Schischek Product Catalogue en PUB113 001 00
Schischek Product Catalogue en PUB113 001 00
H VA C
Product Catalogue
www.schischek.com
Price list Catalogue
Product 2021
Greenland
Sweden
Iceland
Finland R u s s i a
Norway
Estonia
Neth. Belarus
Ireland Poland
Germany
Bel.
Lux. Czech Rep. Ukraine
Licht. Austria
Slovakia Kazakhstan
Mold.
France Switz. Slovenia
Hungary Mongolia
Croatia Romania
Italy Bos. &
Herz. Serb.
Mont. Bulgaria
Albania Mace.
Georgia Uzbekistan Kyrgyzstan
Portugal Spain Armenia Azerb. N. Korea
United States Greece
Turkey Turkmenistan Tajikistan
Japan
Gibraltar S. Korea
Malta Cyprus Syria C h i n a
Morocco Tunisia
Lebanon
Iraq Iran Afghanistan
Israel
Jordan
Algeria Kuwait Nepal
Libya Pakistan Bhutan
Western Sahara Egypt Bahrain
Qatar
Mexico Bahamas (Occupied by Morocco)
Bangladesh
Saudi Arabia U.A.E.
Cuba India Hong Taiwan
Dom. Rep.
Mauritania Laos Kong
Puerto Rico
Oman
Jamaica Haiti Mali Niger
Belize Chad
Honduras Cape Verde Senegal Eritrea Yemen Thailand Philippines
Guatemala
Nicaragua Gambia Sudan Cambodia
El Salvador Guinea-Bissau Burkina Faso Dijbouti Vietnam
Trinidad & Tobago Benin
Costa Rica
Panama Guinea Nigeria
Venezuela Guyana Sierra Leone
Cote Togo Ethiopia
d'Ivoire
Ghana Central African Republic Palau
French Guiana Sri Lanka Brunei
Liberia Cameroon
Colombia Suriname
Somalia Malaysia
Equatorial Guinea Uganda
Kenya Singapore
Congo
Ecuador Gabon Rwanda
Dem. Rep.
of Congo Burundi Papua
I n d o n e s i a New Guinea
Peru Tanzania Solomon Islands
B r a z i l East Timor
Angola Somoa
Malawi
Zambia Vanuatu
Fiji
Bolivia
Zimbabwe Mauritius
Namibia Mozambique
Botswana Tonga
Paraguay
Chile A u s t r a l i a
Madagascar
Swaziland
Rotork GmbH
Lesotho
South Africa
Argentina Uruguay
Muehlsteig 45
New Zealand
2 www.schischek.com
Price list Catalogue
Product 2021
Schischek supplies control companies and contractors fire and smoke dampers, paintspray areas, exhaust
in the Building Automation market. We have developed systems in chemical laboratories, battery rooms, sew-
equipment which is compatible with nearly all control age treatment plants, pumping stations etc.
systems. By combining Schischek products with con-
ventional switching and control equipment, reliable
high quality systems are implemented that conform to
Ex protection standards. Some examples of use are
Harsh environmental conditions and robust quality Since, thousands of Schischek actuators in special alu-
cause stringent design / construction requirements on minium and stainless steel housings or with offshore/
components and materials. A fast closing electric ac- marine coating have been delivered and installed,
tuator for fire / smoke dampers of less than 3 seconds moreover, the product range has been continuously
is a requirement on oil and gas platforms as well as on enlarged and refined.
FPSO‘s. After an intense development process includ-
ing trials, a completely new concept in actuator engi-
neering was produced.
Whether you need air flow control in a pharmaceutical completion. At the same time, safety and reliability in-
plant or temperature regulation of paint tanks in the car crease in planning, installation, approval and operation.
industry, Schischek offers cost-effective solutions spe- Since all equipment is maintenance-free, cost savings
cifically designed for control integration. Ex protection are realised.
is required for applications from paint spray shops to
drying stations. System compatibility with all aspects
of control facilitates integrated planning from design to
In co-operation with valve and damper manufactur- We can provide solutions to problems as far as Ex
ers, industrial control companies and contractors, ventilation and precise temperature control in industrial
Schischek products are in use worldwide. Our products plants are concerned.
are characterised by the “highest protection class, com-
pact size and easy handling”.
www.schischek.com 3
Price list Catalogue
Product 2021
In the diagram below, a typical air-handling system shows which equipment is allowed
in the Ex area and which should only be placed in the safe area. The diagram does
not claim to be complete.
If in doubt, please do not hesitate to consult us at Schischek. We will advise you in any
case. A brief discussion in the early stages of planning can avoid substantial costs in
remedial work later and gives you the peace of mind that you have a safely installed
operating system.
