0% found this document useful (0 votes)
435 views207 pages

Motorized Volume Control Damper - Mar Rev.01

Uploaded by

arun kurlan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
435 views207 pages

Motorized Volume Control Damper - Mar Rev.01

Uploaded by

arun kurlan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 207

PROJECT

Design & Construction of New Light Industrial Unit-City Neon at Ras Bu Fontas Free Zone

CLIENT
M/s. Qatar Free Zone Authority

CONSULTANT
M/s. Al Khaleej & Industrial Consultancy (KEIC)

MAIN CONTRACTOR
M/s. Amana Contracting

MEP CONTRACTOR
M/s. Q-Tec Engineering W.L.L.

MADE IN QATAR FACTORY


SUBMITTAL FOR SAFID QATAR MAKE MOTORIZED VOLUME
CONTROL DAMPERS

BRAND
SAFID

SUPPLIER
GULF FACILITIES TRADING & CONTRACTING CO.
Tel: +974 4501152/68, Fax: +974 4607714
PO Box. 24212, Doha, Qatar

QATAR 2022
**************************
The Free Zones Authority of
the State of Qatar

(OCS) Observation and Comment Sheet


Project : Design and Construction of Light Industrial Unit for CITYNEON Document Ref. No : R49-AMA-MAR-AC-0101
Consultant : Al Khaleej engineering and industrial consultancy Rev. No : 00
Contractor : Amana Qatar Contracting
Title & Rev : Motorized Volume Control Damper - SAFID

Reviewed Document / Drawing No.: R49-AMA-MAR-AC-0101 Submittal No. : R49-AMA-MAR-AC-0101 Issued Date : 03 Jan 2023.

QFZA Stamp: Actionee Initials


Assessment Code: A = Approved Prepared by KA
B = Approved with Comments
Reviewed by AG
C
C = Revise & Resubmit
SA
D = Not Approved / Rejected Cleared by
ZH
QFZA / Consultant Contractor - AMANA QFZA
Identification of Sign-Off
S/N Reviewer comment's source: Observations / Comments Document Ref. No. Comments (if any) Code [Open
[doc/part/page/para] Closed]

The proposed brand SAFID is Local manufacturer and


SAFID is not specified in the PVL. Contractor to submit the proposal having approvals in many reputable entities in Qatar
1 KEIC-KA PVL along with a written justification for deviation from the Preferred Vendor R49-AMA-MAR-AC-0101 such as ASHGHAL, Qatar Armed force, Supreme C OPEN
List for the Engineer’s review. Committee, QP, Qatar Rail, KEO etc.
Please find enclosed Approvals for your review.
Provide a readable and clear compliance statement

Comply.
2 KEIC-KA Specification R49-AMA-MAR-AC-0101 C OPEN
Please find enclosed Compliance Statement.

Provide reference drawings for the project with highlight on the areas Comply.
3 KEIC-KA Area of application R49-AMA-MAR-AC-0101 B Open
where the material shall be used. Please find enclosed highlighted drawings.

4 KEIC-KA Size Size of the damper is subject to the approved drawings R49-AMA-MAR-AC-0101 Will be comply. B OPEN

All the delivered dampers shall be labelled. Without labelling the


5 KEIC-KA Labelling R49-AMA-MAR-AC-0101 Will be comply. B Open
material will be rejected
To include the impact of air pressure in the calculation of fans static
6 KEIC-KA ESP R49-AMA-MAR-AC-0101 Will be comply. B Open
pressure
The Motorized Volume Control Damper shall be fully compatible
7 KEIC-KA BMS R49-AMA-MAR-AC-0101 Comply. C OPEN
with future BMS interface and connection.
All installation shall comply with project and authorities
8 KEIC-KA Installation R49-AMA-MAR-AC-0101 Will be comply. B OPEN
requirements and manufacturer recommendations

Page 1 of 2 Base on Template: QFZA-034_V_1_0


The Free Zones Authority of
the State of Qatar

Reviewed Document / Drawing No.: R49-AMA-MAR-AC-0101 Submittal No. : R49-AMA-MAR-AC-0101 Issued Date : 03 Jan 2023.

QFZA Stamp: Actionee Initials


Assessment Code: A = Approved Prepared by KA
B = Approved with Comments
Reviewed by AG
C
C = Revise & Resubmit
SA
D = Not Approved / Rejected Cleared by
ZH
QFZA / Consultant Contractor - AMANA QFZA
Identification of Sign-Off
S/N Reviewer comment's source: Observations / Comments Document Ref. No. Comments (if any) Code [Open
[doc/part/page/para] Closed]

9 KEIC-KA GSAS Provide compliance with GSAS where applicable R49-AMA-MAR-AC-0101 Not Applicable. B OPEN

Detailed method statement to be submit separately. Installation shall be


10 KEIC-KA Method Statement R49-AMA-MAR-AC-0101 Method Statement will be submitted separately. B OPEN
as per project, QCS2014 and supplier recommendations.
As per SOW, Submit Catalogue, sample and Complete Installation Comply.
11 KEIC-KA Sample R49-AMA-MAR-AC-0101 C OPEN
including fixing of Dampers and VCD (PDS, FSS) Sample submitting with this Submittal.
Warranty shall be as project specification and authority
12 KEIC-KA Warranty R49-AMA-MAR-AC-0101 Comply. B OPEN
requirements.
Contractor shall use only one brand in the project. Mixing is not
13 KEIC-KA Mixing R49-AMA-MAR-AC-0101 Noted. NOTE
permitted.
Material availability and the delivery period to be considered as per
14 KEIC-KA Delivery R49-AMA-MAR-AC-0101 Noted. NOTE
project timeline
During material delivery following documents to be attached:
1.Delivery note 2.Country of origin 3.Packing list 4.Bill of lading
15 KEIC-KA R49-AMA-MAR-AC-0101 Noted. NOTE
5.Test certificates 6.Warranty certificate and other applicable
documents as per project requirement
All the relevant certificates should be valid at the time of usage on
16 KEIC-KA R49-AMA-MAR-AC-0101 Noted. NOTE
site and throughout the work.
The approval shall not relieve the contractor from his obligations to
perform the design/installation/testing commissioning in
17 KEIC-KA R49-AMA-MAR-AC-0101 Noted. NOTE
accordance with the contract documents, relevant specifications
and local authority regulations.
The Client reserves his right to withdraw the approval in case of
18 KEIC-KA R49-AMA-MAR-AC-0101 Noted. NOTE
improper performance/deficient quality of works.
Actionee Name Role Ι Designation Signature

Prepared &
Kamal Azayem Sr. Mechanical Engineer
Reviewed by :
Checked by: Anees Gafoor Construction Manager

Checked by: Sharmarke Ali Design Manager

Cleared by : Zuhair Hasanain Project Manager

Page 2 of 2 Base on Template: QFZA-034_V_1_0


1 2 3 4 5 6 7 8 9 10 11 12 13
PROJECT KEY PLAN:
NORTH

01 02 03 04 05 06 TRUE °
66
EAD 700x500 NORTH
T/A
EAD 800x500
T/A
CSU-GF-11 EAD 700x400

107
2-SCD 600x600 T/A

°
EG 500x150
350x350 N.S
L FAD 300x150
150
186 L/s EACH
FAD 900x500
FROM FAHU-GF-01
L
RG 1050x300 FAD 500x500 QUIBLA
FAD 300x150 136 L/S NORMAL MODE FROM TFA-RF-02 CITYNEON-
93 L/S NORMAL MODE EAD 900x500 ANGLE
TO FAHU-GF-01 OFFICE,SHOW
ROOM
500x400 &WORKSHOP
300x150
CSU-GF-07

900x500

900x500
4-SCD 600x600 500x350 300x150 LEGEND:
300x300
EG N.S
450x150 900x300
160 L/s EACH
35 L/s
RG 900x300
VD VD FAD 300x250
229 L/S NORMAL MODE 900x300
K 500x400
SOFT CAST URETHANE PAINT ROOM K
VD
300x250 005 003
400x150 400x150 400x150 MOLD 400x150 900x300
FRP / COMPOSITES SPRAY
500x350 FAD 1400x1000
007 500x250
008 500x200 FROM FAHU-GF-03&03A

400x150 400x150 900x300


MD 250x200
FAD 450x250 VD VD EAD 1400x1000
415 L/S NORMAL MODE TO FAHU-GF-03&03A
VD VD
FAD 700x500 400x150 400x150 SOFT CAST SILICONE
FROM TFA-RF-01
006
J EAD 500x250 MD MD
800x500
J
UP TO EF-RF-01 VD NOTES:
500x250
B 1. SPECIAL VENTILATION EQUIPMENT LOCATIONS ARE
CONSIDERED AS PER REVISED LIST OF EQUIPMENT SHARED,
FAD 750x450
1916 L/S PROCESSING MODE ACCORDINGLY THE TIE IN/STUB OUT CONNECTIONS ARE
FAD 300x150 CLEAN CAST AREA SHOWN IN THE DRAWINGS.
93 L/S NORMAL MODE

550x300
004 2. D&B CONTRACTOR SHALL CO-ORDINATE WITH END USER
FOR THE EXACT LOCATION OF EACH EQUIPMENT AND ITS
400x150

250x250
EXHAUST/VENT CONNECTION.
400x150

PAINT PREP.
C
H VD 028 H
LINE TYPE DIFFERENTIATION
300x300 550x300
D (CONTINUOUS) QFZ
400x150

VD
CSU-GF-08
400x150

4-SCD 600x600
300x300 N.S (HIDDEN) CITYNEON
FRP / COMPOSITES HAND
150 L/s EACH LAYUP
RG 850x300 REFERENCE MODEL:
EG 350x150
009 3229-ECG-MB-ZZ-3DM-A-AA-00001 00
102 L/s
EAD 800x500 OTHER REFERENCES:
750x450 TIE IN

G 250x150 E G

6-SCD 600x600
650x350

400x400 N.S
282 L/s EACH SCULPTING / SCENIC SHOP
2- RG 1250x300
EG 350x150 VD VD
026 SPACE FOR EQUIPMENTS
102 L/s CSU-GF-09
SG 2600x300 500x350 650x350
1916 L/s 027
VD FAD 250x100
450x250 46 L/S NORMAL MODE
F F
450x250 FAD 250x100 STAFF TOILET 01 EAD 300x250 0 5 [m]
1 2 3 4
VD UP TO EF-RF-03
025 200x100 Scale: 1:100
450x250 650x350 CSU-GF-10
FRP / COMPOSITES
PROCESSING 450x250 VD
450x250 300x250
010 VD VD 200x100
200x100
250x200 250x200
VD VD VD 6-EG 150x150

650x350 200x100
250x150 250x150 35 L/s EACH F
VD VD 00 DEC-2022 DESIGN DEVELOPMENT Y.TAHA M.ASAB M.DARM A.MAMR
200x150 200x150
E ODU-GF-01
IDU-GF-03A 200x100 200x100 REV DATE ISSUED FOR DRW CHK TL PM E
MALE VISTITOR'S TOILET
4-EG 150x150
CLIENT:
IDU-GF-03 IDU-GF-03B 35 L/s EACH 4-EG 150x150 019
IDU-GF-01
200x100 35 L/s EACH QATAR FREE ZONES
ODU-GF-03
G AUTHORITY
STAFF TOILET 02 200x100 200x150 200x200 250x200
PROJECT MANAGEMENT:

REF TO 1 / 3229-ECG-MB-GR-DWG-M-HV-01102
ODU-GF-03A IDF ROOM
ELECT. ROOM 026
012
011
ODU-GF-03B LEAD CONSULTANT:
D D
AUTOMATED DOOR

AMANA QATAR CONTRACTING CO. W.L.L


P.O.Box:23377, Doha-Qatar
Tel:+974 44016222, Fax:+97444121543
11-Dec-22 3:14:08 PM

LEAD CONSULTANT:

FD
H ECG
ENGINEERING CONSULTANTS GROUP S.A.

FOR CONTINUATION
C www.ecgsa.com C
FCU-GF-04 FCU-GF-05 FCU-GF-06 FCU-GF-07 PROJECT TITLE:
SCD 600x600 SCD 600x600 SCD 600x600 SCD 600x600
350x350 N.S
207 L/s
350x350 N.S
207 L/s
250x250 N.S
67 L/s
250x250 N.S
67 L/s DESIGN & BUILD OF THE NEW LIGHT
450x200 2-EG 450x150 RG 600x150 RG 600x150 RG 250x150 RG 250x150
INDUSTRIAL UNITS

MATCH LINE
118 L/s EACH
EG 450x250 AT LOW LEVEL
236 L/s
EF-GF-02
300 mm FROM at Ras Bufontas Free Zone PA-WH-08-01
FFL
450x200 AUTOMATED DOOR CITYNEON-OFFICE, SHOWROOM & WORKSHOP
400x150 400x150 300x100 RECIEVING AND DISCIPLINE
VD VD WAREHOUSING
SHEET SIZE - ISO A1 (841* 594 MM)

B 600x100 600x100
018
Mechanical HVAC B
400x150 400x150 300x100 300x100 SHEET TYPE
1.3_MECHANICAL_HVAC WORKS PLANS
I SHEET TITLE
FLAMABLE LIQUID STORAGE MEETING ROOM
(PROTECTED WITH FOAM
MEETING ROOM SCULPT / MOLD SHOP SCENIC SHOP MANAGER GROUND FLOOR PLAN
SYSTEM) 014
015 016 017 SHEET 01 OF 03
013
GROUND FLOOR - DUCT - PART 01 OF 03 SCALE: 1 : 100 SHEET SIZE: A1 SUITABILITY: S4
1 SCALE 1 : 100
Drawing No: Rev:
A 3229-ECG-MB-GR-DWG-M-HV-01101 00 A
1 2 3 4 5 6 7 8 9 10 11 12 13 ECG Copyright - Produced Using BIM Technology
1 2 3 4 5 6 7 8 9 10 11 12 13
PROJECT KEY PLAN:
NORTH

01 02 03 04 05 06 TRUE 66
°
NORTH

EAD 700x400 SAD 900x550


FAD 900x500 FROM PACU-RF-05
EAD 800x500
EAD 900x500 RAD 900x550

107
EAD 700x500 TO PACU-RF-05
FAD 500x500

°
L L
MD FAL 1500x1200 QUIBLA CITYNEON-
FAL 1200x1200
1916 L/s PACU-RF-02 ANGLE
1274 L/s BDD OFFICE,SHOW
FAHU-GF-01 FD FD FD FD
MD ROOM

900x550
700x500
MD TFA-RF-02 EF-RF-04 &WORKSHOP
900x500 SAT VD
SAT 450x150
300x250 LEGEND:
TFA-RF-01 900x500 500x500
450x250

MD FAL 1200x500 500x300 FAD 1400x1000


K BDD RAD 600x600 RAD 800x600 536 L/s PACU-RF-01
MD FROM FAHU-GF-03&03A K
SAD 600x350 SAD 600x550 500x300
FAL 2000x1500 MD SAT 600x350 600x600 800x600 950x600 SAT
EF-RF-01 2690 L/s 600x350 EAD 1400x1000
VD VD SAT TO FAHU-GF-03&03A
FD SAT

900x400
600x350 600x550 450x250
FAD 700x500 VD VD VD VD VD VD
750x600 VD 450x150
VD
EAD 700x400
EAD 250x500 600x350 600x350 600x350 600x350 600x350
600x350 RAD 950x600 600x350
FD 600x350 600x350 600x350 SAD 850x550 600x350 600x350
B
J J

700x400
NOTES:

1. SPECIAL VENTILATION EQUIPMENT LOCATIONS ARE


450x250 CONSIDERED AS PER REVISED LIST OF EQUIPMENT SHARED,
VD
ACCORDINGLY THE TIE IN/STUB OUT CONNECTIONS ARE
450x150 SHOWN IN THE DRAWINGS.
C
2. D&B CONTRACTOR SHALL CO-ORDINATE WITH END USER
FOR THE EXACT LOCATION OF EACH EQUIPMENT AND ITS
EXHAUST/VENT CONNECTION.
D
H H

550x400
LINE TYPE DIFFERENTIATION

(CONTINUOUS) QFZ

450x250 (HIDDEN) CITYNEON


VD
450x150 E REFERENCE MODEL:
3229-ECG-MB-ZZ-3DM-A-AA-00001 00
OTHER REFERENCES:

450x300
G G

F F
0 1 2 3 4 5 [m]

Scale: 1:100

F
300x150

00 DEC-2022 DESIGN DEVELOPMENT Y.TAHA M.ASAB M.DARM A.MAMR


600x300
E REV DATE ISSUED FOR DRW CHK TL PM E
G CLIENT:

REF TO 1 / 3229-ECG-MB-02-DWG-M-HV-01102
QATAR FREE ZONES
AUTHORITY
PROJECT MANAGEMENT:

LEAD CONSULTANT:
D D

AMANA QATAR CONTRACTING CO. W.L.L


H P.O.Box:23377, Doha-Qatar

FOR CONTINUATION
Tel:+974 44016222, Fax:+97444121543
11-Dec-22 3:12:56 PM

LEAD CONSULTANT:

ECG
ENGINEERING CONSULTANTS GROUP

MATCH LINE
S.A.
C www.ecgsa.com C
PROJECT TITLE:

DESIGN & BUILD OF THE NEW LIGHT


INDUSTRIAL UNITS
at Ras Bufontas Free Zone PA-WH-08-01
CITYNEON-OFFICE, SHOWROOM & WORKSHOP
DISCIPLINE
I
SHEET SIZE - ISO A1 (841* 594 MM)

B Mechanical HVAC B
SHEET TYPE
1.3_MECHANICAL_HVAC WORKS PLANS
SHEET TITLE
SECOND FLOOR PLAN
SECOND FLOOR - DUCT - PART 01 OF 03 SHEET 01 OF 03
1 SCALE 1 : 100 SCALE: 1 : 100 SHEET SIZE: A1 SUITABILITY: S4
Drawing No: Rev:
A 3229-ECG-MB-02-DWG-M-HV-01101 00 A
1 2 3 4 5 6 7 8 9 10 11 12 13 ECG Copyright - Produced Using BIM Technology
1 2 3 4 5 6 7 8 9 10 11 12 13
PROJECT KEY PLAN:
NORTH

TRUE °
66
NORTH

01 02 03 04 05 06

107
°
L L
QUIBLA CITYNEON-
SAD 900x550 ANGLE OFFICE,SHOW
RAD 900x550 ROOM
&WORKSHOP

LEGEND:
FD FD
900x550
900x550 500x200
SAT SAT
K K
FD

FAD 1400x1000

EAD 1400x1000

FD

J J
NOTES:

B 1. SPECIAL VENTILATION EQUIPMENT LOCATIONS ARE


CONSIDERED AS PER REVISED LIST OF EQUIPMENT SHARED,
CU-RF-02 ACCORDINGLY THE TIE IN/STUB OUT CONNECTIONS ARE
SHOWN IN THE DRAWINGS.

2. D&B CONTRACTOR SHALL CO-ORDINATE WITH END USER


FOR THE EXACT LOCATION OF EACH EQUIPMENT AND ITS
EXHAUST/VENT CONNECTION.

H C LINE TYPE DIFFERENTIATION


H

(CONTINUOUS) QFZ
D
(HIDDEN) CITYNEON

VRF-GF-03 REFERENCE MODEL:


3229-ECG-MB-ZZ-3DM-A-AA-00001 00
OTHER REFERENCES:
VRF-GF-02
G E G

PACU-RF-04

F F
0 1 2 3 4 5 [m]

Scale: 1:100
FAL 400x400
536 L/s
SAT

300x200
MD

750x650
F 00 DEC-2022 DESIGN DEVELOPMENT Y.TAHA M.ASAB M.DARM A.MAMR
E 800x500 REV DATE ISSUED FOR DRW CHK TL PM E
CLIENT:
VD

600x300 QATAR FREE ZONES


AUTHORITY
G
PROJECT MANAGEMENT:

REF TO 1 / 3229-ECG-MB-RF-DWG-M-HV-01102
LEAD CONSULTANT:
D D

AMANA QATAR CONTRACTING CO. W.L.L


P.O.Box:23377, Doha-Qatar
Tel:+974 44016222, Fax:+97444121543
MSFD
11-Dec-22 3:15:13 PM

LEAD CONSULTANT:

SEF-RF-01
H ECG
ENGINEERING CONSULTANTS GROUP S.A.
C C

FOR CONTINUATION
www.ecgsa.com
PROJECT TITLE:

DESIGN & BUILD OF THE NEW LIGHT


INDUSTRIAL UNITS

MATCH LINE
at Ras Bufontas Free Zone PA-WH-08-01
CITYNEON-OFFICE, SHOWROOM & WORKSHOP
DISCIPLINE
SHEET SIZE - ISO A1 (841* 594 MM)

B Mechanical HVAC B
SHEET TYPE
1.3_MECHANICAL_HVAC WORKS PLANS
SHEET TITLE
I
ROOF FLOOR PLAN
SHEET 01 OF 03
ROOF FLOOR - DUCT - PART 01 OF 03 SCALE: 1 : 100 SHEET SIZE: A1 SUITABILITY: S4
1 SCALE 1 : 100 Drawing No: Rev:
A 3229-ECG-MB-RF-DWG-M-HV-01101 00 A
1 2 3 4 5 6 7 8 9 10 11 12 13 ECG Copyright - Produced Using BIM Technology
1 2 3 4 5 6 7 8 9 10 11 12 13
PROJECT KEY PLAN:
NORTH
07 08 09 10 11 12 13 14 14'
TRUE °
66
NORTH

SAD 900x550
RAD 900x550

107
RAD 900x550

°
L L
QUIBLA CITYNEON-
FAL 800x450 FAL 800x450 ANGLE OFFICE,SHOW
322 L/s 322 L/s VRF-GF-01 VRF-FF-01 VRF-SF-01 CU-GF-04
ROOM
FD FD FD &WORKSHOP
PACU-RF-05 PACU-RF-06
500x200 MD 500x200
SAT SAT MD
LEGEND:

SAT SAT

K K

TOP

FD MD
FAD 1400x1000 EAD 450x300 450x300
FAD 650x400
650x400
FAL 900x500
FD 417 L/s FAHU-GF-02
EAD 1400x1000

SAT B
J SAT
SAT
J
CU-RF-02
NOTES:

1. SPECIAL VENTILATION EQUIPMENT LOCATIONS ARE

M4

M4
CONSIDERED AS PER REVISED LIST OF EQUIPMENT SHARED,
PACU-RF-03 ACCORDINGLY THE TIE IN/STUB OUT CONNECTIONS ARE
SHOWN IN THE DRAWINGS.

