Wiring and Installation 3
Hikvision in various jurisdictions. Other trademarks and a. Dimension
logos mentioned below are the properties of their
respective owners.
b. Disassemble the keypad
Loosen the screw, and pry the gap of the edge with a straight screw a 164.13 mm 30.96 mm 11 mm b
driver to disassemble the keypad. Remove the rear panel.
This product and - if applicable - the supplied c. Wiring 5- 3.7
accessories too are marked with "CE" and comply Route the cables through the cable hole of the rear panel, and connect
therefore with the applicable harmonized European the cables to the corresponding terminals.
standards listed under the RE Directive 2014/53/EU, If you need to route the bottom of The keypad functions vary
the panel, remove the sheet of the depending on the model of

6.5 mm
the EMC Directive 2014/30/EU, the RoHS Directive

124.11 mm
side opening. device.

76 mm
2011/65/EU. d. Install Keypad
The Input voltage should meet both the SELV (Safety 1. Secure the mounting plate on the gang box/wall with supplied
Extra Low Voltage) and the Limited Power Source screws. It is required to insert the screw for tamper alarm.
according to the IEC60950-1 standard. Please refer 2. Fasten the keypad body on the plate.
3. Tighten the screw on the buttom to fix the keypad on the mounting
to technical specifications for detailed information. plate and complete the installation.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as unsorted 4 Keypad Operation Commands
municipal waste in the European Union. For proper Function Description Command
recycling, return this product to your local supplier 90 mm
Programming/ Control Panel Programming 【Installer Password】【*】【0】【#】
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For Editing Password Exit Operation 【*】【#】

more information see: www.recyclethis.info


Legal Disclaimer Administrator Password
【Administrator(Operator 001) Password】【*】【0】【#】
【User No. (3digits)】【#】
【New Password】【#】
c d GANGBOX MOUNTING

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, 【New Password】【#】

THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE


Testing 【Installer Password】【*】【6】【0】【#】
2.2K
Control Panel
Exiting Testing 【Installer Password】【*】【6】【2】【#】
AND FIRMWARE, IS PROVIDED “AS IS”, WITH ALL FAULTS AND Testing Alarm Center Testing 【Password】【*】【6】【1】【#】 EOL
D- D+ 12V GND
ERRORS, AND HIKVISION MAKES NO WARRANTIES, EXPRESS Project Mode 【Password】【Project】【9】【0】【n】【#】
Exiting Project Mode 【*】【#】 N.O
OR IMPLIED, INCLUDING WITHOUT LIMITATION, Normal (Away) Arming
【Password】【#】
MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A Arming/Disarming
/Disarming
Instant Arming 【Password】【*】【7】【#】
PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD Stay Arming 【Password】【*】【4】【#】
N.C
PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS, Clearing Alarm
Clearing Under Arming
【Password】【*】【1】【#】
Status
OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU FOR Add Keyfob 【Password】【*】【9】【1】【Keyfob No.】【sub-system No.】【#】
ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT Delete Appointed Keyfob 【Password】【*】【9】【0】【Keyfob No.】【#】
Keyfob
DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR or【Password】【*】【9】【0】【#】+ press the keyfob
Delete All Keyfobs 【Password】【*】【9】【2】【#】
LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR 【Password】【Bypass】【n】【n】【n】【#】 NO/ COM
LOSS OF DATA OR Bypass Bypass Zone(n) 【Bypass】【n】【n】【n】【#】 Z1 GND Z2 D- D+ 12V GND
nnn is the zone No. NC
DOCUMENTATION, IN CONNECTION WITH THE USE OF THIS Enabling/Disabling Keypad
【*】【5】【1】【#】
PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE
3
Tone
Enabling/Disabling Fault
POSSIBILITY OF SUCH DAMAGES. 【*】【5】【6】【#】

REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE


Keypad Settings Prompt
【*】【5】【2】【n】【n】【n】【#】
WALL MOUNTING
LCD Backlight Control
nnn is LCD bright duration.
USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS. LCD Backlight Disabling 【*】【8】【#】
HIKVISION SHALL NOT TAKE ANY RESPONSIBILITES FOR
ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER Specification
DAMAGES RESULTING FROM CYBER ATTACK, HACKER
DS-PK-L DS-PK-LR DS-PK-LRT DS-PK-LRTE
ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY Numeric Key 12 keys: 0 to 9,*,#
RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY Function Key 8 keys: Project/Query/Bypass/On-push to arm/Fire/Panic/Scroll Up/Scroll Down
Indicator Fault (Orange), Network (Green), Alarm (Red), Armed/Disarmed (Blue),Set (Red/Green Dual Color)
TECHNICAL SUPPORT IF REQUIRED. Screen LCD
SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK Input N/A N/A N/A 2 Alarm Inputs
Output N/A N/A N/A 1 Relay Output
ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING Keyfob N/A Two-Way Keyfob Two-way Keyfob Two-way Keyfob

THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE Card Reading


Tamper Switch
N/A N/A
1
Supported Supported

CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE RS-485 Interface 1


Current & Power 12 VDC/ 0.15 A
LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH Consumption 1.8 W
ILLEGITIMATE PURPOSES. Operation
-10 ℃ to+55 ℃
Temperature
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL Operation Humidity 10% to 90%
Weight 272 g (0.60 lb)