M ΔP F ΔP
Ex area
1 6 3 7 6 2
M M
%rH
rF
Safe area
Hz
°C
1 2 3 4
Quarter turn actuators for dampers and valves Failsafe linear valve actuators Linear valve actuators Temperature and humidity sensors
4 www.schischek.com
Price list Catalogue
Product 2021
%rH
rF °C ΔP °C ΔP M M
4 7 5 4 8 1 1
VAV
PLC-System
5 6 7 8
Pressure/ differential pressure sensors Filter monitoring, fan belt protection Thermostats, humidistats, Frost protection Controller
www.schischek.com 5
Price list Catalogue
Product 2021
Content overview
Installation areas
Gas Dust Gas Dust Gas Dust
Product series Page 0 20 1 21 2 22 SA*
Quarter turn actuators 90°
ExMax size S/M 5… 150 Nm with/without spring return 10-11
RedMax size S/M 5… 150 Nm with/without spring return 12-13
InMax size S/M 5… 150 Nm with/without spring return 14-15
Linear valve actuators with spring return with 7,5 /10 /15 /20 /30 /42 mm stroke (fixed)
LIN-..+ ExMax.. size S/M 500… 3.000 N with spring return 18-19
LIN-..+ RedMax.. size S/M 500… 3.000 N with spring return 18-19
LIN-..+ InMax.. size S/M 500… 3.000 N with spring return 18-19
Valve actuators with 5...60 mm stroke
ExRun size S 500… 10.000 N without spring return 20-21
RedRun size S 500… 10.000 N without spring return 20-21
InRun size S 500… 10.000 N without spring return 20-21
Special options for actuators
Overview special options for actuators 22-23
ExPolar / ExArctic heating system for actuators use in Ex areas down to −50 / −60 °C 25
InPolar / InArctic heating system for actuators use in safe area down to −50 / −60 °C 25
Controller for volume flow (VAV) and pressure regulation
ExReg-V volume flow and pressure controller 0… 1.000 Pa 28-29
InReg-V volume flow and pressure controller 0… 1.000 Pa 28-29
Analog sensors for measuring of volume flow, temperature, humidity, pressure/differential pressure
ExCos-P differential pressure, VAV sensors ± 100… 7.500 Pa 33
RedCos-P differential pressure, VAV sensors ± 100… 7.500 Pa 33
InCos-P differential pressure, VAV sensors ± 100… 7.500 Pa 33
ExCos-D temperature and humidity transmitter for ExPro-C… sensors 34
RedCos-D temperature and humidity transmitter for ExPro-C… sensors 34
InCos-D temperature and humidity transmitter for InPro-C… sensors 34
ExPro-C… temperature and humidity sensors for operation in HVAC systems 35
InPro-C… temperature and humidity sensors for operation in HVAC systems 35
ExLine/ExSens transmitter EXL-IM-9182-… and analog, passive temperature-/humidity-/pressure sensors 36-37 () () ()
Switching sensors (thermostats, hygrostats, pressostats, fan belt protection, frost protection)
ExBin-P pressure / differential pressure 0… 5.000 Pa 41
RedBin-P pressure / differential pressure 0… 5.000 Pa 41
InBin-P pressure / differential pressure 0… 5.000 Pa 41
ExBin-FR frost protection thermostat −10… +15 °C 42
RedBin-FR frost protection thermostat −10… +15 °C 42
InBin-FR frost protection thermostat −10… +15 °C 42
ExBin-A modules for adaptation of 1-2 passive, potential free, switching ExSens sensors 43
RedBin-A modules for adaptation of 1-2 passive, potential free, switching ExSens sensors 43
InBin-A modules for adaptation of 1-2 passive, potential free, switching sensors 43
ExBin-D temperature and humidity thermostat for ExPro-B… sensors 44
RedBin-D temperature and humidity thermostat for ExPro-B… sensors 44
InBin-D temperature and humidity thermostat for InPro-B… sensors 44
ExPro-B… thermostat / hygrostat sensors for operation in HVAC systems 45
InPro-B… thermostat / hygrostat sensors for operation in HVAC systems 45
ExLine/ExSens switching module EXL-IR-9170-… and binary, passive temperature-/humidity-/pressure sensors 46-47 () () ()
Special options for sensors
Overview special options for sensors 48
ExPolar / ExArctic heating system for sensors’ use in Ex areas down to −40 / −60 °C 49
InPolar / InArctic heating system for sensors’ use in safe area down to −40 / −60 °C 49
Door holder magnets
ExMag door holder magnets with 650, 1.300, 2.000 N force 50
Components
ExComp different Ex-components, e.g. switches, push buttons, … 50
6 www.schischek.com
Price list Catalogue
Product 2021
Conditions
Services Specification of Services
Warranty 12+12 warranty extension available, please contact our sales team
Warranty 12+24 warranty extension available, please contact our sales team
Service Commissioning available, please contact our sales team
Service On-site service on request
Training on request
www.schischek.com 7
Price list Catalogue
Product 2021
EASY INSTALLATION
COMPACT DIMENSIONS
8 www.schischek.com
Price list Catalogue
Product 2021
normal wiring
Actuators for smoke- and fire-dampers ExMax-.., RedMax-.., InMax-.. ¼ turn actuators
normal wiring
normal wiring
normal wiring
Actuators for butterfly valves and other ¼ turn valves ExMax-.., RedMax-.., InMax-.. ¼ turn actuators
normal wiring
www.schischek.com 9
Price list Catalogue
Product 2021
ExMax 90° Ex quarter turn actuators size “S” for zone 1, 2, 21, 22
Explosion proof Features of ExMax-.. size S
ExMax-.. Size S Description Basics
Zone 1, 2, 21, 22 ExMax are, in acc. with type, for automation of air • 24…240 VAC/DC self adaptable power supply
Gas + Dust dampers, fire and smoke dampers, volume control, as • Up to 5 different running times adjustable on site
certified according to well as for ball valves, throttle valves and other quarter • 95° angle of rotation (5° pretension)
ATEX, IECEx, EAC, turn armatures. • 100% overload protected
INMETRO, KOSHA • Aluminium housing IP66, cable ~ 1 m
UL*, CSA*, Delivery: • −40°C (−20°C for type …F1) up to +40°C/ +50°C
*…-A version only 1 actuator, ~ 1 m cable, allen key for manual override, • Emergency manual override
4 screws. • Squared shaft connection 12 × 12 mm
• Dimensions (H × W × D) 210 × 95 × 80 mm
Ex-d quarter turn actuators without spring return, 24 to 240 VAC/DC, for zone 1, 2, 21, 22
Type Torque Running time 90° Spring return Control mode Feedback Features Size
ExMax- 5.10 5 Nm / 10 Nm 3/15/30/60/120 sec. - On-off, 3-pos - - S
ExMax-15.30 15 Nm / 30 Nm 3/15/30/60/120 sec. - On-off, 3-pos - - S
ExMax- 5.10-S 5 Nm / 10 Nm 3/15/30/60/120 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - S
ExMax-15.30-S 15 Nm / 30 Nm 3/15/30/60/120 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - S
ExMax- 5.10-Y 5 Nm / 10 Nm 7,5/15/30/60/120 sec. - 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - S
ExMax-15.30-Y 15 Nm / 30 Nm 7,5/15/30/60/120 sec. - 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - S
Ex-d quarter turn actuators with spring return, 24 to 240 VAC/DC, for zone 1, 2, 21, 22
Type Torque Running time 90° Spring return Control mode Feedback Features Size
ExMax-5.10- F 5 Nm / 10 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos - - S
ExMax- 15- F 15 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos - - S
ExMax-5.10-SF 5 Nm / 10 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - S
ExMax- 15-SF 15 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - S
ExMax-5.10-YF 5 Nm / 10 Nm 7,5/15/30/60/120 sec. ~ 3 sec. / 10 sec. 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - S
ExMax- 15-YF 15 Nm 7,5/15/30/60/120 sec. ~ 3 sec. / 10 sec. 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - S
ExMax-5.10-BF 5 Nm / 10 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos 2 × aux. switches (5° /85°) ExPro-TT-.. connector S
ExMax- 15-BF 15 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos 2 × aux. switches (5° /85°) ExPro-TT-.. connector S
Ex-d quarter turn actuators with fast spring return for Offshore application, 24 to 240 VAC/DC, for zone 1, 2, 21, 22
Type Torque Running time 90° Spring return* Control mode Feedback Features Size
ExMax- 8- F1 6 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off - - S
ExMax-15- F1 12 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off - - S
ExMax- 8-SF1 6 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off 2 × aux. switches (5° /85°) - S
ExMax-15-SF1 12 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off 2 × aux. switches (5° /85°) - S
ExMax- 8-BF1 6 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off 2 × aux. switches (5° /85°) ExPro-TT-.. connector S
ExMax-15-BF1 12 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off 2 × aux. switches (5° /85°) ExPro-TT-.. connector S
*At low temperatures the spring return time might vary. For further assistance please contact our sales team.