M3

M3
ODU-SF-01A ODU-SF-01B ODU-SF-02A ODU-FF-01 ODU-SF-04
C

1300x750
M2

M2
SAT 2. D&B CONTRACTOR SHALL CO-ORDINATE WITH END USER
FAHU-GF-03 FAHU-GF-03A
FOR THE EXACT LOCATION OF EACH EQUIPMENT AND ITS
600x550 900x650 900x650 EXHAUST/VENT CONNECTION.
D
H H

1250x700
M1
VD

M1
VD
LINE TYPE DIFFERENTIATION
600x350 600x600 850x600 850x600 600x600
M6

M6
CU-RF-01 CU-RF-05 VD
(CONTINUOUS) QFZ
VD VD
EAL 1500x1800 600x550
5286 L/s 600x350 600x550 600x350 600x350 (HIDDEN) CITYNEON
VRF-GF-02 600x350 600x550

E REFERENCE MODEL:
1400x1000 3229-ECG-MB-ZZ-3DM-A-AA-00001 00
MD
BDD 950x800 OTHER REFERENCES:

FAL 2500x2000
G 5286 L/s 1400x1000 G
PACU-RF-04

950x800
950x800 CU-GF-03 CU-GF-03A

EAL 1500x1800
5286 L/s

FAL 400x400
F 536 L/s F
0 1 2 3 4 5 [m]
SEF-RF-04
300x200
MD Scale: 1:100

750x650 700x650 700x400 MSFD


F
800x500 600x500 600x300
BDD
VD VD VD
EF-RF-04

600x300 700x400 600x300 700x400 FD 00 DEC-2022 DESIGN DEVELOPMENT Y.TAHA M.ASAB M.DARM A.MAMR
E EAD 500x250 REV DATE ISSUED FOR DRW CHK TL PM E
CLIENT:
G
QATAR FREE ZONES

REF TO 1 / 3229-ECG-MB-RF-DWG-M-HV-01103
AUTHORITY
REF TO 1 / 3229-ECG-MB-RF-DWG-M-HV-01101

PROJECT MANAGEMENT:

LEAD CONSULTANT:
D D
MSFD MSFD MSFD MSFD

SEF-RF-03
AMANA QATAR CONTRACTING CO. W.L.L
SEF-RF-01 SEF-RF-02 SEF-RF-05
H P.O.Box:23377, Doha-Qatar
Tel:+974 44016222, Fax:+97444121543
11-Dec-22 3:15:24 PM

LEAD CONSULTANT:

FOR CONTINUATION
ECG
FOR CONTINUATION

ENGINEERING CONSULTANTS GROUP S.A.


C www.ecgsa.com C
PROJECT TITLE:

MATCH LINE
MATCH LINE

DESIGN & BUILD OF THE NEW LIGHT


INDUSTRIAL UNITS
at Ras Bufontas Free Zone PA-WH-08-01
CITYNEON-OFFICE, SHOWROOM & WORKSHOP
DISCIPLINE
SHEET SIZE - ISO A1 (841* 594 MM)

B I Mechanical HVAC B
SHEET TYPE
1.3_MECHANICAL_HVAC WORKS PLANS
SHEET TITLE
ROOF FLOOR PLAN
ROOF FLOOR - DUCT - PART 02 OF 03 SHEET 02 OF 03
1 SCALE 1 : 100 SCALE: 1 : 100 SHEET SIZE: A1 SUITABILITY: S4
Drawing No: Rev:
A 3229-ECG-MB-RF-DWG-M-HV-01102 00 A
1 2 3 4 5 6 7 8 9 10 11 12 13 ECG Copyright - Produced Using BIM Technology
1 2 3 4 5 6 7 8 9 10 11 12 13
PROJECT KEY PLAN:
NORTH

14' 15 16 17 18 19 20 TRUE
NORTH
66
°

EAD 400x250 SAD 1500x700


EAD 400x250

107
RAD 1500x700 SAD 1500x700
EAD 250x250

°
RAD 1500x700
L L
QUIBLA CITYNEON-
ANGLE OFFICE,SHOW
ROOM
EAD 450x300 &WORKSHOP
CU-GF-04 FD FD EAD 450x300
EF-RF-07
FD FD FD FD FD LEGEND:
BDD SAT SAT SAT 450x300

K K
EAD 400x400 SAT
1500x700
EAD 150x150 ODU-GF-06 1500x700 1500x700 1500x700

EAD 400x400 450x200 450x200


TOP
FAD 650x400 FD MD MD
MD EAD 700x400 PACU-RF-07 PACU-RF-10
FD

FAL 700x400 FAL 700x400


BDD EF-RF-06 286 L/s 286 L/s

FAHU-GF-02 BDD
EAL 1200x550
J 1259 L/s J
B NOTES:
FAL 1800x800
1361 L/s 1. SPECIAL VENTILATION EQUIPMENT LOCATIONS ARE
FAL 1200x550
CONSIDERED AS PER REVISED LIST OF EQUIPMENT SHARED,
MD FAL 1000x550
361 L/s PACU-RF-08 PACU-RF-09 ACCORDINGLY THE TIE IN/STUB OUT CONNECTIONS ARE
MD 493 L/s
SHOWN IN THE DRAWINGS.
PACU-RF-03 500x250
2. D&B CONTRACTOR SHALL CO-ORDINATE WITH END USER
350x350
SAT
SAT
C FOR THE EXACT LOCATION OF EACH EQUIPMENT AND ITS
EXHAUST/VENT CONNECTION.
VD
H 600x550
VD SAT H
LINE TYPE DIFFERENTIATION
1050x600 850x600 650x600 650x350
RAD 900x500 D
VD SAD 900x500
VD (CONTINUOUS) QFZ
FD
600x600 600x350 VD VD

VD RAD 900x500 (HIDDEN) CITYNEON


VD 650x350 700x700
600x550 600x350 600x350 650x350 650x350
650x350 650x350 REFERENCE MODEL:
600x550 700x700 SAD 900x500
700x400 3229-ECG-MB-ZZ-3DM-A-AA-00001 00
FD
E OTHER REFERENCES:

G G

F F
0 1 2 3 4 5 [m]

Scale: 1:100
SEF-RF-06 SEF-RF-08 SEF-RF-10

MSFD MSFD MSFD


F
00 DEC-2022 DESIGN DEVELOPMENT Y.TAHA M.ASAB M.DARM A.MAMR
E REV DATE ISSUED FOR DRW CHK TL PM E
CLIENT:

G QATAR FREE ZONES


REF TO 1 / 3229-ECG-MB-RF-DWG-M-HV-01102

AUTHORITY
PROJECT MANAGEMENT:

LEAD CONSULTANT:
D D
SEF-RF-09
SEF-RF-07

MSFD MSFD AMANA QATAR CONTRACTING CO. W.L.L


P.O.Box:23377, Doha-Qatar
Tel:+974 44016222, Fax:+97444121543
11-Dec-22 3:15:39 PM

H LEAD CONSULTANT:

ECG
FOR CONTINUATION

ENGINEERING CONSULTANTS GROUP S.A.


C www.ecgsa.com C
PROJECT TITLE:
MATCH LINE

DESIGN & BUILD OF THE NEW LIGHT


INDUSTRIAL UNITS
at Ras Bufontas Free Zone PA-WH-08-01
CITYNEON-OFFICE, SHOWROOM & WORKSHOP
DISCIPLINE
SHEET SIZE - ISO A1 (841* 594 MM)

B Mechanical HVAC B
SHEET TYPE
I 1.3_MECHANICAL_HVAC WORKS PLANS
SHEET TITLE
ROOF FLOOR PLAN
SHEET 03 OF 03
ROOF FLOOR - DUCT - PART 03 OF 03 SCALE: 1 : 100 SHEET SIZE: A1 SUITABILITY: S4
1 SCALE 1 : 100 Drawing No: Rev:
A 3229-ECG-MB-RF-DWG-M-HV-01103 00 A
1 2 3 4 5 6 7 8 9 10 11 12 13 ECG Copyright - Produced Using BIM Technology
1 2 3 4 5 6 7 8 9 10 11 12 13
KEY PLAN:

1 2 3 4 PROJECT
NORTH

TRUE
SAD 500x250 SAD 500x250 24° NORTH
450 L/s 450 L/s
L SAD 500x250 SAD 500x250 10
7 ° SUBSTATION L
407 L/s 450 L/s
SAD 400x250 QUIBLA
299 L/s ANGLE

A A
LEGEND:

K K
SG 700x250 3- SG 700x250 SG 450x250
407 L/s 450 L/s EACH 299 L/s
RG 700x250 3-RG 700x250 RG 450x250

J J
B B NOTES:

RAD 500x250 RAD 500x250


373 L/s 438 L/s RAD 400x250
232 L/s
RAD 500x250 RAD 500x250
438 L/s 438 L/s

H H
1 2 3 4

REFERENCE MODEL:
Ground Floor Level 3229-ECG-SB-ZZ-3DM-A-AA-00001
OTHER REFERENCES:
00

1 1 : 100
G G

1 2 3 4
F F
0 1 2 3 4 5 [m]

SAD 500x250 SAD 500x250 Scale: 1:100


450 L/s 450 L/s
SAD 500x250 SAD 500x250 SAD 400x250
407 L/s 450 L/s 299 L/s

A VD VD VD
VD 400x250 A 00 DEC-2022 DESIGN DEVELOPMENT Y.TAHA M.ASAB M.DARM A.MAMR
E 500x250 750x450
REV DATE ISSUED FOR DRW CHK TL PM E
CLIENT:

PACU-RF-01 QATAR FREE ZONES


MD MD SAD 750x500 AUTHORITY
SAD 900x400
RAD 900x400 RAD 850x500 PROJECT MANAGEMENT:
MD MD

PACU-RF-01A
LEAD CONSULTANT:
D MD
FAL 500x300 D
SAD 900x400
RAD 900x400 VD 137 L/s
VD
500x250 850x450

VD 400x250 AMANA QATAR CONTRACTING CO. W.L.L


B VD VD
B P.O.Box:23377, Doha-Qatar
Tel:+974 44016222, Fax:+97444121543
11-Dec-22 3:32:37 PM

LEAD CONSULTANT:
RAD 500x250
373 L/s
RAD 500x250
RAD 500x250
438 L/s
RAD 500x250
RAD 400x250
232 L/s ECG
ENGINEERING CONSULTANTS GROUP S.A.
C 438 L/s 438 L/s
www.ecgsa.com C
PROJECT TITLE:

DESIGN & BUILD OF THE NEW LIGHT


1 2 3 4 INDUSTRIAL UNITS
at Ras Bufontas Free Zone PA-WH-08-01
Roof Floor Level SUBSTATION
2 1 : 100
DISCIPLINE
SHEET SIZE - ISO A1 (841* 594 MM)

B Mechanical HVAC B
SHEET TYPE
1.3_MECHANICAL_HVAC WORKS PLANS
SHEET TITLE
FLOOR PLANS (GROUND FLOOR PLAN, ROOF PLAN)
OVERALL
SCALE: 1 : 100 SHEET SIZE: A1 SUITABILITY: S4
Drawing No: Rev:
A 3229-ECG-SB-ZZ-DWG-M-HV-01001 00 A
1 2 3 4 5 6 7 8 9 10 11 12 13 ECG Copyright - Produced Using BIM Technology
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series
( Flange Type )

SPK 30 - 400 Standard Construction


FRAME:
160mm x 30mm x 1.8mm galvanized steel formed channel
for flange connection.

BLADES:
100mm, 125mm and 150mm wide airfoil shaped blades

FINISH:
Frame of mill galvanized.
Blades of mill galvanized.

EXTERNAL LINKAGE:
Galvanized steel side linkage concealed in frame for opposed
blade operation.

CASE BEARING:
Brass bearing as standard.
Sintered bronze oilite (optional).

CONTROL SHAFT:
Description 12mm diameter zinc plated mild steel.
SPK 30-400 Class 1A & Class 1 Low Leakage Volume Control
Dampers are recommended for use in multiple Air Conditioning Units TIP SEAL
with one common air duct system on which one or two A/C Units Bubble type seal.
needs to be isolated during standby mode while the other A/C Unit is For Alr Leakage "Class 1A" and "Class 1".
on operational mode.
SIDE SEAL (Jamb Seal):
In building pressurization it can be used as an isolation damper to
maintain the required pressure in the space. Compression type stainless steel grade 304 to close
gap between frame and blades.
In office buildings where some occupants are outside most of the
time, this type of damper is recommended to shutdown the flow of air
MINIMUM & MAXIMUM SINGLE SECTION SIZE:
when the space is unoccupied on which can save energy
consumption.
100 x 100mm minimum and 900 x 900mm maximum.

It is also being used as a fresh air intake damper for Air Conditioning
Units where it needs a fresh air damper to be closed upon detection
of heavy dust on the fresh air side.
SPK 30 - 410
The blades with airfoil construction provides a low pressure drop in
the open position for smooth airflow and reduced air turbulence.
General construction as type SPK 30-400 damper but with
frame, linkage, case bearing, axles and control shaft are from
stainless steel (Grade 304).

SAFID certifies that the Class 1A & Class 1 Low Leakage Volume Control Damper
shown herein is licensed to bear the AMCA Seal for Model SPK 30-400. The ratings
shown are based on tests and procedures performed in accordance with AMCA
Publication 511 and comply with the requirements of the AMCA Certified Ratings
Program.
The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance Ratings.
Test Information
Tested for air leakage in accordance with ANSI / AMCA Standard 500-D-07,
Figure 5.4. Air leakage is based on operation between 32 ºF and 120 ºF.
Tested for air performance in accordance with ANSI / AMCA Standard 500-D-07
(Pressure Drop), Figure 5.3.
Catalog ID: SPK 30-400 January 23, 2014
Only 150mm blade width is AMCA certified.

Right to alterations reserved.

1
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series

Air Leakage Performance

Air Leakage Data

36 in. x 36 in. Allowable Air Leakage


( 914mm x 914mm ) To Achieve Leakage Classification
( Face Area = 9 ft² ) ( cfm/ft² )
Static Pressure Leakage Air Leakage Leakage at 1 in. at 2 in. at 4 in. at 6 in. at 12 in.
( in. W.G. ) ( cfm/ft² ) Classification Class W.G. W.G. W.G. W.G. W.G.
1 2.336 Class 1A 1A 3 N/A N/A N/A N/A
2 3.549 Class 1 1 4 5.6 8 9.8 13.8
4 5.498 Class 1 2 10 14 20 24.5 34.6
6 6.646 Class 1 3 40 56.5 80 98 138.5
12 9.796 Class 1

Data are based on a torque of 24.6 in.-lb/ft2 applied to close and seat the damper during the test.

SAFID certifies that the Class 1A & Class 1 Low Leakage Volume Control Damper shown
herein is licensed to bear the AMCA Seal for Model SPK 30-400. The ratings shown are
based on tests and procedures performed in accordance with AMCA Publication 511 and
comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance Ratings.
Test Information
Tested for air leakage in accordance with ANSI / AMCA Standard 500-D-07,
Figure 5.4. Air leakage is based on operation between 32 ºF and 120 ºF.
Tested for air performance in accordance with ANSI / AMCA Standard 500-D-07
(Pressure Drop), Figure 5.3.
Only 150mm blade width is AMCA certified.
Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

2
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series

Air Performance
Pressure Drop

AMCA Test Figure 5.3

Pressure Drop at Face Area Velocity


Damper Size: 12in. x 12in. - Fully open blades

SAFID certifies that the Class 1A & Class 1 Low Leakage Volume Control Damper shown
herein is licensed to bear the AMCA Seal for Model SPK 30-400. The ratings shown are
based on tests and procedures performed in accordance with AMCA Publication 511 and
comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance Ratings.
Test Information
Tested for air leakage in accordance with ANSI / AMCA Standard 500-D-07,
Figure 5.4. Air leakage is based on operation between 32 ºF and 120 ºF.
Tested for air performance in accordance with ANSI / AMCA Standard 500-D-07
(Pressure Drop), Figure 5.3.
Only 150mm blade width is AMCA certified.
Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

3
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series

Air Performance
Pressure Drop

AMCA Test Figure 5.3

Pressure Drop at Face Area Velocity


Damper Size: 24in. x 24in. - Fully open blades

SAFID certifies that the Class 1A & Class 1 Low Leakage Volume Control Damper shown
herein is licensed to bear the AMCA Seal for Model SPK 30-400. The ratings shown are
based on tests and procedures performed in accordance with AMCA Publication 511 and
comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance Ratings.
Test Information
Tested for air leakage in accordance with ANSI / AMCA Standard 500-D-07,
Figure 5.4. Air leakage is based on operation between 32 ºF and 120 ºF.
Tested for air performance in accordance with ANSI / AMCA Standard 500-D-07
(Pressure Drop), Figure 5.3.
Only 150mm blade width is AMCA certified.
Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

4
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series

Air Performance
Pressure Drop

AMCA Test Figure 5.3

Pressure Drop at Face Area Velocity


Damper Size: 36in. x 36in. - Fully open blades

SAFID certifies that the Class 1A & Class 1 Low Leakage Volume Control Damper shown
herein is licensed to bear the AMCA Seal for Model SPK 30-400. The ratings shown are
based on tests and procedures performed in accordance with AMCA Publication 511 and
comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance Ratings.
Test Information
Tested for air leakage in accordance with ANSI / AMCA Standard 500-D-07,
Figure 5.4. Air leakage is based on operation between 32 ºF and 120 ºF.
Tested for air performance in accordance with ANSI / AMCA Standard 500-D-07
(Pressure Drop), Figure 5.3.
Only 150mm blade width is AMCA certified.
Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

5
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series
Dimensions
1 - Casing 3 - Side Linkage 5 - Tip Seal 7 - Bearing
2 - Actuator 4 - Blade 6 - Side Seal (Jamb Seal) 8 - Landing Angles

Flange Type Flange Type

Flange Type, Opposed Blades Standard Sizes

WIDTH HEIGHT NUMBER OF BLADES FOR


( mm ) ( mm )
100mm 125 mm 150mm
150 100 1 - -
200 150 - - 1
200 200 2 - -
250 250 - 2 -
300 300 - - 2
350 350 1 2 -
400 400 1 - 2
450 450 - - 3
500 500 2 - 2
550 550 - 2 2
600 600 - - 4
650 650 2 - 3
700 700 1 - 4
750 750 - - 5
800 800 2 - 4
850 850 1 - 5
900 900 - - 6

Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

6
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series

Materials - Construction

Axle and Drive Shaft fixing details Mounting Bracket for Actuator

Blade Seal Side Seal or Jamb Seal

Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

7
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series
Installation Details
Damper to Slide on Flange connection Damper to Angle Flange connection

Flange Drilling Details


Flange Drilling Details
Flange drilling details
W H No. of Holes No. of Holes
in mm in mm W Dim. H Dim.
150 150 2 2
200 150 2 2
300 300 3 3
400 300 4 3
500 300 4 3
450 450 4 4
500 450 4 4
600 450 5 4
700 450 6 4
800 450 7 4
900 450 8 4
600 600 5 5
700 600 6 5
800 600 7 5
900 600 8 5
750 750 6 5
800 750 7 5
900 750 8 5
900 900 8 8

Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

8
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series
Order Details

Order Code

SPK 30 - 400 - OB - B - R - 900 X 900 - A

Variants - Code Duct Size Actuator


SPK 30 - 400 S equivalent
SPK 30 - 410 Open-close control

Blade Operation
OB = Opposed Blades operation

External Controls
* R = Right hand (Standard Supply)
Variants - Bearings L = Left Hand
*B = Brass case bearing (Standard Supply)
B1 = Sintered bronze (oilite) case bearing

* - Stands for standard supply.

ORDER EXAMPLE
STANDARD
Make: SAFID
1. Type : SPK 30 - 400 - OB - B - R - 900 x 900 - A
2. Type : SPK 30 - 400 - OB - B1 - R - 900 x 900 - A

Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

9
OpenAir™

Air damper actuators


GSD...1A

Electric motor-driven rotary actuators for open-close, three-position


and modulating control

2 Nm nominal torque
Operating voltage AC 24 V ~ / DC 24…48 V or AC 100…240 V ~
Prewired with 0.9 m connecting cable
Gear train disengagement button for manual adjustment
Position indication
Auxiliary switches for auxiliary functions

30

A6V10636055_en--_e Siemens
2019-03-21 Building Technologies
Features
The rotary actuator drives the damper to the desired operating position after connecting the
operating voltage.
Brushless, robust DC motors ensure reliable operation regardless of load.
The rotary actuators do not require an end position switch, are overload proof, and remain
in place upon reaching the end stop.
The gears are maintenance free and low noise.
Simple and reliable shaft integration.
Mounting bracket included.

Use
Non-spring return rotary actuators. Application in ventilation and air conditioning plants to
operate air dampers and air throttles.
For damper areas up to 0.3 m 2, friction dependent.
Suitable for use with modulating controllers (DC 0/2...10 V), open-close or three-position
controllers.
For directly driven zone dampers to control air flow in air ducts.
We recommend a minimum pulse length of 500 ms on rotary actuators operated with
3-point control to ensure continuous and accurate operation.

Functions

AC 24 V ~ / GSD14..1A GSD16..1A
Type DC 24…48 V
AC 100…240 V ~ GSD34..1A GSD361.1A

Control type Open-close / three-position Modulating control


Rotary direction Clockwise (cw) or counter-clockwise (ccw) direction depends …
… on the type of control. … on the setting of the rotary direction DIL switch
… on the setting of the rotary cw ccw
direction switch.
cw ccw

… on the positioning signal.


The actuator remains in the achieved position:
With no power applied, the actuator
… if the control signal is maintained at a constant
remains in the respective position.
value
… for loss of operating voltage
Position indication: Rotary angle position indication by a position indicator/hand lever.
Mechanical
Position indication: • Output voltage U = DC 0/2...10 V is generated
Electrical proportional to the rotary angle.
• U depends on the rotary direction of the DIL
switch setting.
Auxiliary switches Fixed position 5° / 85°
Manual adjustment The actuator can be manually adjusted by pressing the gear train disengagement
button.

2 / 10
Siemens A6V10636055_en--_e
Building Technologies 2019-03-21
Technical design/mechanical design
Housing
The housing consists essentially of flame retardant, non brominated, non chlorinated glass
fibre reinforced plastic.

Type summary

Type Stock number Control Operating Positioning Position Aux. Rotary Aux.
voltage signal Y indicator U = switches direction power supply
DC 0/2...10 V switch
GSD141.1A S55499-D281 AC 24 V ~ /
Open- DC 24…48 V
GSD146.1A S55499-D227 close 2
or three- yes
GSD341.1A S55499-D282
position AC 100…240 V ~
GSD346.1A S55499-D230 2
GSD161.1A S55499-D228 AC 24 V ~ / yes
GSD166.1A S55499-D229 Modulating DC 24…48 V DC 0/2...10 V yes 2 yes
GSD361.1A S55499-D231 AC 100…240 V ~ yes yes

Product documentation

Topic Title Document ID


Data sheet Air damper actuators GSD..1A A6V10636055_en--
Mounting instructions Rotary-type actuator GSD..1A A6V10636060_----

Related documents such as environmental declarations, CE declarations, etc., can be


downloaded at the following Internet address:
http://siemens.com/bt/download

Notes

Safety

Caution

National safety regulations


Failure to comply with national safety regulations may result in personal injury and property
damage.
Observe national provisions and comply with the appropriate safety regulations.
Use only properly trained technicians for mounting, commissioning, and servicing.

Engineering
Auxiliary switches
Auxiliary switches cannot be added in the field.

3 / 10
A6V10636055_en--_e Siemens
2019-03-21 Building Technologies
Technical data

Power supply GSD14..1A / GSD16..1A


Operating voltage (SELV/PELV) / Frequency AC 24 V ~ ±20 % (19.2…28.8 V ~) / 50/60 Hz
1)
DC 24…48 V ±20 % (19.2…57.6 V )
Power consumption running GSD14..1A 2.2 VA / 1.2 W
GSD16..1A 2.4 VA / 1.4 W
Power consumption holding GSD14..1A 1 VA / 0.5 W
GSD16..1A 1.2 VA / 0.7 W

Power supply GSD34..1A / GSD361.1A


Operating voltage / Frequency AC 100…240 V ~ ±10 % (90…264 V ~) / 50/60 Hz
Power consumption running GSD34..1A 4.5 VA / 1.8 W
GSD361.1A 3.7 VA / 1.4 W

Power consumption holding GSD34..1A 2.4 VA / 0.9 W


GSD361.1A 1.6 VA / 0.5 W

Functional data
Nominal torque 2 Nm
Maximum torque 5 Nm
Nominal rotational angle 90°
Maximum rotational angle (mechanically limited) 95° ± 2°
Runtime at nominal rotational angle 90° 30 s
Duty cycle 100 %
Direction of rotation Clockwise / counterclockwise
Mechanical life 100 000 cycles
Actuator sound power level 35 dB(A)

Inputs
Positioning signal for GSD14..1A
Operating voltage (wires 1-6/G-Y1) clockwise
AC 24 V ~ / DC 24…48 V (wires 1-7/G-Y2) counterclockwise
Positioning signal for GSD34..1A
Operating voltage (wires 4-6/N-Y1) clockwise
AC 100…240 V ~ (wires 4-7/N-Y2) counterclockwise
Positioning signal for GSD16..1.A
Input voltage (wires 8-2/Y-G0) DC 0/2…10 V
Current consumption 0.1 mA
Input resistance >100 k

Outputs
Position indicator
Output signal (GSD16..1.A) (wires 9-2/U-G0)
Output signal (GSD361.1.A) (wires 9-2/U-G-)
Output voltage U DC 0...10 V
Max. output current DC ±1 mA
Protected against faulty wiring max. AC 24 V ~ / DC 24…48 V
Aux. power supply (GSD361.1A) (wires 1-2/G+-G-) DC 24 V ±20 %, max. 10 mA

Auxiliary switches
Switching voltage AC 24…250 V ~ / DC 12…30 V
Contact rating 6 A resistive, 2 A inductive, min. 10 mA @ AC
4 A resistive, 2 A inductive, min. 10 mA @ DC 30 V
0.8 A res., 0.5 A inductive, min. 10 mA @ DC 60 V
Electric strength auxiliary switches against housing AC 4 kV
Factory switches setting: Switch A / Switch B 5° / 85° (fixed position)

5 / 10
A6V10636055_en--_e Siemens
2019-03-21 Building Technologies
Connection cables
Cable length 0.9 m
2
Cross-section 0.75 mm

Degree of protection
Insulation protective class As per EN 60730
AC 24 V ~ / DC 24…48 V III
AC 100…240 V ~ II
Housing protection IP54 as per EN 60529

Environmental conditions
Operation IEC 60721-3-3
Climatic conditions Class 3K5
Mounting location Interior, weather-protected
Temperature (extended) -32...+55 °C
Humidity, non-condensing <95 % r.F.
Transportation IEC 60721-3-2
Climatic conditions Class 2K3
Temperature (extended) -32...+70 °C
Humidity, non-condensing <95 % r.F.
Storage IEC 60721-3-1
Climatic conditions Class 1K3
Temperature (extended) -32...+50 °C
Humidity, non-condensing <95 % r.F.
Mechanical conditions Class 2M2

Standards, directives and approvals


Product standard EN 60730
Part 2-14 / Particular requirements for electric actuators
Electromagnetic compatibility For use in residential, commerce, light-industrial and
(Applications) industrial environments
2)
EU Conformity (CE) A5W00004362
2)
RCM Conformity A5W00004363
EAC Conformity Eurasian conformity
UL UL as per UL 60730 http://ul.com/database
1)
cUL as per CSA-C22.2 No. 24-93

Environmental compatibility
2)
The product environmental declaration A5W00030346-A contains data on environmentally compatible product
design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal).

Dimensions
Actuator W x H x D See "Dimensions” p. 9
Damper shaft
round 8…15 mm
Square 6…11 mm
Min. shaft length 20 mm
Shaft hardness <300 HV

Weight
Excl. packaging Max. 0.55 kg, without switches
Max. 0.7 kg, with switches

1)
Permitted only to DC 30 V
2)
The documents can be downloaded from http://siemens.com/bt/download.

6 / 10
Siemens A6V10636055_en--_e
Building Technologies 2019-03-21
Diagrams

Internal Diagrams

GSD14..1A (Open-close, three-p.) GSD34..1A (Open-close, three-p.)

AC 24 V ~ / DC 24…48 V AC 100…240 V ~

III
AC 24 V ~ AC 24...250 V ~ / 6 (2) A AC 24...250 V ~ / 6 (2) A
DC 24...48 V DC 12...30 V / 2 A AC 100...240 V ~ DC 12...30 V / 2 A
1 S1 S4 6 7 S1 S4

M 1) 1)
M

6 7 S2 S3 S5 S6 4 S2 S3 S5 S6
N

GSD16..1A (Modulating control) GSD361.1A (Modulating control)

AC 24 V ~ / DC 24…48 V AC 100…240 V ~

III AC 24 V ~ AC 24...250 V ~ / 6 (2) A SELV/PELV


DC 24...48 V DC 0/2...10 V DC 12...30 V / 2 A DC 24 V DC 0/2...10 V
AC 100...240 V ~
1 8 3 1 8

100%
1) 100%
M M
0% 0%

G0 U N G-
2 9 4 2 9
N
DC 0/2...10 V DC 0/2...10 V

1)
Actuator Switch A Switch B
Position Common S1 Common S4
connected to connected to
0°…5° S3 S6
5°…85° S2 S6
85°…90° S2 S5

7 / 10
A6V10636055_en--_e Siemens
2019-03-21 Building Technologies
Connection diagrams

GSD1..1A (AC 24 V ~ / DC 24…48 V )

Open-close, single wire control Open-close, two wire control Three-position control Modulating control
Single Pole Single Throw (SPST) Single Pole Double Throw (SPDT)
AC 24 V ~ AC 24 V ~ AC 24 V ~ AC 24 V ~
DC 24...48 V DC 24...48 V DC 24...48 V DC 24...48 V

G G G

Y1 Y2 Y1 Y2 Y1 Y2 G Y U

G0

AC 24 V ~ AC 24 V ~ AC 24 V ~
DC 24...48 V DC 24...48 V DC 24...48 V

Y1 Y2 Y1 Y2 Y1 Y2

G G G

GSD3..1A (AC 100…240 V ~)

Open-close, single wire control Open-close, two wire control Three-position control Modulating control
Single Pole Single Throw (SPST) Single Pole Double Throw (SPDT)

AC 100...240 V ~ AC 100...240 V ~ AC 100...240 V ~ AC 100...240 V ~

Y1 Y2 Y1 Y2 Y1 Y2 L G+ Y U

N N N N G-

N N N N

Cable labeling

Connection Code No Color Abbreviation Meaning


Actuators G 1 red RD System potential AC 24 V ~ / DC 24…48 V
AC 24 V ~ G0 2 black BK System neutral
DC 24…48 V Y1 6 purple VT Positioning signal AC/DC 0 V, “clockwise” (GSD14..1A)
Y2 7 orange OG Positioning signal AC/DC 0 V, “counterclockwise” (GSD14..1A)
Y 8 grey GY Signal in (GSD16..1A)
U 9 pink PK Signal out (GSD16..1A)
Actuators L 3 brown BR Line AC 100…240 V ~
AC 100…240 V ~ N 4 light blue BU Neutral conductor
Y1 6 black BK Positioning signal AC 100…240 V ~, “clockwise” (GSD34..1A)
Y2 7 white WH Positioning signal AC 100…240 V ~, “counterclockwise” (GSD34..1A)
G+ 1 red RD System potential DC 24 V (GSD361.1A)
G- 2 black BK System neutral (GSD361.1A)
Y 8 grey GY Signal in (GSD361.1A)
U 9 pink PK Signal out (GSD361.1A)
Auxiliary switch Q11 S1 grey/red GY RD Switch A input
Q12 S2 grey/blue GY BU Switch A normally open contact
Q14 S3 grey/pink GY PK Switch A normally closed contact
Q21 S4 black/red BK RD Switch B input
Q22 S5 black/blue BK BU Switch B normally open contact
Q24 S6 black/pink BK PK Switch B normally closed contact

8 / 10
Siemens A6V10636055_en--_e
Building Technologies 2019-03-21
Dimensions

Dimensions in mm

9 / 10
A6V10636055_en--_e Siemens
2019-03-21 Building Technologies
Air damper actuators
GEB..1E

Electronic rotary
y actuators for 2-position, 3-position, and modulating control

Nominal torque 20 Nm

Mechanica
Pre-wired with standard 0.9 m connection cables
Type-specific
Type specific variations with adjustable offset and span for
the positioning signal
Position indication: Mechanical and electrical
Feedback potentiometer
Self-adaption
adap of the rotation angle range and adjustable auxiliary switches
for supplemental functions

A6V11449860_en--a Smart Infrastructure


2019-09-10
Use
Rotary actuators are used in ventilation and air conditioning plants to regulate and shut off
air dampers:
For damper areas up to approximately 4 m 2 (Guideline: Always comply with the damper
manufacturer's specifications).
Suitable for use with 2-position and 3-position controllers as well as modulating

We recommend a minimum pulse length of 500 ms on rotary actuators operated with 3-


point control to ensure continuous and accurate operation.

Functions

AC 24 V ~ / 141.1E / 142.1E / 146.1E 161.1E / 163.1E / 164.1E / 166.1E


GEB..
341.1E / 346.1E 361.1E
Control type 2-position / 3-position
Rotary movement,
rotary direction
clockwise / counterclockwise
switch. cw ccw
cw ccw selfadapt selfadapt
2... 2...

0 0... 0 0...
The actuator remains in the respective
position with no power applied.
The actuator remains in the deployed
position:

cw = Clockwise constant value


ccw = Counterclockwise wer loss
Position indication
Rotation angle position indication using a position indicator.
Mechanical
Position indication By connecting the feedback potentio- Position indicator: Output voltage
Electric meter to external voltage, output voltage U = DC
is generated proportional to rotation to rotation angle.
angle. The direction of rotation (inverted or non-
inverted) for output voltage U is based on
the DIL switch position.
Auxiliary switch The switching points for auxiliary switches A and B can be set independently in

Self-adaptation
adaptation of the The actuator automatically determines the
rotation angle range mechanical end positions of the rotation
angle range.
The characteristic function (Uo, U) is
-
mapped to the calculated rotation angle
range.
Power must be connected to DIL switch 2
(self-adaptation) for the function to operate.
Manual adjustment The actuator can be manually adjusted by pressing the gear train disengagement
button.
Rotation angle limitation

2
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Technical design

Housing
Robust and light cast aluminum housing. The housing guarantees long life, even under
harsh ambient conditions.

Actuator / gears
Brushless, robust DC motors ensure reliable operation regardless of load. The damper
actuators do not require an end position switch, are overload proof, and remain in place
upon reaching the end stop.
The gears are maintenance free and low noise.

Type summary
Type Stock number Open-loop Operating Positioning Position Feedback Self-adapting Auxili- Rotation
control voltage signal input Y indicator potentio- rotation angle ary direction
U = DC meter ranges switch switch
5k

GEB141.1E S55499-D329 -
AC 24 V ~ / -
GEB142.1E S55499-D330 Yes
2- or 3-
GEB146.1E S55499-D331 - - - 2 Yes
position
GEB341.1E S55499-D336 - -

GEB346.1E S55499-D337 2

GEB161.1E S55499-D332 DC 0/
-
GEB163.1E S55499-D333 AC 24 V ~ /
GEB164.1E S55499-D334 Modulating Yes - Yes Yes
2
GEB166.1E S55499-D335

GEB361.1E S55499-D338 -

Accessories/spare parts
See data sheet N4697

Product documentation

Topic Title Document ID


Data sheet Air damper actuators A6V11449860

Technical principles Non- Z4621

Mounting Instructions GEB..1E A6V11476940

Data sheet Accessory and spare parts for air damper actuators N4697

Related documents such as environmental declarations, CE declarations, etc., can be


downloaded at the following Internet address:
http://siemens.com/bt/download

3
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Notes

Safety

CAUTION

National safety regulations


Failure to comply with national safety regulations may result in personal injury and property
damage.
Observe national provisions and comply with the appropriate safety regulations.
Mounting, commissioning, and service by properly trained personnel only.

Engineering

Auxiliary switch and potentiometer


Cannot be integrated after the fact.

Mounting

See Mounting instructions M4621

Shaft connection
When mounting, comply with the notes on shaft diameters and damper surface areas in
Technical data (page 8) and use only quality materials typical to the sector for the damper
shaft.

Installation

WARNING

No internal line protection for supply lines to external consumers


Risk of fire and injury due to short-circuits!
Adapt the line diameters as per local regulations to the rated value of the installed fuse.

Maintenance
The GEB..1E actuators are maintenance-free.

4
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Disposal

The device is considered an electronic device for disposal in accordance


with the European Guidelines and may not be disposed of as domestic
garbage.
Dispose of the device through channels provided for this purpose.
Comply with all local and currently applicable laws and regulations.

5
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Technical data

Power supply (GEB1..1E)


Operating voltage (SELV/PELV)
) 1)
Frequency 50/60 Hz
Power consumption: During GEB14..1E 2.3 VA / 1,1 W
operation GEB16..1E 2.5 VA / 1.2 W
Holding GEB14..1E 0.5 W
GEB16..1E 0.65 W

Power supply (GEB3..1E)


Operating voltage (SELV/PELV)
Frequency 50/60 Hz
Power consumption: During GEB34..1E 4 VA / 1.6 W
operation GEB36..1E 3.4 VA / 1.3 W
Holding GEB34..1E 0.9 W
GEB36..1E 0.6 W

Function data
Nominal torque 20 Nm
Maximum torque (when blocked) 35 Nm 2)
Minimum holding torque 20 Nm
Nominal rotation angle (with position indication)
Maximum rotation angle (mechanically limited)
Runt 150 s
Actuator sound power level (at a positioning time of 150 s) <35 dB(A)

Inputs
Positioning signal for GEB14..1E
Operating voltage (wires 1-6/G-Y1) Clockwise
(wires 1-7/G-Y2) Counterclockwise
Positioning signal for GEB34..1E
Operating voltage (wires 1-6/G-Y1) Clockwise
(wires 1-7/G-Y2) Counterclockwise
Positioning signal for GEB16..1E
Input voltage (wires 8-2/Y-G0) DC 0/
Power consumption 0.1 mA
Input resistance >100 k
Max. permissible input voltage DC 35 V limited internally to DC 10 V
Protected against faulty wiring
Hysteresis for non-adjustable characteristic function 60 mV
for adjustable characteristic function 0.6
Adjustable characteristic (GEB163.1E, GEB164.1E)
Adjustable with 2 potentiometers: Offset Uo

Max. input voltage DC 35 V


Protected against faulty wiring

1) cUL: Only to DC 30 V permissible


2) See notes on page 4 and page 8

6
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Outputs
Position indicator
Output signal (GEB16..1E) (wires 9-2/U-G0)
Output signal (GEB36..1E) (wires 9-2/U-G-)
Output voltage U
Max. output current
Protected against faulty wiring
Aux. power supply (G-/G+)
GEB36.. DC 24 V
Feedback potentiometer (for GEB142.1E)
Change in resistance (wires P1-P2)
Load <0.25 W
Max. contact current <0.1 mA
Permissible voltage at potentiometer (SELV/PELV)
Insulation resistance between potentiometer and AC 500 V ~
housing

Auxiliary switches (GEB146.1E, GEB166.1E, GEB346.1E)


Switching voltage
Contact loading 6 A resistive, 2 A inductive, min. 10 mA @ AC
4 A resistive, 2 A inductive, min. 10 mA @ DC 30 V
0.8 A resistive, 0.5 A inductive, min. 10 mA @ DC 60 V
Electric strength auxiliary switch against housing AC 4 kV
Switching range for auxiliary switches / setting
increments
Factory switch setting: Switch A
Switch B

Connection cables
Cable length 0.9 m
Cross-section 0.75 mm2
Permissible length for signal wires 300 m

Safety class and degree of protection


Protection class EN 60730
, feedback III
potentiometer II

Degree of protection of housing IP54 as per EN 60529 (see "Mounting", page 4, and
Mounting instructions A6V11476940)

Environmental conditions
Operation IEC 60721-3-3
Climatic conditions Class 3K5
Mounting location interior, weather-protected
Temperature -
Humidity, non-condensing <95 % r.h.
Transportation IEC 60721-3-2
Climatic conditions Class 2K3
Temperature -
Humidity, non-condensing <95 % r.h.
Storage IEC 60721-3-1
Climatic conditions Class 1K3
Temperature -
Humidity, non-condensing <95 % r.h.
Mechanical conditions Class 2M2

7
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Standards, directives and approvals
Product standards EN60730
Part 2-14: Particular requirements for electric
actuators
Electromagnetic compatibility (field of use) For residential, commercial, and industrial
environments
EU conformity (CE) A5W00051707 3)
RCM conformity A5W00051708 3)
EAC compliance Eurasian conformity
UL UL as per 60730 http://ul.com/databse
Federal Communications Commission cUL as per CSA-C22.2 No. 24-93

Environmental compatibility
The product environmental declaration A5W00055607 3) contains data on environmentally compatible product
design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal).

Dimensions
Actuator (W x H x D) See "Dimensions" (page 11)
Damper shaft
Round
Square (diagonal) .5 mm
Min. length 20 mm
Max. shaft hardness <300 HV

Weight
Excl. packaging Max. 1.1 kg, without auxiliary switches
Max. 1.3 kg, with auxiliary switches

3) Documents can be downloaded at http://siemens.com/bt/download.