Accessories
Type Description/Technical data
ExSwitch External, adaptable, on site adjustable Ex-d auxiliary switch with 2 potential free contacts, adaptable to ExMax-.. actuators
ExBox-3P Ex-e terminal box connectable to ExMax-.. actuators with 1 cable for On-off or 3-pos operation
ExBox-3P/SW Ex-e terminal box connectable to ExMax-.. actuators with 1 cable for On-off or 3-pos operation + 2 cable for external aux. switches type ExSwitch
ExBox-Y/S Ex-e terminal box connectable to ExMax-.. actuators with 2 cable, for modulating operation or 3-pos + integrated switches (HS)
ExBox-Y/S/SW Ex-e terminal box connectable to ExMax-.. actuators with 2 cable, for modulating or 3-pos operation with feedback signal + 2 cable for external aux. switches
ExBox-BF Ex-e terminal box connectable to ExMax-.. actuators with 1 cable, for all ExMax-...-BF
ExBox-BF/SW Ex-e terminal box connectable to ExMax-.. actuators with 1 cable, for all ExMax-...-BF + 2 cable for external aux. switches type ExSwitch
MKK-S Mounting bracket for ..Box-terminal boxes for direct coupling to ..Max-.. actuators size S
KB-S Mounting clamp for round damper shaft Ø 10 to 20 mm and squared shafts 10 to 16 mm, incl. bracket, connectable to all ExMax-.. size S
KB-A Shaft connection for damper shafts Ø ½ ″, adaptable for all North American ..Max-.. actuators size S
HV-SKU, HV-SLU Manual override, connectable to actuators size S. HV-SKU = short version, HV-SLU = long version for add. mounting of ..Box/..Switch
AR-12-xx Squared reduction part from 12 × 12 mm to shafts with 11 mm (type AR-12-11), 10 mm (type AR-12-10), 8 mm (type AR-12-08)
ExPro-TT-… Safety temperature trigger for fire dampers, switching at 71° /72°C, with 1 m cable, suitable only for ExMax-.. /RedMax-…-BF actuators !
EXC-DS1/VA Safety temperature sensor for duct mounting, potential free contact, switching at 70°C…160°C (10°C steps)
DWB-S Angle rotation limiter for mounting on actuator size S (details on request)
Retrofit-Kit-S Mechanical adaptation for mounting on ..Max actuators size S, required to replace a previous type EXT15..-F1, EXT12..-F16, EXT15.. or EXT30..
ADS Different adaptations for different valves available. Please don‘t hesitate to ask for technical solution
Special options and offshore kits see page 23
10 www.schischek.com
Price list Catalogue
Product 2021
ExMax 90° Ex quarter turn actuators size “M” for zone 1, 2, 21, 22
Explosion proof Features of ExMax-.. size M
ExMax-.. Size M Description Basics
Zone 1, 2, 21, 22 ExMax are, in acc. with type, for automation of air • 24…240 VAC/DC self adaptable power supply
Gas + Dust dampers, fire and smoke dampers, volume control, as • Up to 5 different running times adjustable on site
certified according to well as for ball valves, throttle valves and other quarter • 95° angle of rotation (5° pretension)
ATEX, IECEx, EAC, turn armatures. • 100% overload protected
INMETRO • Aluminium housing IP67, cable ~ 1 m
UL*, CSA*, Delivery: • −40°C (−20°C for type …F3) up to +40°C/+50°C
*…-A version only 1 actuator, ~ 1 m cable, allen key for manual override, • Emergency manual override
4 screws. • Squared shaft connection 16 × 16 mm
• Dimensions (H × W × D) 288 × 149 × 116 mm
Ex-d quarter turn actuators without spring return, 24 to 240 VAC/DC, for zone 1, 2, 21, 22
Type Torque Running time 90° Spring return Control mode Feedback Features Size
ExMax-50.75 50 Nm / 75 Nm 40/60/90/120/150 sec. - On-off, 3-pos - - M
ExMax- 100 100 Nm 40/60/90/120/150 sec. - On-off, 3-pos - - M
ExMax- 150 150 Nm 40/60/90/120 sec. - On-off, 3-pos - - M
ExMax-50.75-S 50 Nm / 75 Nm 40/60/90/120/150 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - M
ExMax- 100-S 100 Nm 40/60/90/120/150 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - M
ExMax- 150-S 150 Nm 40/60/90/120 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - M
ExMax-50.75-Y 50 Nm / 75 Nm 40/60/90/120/150 sec. - 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - M
ExMax- 100-Y 100 Nm 40/60/90/120/150 sec. - 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - M
Ex-d quarter turn actuators with spring return, 24 to 240 VAC/DC, for zone 1, 2, 21, 22
Type Torque Running time 90° Spring return Control mode Feedback Features Size
ExMax-30- F 30 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos - - M
ExMax-50- F 50 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos - - M
ExMax-60- F 60 Nm 40/60/90/120 sec. ~ 20 sec. On-off, 3-pos - - M
ExMax-30-SF 30 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - M
ExMax-50-SF 50 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - M
ExMax-60-SF 60 Nm 40/60/90/120 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - M
ExMax-30-YF 30 Nm 40/60/90/120/150 sec. ~ 20 sec. 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - M
ExMax-50-YF 50 Nm 40/60/90/120/150 sec. ~ 20 sec. 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - M
ExMax-30-BF 30 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) ExPro-TT-.. connector M
ExMax-50-BF 50 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) ExPro-TT-.. connector M
ExMax-60-BF 60 Nm 40/60/90/120 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) ExPro-TT-.. connector M
Ex-d quarter turn actuators with fast spring return for Offshore application, 24 to 240 VAC/DC, for zone 1, 2, 21, 22
Type Torque Running time 90° Spring return* Control mode Feedback Features Size
ExMax-30- F3 24 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off - - M
ExMax-50- F3 40 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off - - M
ExMax-30-SF3 24 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off 2 × aux. switches (5° /85°) - M
ExMax-50-SF3 40 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off 2 × aux. switches (5° /85°) - M
ExMax-30-BF3 24 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off 2 × aux. switches (5° /85°) ExPro-TT-.. connector M
ExMax-50-BF3 40 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off 2 × aux. switches (5° /85°) ExPro-TT-.. connector M
*At low temperatures the spring return time might vary. For further assistance please contact our sales team.