Shaft connection Important notes for the manufacturer / installer


Use of unsuitable damper shafts may damage the damper or damper shaft.
Use only damper shafts with diameters suitable for the damper surface.
Use only quality materials typical for the sector for damper shafts/rods.

8
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Connection diagrams

Internal Diagrams

GEB14..1E GEB34..1E
(open-close, 3-position control) (open-close, 3-position control)

III AC 24...250 V ~ / 6 (2) A


SELV/PELV DC 12...30 V / 2 A AC 24...250 V ~ / 6 (2) A
AC 24 V ~
DC 24...48 V 0...5000 AC 100...240 V ~ DC 12...30 V / 2 A

1 6 7 S1 S4

100%
M 5° 85°
M 5° 85°
0%

6 7 4 S2 S3 S5 S6
N

GEB16..1E GEB16..1E GEB361.1E


(modulating, Y = DC 0 ) ) )

SELV/PELV
III AC 24 V ~ AC 24...250 V ~ / 6 (2) A III AC 24 V ~ AC 24...250 V ~ / 6 (2) A DC 24 V DC 0/2...10 V
DC 24...48 V DC 0/2...10 V DC 12...30 V / 2 A DC 24...48 V DC 0...35 V DC 12...30 V / 2 A AC 100...240 V ~
3 1 8
1 8 1 8

100%
100% 100%
M
M M
0%
0% 0%
N G-
G0 U G0 U
4 2 9
2 9 2 9 N
DC 0/2...10 V
DC 0/2...10 V DC 0/2...10 V

Connection diagrams
)

Open-close, single wire control Open-close, double wire control 3-position control Modulating control
Single pole single throw (SPST) Single pole double throw (SPDT)
AC 24 V ~ AC 24 V ~ AC 24 V ~ AC 24 V ~
DC 24...48 V DC 24...48 V DC 24...48 V DC 24...48 V

G G G

Y1 Y2 Y1 Y2 Y1 Y2 G Y U

G0

AC 24 V ~ AC 24 V ~ AC 24 V ~
DC 24...48 V DC 24...48 V DC 24...48 V

Y1 Y2 Y1 Y2 Y1 Y2

G G G

9
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Open-close, single wire control Open-close, double wire control 3-position control Modulating control
Single pole single throw (SPST) Single pole double throw (SPDT)
AC 100...240 V ~ AC 100...240 V ~ AC 100...240 V ~
AC 100...240 V ~

Y1 Y2 Y1 Y2 Y1 Y2 L G+ Y U

N N N N G-

N N N N

Cable designations

Connecting thread Code No. Color Abbreviation Meaning


Actuators G 1 red RD
G0 2 black BK System zero
Y1 6 violet VT Positioning signal AC/DC 0 V, clockwise (GEB14..1E)
Y2 7 orange OG Positioning signal AC/DC 0 V, counterclockwise (GEB14..1E)
Y 8 gray GY Signal input (GEB16..1E)
U 9 pink PC Signal output (GEB16..1E)
Actuators L 3 brown BR
N 4 light blue BU Neutral conductor
Y1 6 black BK B34..1E)
Y2 7 white WH
G+ 1 red RD System potential DC 24 V (auxiliary power) (GEB361.1E)
G- 2 black BK System neutral (auxiliary power) (GEB361.1E)
Y 8 gray GY Signal input (GEB361.1E)
U 9 pink PK Signal output (GEB361.1E)
Feedback potentiometer a P1 white/red WH RD -P2)
b P2 white/blue WH BU Potentiometer pick-off
c P3 white/pink WH PK -P2)
Auxiliary switch Q11 S1 gray/red GY RD Switch A input
Q12 S2 gray/blue GY BU Switch A NC contact
Q14 S3 gray/pink GY PK Switch A NO contact
Q21 S4 black/red BK RD Switch B input
Q22 S5 black/blue BK BU Switch B Normally closed contact
Q24 S6 black/pink BK PK Switch B NO contact

10
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Dimensions

min. 60

min. 100

Dimensions in mm

11
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Appendix to the License Agreement To Use
The AMCA Certified Ratings Program Seal
Appendix No: 8
In accordance with the License Agreement issued on November 21, 2012 by Air Movement and Control
Association International, Inc., SAFID, is hereby authorized to use the AMCA Certified Ratings Seal on the specific
air movement and control devices listed below. Such use shall in all respects be governed by and subject to the
provisions of said License Agreement.

Dampers
Product Line Catalog ID
SPK30-400 Class 1A & Class 1 Low Leakage SPK30-400 January, 2014
Volume Control Damper

Minimum Minimum Model


Width Height Name
3.94 x 3.94 SPK30-400

Maximum Maximum Model


Width Height Name
35.43 x 35.43 SPK30-400

*License to Bear the AMCA Seal for Air Leakage, Air Performance

Please verify current certification status in the AMCA International Directory of Licensed Products located at
www.amca.org.
Granted This 18th day of March, 2014.

Lisa R. Ullrich
Certified Ratings Program Manager
AIR MOVEMENT AND CONTROL ASSOCIATION
INTERNATIONAL, INC.

Page 1 of 1
The Free Zones Authority of
the State of Qatar

(OCS) Observation and Comment Sheet


Project : Design and Construction of Light Industrial Unit for CITYNEON Document Ref. No : R49-AMA-MAR-AC-0101
Consultant : Al Khaleej engineering and industrial consultancy Rev. No : 00
Contractor : Amana Qatar Contracting
Title & Rev : Motorized Volume Control Damper - SAFID

Reviewed Document / Drawing No.: R49-AMA-MAR-AC-0101 Submittal No. : R49-AMA-MAR-AC-0101 Issued Date : 03 Jan 2023.

QFZA Stamp: Actionee Initials


Assessment Code: A = Approved Prepared by KA
B = Approved with Comments
Reviewed by AG
C
C = Revise & Resubmit
SA
D = Not Approved / Rejected Cleared by
ZH
QFZA / Consultant Contractor - AMANA QFZA
Identification of Sign-Off
S/N Reviewer comment's source: Observations / Comments Document Ref. No. Comments (if any) Code [Open
[doc/part/page/para] Closed]

SAFID is not specified in the PVL. Contractor to submit the proposal


1 KEIC-KA PVL along with a written justification for deviation from the Preferred Vendor R49-AMA-MAR-AC-0101 C OPEN
List for the Engineer’s review.
Provide a readable and clear compliance statement

2 KEIC-KA Specification R49-AMA-MAR-AC-0101 fully compatible with future BMS interface and connection. C OPEN

Provide reference drawings for the project with highlight on the areas
3 KEIC-KA Area of application R49-AMA-MAR-AC-0101 B Open
where the material shall be used.

4 KEIC-KA Size Size of the damper is subject to the approved drawings R49-AMA-MAR-AC-0101 B OPEN

All the delivered dampers shall be labelled. Without labelling the


5 KEIC-KA Labelling R49-AMA-MAR-AC-0101 B Open
material will be rejected
To include the impact of air pressure in the calculation of fans static
6 KEIC-KA ESP R49-AMA-MAR-AC-0101 B Open
pressure
The Motorized Volume Control Damper shall be fully compatible
7 KEIC-KA BMS R49-AMA-MAR-AC-0101 C OPEN
with future BMS interface and connection.
All installation shall comply with project and authorities
8 KEIC-KA Installation R49-AMA-MAR-AC-0101 B OPEN
requirements and manufacturer recommendations

9 KEIC-KA GSAS Provide compliance with GSAS where applicable R49-AMA-MAR-AC-0101 B OPEN

Page 1 of 2 Base on Template: QFZA-034_V_1_0


The Free Zones Authority of
the State of Qatar

Reviewed Document / Drawing No.: R49-AMA-MAR-AC-0101 Submittal No. : R49-AMA-MAR-AC-0101 Issued Date : 03 Jan 2023.

QFZA Stamp: Actionee Initials


Assessment Code: A = Approved Prepared by KA
B = Approved with Comments
Reviewed by AG
C
C = Revise & Resubmit
SA
D = Not Approved / Rejected Cleared by
ZH
QFZA / Consultant Contractor - AMANA QFZA
Identification of Sign-Off
S/N Reviewer comment's source: Observations / Comments Document Ref. No. Comments (if any) Code [Open
[doc/part/page/para] Closed]
Detailed method statement to be submit separately. Installation shall be
10 KEIC-KA Method Statement R49-AMA-MAR-AC-0101 B OPEN
as per project, QCS2014 and supplier recommendations.
As per SOW, Submit Catalogue, sample and Complete Installation
11 KEIC-KA Sample R49-AMA-MAR-AC-0101 C OPEN
including fixing of Dampers and VCD (PDS, FSS)
Warranty shall be as project specification and authority
12 KEIC-KA Warranty R49-AMA-MAR-AC-0101 B OPEN
requirements.
Contractor shall use only one brand in the project. Mixing is not
13 KEIC-KA Mixing R49-AMA-MAR-AC-0101 NOTE
permitted.
Material availability and the delivery period to be considered as per
14 KEIC-KA Delivery R49-AMA-MAR-AC-0101 NOTE
project timeline
During material delivery following documents to be attached:
1.Delivery note 2.Country of origin 3.Packing list 4.Bill of lading
15 KEIC-KA R49-AMA-MAR-AC-0101 NOTE
5.Test certificates 6.Warranty certificate and other applicable
documents as per project requirement
All the relevant certificates should be valid at the time of usage on
16 KEIC-KA R49-AMA-MAR-AC-0101 NOTE
site and throughout the work.
The approval shall not relieve the contractor from his obligations to
perform the design/installation/testing commissioning in
17 KEIC-KA R49-AMA-MAR-AC-0101 NOTE
accordance with the contract documents, relevant specifications
and local authority regulations.
The Client reserves his right to withdraw the approval in case of
18 KEIC-KA R49-AMA-MAR-AC-0101 NOTE
improper performance/deficient quality of works.
Actionee Name Role Ι Designation Signature

Prepared &
Kamal Azayem Sr. Mechanical Engineer
Reviewed by :
Checked by: Anees Gafoor Construction Manager

Checked by: Sharmarke Ali Design Manager

Cleared by : Zuhair Hasanain Project Manager

Page 2 of 2 Base on Template: QFZA-034_V_1_0


MATERIAL SU BMITTAL CHECK LIST

Sl DESCRIPTION Attached Remarks


no
yes No N/A
1 Supplier & manufacture profile
2 Industrial/trade license
3 Company legal documents (CR, ISO
certificates)
4 Scope of work
5 Technical compliance statement
6 Technical data sheet
7 Test reports
8 Material safety data sheet
9 Previous approval
10 List of previous projects
11 Country of origin
12 Draft warranty
13 Material/Product sample photo
1. Supplier & Manufacturer Profile
Supplier’s Profile
Manufacturer’s Profile
LETTER OF CONFIRMATION
To Whom It May Concern,

We SAFID LTD, Doha, QATAR, herewith certify and confirm that M/s. Gulf Facilities Trading & Contracting
W.L.L. located in Qatar is our local dealer and trader of SAFID LTD CO. MAKE PRODUCTS in State of Qatar.

We hope that the above is in line with your requirement.

Customer Service Manager


02/JAN/2022, DOHA, QATAR
Best in Class – Full Line of Products & Services
Best in Class – Full Line of Products & Services

For over 35 years, SAFID has been an industry leader providing


best in class air quality solutions
Products & Accessories

 Dampers
 Silencers
 Acoustic Enclosures
 Plenum Boxes
 Louvers
 Kitchen Hoods
 Access Doors
 Supports & Bands
 Flexible Connectors
 Flanges & Accessories
 Tapes & Sealants
Develop & manufacture certified products

- Our products are constantly tested by UL, AMCA,


AHRI & SRL

- Our products are manufactured based on


ASHRAE, SMACNA & other international
standards

- All our sheet metal are in accordance with ASTM


standards

- Perform certification testings' for tailor made


products to your projects
Vision, Mission, Strategy & Positioning
SAFID Vision
Our vision is to play a major role in the development of public and
private projects across the region, having a major impact on the
health and wellness of everyone living and working within the built
environment.

SAFID Mission
Our mission is to offer our customers and end users a completely
bespoke product line that is reliable in performance and delivery and
is of the highest standard.

SAFID Strategy
Our strategy is to offer the most innovative and complete indoor air
solutions in order to maintain our position as the region’s leading
HVAC manufacturer.

SAFID Positioning
SAFID is well positioned to add real value to projects of all sizes by
offering a reliable custom-made product that meets international
standards of safety and design as well as engineering guidance on
product development.

11
Our Team

Taking its long-term employment policy to heart, SAFID continues


to invest in its most valuable element and factor of success, the
“Human Resource.” Hence, regular training programs are provided to
supervisors and production engineers to ensure the smooth execution
of manufacturing.

The SAFID team is supported by over 40 production and sales engineers,


along with many supervisors and foremen, and backed by qualified
R&D, Quality Control and Marketing Departments. Moreover, the IT
Department has developed numerous in-house software programs that
have succeeded in linking various departments and guaranteed the
weaving of a professional control tool through the production process,
thus providing a better service to clients.

Safid currently employs in the GCC area a total work force of over 900
highly qualified staff distributed on the departments as follows:

• Sales, Production & Engineering Department: 40 Engineers


• Factory & Production Supervisors: 22
• R&D Department: 3
• Administrative Staff and Employees: 17
• Production Labor: 800

13
Products & Services
Air Distribution Systems Catalogue
• Spiral Ductwork & Accessories
• Double Wall Ductwork & Accessories
• Oval Ductwork & Accessories
• Oval Double Wall Ductwork & Accessories
• Rectangular Ductwork & Accessories
• Flexible Ductwork & Accessories
• LINDAB Safe Spiral Ductwork & Accessories
• LINDAB Tranfer
• LINDAB Comfort

Air Devices & Terminals Catalogue


• Square Ceiling Diffusers
• Round Ceiling Diffusers
• Slot Diffusers
• Grilles & Registers
• Bar Grilles
• Duct Grilles
• Nozzles
• Displacement Ventilation
• VAVs
• Duct Heaters

Products & Accessories Catalogue


• Dampers
• Silencers
• Acoustic Enclosures
• Plenum Boxes
• Louvers
• Lab & Industrial Kitchen Hoods
• Supports & Bands
• Access Doors
• Flexible Connectors
• Sealants, Tapes, Flanges & Accessories

SAFID’s products are manufactured using galvanized black steel,


stainless steel and aluminium. Its complete range of products are
manufactured to either respond to clients’ standards and construction
methods or to clients’ tailor-made and individual specifications of air
distribution systems.

Aside from the standard systems, SAFID also manufactures special


products that are used for industrial and special applications to handle
fumes, vapors, and chemicals.

15
Standards & Certifications

21
2. Industrial/Trade License
‫>‪<Bar Code‬‬
‫‪2022/12/04‬‬ ‫ﺗﺎﺭﻳﺦ ﺍﻟﻄﺒﺎﻋﺔ‪:‬‬
‫‪No 1 of 1‬‬ ‫ﺻﻔﺤﺔ ﺭﻗﻢ‪:‬‬

‫ﺭﺧﺼﺔ ﺗﺠﺎﺭﻳﺔ‬

‫*‪*42969‬‬
‫‪2014/12/09‬‬ ‫ﺗﺎﺭﻳﺦ ﺍﺻﺪﺍﺭ ﺍﻟﺮﺧﺼﺔ‪:‬‬ ‫‪42969‬‬ ‫ﺭﻗﻢ ﺍﻟﺮﺧﺼﺔ‪:‬‬
‫‪2023/12/09‬‬ ‫ﺗﺎﺭﻳﺦ ﺍﻧﺘﻬﺎﺀ ﺍﻟﺮﺧﺼﺔ‪:‬‬ ‫ﺷﺮﻛﺔ ﺍﻟﺘﺴﻬﻴﻼﺕ ﺍﻟﺨﻠﻴﺠﻴﺔ ﻟﻠﺘﺠﺎﺭﺓ‬ ‫ﺍﻷﺳﻢ ﺍﻟﺘﺠﺎﺭﻯ‪:‬‬
‫ﻭﺍﻟﻤﻘﺎﻭﻻﺕ‬
‫‪25454‬‬ ‫ﺭﻗﻢ ﺍﻟﺴﺠﻞ ﺍﻟﺘﺠﺎﺭﻯ‪:‬‬ ‫ﺷﺮﻛﺔ‬ ‫ﻧﻮﻉ ﺍﻟﻤﻨﺸﺄﺓ ﺍﻟﺘﺠﺎﺭﻳﺔ‪:‬‬
‫ﺍﻟﺴﻤﺔ ﺍﻟﺘﺠﺎﺭﻳﺔ‪:‬‬

‫ﺑﻴﺎﻧﺎﺕ ﺍﻟﻤﺪﻳﺮ ﺍﻟﻤﺴﺆﻭﻝ ‪:‬‬


‫ﻣﻴﻼﺩ ﻋﻔﻴﻒ ﻓﺮﺍﻥ‬ ‫ﺍﺳﻢ ﺍﻟﻤﺪﻳﺮ ﺍﻟﻤﺴﺌﻮﻝ‪:‬‬
‫ﻟﺒﻨﺎﻥ‬ ‫ﺟﻨﺴﻴﺔ ﺍﻟﻤﺪﻳﺮ ﺍﻟﻤﺴﺌﻮﻝ‪:‬‬ ‫‪27842200123‬‬ ‫ﺭﻗﻢ ﺍﻹﺛﺒﺎﺕ‪:‬‬
‫ﻧﻤﻮﺫﺝ ﺧﺘﻢ ﺍﻟﻤﻨﺸﺄﺓ ﺍﻟﺘﺠﺎﺭﻳﺔ ‪:‬‬ ‫ﺑﻴﺎﻧﺎﺕ ﺍﻟﻤﻮﻗﻊ ‪:‬‬
‫‪84‬‬ ‫ﻋﻘﺎﺭ ﺭﻗﻢ‪:‬‬ ‫ﺗﺠﺎﺭﻱ‬ ‫ﺗﺼﻨﻴﻒ ﺍﻟﻤﻮﻗﻊ‪:‬‬
‫ﺭﻗﻢ ﺍﻟﺪﻭﺭ‪ /‬ﺍﻟﻮﺣﺪﺓ‪:‬‬ ‫ﻣﻜﺘﺐ ﺗﺠﺎﺭﻱ‬ ‫ﻧﻮﻉ ﺍﻟﻤﻮﻗﻊ‪:‬‬
‫ﻧﺎﺻﺮ ﺑﻦ ﺟﺒﺮ ﺑﻦ ﺍﺣﻤﺪ‬
‫ﺍﻻﺣﻤﺪ ﺍﻝ ﺛﺎﻧﻲ‬
‫ﺍﺳﻢ ﻣﺎﻟﻚ ﺍﻟﻌﻘﺎﺭ ‪:‬‬ ‫‪ 56‬ﻋﻴﻦ ﺧﺎﻟﺪ‬ ‫ﺍﻟﻤﻨﻄﻘﺔ‪:‬‬
‫ﻧﻮﻉ ﺍﻟﺮﺧﺼﺔ ‪:‬‬ ‫ﻃﺮﻳﻖ ﺳﻠﻮﻯ‬ ‫ﺍﻟﺸﺎﺭﻉ‪:‬‬
‫ﺑﻠﺪﻳﻪ ﺍﻟﺮﻳﺎﻥ ‪ /‬ﻋﻴﻦ ﺧﺎﻟﺪ ‪/‬‬
‫ﺷﺎﺭﻉ ﻃﺮﻳﻖ ﺳﻠﻮﻯ‬
‫ﻭﺻﻒ ﺍﻟﻌﻨﻮﺍﻥ ‪:‬‬ ‫‪205‬‬ ‫ﺭﻗﻢ ﺍﻟﺸﺎﺭﻉ ‪:‬‬
‫ﺍﻷﻧﺸﻄﺔ ﺍﻟﺘﺠﺎﺭﻳﺔ ‪:‬‬

‫ﺇﺳﻢ ﺍﻟﻨﺸﺎﻁ‬ ‫ﺭﻗﻢ ﺍﻟﻨﺸﺎﻁ‬ ‫ﺇﺳﻢ ﺍﻟﻨﺸﺎﻁ‬ ‫ﺭﻗﻢ ﺍﻟﻨﺸﺎﻁ‬


‫ﺍﻋﻤﺎﻝ ﺗﺮﻛﻴﺐ ﻧﻈﻢ ﻣﻜﻴﻔﺎﺕ ﺍﻟﻬﻮﺍﺀ‬ ‫‪457110‬‬ ‫ﺍﻟﺘﺠﺎﺭﻩ ﻓﻰ ﻗﻄﻊ ﻏﻴﺎﺭ ﺍﻟﻤﻜﻴﻔﺎﺕ ﻭ ﺍﺟﻬﺰﻩ‬ ‫‪1514211‬‬
‫ﻭﺍﻟﺘﺪﻓﺌﺔ ﻭﺻﻴﺎﻧﺘﻬﺎ‬ ‫ﺍﻟﺘﺒﺮﻳﺪ‬
‫ﺍﻟﺘﺠﺎﺭﻩ ﻓﻰ ﺍﺟﻬﺰﻩ ﺗﻨﻘﻴﻪ ﺍﻟﻬﻮﺍﺀ‬ ‫‪545910‬‬ ‫ﺍﻟﺘﺠﺎﺭﻩ ﻓﻰ ﺍﺟﻬﺰﻩ ﺍﻟﺘﺒﺮﻳﺪ ﻭ ﺍﻟﺘﺪﻓﺌﻪ‬ ‫‪531100‬‬
‫ﺗﺠﺎﺭﺓ ﺍﺟﻬﺰﺓ ﺍﻻﻃﻔﺎﺀ ﻭﺍﻻﻧﺬﺍﺭ‬ ‫‪2004338‬‬ ‫)ﺍﻟﻤﻜﻴﻔﺎﺕ(‬
‫ﻭﺍﻟﺴﻼﻣﺔ‬ ‫ﺍﻧﺸﺎﺀﺍﺕ ﻋﺎﻣﻪ )ﻣﻘﺎﻭﻻﺕ ﻋﺎﻣﻪ(‬ ‫‪452000‬‬

‫ﻣﺪﻳﺮ ﺇﺩﺍﺭﺓ ﺍﻟﺘﺴﺠﻴﻞ ﻭﺍﻟﺘﺮﺍﺧﻴﺺ ﺍﻟﺘﺠﺎﺭﻳﺔ‬


3. Company Legal Documents (CR, ISO,
Certificates)
4. Scope of Work
MOTORIZED VOLUME CONTROL DAMPERS MATERIALS LIST
SL. MATERIAL LOCATION TYPE MODEL
NO.
1 MOTORIZED INSIDE MOTORIZED SPK-30- 400-
VOLUME BUILDING, VOLUME CONTROL OB-B-A
CONTROL ROOF, PLANT DAMPERS (LOW
DAMPERS ROOM LEAKAGE)
SUPPLY of HVAC DUCT ACCESSORIES
5. Technical Compliance Statement
QCS 2014 Section 22: Air Conditioning, Refrigeration and Ventilation Page 9
Part 06: Ductwork and Air-Side Equipment

6.3.2 Flow Control Dampers

1 These dampers shall be installed in ductwork to maintain a constant air flow regardless of
changes of pressure conditions. The damper shall be suitable for duct velocities ranging
between 2 m/s to 8 m/s and shall operate from a minimum pressure of 20 Pa up to a
maximum of 200 Pa. These dampers shall be installed in branch ducts fitted with high
efficiency particle (HEPA) filters.