Accessories
Type Description/Technical data
ExSwitch External, adaptable, on site adjustable Ex-d auxiliary switch with 2 potential free contacts, adaptable to ExMax-.. actuators
ExBox-3P Ex-e terminal box connectable to ExMax-.. actuators with 1 cable for On-off or 3-pos operation
ExBox-3P/SW Ex-e terminal box connectable to ExMax-.. actuators with 1 cable for On-off or 3-pos operation + 2 cable for external aux. switches type ExSwitch
ExBox-Y/S Ex-e terminal box connectable to ExMax-.. actuators with 2 cable, for modulating operation or 3-pos + integrated switches (HS)
ExBox-Y/S/SW Ex-e terminal box connectable to ExMax-.. actuators with 2 cable, for modulating or 3-pos operation with feedback signal + 2 cable for external aux. switches
ExBox-BF Ex-e terminal box connectable to ExMax-.. actuators with 1 cable, for all ExMax-...-BF
ExBox-BF/SW Ex-e terminal box connectable to ExMax-.. actuators with 1 cable, for all ExMax-...-BF + 2 cable for external aux. switches type ExSwitch
MKK-M Mounting bracket for ..Box-terminal boxes for direct coupling to ..Max-.. actuators size M
HV-MU Manual override, connectable to actuators size M
AR-16-xx Squared reduction part from 16 × 16 mm to shafts with 14 mm (type AR-16-14), 12 mm (type AR-16-12)
ExPro-TT-… Safety temperature trigger for fire dampers, switching at 71° /72°C, with 1 m cable, suitable only for ExMax-.. /RedMax-…-BF actuators !
EXC-DS1/VA Safety temperature sensor for duct mounting, potential free contact, switching at 70°C…160°C (10°C steps)
DWB-M Angle rotation limiter for mounting on actuator size M
Retrofit-Kit-M Mechanical adaptation for mounting on ..Max actuators size M, required to replace a previous type EXT30..-F3, EXT50..-F3 or EXT50..
ADM Different adaptations for different valves available. Please don‘t hesitate to ask for technical solution
Special options and offshore kits see page 23
www.schischek.com 11
Price list Catalogue
Product 2021
Ex-d quarter turn actuators without spring return, 24 to 240 VAC/DC, for zone 2, 22
Type Torque Running time 90° Spring return Control mode Feedback Features Size
RedMax- 5.10 5 Nm / 10 Nm 3/15/30/60/120 sec. - On-off, 3-pos - - S
RedMax-15.30 15 Nm / 30 Nm 3/15/30/60/120 sec. - On-off, 3-pos - - S
RedMax- 5.10-S 5 Nm / 10 Nm 3/15/30/60/120 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - S
RedMax-15.30-S 15 Nm / 30 Nm 3/15/30/60/120 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - S
RedMax- 5.10-Y 5 Nm / 10 Nm 7,5/15/30/60/120 sec. - 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - S
RedMax-15.30-Y 15 Nm / 30 Nm 7,5/15/30/60/120 sec. - 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - S
Ex-d quarter turn actuators with spring return, 24 to 240 VAC/DC, for zone 2, 22
Type Torque Running time 90° Spring return Control mode Feedback Features Size
RedMax-5.10- F 5 Nm / 10 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos - - S
RedMax- 15- F 15 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos - - S
RedMax-5.10-SF 5 Nm / 10 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - S
RedMax- 15-SF 15 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - S
RedMax-5.10-YF 5 Nm / 10 Nm 7,5/15/30/60/120 sec. ~ 3 sec. / 10 sec. 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - S
RedMax- 15-YF 15 Nm 7,5/15/30/60/120 sec. ~ 3 sec. / 10 sec. 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - S
RedMax-5.10-BF 5 Nm / 10 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos 2 × aux. switches (5° /85°) ExPro-TT-.. connector S
RedMax- 15-BF 15 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos 2 × aux. switches (5° /85°) ExPro-TT-.. connector S
Ex-d quarter turn actuators with fast spring return for Offshore application, 24 to 240 VAC/DC, for zone 2, 22
Type Torque Running time 90° Spring return* Control mode Feedback Features Size
RedMax- 8- F1 6 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off - - S
RedMax-15- F1 12 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off - - S
RedMax- 8-SF1 6 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off 2 × aux. switches (5° /85°) - S
RedMax-15-SF1 12 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off 2 × aux. switches (5° /85°) - S
RedMax- 8-BF1 6 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off 2 × aux. switches (5° /85°) ExPro-TT-.. connector S
RedMax-15-BF1 12 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off 2 × aux. switches (5° /85°) ExPro-TT-.. connector S
*At low temperatures the spring return time might vary. For further assistance please contact our sales team.
Accessories
Type Description/Technical data
RedSwitch External, adaptable, on site adjustable auxiliary switch with 2 potential free contacts, adaptable to RedMax-.. actuators
RedBox-3P Ex-e terminal box connectable to RedMax-.. actuators with 1 cable for On-off or 3-pos operation
RedBox-3P/SW Ex-e terminal box connectable to RedMax-.. actuators with 1 cable for On-off or 3-pos operation + 2 cable for external aux. switches type RedSwitch
RedBox-Y/S Ex-e terminal box connectable to RedMax-.. actuators with 2 cable, for modulating operation or 3-pos + integrated switches (HS)
RedBox-Y/S/SW Ex-e terminal box connectable to RedMax-.. actuators with 2 cable, for modulating or 3-pos operation with feedback signal + 2 cable for external aux. switches
RedBox-BF Ex-e terminal box connectable to RedMax-.. actuators with 1 cable, for all RedMax-…-BF
RedBox-BF/SW Ex-e terminal box connectable to RedMax-.. actuators with 1 cable, for all RedMax-…-BF + 2 cable for external aux. switches type RedSwitch
MKK-S Mounting bracket for ..Box-terminal boxes for direct coupling to ..Max-.. actuators size S
KB-S Mounting clamp for round damper shaft Ø 10 to 20 mm and squared shafts 10 to 16 mm, incl. bracket, connectable to all RedMax-.. size S
KB-A Shaft connection for damper shafts Ø ½ ″, adaptable for all North American ..Max-.. actuators size S
HV-SKU, HV-SLU Manual override, connectable to actuators size S. HV-SKU = short version, HV-SLU = long version for add. mounting of ..Box/..Switch
AR-12-xx Squared reduction part from 12 × 12 mm to shafts with 11 mm (type AR-12-11), 10 mm (type AR-12-10), 8 mm (type AR-12-08)
ExPro-TT-… Safety temperature trigger for fire dampers, switching at 71° /72°C, with 1 m cable, suitable only for ExMax-.. /RedMax-…-BF actuators !
EXC-DS1/VA Safety temperature sensor for duct mounting, potential free contact, switching at 70°C…160°C (10°C steps)
DWB-S Angle rotation limiter for mounting on actuator size S (details on request)
Retrofit-Kit-S Mechanical adaptation for mounting on ..Max actuators size S, required to replace a previous type EXT15..-F1, EXT12..-F16, EXT15.. or EXT30..
ADS Different adaptations for different valves available. Please don‘t hesitate to ask for technical solution
Special options and offshore kits see page 23
12 www.schischek.com
Price list Catalogue
Product 2021
Ex-d quarter turn actuators without spring return, 24 to 240 VAC/DC, for zone 2, 22
Type Torque Running time 90° Spring return Control mode Feedback Features Size
RedMax-50.75 50 Nm / 75 Nm 40/60/90/120/150 sec. - On-off, 3-pos - - M
RedMax- 100 100 Nm 40/60/90/120/150 sec. - On-off, 3-pos - - M
RedMax- 150 150 Nm 40/60/90/120 sec. - On-off, 3-pos - - M
RedMax-50.75-S 50 Nm / 75 Nm 40/60/90/120/150 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - M
RedMax- 100-S 100 Nm 40/60/90/120/150 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - M
RedMax- 150-S 150 Nm 40/60/90/120 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - M
RedMax-50.75-Y 50 Nm / 75 Nm 40/60/90/120/150 sec. - 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - M
RedMax- 100-Y 100 Nm 40/60/90/120/150 sec. - 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - M
Ex-d quarter turn actuators with spring return, 24 to 240 VAC/DC, for zone 2, 22
Type Torque Running time 90° Spring return Control mode Feedback Features Size
RedMax-30- F 30 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos - - M
RedMax-50- F 50 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos - - M
RedMax-60- F 60 Nm 40/60/90/120 sec. ~ 20 sec. On-off, 3-pos - - M
RedMax-30-SF 30 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - M
RedMax-50-SF 50 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - M
RedMax-60-SF 60 Nm 40/60/90/120 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - M
RedMax-30-YF 30 Nm 40/60/90/120/150 sec. ~ 20 sec. 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - M
RedMax-50-YF 50 Nm 40/60/90/120/150 sec. ~ 20 sec. 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - M
RedMax-30-BF 30 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) ExPro-TT-.. connector M
RedMax-50-BF 50 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) ExPro-TT-.. connector M
RedMax-60-BF 60 Nm 40/60/90/120 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) ExPro-TT-.. connector M
Ex-d quarter turn actuators with fast spring return for Offshore application, 24 to 240 VAC/DC, for zone 2, 22
Type Torque Running time 90° Spring return* Control mode Feedback Features Size
RedMax-30- F3 24 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off - - M
RedMax-50- F3 40 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off - - M
RedMax-30-SF3 24 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off 2 × aux. switches (5° /85°) - M
RedMax-50-SF3 40 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off 2 × aux. switches (5° /85°) - M
RedMax-30-BF3 24 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off 2 × aux. switches (5° /85°) ExPro-TT-.. connector M
RedMax-50-BF3 40 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off 2 × aux. switches (5° /85°) ExPro-TT-.. connector M
*At low temperatures the spring return time might vary. For further assistance please contact our sales team.
Accessories
Type Description/Technical data
RedSwitch External, adaptable, on site adjustable auxiliary switch with 2 potential free contacts, adaptable to RedMax-.. actuators
RedBox-3P Ex-e terminal box connectable to RedMax-.. actuators with 1 cable for On-off or 3-pos operation
RedBox-3P/SW Ex-e terminal box connectable to RedMax-.. actuators with 1 cable for On-off or 3-pos operation + 2 cable for external aux. switches type RedSwitch
RedBox-Y/S Ex-e terminal box connectable to RedMax-.. actuators with 2 cable, for modulating operation or 3-pos + integrated switches (HS)
RedBox-Y/S/SW Ex-e terminal box connectable to RedMax-.. actuators with 2 cable, for modulating or 3-pos operation with feedback signal + 2 cable for external aux. switches
RedBox-BF Ex-e terminal box connectable to RedMax-.. actuators with 1 cable, for all RedMax-…-BF
RedBox-BF/SW Ex-e terminal box connectable to RedMax-.. actuators with 1 cable, for all RedMax-…-BF + 2 cable for external aux. switches type RedSwitch
MKK-M Mounting bracket for ..Box-terminal boxes for direct coupling to ..Max-.. actuators size M
HV-MU Manual override, connectable to actuators size M
AR-16-xx Squared reduction part from 16 × 16 mm to shafts with 14 mm (type AR-16-14), 12 mm (type AR-16-12)
ExPro-TT-… Safety temperature trigger for fire dampers, switching at 71° /72°C, with 1 m cable, suitable only for ExMax-.. /RedMax-…-BF actuators !