6.3.3 Motorised Dampers

1 The Contractor shall furnish and install, control dampers as required for the proper
functioning of the system.

2 All control dampers shall he opposed blade.

3 Dampers frames shall be formed channels of not less than 1.8 mm galvanized steel with
mounting holes for enclosed duct mounting.

4 Damper blades shall be of not less than 1.5 mm form galvanized steel. Blades on multi-
blade dampers shall not exceed 200 mm in width and 1200 mm in length. Blade shaft
bearings shall be provided at the ends of each blade. Blade side edges shall seal off against
spring stainless steel seals.

5 Dampers shall be supplied in standard sizes, in 50 mm even increments, with transition as


necessary to mating duct sections.

6 Dampers shall be suitable for operation within the temperature limit of – 40 C to 93 C.
Horizontal dampers shall have a rated face velocity of 2 m/s at 1500 Pa static pressure
differential.

7 Dampers used for shut off function shall be of the low leakage type.

8 Damper blades shall have neoprene or PVC edging on all outside air dampers.

6.3.4 Backdraft Dampers

1 Backdraft dampers shall be low leakage with parallel blades and neoprene edge seals.

2 Damper frames shall be constructed from galvanized sheet steel with aluminium blades.
Bearing shafts shall be stainless steel, in brass bearings.

3 All blades shall be coupled at the blade centres and shall be in width of not more than 1000
mm, with maximum blade size of 200 mm.

3 2
4 Leakage shall not exceed 10 m /h per m at 1000 Pa pressure differential.

5 Pressure relief dampers shall be multi-parallel blade with weighted arm closing assist. The
frame shall be anodised aluminium channel sections with formed aluminium blades.
Maximum blade length shall be 100 mm, and polyester foam seating strips shall be
incorporated on blade edges. Bearing shall be in PVC with non-corrodible shafts.
LIST OF PROPOSED MATERIAL

Motorized Volume Control Dampers (Low Leakage)


Frame : 16 Gauge galvanized steel G90
Blades : Double Skin Gal Steel , G90
Seals : Blade tip Seal & S/S Jamb Seals
Bearing : Brass Bushing
Actuator : Actuator, 230V, ON/OFF type
Country of
S. # MODEL No Brand
Origin
1 SPK-30- 400-OB-B-A SAFID QATAR

1/1
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series
( Flange Type )

SPK 30 - 400 Standard Construction


FRAME:
160mm x 30mm x 1.8mm galvanized steel formed channel
for flange connection.

BLADES:
100mm, 125mm and 150mm wide airfoil shaped blades

FINISH:
Frame of mill galvanized.
Blades of mill galvanized.

EXTERNAL LINKAGE:
Galvanized steel side linkage concealed in frame for opposed
blade operation.

CASE BEARING:
Brass bearing as standard.
Sintered bronze oilite (optional).

CONTROL SHAFT:
Description 12mm diameter zinc plated mild steel.
SPK 30-400 Class 1A & Class 1 Low Leakage Volume Control
Dampers are recommended for use in multiple Air Conditioning Units TIP SEAL
with one common air duct system on which one or two A/C Units Bubble type seal.
needs to be isolated during standby mode while the other A/C Unit is For Alr Leakage "Class 1A" and "Class 1".
on operational mode.
SIDE SEAL (Jamb Seal):
In building pressurization it can be used as an isolation damper to
maintain the required pressure in the space. Compression type stainless steel grade 304 to close
gap between frame and blades.
In office buildings where some occupants are outside most of the
time, this type of damper is recommended to shutdown the flow of air
MINIMUM & MAXIMUM SINGLE SECTION SIZE:
when the space is unoccupied on which can save energy
consumption.
100 x 100mm minimum and 900 x 900mm maximum.

It is also being used as a fresh air intake damper for Air Conditioning
Units where it needs a fresh air damper to be closed upon detection
of heavy dust on the fresh air side.
SPK 30 - 410
The blades with airfoil construction provides a low pressure drop in
the open position for smooth airflow and reduced air turbulence.
General construction as type SPK 30-400 damper but with
frame, linkage, case bearing, axles and control shaft are from
stainless steel (Grade 304).

SAFID certifies that the Class 1A & Class 1 Low Leakage Volume Control Damper
shown herein is licensed to bear the AMCA Seal for Model SPK 30-400. The ratings
shown are based on tests and procedures performed in accordance with AMCA
Publication 511 and comply with the requirements of the AMCA Certified Ratings
Program.
The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance Ratings.
Test Information
Tested for air leakage in accordance with ANSI / AMCA Standard 500-D-07,
Figure 5.4. Air leakage is based on operation between 32 ºF and 120 ºF.
Tested for air performance in accordance with ANSI / AMCA Standard 500-D-07
(Pressure Drop), Figure 5.3.
Catalog ID: SPK 30-400 January 23, 2014
Only 150mm blade width is AMCA certified.

Right to alterations reserved.

1
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series

Air Leakage Performance

Air Leakage Data

36 in. x 36 in. Allowable Air Leakage


( 914mm x 914mm ) To Achieve Leakage Classification
( Face Area = 9 ft² ) ( cfm/ft² )
Static Pressure Leakage Air Leakage Leakage at 1 in. at 2 in. at 4 in. at 6 in. at 12 in.
( in. W.G. ) ( cfm/ft² ) Classification Class W.G. W.G. W.G. W.G. W.G.
1 2.336 Class 1A 1A 3 N/A N/A N/A N/A
2 3.549 Class 1 1 4 5.6 8 9.8 13.8
4 5.498 Class 1 2 10 14 20 24.5 34.6
6 6.646 Class 1 3 40 56.5 80 98 138.5
12 9.796 Class 1

Data are based on a torque of 24.6 in.-lb/ft2 applied to close and seat the damper during the test.

SAFID certifies that the Class 1A & Class 1 Low Leakage Volume Control Damper shown
herein is licensed to bear the AMCA Seal for Model SPK 30-400. The ratings shown are
based on tests and procedures performed in accordance with AMCA Publication 511 and
comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance Ratings.
Test Information
Tested for air leakage in accordance with ANSI / AMCA Standard 500-D-07,
Figure 5.4. Air leakage is based on operation between 32 ºF and 120 ºF.
Tested for air performance in accordance with ANSI / AMCA Standard 500-D-07
(Pressure Drop), Figure 5.3.
Only 150mm blade width is AMCA certified.
Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

2
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series

Air Performance
Pressure Drop

AMCA Test Figure 5.3

Pressure Drop at Face Area Velocity


Damper Size: 12in. x 12in. - Fully open blades

SAFID certifies that the Class 1A & Class 1 Low Leakage Volume Control Damper shown
herein is licensed to bear the AMCA Seal for Model SPK 30-400. The ratings shown are
based on tests and procedures performed in accordance with AMCA Publication 511 and
comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance Ratings.
Test Information
Tested for air leakage in accordance with ANSI / AMCA Standard 500-D-07,
Figure 5.4. Air leakage is based on operation between 32 ºF and 120 ºF.
Tested for air performance in accordance with ANSI / AMCA Standard 500-D-07
(Pressure Drop), Figure 5.3.
Only 150mm blade width is AMCA certified.
Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

3
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series

Air Performance
Pressure Drop

AMCA Test Figure 5.3

Pressure Drop at Face Area Velocity


Damper Size: 24in. x 24in. - Fully open blades

SAFID certifies that the Class 1A & Class 1 Low Leakage Volume Control Damper shown
herein is licensed to bear the AMCA Seal for Model SPK 30-400. The ratings shown are
based on tests and procedures performed in accordance with AMCA Publication 511 and
comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance Ratings.
Test Information
Tested for air leakage in accordance with ANSI / AMCA Standard 500-D-07,
Figure 5.4. Air leakage is based on operation between 32 ºF and 120 ºF.
Tested for air performance in accordance with ANSI / AMCA Standard 500-D-07
(Pressure Drop), Figure 5.3.
Only 150mm blade width is AMCA certified.
Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

4
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series

Air Performance
Pressure Drop

AMCA Test Figure 5.3

Pressure Drop at Face Area Velocity


Damper Size: 36in. x 36in. - Fully open blades

SAFID certifies that the Class 1A & Class 1 Low Leakage Volume Control Damper shown
herein is licensed to bear the AMCA Seal for Model SPK 30-400. The ratings shown are
based on tests and procedures performed in accordance with AMCA Publication 511 and
comply with the requirements of the AMCA Certified Ratings Program.
The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance Ratings.
Test Information
Tested for air leakage in accordance with ANSI / AMCA Standard 500-D-07,
Figure 5.4. Air leakage is based on operation between 32 ºF and 120 ºF.
Tested for air performance in accordance with ANSI / AMCA Standard 500-D-07
(Pressure Drop), Figure 5.3.
Only 150mm blade width is AMCA certified.
Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

5
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series
Dimensions
1 - Casing 3 - Side Linkage 5 - Tip Seal 7 - Bearing
2 - Actuator 4 - Blade 6 - Side Seal (Jamb Seal) 8 - Landing Angles

Flange Type Flange Type

Flange Type, Opposed Blades Standard Sizes

WIDTH HEIGHT NUMBER OF BLADES FOR


( mm ) ( mm )
100mm 125 mm 150mm
150 100 1 - -
200 150 - - 1
200 200 2 - -
250 250 - 2 -
300 300 - - 2
350 350 1 2 -
400 400 1 - 2
450 450 - - 3
500 500 2 - 2
550 550 - 2 2
600 600 - - 4
650 650 2 - 3
700 700 1 - 4
750 750 - - 5
800 800 2 - 4
850 850 1 - 5
900 900 - - 6

Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

6
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series

Materials - Construction

Axle and Drive Shaft fixing details Mounting Bracket for Actuator

Blade Seal Side Seal or Jamb Seal

Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

7
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series
Installation Details
Damper to Slide on Flange connection Damper to Angle Flange connection

Flange Drilling Details


Flange Drilling Details
Flange drilling details
W H No. of Holes No. of Holes
in mm in mm W Dim. H Dim.
150 150 2 2
200 150 2 2
300 300 3 3
400 300 4 3
500 300 4 3
450 450 4 4
500 450 4 4
600 450 5 4
700 450 6 4
800 450 7 4
900 450 8 4
600 600 5 5
700 600 6 5
800 600 7 5
900 600 8 5
750 750 6 5
800 750 7 5
900 750 8 5
900 900 8 8

Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

8
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series
Order Details

Order Code

SPK 30 - 400 - OB - B - R - 900 X 900 - A

Variants - Code Duct Size Actuator


SPK 30 - 400 S equivalent
SPK 30 - 410 Open-close control

Blade Operation
OB = Opposed Blades operation

External Controls
* R = Right hand (Standard Supply)
Variants - Bearings L = Left Hand
*B = Brass case bearing (Standard Supply)
B1 = Sintered bronze (oilite) case bearing

* - Stands for standard supply.

ORDER EXAMPLE
STANDARD
Make: SAFID
1. Type : SPK 30 - 400 - OB - B - R - 900 x 900 - A
2. Type : SPK 30 - 400 - OB - B1 - R - 900 x 900 - A

Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

9
OpenAir™

Air damper actuators


GSD...1A

Electric motor-driven rotary actuators for open-close, three-position


and modulating control

2 Nm nominal torque
Operating voltage AC 24 V ~ / DC 24…48 V or AC 100…240 V ~
Prewired with 0.9 m connecting cable
Gear train disengagement button for manual adjustment
Position indication
Auxiliary switches for auxiliary functions

30

A6V10636055_en--_e Siemens
2019-03-21 Building Technologies
Features
The rotary actuator drives the damper to the desired operating position after connecting the
operating voltage.
Brushless, robust DC motors ensure reliable operation regardless of load.
The rotary actuators do not require an end position switch, are overload proof, and remain
in place upon reaching the end stop.
The gears are maintenance free and low noise.
Simple and reliable shaft integration.
Mounting bracket included.

Use
Non-spring return rotary actuators. Application in ventilation and air conditioning plants to
operate air dampers and air throttles.
For damper areas up to 0.3 m 2, friction dependent.
Suitable for use with modulating controllers (DC 0/2...10 V), open-close or three-position
controllers.
For directly driven zone dampers to control air flow in air ducts.
We recommend a minimum pulse length of 500 ms on rotary actuators operated with
3-point control to ensure continuous and accurate operation.

Functions

AC 24 V ~ / GSD14..1A GSD16..1A
Type DC 24…48 V
AC 100…240 V ~ GSD34..1A GSD361.1A

Control type Open-close / three-position Modulating control


Rotary direction Clockwise (cw) or counter-clockwise (ccw) direction depends …
… on the type of control. … on the setting of the rotary direction DIL switch
… on the setting of the rotary cw ccw
direction switch.
cw ccw

… on the positioning signal.


The actuator remains in the achieved position:
With no power applied, the actuator
… if the control signal is maintained at a constant
remains in the respective position.
value
… for loss of operating voltage
Position indication: Rotary angle position indication by a position indicator/hand lever.
Mechanical
Position indication: • Output voltage U = DC 0/2...10 V is generated
Electrical proportional to the rotary angle.
• U depends on the rotary direction of the DIL
switch setting.
Auxiliary switches Fixed position 5° / 85°
Manual adjustment The actuator can be manually adjusted by pressing the gear train disengagement
button.

2 / 10
Siemens A6V10636055_en--_e
Building Technologies 2019-03-21
Technical design/mechanical design
Housing
The housing consists essentially of flame retardant, non brominated, non chlorinated glass
fibre reinforced plastic.

Type summary

Type Stock number Control Operating Positioning Position Aux. Rotary Aux.
voltage signal Y indicator U = switches direction power supply
DC 0/2...10 V switch
GSD141.1A S55499-D281 AC 24 V ~ /
Open- DC 24…48 V
GSD146.1A S55499-D227 close 2
or three- yes
GSD341.1A S55499-D282
position AC 100…240 V ~
GSD346.1A S55499-D230 2
GSD161.1A S55499-D228 AC 24 V ~ / yes
GSD166.1A S55499-D229 Modulating DC 24…48 V DC 0/2...10 V yes 2 yes
GSD361.1A S55499-D231 AC 100…240 V ~ yes yes

Product documentation

Topic Title Document ID


Data sheet Air damper actuators GSD..1A A6V10636055_en--
Mounting instructions Rotary-type actuator GSD..1A A6V10636060_----

Related documents such as environmental declarations, CE declarations, etc., can be


downloaded at the following Internet address:
http://siemens.com/bt/download

Notes

Safety

Caution

National safety regulations


Failure to comply with national safety regulations may result in personal injury and property
damage.
Observe national provisions and comply with the appropriate safety regulations.
Use only properly trained technicians for mounting, commissioning, and servicing.

Engineering
Auxiliary switches
Auxiliary switches cannot be added in the field.

3 / 10
A6V10636055_en--_e Siemens
2019-03-21 Building Technologies
Technical data

Power supply GSD14..1A / GSD16..1A


Operating voltage (SELV/PELV) / Frequency AC 24 V ~ ±20 % (19.2…28.8 V ~) / 50/60 Hz
1)
DC 24…48 V ±20 % (19.2…57.6 V )
Power consumption running GSD14..1A 2.2 VA / 1.2 W
GSD16..1A 2.4 VA / 1.4 W
Power consumption holding GSD14..1A 1 VA / 0.5 W
GSD16..1A 1.2 VA / 0.7 W

Power supply GSD34..1A / GSD361.1A


Operating voltage / Frequency AC 100…240 V ~ ±10 % (90…264 V ~) / 50/60 Hz
Power consumption running GSD34..1A 4.5 VA / 1.8 W
GSD361.1A 3.7 VA / 1.4 W

Power consumption holding GSD34..1A 2.4 VA / 0.9 W


GSD361.1A 1.6 VA / 0.5 W

Functional data
Nominal torque 2 Nm
Maximum torque 5 Nm
Nominal rotational angle 90°
Maximum rotational angle (mechanically limited) 95° ± 2°
Runtime at nominal rotational angle 90° 30 s
Duty cycle 100 %
Direction of rotation Clockwise / counterclockwise
Mechanical life 100 000 cycles
Actuator sound power level 35 dB(A)

Inputs
Positioning signal for GSD14..1A
Operating voltage (wires 1-6/G-Y1) clockwise
AC 24 V ~ / DC 24…48 V (wires 1-7/G-Y2) counterclockwise
Positioning signal for GSD34..1A
Operating voltage (wires 4-6/N-Y1) clockwise
AC 100…240 V ~ (wires 4-7/N-Y2) counterclockwise
Positioning signal for GSD16..1.A
Input voltage (wires 8-2/Y-G0) DC 0/2…10 V
Current consumption 0.1 mA
Input resistance >100 k

Outputs
Position indicator
Output signal (GSD16..1.A) (wires 9-2/U-G0)
Output signal (GSD361.1.A) (wires 9-2/U-G-)
Output voltage U DC 0...10 V
Max. output current DC ±1 mA
Protected against faulty wiring max. AC 24 V ~ / DC 24…48 V
Aux. power supply (GSD361.1A) (wires 1-2/G+-G-) DC 24 V ±20 %, max. 10 mA

Auxiliary switches
Switching voltage AC 24…250 V ~ / DC 12…30 V
Contact rating 6 A resistive, 2 A inductive, min. 10 mA @ AC
4 A resistive, 2 A inductive, min. 10 mA @ DC 30 V
0.8 A res., 0.5 A inductive, min. 10 mA @ DC 60 V
Electric strength auxiliary switches against housing AC 4 kV
Factory switches setting: Switch A / Switch B 5° / 85° (fixed position)

5 / 10
A6V10636055_en--_e Siemens
2019-03-21 Building Technologies
Connection cables
Cable length 0.9 m
2
Cross-section 0.75 mm

Degree of protection
Insulation protective class As per EN 60730
AC 24 V ~ / DC 24…48 V III
AC 100…240 V ~ II
Housing protection IP54 as per EN 60529

Environmental conditions
Operation IEC 60721-3-3
Climatic conditions Class 3K5
Mounting location Interior, weather-protected
Temperature (extended) -32...+55 °C
Humidity, non-condensing <95 % r.F.
Transportation IEC 60721-3-2
Climatic conditions Class 2K3
Temperature (extended) -32...+70 °C
Humidity, non-condensing <95 % r.F.
Storage IEC 60721-3-1
Climatic conditions Class 1K3
Temperature (extended) -32...+50 °C
Humidity, non-condensing <95 % r.F.
Mechanical conditions Class 2M2

Standards, directives and approvals


Product standard EN 60730
Part 2-14 / Particular requirements for electric actuators
Electromagnetic compatibility For use in residential, commerce, light-industrial and
(Applications) industrial environments
2)
EU Conformity (CE) A5W00004362
2)
RCM Conformity A5W00004363
EAC Conformity Eurasian conformity
UL UL as per UL 60730 http://ul.com/database
1)
cUL as per CSA-C22.2 No. 24-93

Environmental compatibility
2)
The product environmental declaration A5W00030346-A contains data on environmentally compatible product
design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal).

Dimensions
Actuator W x H x D See "Dimensions” p. 9
Damper shaft
round 8…15 mm
Square 6…11 mm
Min. shaft length 20 mm
Shaft hardness <300 HV

Weight
Excl. packaging Max. 0.55 kg, without switches
Max. 0.7 kg, with switches

1)
Permitted only to DC 30 V
2)
The documents can be downloaded from http://siemens.com/bt/download.