EXC-DS1/VA Safety temperature sensor for duct mounting, potential free contact, switching at 70°C…160°C (10°C steps)
DWB-M Angle rotation limiter for mounting on actuator size M
Retrofit-Kit-M Mechanical adaptation for mounting on ..Max actuators size M, required to replace a previous type EXT30..-F3, EXT50..-F3 or EXT50..
ADM Different adaptations for different valves available. Please don‘t hesitate to ask for technical solution
Special options and offshore kits see page 23
www.schischek.com 13
Price list Catalogue
Product 2021
Quarter turn actuators without spring return, 24 to 240 VAC/DC, for safe area
Type Torque Running time 90° Spring return Control mode Feedback Features Size
InMax- 5.10 5 Nm / 10 Nm 3/15/30/60/120 sec. - On-off, 3-pos - - S
InMax-15.30 15 Nm / 30 Nm 3/15/30/60/120 sec. - On-off, 3-pos - - S
InMax- 5.10-S 5 Nm / 10 Nm 3/15/30/60/120 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - S
InMax-15.30-S 15 Nm / 30 Nm 3/15/30/60/120 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - S
InMax- 5.10-Y 5 Nm / 10 Nm 7,5/15/30/60/120 sec. - 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - S
InMax-15.30-Y 15 Nm / 30 Nm 7,5/15/30/60/120 sec. - 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - S
Quarter turn actuators with spring return, 24 to 240 VAC/DC, for safe area
Type Torque Running time 90° Spring return Control mode Feedback Features Size
InMax-5.10-F 5 Nm / 10 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos - - S
InMax- 15-F 15 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos - - S
InMax-5.10-SF 5 Nm / 10 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - S
InMax- 15-SF 15 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - S
InMax-5.10-YF 5 Nm / 10 Nm 7,5/15/30/60/120 sec. ~ 3 sec. / 10 sec. 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - S
InMax- 15-YF 15 Nm 7,5/15/30/60/120 sec. ~ 3 sec. / 10 sec. 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - S
InMax-5.10-BF 5 Nm / 10 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos 2 × aux. switches (5° /85°) InPro-TT-.. connector S
InMax- 15-BF 15 Nm 3/15/30/60/120 sec. ~ 3 sec. / 10 sec. On-off, 3-pos 2 × aux. switches (5° /85°) InPro-TT-.. connector S
Quarter turn actuators with fast spring return for Offshore application, 24 to 240 VAC/DC, for safe area
Type Torque Running time 90° Spring return* Control mode Feedback Features Size
InMax- 8-F1 6 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off - - S
InMax-15-F1 12 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off - - S
InMax- 8-SF1 6 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off 2 × aux. switches (5° /85°) - S
InMax-15-SF1 12 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off 2 × aux. switches (5° /85°) - S
InMax- 8-BF1 6 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off 2 × aux. switches (5° /85°) InPro-TT-.. connector S
InMax-15-BF1 12 Nm 3/15/30/60/120 sec. ~ 1 sec. On-off 2 × aux. switches (5° /85°) InPro-TT-.. connector S
*At low temperatures the spring return time might vary. For further assistance please contact our sales team.
Accessories
Type Description/Technical data
InSwitch External, adaptable, on site adjustable auxiliary switch with 2 potential free contacts, adaptable to InMax-.. actuators
InBox-3P Terminal box connectable to InMax-.. actuators with 1 cable for On-off or 3-pos operation
InBox-3P/SW Terminal box connectable to InMax-.. actuators with 1 cable for On-off or 3-pos operation + 2 cable for external aux. switches type InSwitch
InBox-Y/S Terminal box connectable to InMax-.. actuators with 2 cable, for modulating operation or 3-pos + integrated switches (HS)
InBox-Y/S/SW Terminal box connectable to InMax-.. actuators with 2 cable, for modulating or 3-pos operation with feedback signal + 2 cable for external aux. switches
InBox-BF Terminal box connectable to InMax-.. actuators with 1 cable, for all InMax-…-BF
InBox-BF/SW Terminal box connectable to InMax-.. actuators with 1 cable, for all InMax-…-BF + 2 cable for external aux. switches type InSwitch
MKK-S Mounting bracket for ..Box-terminal boxes for direct coupling to ..Max-.. actuators size S
KB-S Mounting clamp for round damper shaft Ø 10 to 20 mm and squared shafts 10 to 16 mm, incl. bracket, connectable to all InMax-.. size S
KB-A Shaft connection for damper shafts Ø ½ ″, adaptable for all North American ..Max-.. actuators size S
HV-SKU, HV-SLU Manual override, connectable to actuators size S. HV-SKU = short version, HV-SLU = long version for add. mounting of ..Box/..Switch
AR-12-xx Squared reduction part from 12 × 12 mm to shafts with 11 mm (type AR-12-11), 10 mm (type AR-12-10), 8 mm (type AR-12-08)
InPro-TT-… Safety temperature trigger for fire dampers, switching at 71° /72°C, with 1 m cable, suitable only for InMax-…-BF actuators !
EXC-DS1/VA Safety temperature sensor for duct mounting, potential free contact, switching at 70°C…160°C (10°C steps)
DWB-S Angle rotation limiter for mounting on actuator size S (details on request)
Retrofit-Kit-S Mechanical adaptation for mounting on ..Max actuators size S, required to replace a previous type NOT15..-F1, NOT12..-F16, NOT15.. or NOT30..