6 / 10
Siemens A6V10636055_en--_e
Building Technologies 2019-03-21
Diagrams

Internal Diagrams

GSD14..1A (Open-close, three-p.) GSD34..1A (Open-close, three-p.)

AC 24 V ~ / DC 24…48 V AC 100…240 V ~

III
AC 24 V ~ AC 24...250 V ~ / 6 (2) A AC 24...250 V ~ / 6 (2) A
DC 24...48 V DC 12...30 V / 2 A AC 100...240 V ~ DC 12...30 V / 2 A
1 S1 S4 6 7 S1 S4

M 1) 1)
M

6 7 S2 S3 S5 S6 4 S2 S3 S5 S6
N

GSD16..1A (Modulating control) GSD361.1A (Modulating control)

AC 24 V ~ / DC 24…48 V AC 100…240 V ~

III AC 24 V ~ AC 24...250 V ~ / 6 (2) A SELV/PELV


DC 24...48 V DC 0/2...10 V DC 12...30 V / 2 A DC 24 V DC 0/2...10 V
AC 100...240 V ~
1 8 3 1 8

100%
1) 100%
M M
0% 0%

G0 U N G-
2 9 4 2 9
N
DC 0/2...10 V DC 0/2...10 V

1)
Actuator Switch A Switch B
Position Common S1 Common S4
connected to connected to
0°…5° S3 S6
5°…85° S2 S6
85°…90° S2 S5

7 / 10
A6V10636055_en--_e Siemens
2019-03-21 Building Technologies
Connection diagrams

GSD1..1A (AC 24 V ~ / DC 24…48 V )

Open-close, single wire control Open-close, two wire control Three-position control Modulating control
Single Pole Single Throw (SPST) Single Pole Double Throw (SPDT)
AC 24 V ~ AC 24 V ~ AC 24 V ~ AC 24 V ~
DC 24...48 V DC 24...48 V DC 24...48 V DC 24...48 V

G G G

Y1 Y2 Y1 Y2 Y1 Y2 G Y U

G0

AC 24 V ~ AC 24 V ~ AC 24 V ~
DC 24...48 V DC 24...48 V DC 24...48 V

Y1 Y2 Y1 Y2 Y1 Y2

G G G

GSD3..1A (AC 100…240 V ~)

Open-close, single wire control Open-close, two wire control Three-position control Modulating control
Single Pole Single Throw (SPST) Single Pole Double Throw (SPDT)

AC 100...240 V ~ AC 100...240 V ~ AC 100...240 V ~ AC 100...240 V ~

Y1 Y2 Y1 Y2 Y1 Y2 L G+ Y U

N N N N G-

N N N N

Cable labeling

Connection Code No Color Abbreviation Meaning


Actuators G 1 red RD System potential AC 24 V ~ / DC 24…48 V
AC 24 V ~ G0 2 black BK System neutral
DC 24…48 V Y1 6 purple VT Positioning signal AC/DC 0 V, “clockwise” (GSD14..1A)
Y2 7 orange OG Positioning signal AC/DC 0 V, “counterclockwise” (GSD14..1A)
Y 8 grey GY Signal in (GSD16..1A)
U 9 pink PK Signal out (GSD16..1A)
Actuators L 3 brown BR Line AC 100…240 V ~
AC 100…240 V ~ N 4 light blue BU Neutral conductor
Y1 6 black BK Positioning signal AC 100…240 V ~, “clockwise” (GSD34..1A)
Y2 7 white WH Positioning signal AC 100…240 V ~, “counterclockwise” (GSD34..1A)
G+ 1 red RD System potential DC 24 V (GSD361.1A)
G- 2 black BK System neutral (GSD361.1A)
Y 8 grey GY Signal in (GSD361.1A)
U 9 pink PK Signal out (GSD361.1A)
Auxiliary switch Q11 S1 grey/red GY RD Switch A input
Q12 S2 grey/blue GY BU Switch A normally open contact
Q14 S3 grey/pink GY PK Switch A normally closed contact
Q21 S4 black/red BK RD Switch B input
Q22 S5 black/blue BK BU Switch B normally open contact
Q24 S6 black/pink BK PK Switch B normally closed contact

8 / 10
Siemens A6V10636055_en--_e
Building Technologies 2019-03-21
Dimensions

Dimensions in mm

9 / 10
A6V10636055_en--_e Siemens
2019-03-21 Building Technologies
s

OpenAir™

Air damper actuators


GDB..1E

Electronic motor driven actuators for open-close, three-position


and modulating control

● Nominal torque 5 Nm
● Operating voltage AC 24 V ~ / DC 24…48 V ⎓ or AC 100…240 V ~
● Mechanically adjustable span between 0...90°
● Pre-wired with 0.9 m long connection cables
● Type-specific variations with adjustable offset and span for
the positioning signal
● Position indication: mechanical and electrical
● Feedback potentiometer
● Self-adaption of rotational angle range and adjustable auxiliary switches for
supplementary functions

30

A6V10636149_en--_b Siemens
2016-12-14 Building Technologies
Use
The rotary actuators are used in ventilation and air conditioning plants to regulate and shut
off air dampers:
● For damper areas up to 0.8 m2 (guideline, always observe damper manufacturer’s data).
● Suitable for use with modulating controllers (DC 0/2...10 V), open-close or three-position
controllers for air dampers or air throttles.
● We recommend a minimum pulse length of 500 ms on rotary actuators operated with 3-
point control to ensure continuous and accurate operation.

Functions

AC 24 V ~ / 141.1E / 142.1E / 146.1E 161.1E / 163.1E / 164.1E / 166.1E


GDB.. DC 24…48 V ⎓
AC 100…240 V ~ 341.1E / 346.1E 361.1E
Control type Open-close / three-position Modulating control (0/2…10 V)
Rotary direction Clockwise or counter-clockwise direction depends …
… on the type of control … on the setting of the rotary direction DIL
… on the setting of the rotary direction switch
switch. cw ccw
cw ccw 2... 2...

GD..1ERW_Z08
GD..1E_Z06

0... 0 0... 0

With no power applied, the actuator … on the positioning signal.


remains in the respective position. The actuator remains in the achieved
position:
… if the control signal is maintained at a
constant value
… for loss of operating voltage.
Position indication: Rotary angle position indication by using a position indicator.
Mechanical
Position indication: The feedback potentiometer can be Output voltage U = DC 0/2...10 V is
Electrical connected to external voltage to generated proportional to the rotary angle.
indicate the position. U depends on the rotary direction of the
DIL switch setting.
Auxiliary switch The switching points for auxiliary switches A and B can be set independent of each
other in increments of 5° within 0° to 90°.
Self-adaptation of linear When self-adaptation is active, the
span actuator automatically determines the
mechanical end positions of the linear
span and maps the characteristic function
(Uo, DU) to the calculated linear span.
Manual adjustment The actuator can be manually adjusted by pressing the gear train disengagement
button.
Rotary angle limitation The rotary angle of the shaft adapter can be limited mechanically with a set screw.

Technical design

Housing
The housing consists essentially of flame retardant, non brominated, non chlorinated glass
fibre reinforced plastic.

2 / 10
Siemens A6V10636149_en--_b
Building Technologies 2016-12-14
Actuator motor / Gears
● Brushless, robust DC motors ensure reliable operation regardless of load. The damper
actuators do not require an end position switch, are overload proof, and remain in place
upon reaching the end stop.
● The gears are maintenance free and low noise.

Type summary

Type Stock no. Control Operating Positioning Position Feedback Self-adaption Aux. Rotary
voltage signal Y indicator U = potentio- of rotational switches direction
DC 0…10 V ⎓ meter 5 kΩ angle range switch

GDB141.1E S55499-D184 ‒
Open- AC 24 V ~ / ‒
GDB142.1E S55499-D185 yes
close DC 24…48 V ⎓
GDB146.1E S55499-D186 or ‒ ‒ ‒ 2 yes
three-
GDB341.1E S55499-D187 ‒ ‒
position AC 100…240 V ~
GDB346.1E S55499-D188 2

GDB161.1E S55499-D266 DC 0/2...10 V ⎓ yes yes



GDB163.1E S55499-D267 AC 24 V ~ / DC 0...35 V ⎓ yes yes
Modu-
GDB164.1E S55499-D268 DC 24…48 V ⎓ DC 0...35 V ⎓ yes ‒ yes yes
lating 2
GDB166.1E S55499-D269 DC 0/2...10 V ⎓ yes yes
GDB361.1E S55499-D189 AC 100…240 V ~ DC 0/2...10 V ⎓ yes yes ‒

Nominal torque: 5 Nm (applies to all GDB..1E actuators)

Accessories
See data sheet N4698

Product documentation

Topic Title Document ID


Data sheet Air damper actuators A6V10636149_en--_a
Technical basics Rotary damper actuators without spring return GD..E A6V10636139_en--_a
Mounting instructions GDB..1E, GLB..1E A6V10636143_----_a

Related documents such as environmental declarations, CE declarations, etc., can be down-


loaded at the following Internet address:
http://siemens.com/bt/download

Notes

Safety

Caution

National safety regulations


Failure to comply with national safety regulations may result in personal injury and property
damage.
● Observe national provisions and comply with the appropriate safety regulations.
● Use only properly trained technicians for mounting, commissioning, and servicing.

3 / 10
A6V10636149_en--_b Siemens
2016-12-14 Building Technologies
Engineering
Potentiometer and auxiliary switches
Potentiometer and auxiliary switches cannot be added in the field

Installation

WARNING

No internal line protection for supply lines to external consumers


Risk of fire and injury due to short-circuits
● Adapt the line diameters as per local regulations to the rated value of the installed fuse.

Maintenance

The actuators GDB..1E are maintenance-free.

Disposal

The device is considered an electronics device for disposal in terms of Eu-


ropean Directive 2012/19/EU and may not be disposed of as domestic gar-
bage.
● Dispose of the device through channels provided for this purpose.
● Comply with all local and currently applicable laws and regulations..

Technical data

Power supply (GDB1..1E)


Operating voltage (SELV/PELV) / Frequency AC 24 V ~ ±20 % (19.2…28.8 V ~) / 50/60 Hz
1)
DC 24…48 V ⎓ ±20 % (19.2…57.6 V ⎓)
Power consumption running GDB14..1E, 2 VA / 1 W
GDB16..1E 2.1 VA / 1.2 W
Power consumption holding GDB14..1E, 0.5 W
GDB16..1E 0.7 W

Power supply (GDB3..1E)


Operating voltage / Frequency AC 100…240 V ~ ±10 % (90…264 V ~) / 50/60 Hz
Power consumption running GDB34..1E, 5 VA / 1.6 W
GDB36..1E 3.3 VA / 1.2 W
Power consumption holding GDB34..1E, 0.9 W
GDB36..1E 0.5 W

Function data
Nominal torque 5 Nm
Maximum torque (blocked) 10 Nm
Minimum holding torque 5 Nm
Nominal rotary angle (with position indication) 90°
Maximum rotary angle (mechanic limitation) 95° ± 2°
Runtime for 90° rotary angle 150 s
Actuator sound power level 28 dB(A)

1)
C-UL: Permitted only to DC 30 V ⎓

4 / 10
Siemens A6V10636149_en--_b
Building Technologies 2016-12-14
Inputs
Positioning signal for GDB14..1E
Operating voltage (wires 1-6/G-Y1) clockwise
AC 24 V ~ / DC 24…48 V ⎓ (wires 1-7/G-Y2) counterclockwise
Positioning signal for GDB34..1E
Operating voltage (wires 4-6/N-Y1) clockwise
AC 100…240 V ~ (wires 4-7/N-Y2) counterclockwise
Positioning signal for GDB16..1.E
Input voltage (wires 8-2/Y-G0) DC 0/2…10 V ⎓
Current consumption 0.1 mA
Input resistance >100 kW
Max. permissible input voltage DC 35 V ⎓ limited to DC 10 V ⎓
Protected against faulty wiring max. AC 24 V ~ / DC 24…48 V ⎓
Hysteresis for non-adjustable characteristic function 60 mV
for adjustable characteristic function 0.6 % of ∆U
Adjustable characteristic function (GDB163.1E, GDB164.1E)
Adjustable with 2 potentiometers: Offset Uo DC 0…5 V ⎓
Span ∆U DC 2…30 V ⎓
Max. input voltage DC 35 V ⎓
Protected against faulty wiring max. AC 24 V ~ / DC 24…48 V ⎓

Outputs
Position indicator
Output signal (GDB16..1E) (wires 9-2/U-G0)
Output signal (GDB36..1E) (wires 9-2/U-G-)
Output voltage U DC 0...10 V ⎓
Max. output current DC ±1 mA
Protected against faulty wiring max. AC 24 V ~ / DC 24…48 V ⎓
Aux. power supply (G- / G+)
GDB36.. DC 24 V ⎓ ±20 %, max. 10 mA
Feedback potentiometer (for GDB142.1E)
Change of resistance (wires P1-P2) 0…5000 W
Load <0.25 W
Max. sliding contact current <10 mA
Permissible voltage at potentiometer (SELV/PELV) AC 24 V ~ / DC 24…48 V ⎓
Insulation resistance between potentiometer and
housing AC 500 V ~

Auxiliary switches (GDB146.1E, GDB166.1E, GDB346.1E)


Switching voltage AC 24…250 V ~ / DC 12…30 V ⎓
Contact rating 6 A resistive, 2 A inductive, min. 10 mA @ AC
4 A resistive, 2 A inductive, min. 10 mA @ DC 30 V ⎓
0.8 A res., 0.5 A inductive, min. 10 mA @ DC 60 V ⎓
Electric strength auxiliary switch against housing AC 4 kV
Switching range for auxiliary switches / setting increments 5°…90° / 5°
Factory switch setting: Switch A 5°
Switch B 85°

Connection cables
Cable length 0.9 m
2
Cross section of prewired connection cables 0.75 mm
Permissible length for signal lines 300 m

Degree of protection
Insulation class As per EN 60730
AC 24 V ~ / DC 24…48 V ⎓, feedback potentiometer III
AC 100…240 V ~, auxiliary switches II
Housing protection IP 54 as per EN 60529

5 / 10
A6V10636149_en--_b Siemens
2016-12-14 Building Technologies
Environmental conditions
Operation IEC 60721-3-3
Climatic conditions Class 3K5
Mounting location interior, weather-protected
Temperature extended -32…+55 °C
Humidity (non-condensing) <95 % r.F.
Transport IEC 60721-3-2
Climatic conditions Class 2K3
Temperature extended -32…+70 °C
Humidity (non-condensing) <95 % r.F.
Storage IEC 60721-3-1
Climatic conditions Class 1K3
Temperature extended -32…+50 °C
Humidity (non-condensing) <95 % r.F.
Mechanical conditions Class 2M2

Standards, directives and approvals


Product standard EN 60730
Part 2-14 / Particular requirements for electric
actuators
Electromagnetic compatibility For use in residential, commercial, light-industrial
(Applications) and industrial environments
2)
EU Conformity (CE) A5W00003842
2)
RCM Conformity A5W00003843
EAC Conformity Eurasian conformity
UL UL as per UL 60730 http://ul.com/database
cUL as per CSA-C22.2 No. 24-93

Environmental compatibility
2)
The product environmental declaration A5W00026066 contains data on environmentally compatible product
design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal).

Dimensions
Actuator W x H x D see „Dimensions“, p. 9
Damper shaft
round 8…16 mm
round 8…10 mm (with centering element)
Square 6…12.8 mm
Min. shaft length 20 mm
Shaft hardness <300 HV

Weight
Without packaging Max. 0.49 kg, without switches
Max. 0.63 kg, with switches

2)
The documents can be downloaded from http://siemens.com/bt/download.

6 / 10
Siemens A6V10636149_en--_b
Building Technologies 2016-12-14
Diagrams

Internal Diagrams
GDB14..1E (open-close, three-p.) GDB34..1E (open-close, three-p.)

AC 24 V ~ / DC 24…48 V ⎓ AC 100…240 V ~

GDB16..1E (modulating, Y= DC 0/2…10 V ⎓) GDB16..1E (modulating, Y= DC 0…35 V ⎓) GDB361.1E (modulating control)

AC 24 V ~ / DC 24…48 V ⎓ AC 24 V ~ / DC 24…48 V ⎓ AC 100…240 V ~

Connection diagrams
GDB1..1E (AC 24 V ~ / DC 24…48 V ⎓)

Open-close, single wire control Open-close, two wire control Three-position control Modulating control
Single Pole Single Throw (SPST) Single Pole Double Throw (SPDT)

7 / 10
A6V10636149_en--_b Siemens
2016-12-14 Building Technologies
GDB3.. 1E (AC 100…240 V ~)

Open-close, single wire control Open-close, two wire control Three-position control Modulating control
Single Pole Single Throw (SPST) Single Pole Double Throw (SPDT)

Cable labeling

Connection Code No Color Abbreviation Meaning


Actuators G 1 red RD System potential AC 24 V ~ / DC 24…48 V ⎓
AC 24 V ~ G0 2 black BK System neutral
DC 24…48 V ⎓ Y1 6 purple VT Positioning signal AC/DC 0 V, “clockwise” (GDB14..1E)
Y2 7 orange OG Positioning signal AC/DC 0 V, “counter-clockwise”
(GDB14..1E)
Y 8 grey GY Signal in (GDB16..1E)
U 9 pink PK Signal out (GDB16..1E)
Actuators L 3 brown BR Line AC 100…240 V ~
AC 100…240 V ~ N 4 light blue BU Neutral conductor
Y1 6 black BK Positioning signal AC 100…240 V ~, “clockwise”
(GDB34..1E)
Y2 7 white WH Positioning signal AC 100…240 V ~, “counter-
clockwise” (GDB34..1E)
G+ 1 red RD System potential DC 24 V ⎓ (aux. power supply)
(GDB361.1E)
G- 2 black BK System neutral (aux. power supply) (GDB361.1E)
Y 8 grey GY Signal in (GDB361.1E)
U 9 pink PK Signal out (GDB361.1E)
Feedback a P1 white/red WH RD Potentiometer 0…100 % (P1-P2)
potentiometer b P2 white/blue WH BU Potentiometer pick-off
c P3 white/pink WH PK Potentiometer 100…0 % (P3-P2)
Auxiliary switch Q11 S1 grey/red GY RD Switch A input
Q12 S2 grey/blue GY BU Switch A normally closed contact
Q14 S3 grey/pink GY PK Switch A normally open contact
Q21 S4 black/red BK RD Switch B input
Q22 S5 black/blue BK BU Switch B normally closed contact
Q24 S6 black/pink BK PK Switch B normally open contact

8 / 10
Siemens A6V10636149_en--_b
Building Technologies 2016-12-14
Dimensions

2.7
x

4.5

max 95°

68
50

min. 6
4634M01

min. 60

min.
Dimensions in mm

Revision numbers

Type Valid from rev. no. Type Valid from rev. no.
GDB141.1E ..B GDB164.1E ..B
GDB142.1E ..B GDB166.1E ..B
GDB146.1E ..B GDB361.1E ..B
GDB161.1E ..B GDB341.1E ..B
GDB163.1E ..B GDB346.1E ..B

9 / 10
A6V10636149_en--_b Siemens
2016-12-14 Building Technologies
s

OpenAir™

Air damper actuators


GLB..1E

Electronic motor driven actuators for open-close, three-position


and modulating control

● Nominal torque 10 Nm
● Operating voltage AC 24 V ~ / DC 24…48 V ⎓ or AC 100…240 V ~
● Mechanically adjustable span between 0...90°
● Pre-wired with 0.9 m long connection cables
● Type-specific variations with adjustable offset and span for
the positioning signal
● Position indication: mechanical and electrical
● Feedback potentiometer
● Self-adaption of rotational angle range and adjustable auxiliary switches for
supplementary functions

30

A6V10636202_en--_b Siemens
2016-12-14 Building Technologies
Use
The rotary actuators are used in ventilation and air conditioning plants to regulate and shut
off air dampers:
● For damper areas up to 1.6 m2 (guideline, always observe damper manufacturer’s data).
● Suitable for use with modulating controllers (DC 0/2...10 V), open-close or three-position
controllers for air dampers or air throttles.
● We recommend a minimum pulse length of 500 ms on rotary actuators operated with 3-
point control to ensure continuous and accurate operation.

Functions

AC 24 V ~ /
141.1E / 142.1E / 146.1E 161.1E / 163.1E / 164.1E / 166.1E
GLB.. DC 24…48 V ⎓
AC 100…240 V ~ 341.1E / 346.1E 361.1E
Control type Open-close / three-position Modulating control (0/2…10 V)
Rotary direction Clockwise or counter-clockwise direction depends …
… on the type of control … on the setting of the rotary direction DIL
… on the setting of the rotary direction switch
switch. cw ccw
cw ccw 2... 2...

GD..1ERW_Z08
GD..1E_Z06

0... 0 0... 0

With no power applied, the actuator … on the positioning signal.


remains in the respective position. The actuator remains in the achieved
position:
… if the control signal is maintained at a
constant value
… for loss of operating voltage.
Position indication: Rotary angle position indication by using a position indicator.
Mechanical
Position indication: The feedback potentiometer can be Output voltage U = DC 0...10 V is
Electrical connected to external voltage to generated proportional to the rotary angle.
indicate the position. U depends on the rotary direction of the
DIL switch setting.
Auxiliary switch The switching points for auxiliary switches A and B can be set independent of each
other in increments of 5° within 0° to 90°.
Self-adaptation of linear When self-adaptation is active, the
span actuator automatically determines the
mechanical end positions of the linear
span and maps the characteristic function
(Uo, DU) to the calculated linear span.
Manual adjustment The actuator can be manually adjusted by pressing the gear train disengagement
button.
Rotary angle limitation The rotary angle of the shaft adapter can be limited mechanically with a set screw.

Technical design

Components
The housing consists essentially of flame retardant, non brominated, non chlorinated glass
fibre reinforced plastic.

2 / 10
Siemens A6V10636202_en--_b
Building Technologies 2016-12-14
Actuator motor / Gears
● Brushless, robust DC motors ensure reliable operation regardless of load. The damper
actuators do not require an end position switch, are overload proof, and remain in place
upon reaching the end stop.
● The gears are maintenance free and low noise.

Type summary

Type Stock no. Control Operating Positioning Position Feedback Self-adaption Aux. Rotary
voltage signal Y indicator U = potentio- of rotational switches direction
DC 0…10 V ⎓ meter 5 kΩ angle range switch

GLB141.1E S55499-D192 ‒
Open- AC 24 V ~ / ‒
GLB142.1E S55499-D193 yes
close DC 24…48 V ⎓
GLB146.1E S55499-D194 or ‒ ‒ ‒ 2 yes
three-
GLB341.1E S55499-D195 ‒ ‒
position AC 100…240 V ~
GLB346.1E S55499-D196 2

GLB161.1E S55499-D270 DC 0/2...10 V ⎓ yes yes



GLB163.1E S55499-D271 AC 24 V ~ / DC 0...35 V ⎓ yes yes
Modu-
GLB164.1E S55499-D272 DC 24…48 V ⎓ DC 0...35 V ⎓ yes ‒ yes yes
lating 2
GLB166.1E S55499-D273 DC 0/2...10 V ⎓ yes yes
GLB361.1E S55499-D197 AC 100…240 V ~ DC 0/2...10 V ⎓ yes yes ‒

Nominal torque: 10 Nm (applies to all GLB..1E actuators)

Accessories
See data sheet N4698

Product documentation

Topic Title Document ID


Data sheet Air damper actuators A6V10636202_en--_a
Technical basics Rotary damper actuators without spring return GL..E A6V10636196_en--_a
Mounting instructions GDB..1E, GLB..1E A6V10636143_----_a

Related documents such as environmental declarations, CE declarations, etc., can be down-


loaded at the following Internet address:
http://siemens.com/bt/download

Notes

Safety

Caution

National safety regulations


Failure to comply with national safety regulations may result in personal injury and property
damage.
● Observe national provisions and comply with the appropriate safety regulations.
● Use only properly trained technicians for mounting, commissioning, and servicing.

3 / 10
A6V10636202_en--_b Siemens
2016-12-14 Building Technologies
Engineering
Potentiometer and auxiliary switches
Potentiometer and auxiliary switches cannot be added in the field.

Installation

WARNING

No internal line protection for supply lines to external consumers


Risk of fire and injury due to short-circuits
● Adapt the line diameters as per local regulations to the rated value of the installed fuse.

Maintenance

The actuators GLB..1E are maintenance-free.

Disposal

The device is considered an electronics device for disposal in terms of Eu-


ropean Directive 2012/19/EU and may not be disposed of as domestic gar-
bage.
● Dispose of the device through channels provided for this purpose.
● Comply with all local and currently applicable laws and regulations..

Technical data

Power supply (GLB1..1E)


Operating voltage (SELV/PELV) / Frequency AC 24 V ~ ±20 % (19.2…28.8 V ~) / 50/60 Hz
1)
DC 24…48 V ⎓ ±20 % (19.2…57.6 V ⎓)
Power consumption running GLB14..1E, 2.2 VA / 1.3 W
GLB16..1E 2.5 VA / 1.5 W
Power consumption holding GLB14..1E, 0.5 W
GLB16..1E 0.7 W

Power supply (GLB3..1E)


Operating voltage / Frequency AC 100…240 V ~ ±10 % (90…264 V ~) / 50/60 Hz
Power consumption running GLB34..1E, 6 VA / 2 W
GLB36..1E 4 VA / 1.5 W
Power consumption holding GLB34..1E, 0.9 W
GLB36..1E 0.6 W

Function data
Nominal torque 10 Nm
Maximum torque (blocked) 16 Nm
Minimum holding torque 10 Nm
Nominal rotary angle (with position indication) 90°
Maximum rotary angle (mechanic limitation) 95° ± 2°
Runtime for 90° rotary angle 150 s
Actuator sound power level 28 dB(A)

1)
C-UL: Permitted only to DC 30 V ⎓

4 / 10
Siemens A6V10636202_en--_b
Building Technologies 2016-12-14
Inputs
Positioning signal for GLB14..1E
Operating voltage AC/DC 24 V (wires 1-6/G-Y1) clockwise
AC 24 V ~ / DC 24…48 V ⎓ (wires 1-7/G-Y2) counterclockwise
Positioning signal for GLB34..1E
Operating voltage (wires 4-6/N-Y1) clockwise
AC 100…240 V ~ (wires 4-7/N-Y2) counterclockwise
Positioning signal for GLB16..1.E
Input voltage (wires 8-2/Y-G0) DC 0/2…10 V ⎓
Current consumption 0.1 mA
Input resistance >100 kW
Max. permissible input voltage DC 35 V ⎓ limited to DC 10 V ⎓
Protected against faulty wiring max. AC 24 V ~ / DC 24…48 V ⎓
Hysteresis for non-adjustable characteristic function 60 mV
for adjustable characteristic function 0.6 % of ∆U
Adjustable characteristic function (GLB163.1E, GLB164.1E)
Adjustable with 2 potentiometers: Offset Uo DC 0…5 V ⎓
Span ∆U DC 2…30 V ⎓
Max. input voltage DC 35 V ⎓
Protected against faulty wiring max. AC 24 V ~ / DC 24…48 V ⎓

Outputs
Position indicator
Output signal (GLB16..1E) (wires 9-2/U-G0)
Output signal (GLB36..1E) (wires 9-2/U-G-)
Output voltage U DC 0...10 V ⎓
Max. output current DC ±1 mA
Protected against faulty wiring max. AC 24 V ~ / DC 24…48 V ⎓
Aux. power supply (G- / G+)
GLB36.. DC 24 V ⎓ ±20 %, max. 10 mA
Feedback potentiometer (for GLB142.1E)
Change of resistance (wires P1-P2) 0…5000 W
Load <0.25 W
Max. sliding contact current <10 mA
Permissible voltage at potentiometer (SELV/PELV) AC 24 V ~ / DC 24…48 V ⎓
Insulation resistance between potentiometer and
housing AC 500 V ~

Auxiliary switches (GLB146.1E, GLB166.1E, GLB346.1E)


Switching voltage AC 24…250 V ~ / DC 12…30 V ⎓
Contact rating 6 A resistive, 2 A inductive, min. 10 mA @ AC
4 A resistive, 2 A inductive, min. 10 mA @ DC 30 V ⎓
0.8 A res., 0.5 A inductive, min. 10 mA @ DC 60 V ⎓
Electric strength auxiliary switch against housing AC 4 kV
Switching range for auxiliary switches / setting increments 5°…90° / 5°
Factory switch setting: Switch A 5°
Switch B 85°

Connection cables
Cable length 0.9 m
2
Cross section of prewired connection cables 0.75 mm
Permissible length for signal lines 300 m

Degree of protection
Insulation class As per EN 60730
AC 24 V ~ / DC 24…48 V ⎓, feedback potentiometer III
AC 100…240 V ~, auxiliary switches II
Housing protection IP 54 as per EN 60529

5 / 10
A6V10636202_en--_b Siemens
2016-12-14 Building Technologies
Environmental conditions
Operation IEC 60721-3-3
Climatic conditions Class 3K5
Mounting location interior, weather-protected
Temperature extended -32…+55 °C
Humidity (non-condensing) <95 % r.F.
Transport IEC 60721-3-2
Climatic conditions Class 2K3
Temperature extended -32…+70 °C
Humidity (non-condensing) <95 % r.F.
Storage IEC 60721-3-1
Climatic conditions Class 1K3
Temperature extended -32…+50 °C
Humidity (non-condensing) <95 % r.F.
Mechanical conditions Class 2M2

Standards, directives and approvals


Product standard EN 60730
Part 2-14 / Particular requirements for electric
actuators
Electromagnetic compatibility For use in residential, commercial, light-industrial
(Applications) and industrial environments
2)
EU Conformity (CE) A5W00000176
2)
RCM Conformity A5W00000177
EAC Conformity Eurasian conformity
UL UL as per UL 60730 http://ul.com/database
cUL as per CSA-C22.2 No. 24-93

Environmental compatibility
2)
The product environmental declaration A5W00026066 contains data on environmentally compatible product
design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal).

Dimensions
Actuator W x H x D see „Dimensions“, p. 9
Damper shaft
round 8…16 mm
round 8…10 mm (with centering element)
Square 6…12.8 mm
Min. shaft length 20 mm
Shaft hardness <300 HV

Weight
Without packaging Max. 0.49 kg, without switches
Max. 0.63 kg, with switches

2)
The documents can be downloaded from http://siemens.com/bt/download.

6 / 10
Siemens A6V10636202_en--_b
Building Technologies 2016-12-14
Diagrams

Internal Diagrams
GLB14..1E (open-close, three-p.) GLB34..1E (open-close, three-p.)

AC 24 V ~ / DC 24…48 V ⎓ AC 100…240 V ~

GLB16..1E (modulating, Y= DC 0/2…10 V ⎓) GLB16..1E (modulating, Y= DC 0…35 V ⎓) GLB361.1E (modulating control)

AC 24 V ~ / DC 24…48 V ⎓ AC 24 V ~ / DC 24…48 V ⎓ AC 100…240 V ~

Connection diagrams
GLB1.. 1E (AC 24 V ~ / DC 24…48 V ⎓)

Open-close, single wire control Open-close, two wire control Three-position control Modulating control
Single Pole Single Throw (SPST) Single Pole Double Throw (SPDT)

7 / 10
A6V10636202_en--_b Siemens
2016-12-14 Building Technologies
GLB3.. 1E (AC 100…240 V ~)

Open-close, single wire control Open-close, two wire control Three-position control Modulating control
Single Pole Single Throw (SPST) Single Pole Double Throw (SPDT)

Cable labeling

Connection Code No Color Abbreviation Meaning


Actuators G 1 red RD System potential AC 24 V ~ / DC 24…48 V ⎓
AC 24 V ~ G0 2 black BK System neutral
DC 24…48 V ⎓ Y1 6 purple VT Positioning signal AC/DC 0 V, “clockwise” (GLB14..1E)
Y2 7 orange OG Positioning signal AC/DC 0 V, “counter-clockwise”
(GLB14..1E)
Y 8 grey GY Signal in (GLB16..1E)
U 9 pink PK Signal out (GLB16..1E)
Actuators L 3 brown BR Line AC 100…240 V ~
AC 100…240 V ~ N 4 light blue BU Neutral conductor
Y1 6 black BK Positioning signal AC 100…240 V ~, “clockwise”
(GLB34..1E)
Y2 7 white WH Pos. signal AC 100…240 V ~, “counter-clockwise”
(GLB34..1E)
G+ 1 red RD System potential DC 24 V ⎓ (aux. power supply)
(GLB361.1E)
G- 2 black BK System neutral (aux. power supply) (GLB361.1E)
Y 8 grey GY Signal in (GLB361.1E)
U 9 pink PK Signal out (GLB361.1E)
Feedback a P1 white/red WH RD Potentiometer 0…100 % (P1-P2)
potentiometer b P2 white/blue WH BU Potentiometer pick-off
c P3 white/pink WH PK Potentiometer 100…0 % (P3-P2)
Auxiliary switch Q11 S1 grey/red GY RD Switch A input
Q12 S2 grey/blue GY BU Switch A normally closed contact
Q14 S3 grey/pink GY PK Switch A normally open contact
Q21 S4 black/red BK RD Switch B input
Q22 S5 black/blue BK BU Switch B normally closed contact
Q24 S6 black/pink BK PK Switch B normally open contact

8 / 10
Siemens A6V10636202_en--_b
Building Technologies 2016-12-14
Dimensions

2.7
x

4.5

max 95°

68
50

min. 6
4634M01

min. 60

Dimensions in mm min.

Revision numbers

Type Valid from rev. no. Type Valid from rev. no.
GLB141.1E ..B GLB164.1E ..B
GLB142.1E ..B GLB166.1E ..B
GLB146.1E ..B GLB361.1E ..B
GLB161.1E ..B GLB341.1E ..B
GLB163.1E ..B GLB346.1E ..B

9 / 10
A6V10636202_en--_b Siemens
2016-12-14 Building Technologies
OpenAir™

Air damper actuators


GEB..1E

Electronic rotary actuators for 2-position, 3-position, and modulating control

● Nominal torque 20 Nm
● Operating voltage AC 24 V ~ / DC 24…48 V ⎓ or AC 100…240 V ~
● Mechanically adjustable span between 0…90°
● Pre-wired with standard 0.9 m connection cables
● Type-specific variations with adjustable offset and span for
the positioning signal
● Position indication: Mechanical and electrical
● Feedback potentiometer
● Self-adaption of the rotation angle range and adjustable auxiliary switches
for supplemental functions

A6V11449860_en--a Smart Infrastructure


2019-09-10
Use
Rotary actuators are used in ventilation and air conditioning plants to regulate and shut off
air dampers:
● For damper areas up to approximately 4 m2 (Guideline: Always comply with the damper
manufacturer's specifications).
● Suitable for use with 2-position and 3-position controllers as well as modulating
controllers (DC 0/2…10 V) to control air dampers.
● We recommend a minimum pulse length of 500 ms on rotary actuators operated with 3-
point control to ensure continuous and accurate operation.

Functions

AC 24 V ~ / 141.1E / 142.1E / 146.1E 161.1E / 163.1E / 164.1E / 166.1E


GEB.. DC 24…48 V ⎓
AC 100…240 V ~ 341.1E / 346.1E 361.1E
Control type 2-position / 3-position Modulating control (0/2…10 V)
Rotary movement, Clockwise or counterclockwise direction depends …
rotary direction
… on the type of control … on the setting on the DIL switch
… on the setting of the rotary direction clockwise / counterclockwise
switch. cw ccw
cw ccw selfadapt selfadapt
2... 2...

0 0... 0 0...
The actuator remains in the respective … on the positioning signal.
position with no power applied.
The actuator remains in the deployed
position:
…if the positioning signal is maintained at a
cw = Clockwise constant value
ccw = Counterclockwise …in the event of power loss
Position indication
Rotation angle position indication using a position indicator.
Mechanical
Position indication By connecting the feedback potentio- Position indicator: Output voltage
Electric meter to external voltage, output voltage U = DC 0/2…10 V is generated proportional
is generated proportional to rotation to rotation angle.
angle. The direction of rotation (inverted or non-
inverted) for output voltage U is based on
the DIL switch position.
Auxiliary switch The switching points for auxiliary switches A and B can be set independently in
increments of 5° from 0 to 90°.
Self-adaptation of the The actuator automatically determines the
rotation angle range mechanical end positions of the rotation
angle range.
The characteristic function (Uo, ΔU) is
-
mapped to the calculated rotation angle
range.
Power must be connected to DIL switch 2
(self-adaptation) for the function to operate.
Manual adjustment The actuator can be manually adjusted by pressing the gear train disengagement
button.
Rotation angle limitation A set screw can limit the rotation angle to between 0° and 90°.

2
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Technical design

Housing
● Robust and light cast aluminum housing. The housing guarantees long life, even under
harsh ambient conditions.

Actuator / gears
● Brushless, robust DC motors ensure reliable operation regardless of load. The damper
actuators do not require an end position switch, are overload proof, and remain in place
upon reaching the end stop.
● The gears are maintenance free and low noise.

Type summary
Type Stock number Open-loop Operating Positioning Position Feedback Self-adapting Auxili- Rotation
control voltage signal input Y indicator potentio- rotation angle ary direction
U = DC meter ranges switch switch
0…10 V ⎓ 5 kΩ

GEB141.1E S55499-D329 -
AC 24 V ~ / -
GEB142.1E S55499-D330 Yes
DC 24…48 V ⎓
2- or 3-
GEB146.1E S55499-D331 - - - 2 Yes
position
GEB341.1E S55499-D336 - -
AC 100…240 V ~
GEB346.1E S55499-D337 2

GEB161.1E S55499-D332 DC 0/2…10 V ⎓


-
GEB163.1E S55499-D333 AC 24 V ~ /
DC 0…35 V ⎓
GEB164.1E S55499-D334 Modulating DC 24…48 V ⎓ Yes - Yes Yes
2
GEB166.1E S55499-D335
DC 0/2…10 V ⎓
GEB361.1E S55499-D338 AC 100…240 V ~ -

Accessories/spare parts
See data sheet N4697

Product documentation

Topic Title Document ID


Data sheet Air damper actuators A6V11449860

Technical principles Non-spring rotary actuators GEB…1 Z4621

Mounting Instructions GEB..1E A6V11476940

Data sheet Accessory and spare parts for air damper actuators N4697

Related documents such as environmental declarations, CE declarations, etc., can be


downloaded at the following Internet address:
http://siemens.com/bt/download

3
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Notes

Safety

CAUTION

National safety regulations


Failure to comply with national safety regulations may result in personal injury and property
damage.
● Observe national provisions and comply with the appropriate safety regulations.
● Mounting, commissioning, and service by properly trained personnel only.

Engineering

Auxiliary switch and potentiometer


Cannot be integrated after the fact.

Mounting

See Mounting instructions M4621

Shaft connection
When mounting, comply with the notes on shaft diameters and damper surface areas in
Technical data (page 8) and use only quality materials typical to the sector for the damper
shaft.

Installation

WARNING

No internal line protection for supply lines to external consumers


Risk of fire and injury due to short-circuits!
● Adapt the line diameters as per local regulations to the rated value of the installed fuse.

Maintenance
The GEB..1E actuators are maintenance-free.

4
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Disposal

The device is considered an electronic device for disposal in accordance


with the European Guidelines and may not be disposed of as domestic
garbage.
● Dispose of the device through channels provided for this purpose.
● Comply with all local and currently applicable laws and regulations.

5
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Technical data

Power supply (GEB1..1E)


Operating voltage (SELV/PELV) AC 24 V ~ ± 20 % (19.2…28.8 V ~)
DC 24…48 V ⎓ ± 20 % (19.2…57.6 V ⎓) 1)
Frequency 50/60 Hz
Power consumption: During GEB14..1E 2.3 VA / 1,1 W
operation GEB16..1E 2.5 VA / 1.2 W
Holding GEB14..1E 0.5 W
GEB16..1E 0.65 W

Power supply (GEB3..1E)


Operating voltage (SELV/PELV) AC 100…240 V ~ ± 10 % (90…264 V ~)
Frequency 50/60 Hz
Power consumption: During GEB34..1E 4 VA / 1.6 W
operation GEB36..1E 3.4 VA / 1.3 W
Holding GEB34..1E 0.9 W
GEB36..1E 0.6 W

Function data
Nominal torque 20 Nm
Maximum torque (when blocked) 35 Nm 2)
Minimum holding torque 20 Nm
Nominal rotation angle (with position indication) 90°
Maximum rotation angle (mechanically limited) 95° ± 2°
Runtime at nominal rotation angle 90° 150 s
Actuator sound power level (at a positioning time of 150 s) <35 dB(A)

Inputs
Positioning signal for GEB14..1E
Operating voltage (wires 1-6/G-Y1) Clockwise
AC 24 V ~ / DC 24…48 V ⎓ (wires 1-7/G-Y2) Counterclockwise
Positioning signal for GEB34..1E
Operating voltage (wires 1-6/G-Y1) Clockwise
AC 100…240 V ~ (wires 1-7/G-Y2) Counterclockwise
Positioning signal for GEB16..1E
Input voltage (wires 8-2/Y-G0) DC 0/2…10 V ⎓
Power consumption 0.1 mA
Input resistance >100 kΩ
Max. permissible input voltage DC 35 V ⎓ limited internally to DC 10 V ⎓
Protected against faulty wiring Max. AC 24 V ~/ DC 24…48 V ⎓
Hysteresis for non-adjustable characteristic function 60 mV
for adjustable characteristic function 0.6 % of ΔU
Adjustable characteristic (GEB163.1E, GEB164.1E)
Adjustable with 2 potentiometers: Offset Uo DC 0…5 V ⎓
Span ΔU DC 2…30 V ⎓
Max. input voltage DC 35 V ⎓
Protected against faulty wiring Max. AC 24 V ~ / DC 24…48 V ⎓

1) cUL: Only to DC 30 V ⎓ permissible


2) See notes on page 4 and page 8

6
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Outputs
Position indicator
Output signal (GEB16..1E) (wires 9-2/U-G0)
Output signal (GEB36..1E) (wires 9-2/U-G-)
Output voltage U DC 0…10 V ⎓
Max. output current DC ± 1 mA
Protected against faulty wiring Max. AC 24 V ~/ DC 24…48 V ⎓
Aux. power supply (G-/G+)
GEB36.. DC 24 V ⎓ ± 20 %, max. 10 mA
Feedback potentiometer (for GEB142.1E)
Change in resistance (wires P1-P2) 0…5000 Ω
Load <0.25 W
Max. contact current <0.1 mA
Permissible voltage at potentiometer (SELV/PELV) AC 24 V ~ / DC 24…48 V ⎓
Insulation resistance between potentiometer and AC 500 V ~
housing

Auxiliary switches (GEB146.1E, GEB166.1E, GEB346.1E)


Switching voltage AC 24…250 V ~ / DC 12…30 V ⎓
Contact loading 6 A resistive, 2 A inductive, min. 10 mA @ AC
4 A resistive, 2 A inductive, min. 10 mA @ DC 30 V ⎓
0.8 A resistive, 0.5 A inductive, min. 10 mA @ DC 60 V⎓
Electric strength auxiliary switch against housing AC 4 kV
Switching range for auxiliary switches / setting 5°…90° / 5°
increments
Factory switch setting: Switch A 5°
Switch B 85°

Connection cables
Cable length 0.9 m
Cross-section 0.75 mm2
Permissible length for signal wires 300 m

Safety class and degree of protection


Protection class EN 60730
AC 24 V ~ / DC 24…48 V ⎓, feedback III
potentiometer II
AC 100…240 V ~, auxiliary switches
Degree of protection of housing IP54 as per EN 60529 (see "Mounting", page 4, and
Mounting instructions A6V11476940)

Environmental conditions
Operation IEC 60721-3-3
Climatic conditions Class 3K5
Mounting location interior, weather-protected
Temperature -32…55 °C
Humidity, non-condensing <95 % r.h.
Transportation IEC 60721-3-2
Climatic conditions Class 2K3
Temperature -32…70 °C
Humidity, non-condensing <95 % r.h.
Storage IEC 60721-3-1
Climatic conditions Class 1K3
Temperature -32…50 °C
Humidity, non-condensing <95 % r.h.
Mechanical conditions Class 2M2

7
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Standards, directives and approvals
Product standards EN60730
Part 2-14: Particular requirements for electric
actuators
Electromagnetic compatibility (field of use) For residential, commercial, and industrial
environments
EU conformity (CE) A5W00051707 3)
RCM conformity A5W00051708 3)
EAC compliance Eurasian conformity
UL UL as per 60730 http://ul.com/databse
Federal Communications Commission cUL as per CSA-C22.2 No. 24-93

Environmental compatibility
The product environmental declaration A5W00055607 3) contains data on environmentally compatible product
design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal).