ADS Different adaptations for different valves available. Please don‘t hesitate to ask for technical solution
Special options and offshore kits see page 23
14 www.schischek.com
Price list Catalogue
Product 2021
Quarter turn actuators without spring return, 24 to 240 VAC/DC, for safe area
Type Torque Running time 90° Spring return Control mode Feedback Features Size
InMax-50.75 50 Nm / 75 Nm 40/60/90/120/150 sec. - On-off, 3-pos - - M
InMax- 100 100 Nm 40/60/90/120/150 sec. - On-off, 3-pos - - M
InMax- 150 150 Nm 40/60/90/120 sec. - On-off, 3-pos - - M
InMax-50.75-S 50 Nm / 75 Nm 40/60/90/120/150 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - M
InMax- 100-S 100 Nm 40/60/90/120/150 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - M
InMax- 150-S 150 Nm 40/60/90/120 sec. - On-off, 3-pos 2 × aux. switches (5° /85°) - M
InMax-50.75-Y 50 Nm / 75 Nm 40/60/90/120/150 sec. - 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - M
InMax- 100-Y 100 Nm 40/60/90/120/150 sec. - 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - M
Quarter turn actuators with spring return, 24 to 240 VAC/DC, for safe area
Type Torque Running time 90° Spring return Control mode Feedback Features Size
InMax-30- F 30 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos - - M
InMax-50- F 50 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos - - M
InMax-60- F 60 Nm 40/60/90/120 sec. ~ 20 sec. On-off, 3-pos - - M
InMax-30-SF 30 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - M
InMax-50-SF 50 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - M
InMax-60-SF 60 Nm 40/60/90/120 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) - M
InMax-30-YF 30 Nm 40/60/90/120/150 sec. ~ 20 sec. 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - M
InMax-50-YF 50 Nm 40/60/90/120/150 sec. ~ 20 sec. 3-pos, 0…10 VDC, 4...20 mA 0…10 VDC, 4...20 mA - M
InMax-30-BF 30 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) InPro-TT-.. connector M
InMax-50-BF 50 Nm 40/60/90/120/150 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) InPro-TT-.. connector M
InMax-60-BF 60 Nm 40/60/90/120 sec. ~ 20 sec. On-off, 3-pos 2 × aux. switches (5° /85°) InPro-TT-.. connector M
Quarter turn actuators with fast spring return for Offshore application, 24 to 240 VAC/DC, for safe area
Type Torque Running time 90° Spring return* Control mode Feedback Features Size
InMax-30- F3 24 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off - - M
InMax-50- F3 40 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off - - M
InMax-30-SF3 24 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off 2 × aux. switches (5° /85°) - M
InMax-50-SF3 40 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off 2 × aux. switches (5° /85°) - M
InMax-30-BF3 24 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off 2 × aux. switches (5° /85°) InPro-TT-.. connector M
InMax-50-BF3 40 Nm 40/60/90/120/150 sec. ~ 3 sec. On-off 2 × aux. switches (5° /85°) InPro-TT-.. connector M
*At low temperatures the spring return time might vary. For further assistance please contact our sales team.
Accessories
Type Description/Technical data
InSwitch External, adaptable, on site adjustable auxiliary switch with 2 potential free contacts, adaptable to InMax-.. actuators
InBox-3P Terminal box connectable to InMax-.. actuators with 1 cable for On-off or 3-pos operation
InBox-3P/SW Terminal box connectable to InMax-.. actuators with 1 cable for On-off or 3-pos operation + 2 cable for external aux. switches type InSwitch
InBox-Y/S Terminal box connectable to InMax-.. actuators with 2 cable, for modulating operation or 3-pos + integrated switches (HS)
InBox-Y/S/SW Terminal box connectable to InMax-.. actuators with 2 cable, for modulating or 3-pos operation with feedback signal + 2 cable for external aux. switches
InBox-BF Terminal box connectable to InMax-.. actuators with 1 cable, for all InMax-…-BF
InBox-BF/SW Terminal box connectable to InMax-.. actuators with 1 cable, for all InMax-…-BF + 2 cable for external aux. switches type InSwitch
MKK-M Mounting bracket for ..Box-terminal boxes for direct coupling to ..Max-.. actuators size M
HV-MU Manual override, connectable to actuators size M
AR-16-xx Squared reduction part from 16 × 16 mm to shafts with 14 mm (type AR-16-14), 12 mm (type AR-16-12)
InPro-TT-… Safety temperature trigger for fire dampers, switching at 71° /72°C, with 1 m cable, suitable only for InMax-…-BF actuators !
EXC-DS1/VA Safety temperature sensor for duct mounting, potential free contact, switching at 70°C…160°C (10°C steps)
DWB-M Angle rotation limiter for mounting on actuator size M
Retrofit-Kit-M Mechanical adaptation for mounting on ..Max actuators size M, required to replace a previous type NOT30..-F3, NOT50..-F3 or NOT50..
ADM Different adaptations for different valves available. Please don‘t hesitate to ask for technical solution
Special options and offshore kits see page 23
www.schischek.com 15
Price list Catalogue
Product 2021
EASY INSTALLATION
COMPACT DIMENSIONS
16 www.schischek.com
Price list Catalogue
Product 2021
Actuators with spring return for 2-way and 3-way valves ExMax-.., RedMax-.., InMax-.. + LIN linear guide unit
Linear motion valve actuators with spring return
N ExMax+LIN from 500 to 3.000 N. Fixed stroke with 7.5, 10,
7,5 mm - 15, 20, 30, or 42 mm, for automation of globe- or
42 mm 3-way valves. Linkage to numerous valve types and
brands available.
normal wiring
Actuators for 2-way and 3-way valves ExRun-.., RedRun-.., InRun-.. valve actuators
Valve actuators from 500 to 10.000 N. On site ad-
N ExRun justable stroke from 5 to 60 mm, for automation of
5 mm - globe- or 3-way valves. Linkage to numerous valve
60 mm types and brands available.