Dimensions
Actuator (W x H x D) See "Dimensions" (page 11)
Damper shaft
Round 8…20.5 mm
Square (diagonal) 8…14.5 mm
Min. length 20 mm
Max. shaft hardness <300 HV

Weight
Excl. packaging Max. 1.1 kg, without auxiliary switches
Max. 1.3 kg, with auxiliary switches

3) Documents can be downloaded at http://siemens.com/bt/download.

NOTICE

Shaft connection – Important notes for the manufacturer / installer


Use of unsuitable damper shafts may damage the damper or damper shaft.
● Use only damper shafts with diameters suitable for the damper surface.
● Use only quality materials typical for the sector for damper shafts/rods.

8
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Connection diagrams

Internal Diagrams

GEB14..1E GEB34..1E
(open-close, 3-position control) (open-close, 3-position control)

AC 24 V ~ / DC 24…48 V ⎓ AC 100…240 V ~

III AC 24...250 V ~ / 6 (2) A


SELV/PELV DC 12...30 V / 2 A AC 24...250 V ~ / 6 (2) A
AC 24 V ~
DC 24...48 V 0...5000 AC 100...240 V ~ DC 12...30 V / 2 A

1 6 7 S1 S4

(Q21)
(a)
(b)

(c)

(Q21)

(Q11)
(Q11)

100%
M 5° 85°
M 5° 85°
0%
(Q12)

(Q14)

(Q22)

(Q24)

(Q12)

(Q14)

(Q22)

(Q24)
6 7 4 S2 S3 S5 S6
N

GEB16..1E GEB16..1E GEB361.1E


(modulating, Y = DC 0/2…10 V ⎓) (modulating, Y = DC 0…35 V ⎓) (modulating, Y = DC 0/2…10 V ⎓)

AC 24 V ~ / DC 24…48 V ⎓ AC 24 V ~ / DC 24…48 V ⎓ AC 100…240 V ~

SELV/PELV
III AC 24 V ~ AC 24...250 V ~ / 6 (2) A III AC 24 V ~ AC 24...250 V ~ / 6 (2) A DC 24 V DC 0/2...10 V
DC 24...48 V DC 0/2...10 V DC 12...30 V / 2 A DC 24...48 V DC 0...35 V DC 12...30 V / 2 A AC 100...240 V ~
3 1 8
1 8 1 8
(Q21)

(Q21)
(Q11)

(Q11)

100%
100% 100%
M
M M
0%
0% 0%
(Q12)

(Q14)

(Q22)

(Q24)
(Q12)

(Q14)

(Q22)

(Q24)

N G-
G0 U G0 U
4 2 9
2 9 2 9 N
DC 0/2...10 V
DC 0/2...10 V DC 0/2...10 V

Connection diagrams
Control on GEB1..1E (AC 24 V ~ / DC 24…48 V ⎓)

Open-close, single wire control Open-close, double wire control 3-position control Modulating control
Single pole single throw (SPST) Single pole double throw (SPDT)
AC 24 V ~ AC 24 V ~ AC 24 V ~ AC 24 V ~
DC 24...48 V DC 24...48 V DC 24...48 V DC 24...48 V

G G G

Y1 Y2 Y1 Y2 Y1 Y2 G Y U

G0

AC 24 V ~ AC 24 V ~ AC 24 V ~
DC 24...48 V DC 24...48 V DC 24...48 V

Y1 Y2 Y1 Y2 Y1 Y2

G G G

9
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Control on GEB3..1E (AC 100…240 V ~)

Open-close, single wire control Open-close, double wire control 3-position control Modulating control
Single pole single throw (SPST) Single pole double throw (SPDT)
AC 100...240 V ~ AC 100...240 V ~ AC 100...240 V ~
AC 100...240 V ~

Y1 Y2 Y1 Y2 Y1 Y2 L G+ Y U

N N N N G-

N N N N

Cable designations

Connecting thread Code No. Color Abbreviation Meaning


Actuators G 1 red RD System potential AC 24 V ~ / DC 24…48 V ⎓
AC 24 V ~ / DC 24…48 V ⎓ G0 2 black BK System zero
Y1 6 violet VT Positioning signal AC/DC 0 V, clockwise (GEB14..1E)
Y2 7 orange OG Positioning signal AC/DC 0 V, counterclockwise (GEB14..1E)
Y 8 gray GY Signal input (GEB16..1E)
U 9 pink PC Signal output (GEB16..1E)
Actuators L 3 brown BR Phase, AC 100…240 V ~
AC 100…240 V ~ N 4 light blue BU Neutral conductor
Y1 6 black BK Positioning signal AC 100…240 V ~, clockwise (GEB34..1E)
Y2 7 white WH Positioning signal AC 100…240 V ~, counterclockwise (GEB34..1E)
G+ 1 red RD System potential DC 24 V (auxiliary power) (GEB361.1E)
G- 2 black BK System neutral (auxiliary power) (GEB361.1E)
Y 8 gray GY Signal input (GEB361.1E)
U 9 pink PK Signal output (GEB361.1E)
Feedback potentiometer a P1 white/red WH RD Potentiometer 0…100 % (P1-P2)
b P2 white/blue WH BU Potentiometer pick-off
c P3 white/pink WH PK Potentiometer 100…0 % (P3-P2)
Auxiliary switch Q11 S1 gray/red GY RD Switch A input
Q12 S2 gray/blue GY BU Switch A NC contact
Q14 S3 gray/pink GY PK Switch A NO contact
Q21 S4 black/red BK RD Switch B input
Q22 S5 black/blue BK BU Switch B Normally closed contact
Q24 S6 black/pink BK PK Switch B NO contact

10
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
Dimensions
min. 100

10.5
min. 100
min. 7

min. 60
min. 150

min. 100

Dimensions in mm

11
Siemens A6V11449860_en--a
Smart Infrastructure 2019-09-10
7. Test Reports
Appendix to the License Agreement To Use
The AMCA Certified Ratings Program Seal
Appendix No: 8
In accordance with the License Agreement issued on November 21, 2012 by Air Movement and Control
Association International, Inc., SAFID, is hereby authorized to use the AMCA Certified Ratings Seal on the specific
air movement and control devices listed below. Such use shall in all respects be governed by and subject to the
provisions of said License Agreement.

Dampers
Product Line Catalog ID
SPK30-400 Class 1A & Class 1 Low Leakage SPK30-400 January, 2014
Volume Control Damper

Minimum Minimum Model


Width Height Name
3.94 x 3.94 SPK30-400

Maximum Maximum Model


Width Height Name
35.43 x 35.43 SPK30-400

*License to Bear the AMCA Seal for Air Leakage, Air Performance

Please verify current certification status in the AMCA International Directory of Licensed Products located at
www.amca.org.
Granted This 18th day of March, 2014.

Lisa R. Ullrich
Certified Ratings Program Manager
AIR MOVEMENT AND CONTROL ASSOCIATION
INTERNATIONAL, INC.

Page 1 of 1
8. Material Safety Data Sheets
SafidDampers
Class 1A & Class 1
Low Leakage Volume Control Damper SPK 30 Series
Installation Details
Damper to Slide on Flange connection Damper to Angle Flange connection

Flange Drilling Details


Flange Drilling Details
Flange drilling details
W H No. of Holes No. of Holes
in mm in mm W Dim. H Dim.
150 150 2 2
200 150 2 2
300 300 3 3
400 300 4 3
500 300 4 3
450 450 4 4
500 450 4 4
600 450 5 4
700 450 6 4
800 450 7 4
900 450 8 4
600 600 5 5
700 600 6 5
800 600 7 5
900 600 8 5
750 750 6 5
800 750 7 5
900 750 8 5
900 900 8 8

Catalog ID: SPK 30-400 January 23, 2014

Right to alterations reserved.

8
MATERIAL SAFETY DATA SHEET
9. Previous Approvals
External Transmittal
INFRASTRUCTURE & CIVIL PROJECTS-DUKHAN
Project No : 3932C Transmittal No :
Contract No : GC19104100 PID/GC19104100/EXT/TN/0762
Contract Title : CONSTRUCTION OF OIL AND GAS DATA CENTRE BUILDING IN QPSFA DUKHAN

Forwarded to Review Codes


Company : Medgulf Construction Co. 10 Approved (Re-submission Not Required)

F.a.o.: Asok Mani C

Item
No. QP Document No. Rev. Your ref. Description Code Due date
1 3932-9-MS-0093 1 GC19104100/PID/TN/ MATERIAL SUBMITTAL FOR MOTORIZED 10
0829 VOLUME CONTROL DAMPER

Remarks:
Condition:
Document Controller Nominated Deputy QP Representative Date
Tel: 40136625 Tel: 40135735
Suresh Wadye, PSD17 Kamal Moghaddam, PID11 Khalid Mohd Kaldari, PID 27-08-2020
If applicable, please resubmit documents before due date
This is QP system generated transmittal and therefore requires No Signature

Receiver's Signature Over Printed Name Designation Date

Page 1 of 1 27-08-2020
10. List of Previous Projects
MEP CONTRACTOR PROJECT NAME
AL MALKI TRADING AND CONTRACTING WESTERN MID FUEL FARM - HIA

AL MALKI TRADING AND CONTRACTING DOHA SOUTH PUMPING STATION


ARROWHEAD MESAIMEER PUMPING STATION
ELECTROWATT AL WAKRA BUS DEPOT
ELECTROWATT IBN AL SHEIKH TOWER
AL MULLA DOLPHIN TOWER
MAPCO AL UDEID AIRBASE
PSC FALCON 5
UNITED ELECTROMECHANICAL HANGAR FOR QATAR EMIRI
MECHATRONICS QATAR EMIRI SIGNAL CORPS - NEW CAMP
BK GULF DREAM HOTEL
BK GULF QUANTUM DATA CENTER
NYSA TRADING and CONTRACTING OVG DATA CENTER DUKHAN (QP)
REDCO INTERNATIONAL AL RAYYAN, INDUSTRIAL AREA, LUSAIL BUS DEPOTS
ELEGANCIA MEP LOSAIL INTERNATIONAL CIRCUIT
ELEGANCIA MEP THE VIEW HOSPITAL
ELEGANCIA MEP LUSAIL PALACE
ELEGANCIA MEP LABOUR ACCOMMODATION WAKRA
ELEGANCIA MEP FAMILY ACCOMMODATION
QFZ PROVISION of DESIGN SERVICES for NEW LIGHT
ERTIBAT
INDUSTRIAL UNITS

AL JABER ENGINEERING and TEKFEN CONSTRUCTION AL THUMAMA STADIUM


HBK CONTRACTING LUSAIL STADIUM
HBK CONTRACTING SAMRYA VILLAGE
MARMI ENGINEERING 11 PRIMARY HEALTH CARE CENTERS
MEP ENTERPRISES HMC - RUMAILAH HOSPITAL
MEP ENTERPRISES HMC - DUKHAN HOSPITAL
MEP ENTERPRISES SURGICAL ART CENTER, LOSAIL
AL JABER ELECTRO MECHANICAL QETAIFAN ISLAND NORTH
AL JABER ELECTRO MECHANICAL QATAR PPP SCHOOLS
AL JABER ENGINEERING ISF DUHAIL
CONSTRUCTION DEVELOPMENT CO RAS ABROUQ RESORT
CONSTRUCTION DEVELOPMENT CO MARSA ARABIA
VALENCE TRADING and CONTRACTING DUKHAN BANK HQ
RAMCO MEP ALMANA EDITION HOTEL
AL SEAL CONTRACTING SHIELD 5
Sl # Customer Project
1 Morganti / AICI JV Millennium Village Facilities
2 Voltas Limited Villagio
3 Qatari Modern Maintenance Co Al Jazi Tower
4 Qatar Electro Mechanical Group Sheraton Hotel
5 Mercury Qatar Regency Tower
6 Arcon HMC Education Centre
7 Diplomat Group Andy Villa
8 Arabian Air-conditioning Kharthiath North Switching Station
9 Al Hani Gulf Contracting Co Al Wabra Breeding Centre
10 Qatar Technical Support Dolphin Tower
11 Arcon Qatar Foundation
12 Qatar Electro Mechanical Group Al Dana Tower
13 Texas Services Khalitha Alimasand Tower
14 Electro Mechanical Enterprises Qatar Al Jazeera Tower
15 Al Andalous Contracting Haya Residential Building
16 Texas Services Al Khore Villa
17 Texas Services Al Fardan Villa
18 Diplomat Group Batel bakery
19 Arabian Air-conditioning HMC Extension at Rumaila & Airport
20 Qatar Electro Mechanical Group Al Mana Tower
21 Shelter Qatar West Bay Villa
22 Midmac Contraco JV Qatar Foundation Education City
23 United Contracting for EMA WLL Qatar Foundation Education City
24 Texas Services Fahahil Main Pump station
25 Diplomat Group School
26 Al Annab Trading & Contracting Co Al Rabban Tower
27 Nile Aster Qatar La Cigale Hotel
28 Qatar Arabian Construction Co La Cigale Hotel
29 Arabian Air-conditioning Kahraama DCC Project
30 Qatar Techniques Co Sheikh Thamim Villa
31 Electro Mechanical Engineering Co 6 Villa @ West Bay
32 ERE Contracting Co City Centre Expansion Phase ǿǿ
33 HBK Engineering Services HMC Medical Tower
34 Texas Services Techno Extension
35 ERE Contracting Co QC 44 Residential Tower
36 TSSC West Bay Cooling Plant
37 Texas Services Multi Purpose hall at Duhail
38 Mercury Qatar Science & Technology Park
39 Electro Mechanical Engineering Co Qatar Islamic Bank
40 Arabian Air-conditioning Qatar Trans Sys. Exp-Phase V
41 Gulf Industries Asian Games Camp
42 Qatar Gulf Trading & Contracting Co Club House
43 Qatar Techniques Co Shk. Hamad Bin Jasim Al Thani- Office Tower
QATAR Projects List-
Sl # Customer Project
44 TSSC Qatar Gas Development
45 Qatar Techniques Co Wabra School
46 Arab United Construction Co Al Jinnan Recreation Centre
47 Shelter Qatar Blue Saloon
48 Arabian Air-conditioning Sheraton Hotel
49 HBK Engineering Services Hamad Medical Corporation
50 Electro Mechanical Engineering Co 17 Villa @ West Bay
51 Qatar Techniques Co School @ North Duhail
52 TSSC Qatar Gas XII LNG Off-shore Ras Laffan
53 TSSC Qatar Gas XII LNG On-shore Ras Laffan
54 Ultimate Trading Co Al Maja Complex
55 HBK Engineering Services Staff Accommodation @ Abu Samra
56 CCIC & Teyseer Contraco Qatar Gas LNG Off-shore Project
57 TEST Electrical & Mechanical Co Ali Bin Ali Show Room
58 CCIC & Teyseer Contraco Qatar Gas III & IV On Shore
59 Drake & Scull Al Hitmi Office Building
60 Drake & Scull Al Hitmi Residence Tower
61 HBK Engineering Services Landmark Shopping Mall
62 BEMCO Contracting New Doha International Airport
63 Construction Development Co Al Fardan Residence
64 Construction Development Co Porto Arabia
65 Construction Development Co Lebanes School
66 HBK Engineering Services KAHRAMAA Substation
67 How United Company KAHRAMAA Substation
QATAR PROJECT LIST

68 Lotus School (4 Schools ) ASHGHAL Al Jaber E/M


69 2 Health care centers at karana ASHGHAL Al Jaber E/M
70 2 Health Care center ASHGHAL HBK Engineering
71 Karana Schools(3 Schools) ASHGHAL Al Jaber E/M
72 QIB HOTEL SHANNON ENGINEERING
73 MOFA TOWER MOI ARGON GLABAL
74 MOI HEAD QUARTER MOI Transgulf E/M
75 Al UDIED AIR BASE QATAR ARM FORCES AYTB
76 Al UDIED AIR BASE QATAR ARM FORCES AL ATTAR Contracting
77 LUSAIL SPORTS CLUB QATAR OLYMPICS ETA STAR
78 AL SAAD STADIUM QATAR OLYMPICS AKTOR
79 CP26 NDIA NDIA AKTOR
80 CP11 NDIA NDIA AKTOR
81 CP94 NDIA NDIA AKTOR
82 CP18 NDIA NDIA BEMCO
83 AIR TRAFIC CONTROL NDIA NDIA CCIC
84 ST REGIS HOTEL ST REGIS HOTEL Construction Development
Company
85 Al Fardan Residence Tower Al Fardan Construction Development
Company
86 QATAR SCIENCE TECHNOLOGY PARK MERCURY QATAR
87 3 Schools Project ASHGHAL TAKYEEF
88 3 Schools Project ASHGHAL QTEC
89 NEW WEDDING HALL ASHGHAL QTEC
90 CITY CENTER EXPANSION 2 CITY CENTER ERE
91 PEARL VILLAS PEARL SHELTER QATAR
92 BANANA ISLAND AKTOR
93 ISLAND PALACE PRIVATE OFFICE RADIANT ENGINERING
94 KATARA QEMC
95 DUKHAN QP DOPET
96 NGL SUPPORT CAMPUS QP DIPLOMAT ENGINEERING
97 NORTH EAST CAR PARK QATAR FOUNDATION TERNA
98 QATAR FOUNDATION ANEL
99 HERITAGE QUARTER AL FUTTAIM ENGINEERING
100 PEARL CINEMA AL FUTTAIM ENGINEERING
101 5 Schools ASHGHAL BHAMOJHMOOR E/M
102 NEW College Of Engineering Qatar University ETA STAR
11. Country of Origin
Certificate of Origin
SAFID MAKE PRODUCTS
CONTRACTOR: M/s. Q-Tec Engineering W.L.L.
PROJECT: Design & Construction of New Light Industrial Unit-City Neon at Ras Bu Fontas Free Zone

We certify that the country of origin of SAFID MAKE DAMPERS is STATE OF QATAR.

The fabrication/Assembly of the same for the above- m e n t i o n e d project is done by SAFID
LIMITED (QATAR FACTORY).

For Gulf Facilities Trading & Contracting Co. W.L.L,


12. Draft Warranty
Ref No.: XXXXX.01/FA/WC/22
DRAFT WARRANTY CERTIFICATE

PROJECT : Design & Construction of New Light Industrial Unit-City Neon at Ras Bu
Fontas Free Zone

MEP CONTRACTOR : M/s. Q-Tec Engineeering W.L.L.


PRODUCT : SAFID QATAR MAKE DAMPERS

Our Company warrants SAFID QATAR MAKE DAMPERS or parts thereof to be free from
workmanship and material within 24 months from the date of delivery or 12 months from the date
commissioning, by the use as a result normal use and service.

Our company will replace the part or parts so determined by it to be defective with new parts, at
Company's cost and expense. This warranty is exclusive, and there are no other warranties or
representations, expressed or implied.

For the period of 12 months from the date of commissioning, our company warrants to the original
purchaser, that a new Unit is free from defect in material and workmanship and agrees to repair or
replace any defective parts. However, parts that don’t have a predictable life are not covered in
this warranty.

This warranty does not apply to units which, after our inspection, are determined to have been
damaged due to neglect, abuse, overloading, accident or improper usage. All shipping and handling
charges will be paid by the customer. Under no circumstances shall consequential damages be
recoverable

For, GULF FACILITIES TRADING & CO. W.L.L.

DATED: DD/MMM/YYYY
13. Material/Product Sample Photo

You might also like