normal wiring
www.schischek.com 17
Price list Catalogue
Product 2021
..Max-.. + LIN-.. Linear valve actuators size “S” and “M” with spring return
Explosion proof Industrial Features ..Max-.. + LIN-.. (size S and M)
ExMax-.. + LIN-.. RedMax-.. + LIN-.. InMax-.. + LIN-.. Description Basics
Zone 1, 2, 21, 22 Zone 2, 22 NOT Explosion proof ..Max-.. + LIN-.. linear valve actuators with • 24…240 VAC/DC self adaptable power
Gas + Dust Gas + Dust and only for spring return for automation of globe- or supply
certified according to certified according to use in safe area 3-way valves. • Running time 0,1…15 sec./mm ¹
ATEX, IECEx, EAC, ATEX, IECEx, EAC, IP66 Use as actuator with safety function, On-off • Stroke 7.5, 10, 15, 20, 30, 42 mm ¹
INMETRO, KOSHA1 INMETRO, or 3-pos. actuator or modulating actuator. • Force 500…3.000 N ¹
1
ExMax size S only UL*, CSA* • Spring return 3/10 sec. (size S),
Delivery: Linear unit, suitable for all ..Max-..-F
UL*, CSA* *…-A version only 20 sec. (size M) ¹
*…-A version only actuators size S or M.
• Control mode On-off, 3-pos., 0-10 VDC,
Required accessories: 4-20 mA ¹
Valve adaptation in accordance with valve man- • Aluminium housing, IP66 ²
ufacturer, type and nominal size (diameter), • Ambient temperature −20…+40 °C (T6),
terminal box, mounting bracket. −20…+50 °C (T5)
Ordering example: • Weight (incl. actuator) ~ 8 kg (size S),
Modulating valve actuator with spring return ~ 14 kg (size M) ¹
in Ex area zone 2, for a globe valve with • External terminal box optional ²
20 mm stroke and a required force of 1.500 N.
¹ in acc. with type | ² applies for actuator
Actuator: RedMax-30-YF
Linear adaptation: LIN-20
Valve adaptation: suitable for valve type on requ.
Required: Ex terminal box (RedBox-Y/S)
Required: Mounting bracket (MKK-M)
LIN-.. options
Type Description/Technical data
LIN-..-CT Offshore / marine coated aluminium housing, resistant against corrosive and /or maritime atmosphere. Lifting rod, connecting parts and screws in VA (surcharge)
ADLIN Different adaptations for different valves available. Please don‘t hesitate to ask for technical solution
Additional price for adaptation in stainless steel (VA) for CT version.
18 www.schischek.com
Price list Catalogue
Product 2021
At strokes between
two values use the
next higher linear unit
e.g. 24 mm stroke = LIN-30
Attention: Limitation of resolution at YF-actuators with strokes < nominal (motor blockade) !
Note the maximum force of the actuator to prevent damage to your valve !
Info: Suitable actuators with spring return see page 10-15.
Nominal force (N) at spring of actuator in relation of max. stroke of LIN at temperatures between −20…+40 °C
Type
Attention: Limitation of resolution at YF-actuators with strokes < nominal (motor blockade) !
Note the maximum force of the actuator to prevent damage to your valve !
Nominal force (N) at spring of actuator in relation of max. stroke of LIN at temperatures between 0…+40 °C
Type
Attention: Above mentioned values are nominal trusts with performed self adjustment drive !
The maximum trusts can read values which are up to three to four times higher than values of tables !
Without performed self adjustment drive there can occur much higher trust values, which can cause damages on the mentioned valve or linkages !
Spring return time depends on the effective required thrust and can exceed standard values !
Force
Schematic diagram
Open Close
www.schischek.com 19
Price list Catalogue
Product 2021
20 www.schischek.com
Price list Catalogue
Product 2021
Accessories
Type Description/Technical data
ExSwitch-R-L External, adaptable, on site adjustable Ex-d auxiliary switch linear for Ex/RedRun-.. with 2 potential free contacts, additionally Ex-e terminal box + mounting bracket necessary
InSwitch- R-L External, adaptable, on site adjustable auxiliary switch linear for InRun-.. with 2 potential free contacts, additionally terminal box + mounting bracket necessary
ExBox- SW Ex-e terminal box suitable for ExRun.. valve-actuators with external switches ExSwitch-R-L
RedBox-SW Ex-e terminal box suitable for RedRun.. valve-actuators with external switches ExSwitch-R-L
InBox- SW Terminal box suitable for InRun.. valve-actuators with external switches InSwitch-R-L
MKK-S Mounting-bracket suitable for ..Box-terminal boxes for direct mounting on ..Run actuators size S
HV-R Manual override suitable for ..Run valve actuators size S
GMB-1 Rubber bellow up to 60 mm, colour black
ADR Different adaptations for different valves available. Please don‘t hesitate to ask for technical solution
Special options and offshore kits see page 23
To select the right valve adaptation and get the right price information the ExRun-…
following data are required:
1. Valve manufacturer
RedRun-…
2. Valve type InRun-…
3. Valve nominal size (diameter) DN
For adaptations which are already designed by Schischek this information
is sufficient.
To design new adaptations we need additional details of the valve body
as well as drawings.
With the purchase order you have to provide actuator and valve type.
Adaption
www.schischek.com 21
Price list Catalogue
Product 2021
Special options quarter turn actuators size S ..Max-.. ¼ turn actuators size S
Special options quarter turn actuators size M ..Max-.. ¼ turn actuators size M
Weather shield for quarter turn and valve actuators ..Max-.. ¼ turn and ..Run valve actuators
WS-S ..Max-.. S/M Weather shield made of stainless steel for protec-
tion against weather influences like rain, sun or
WS-M ..Run-.. snow.
WS-R
22 www.schischek.com
Price list Catalogue
Product 2021
..Max-.. options
Type Description/Technical data
..Max-…- VAS Housing material of ..Max quarter turn actuator size S in stainless steel similar AISI 316, some parts nickel plated (surcharge)
..Max-…- VAM Housing material of ..Max quarter turn actuator size M in stainless steel similar AISI 316, some parts nickel plated (surcharge)
..Max-…- CTS Aluminium housing of ..Max quarter turn actuator size S with offshore/marine coating, resistant against corrosive and maritime atmosphere, some parts nickel plated (surcharge)
..Max-…- CTM Aluminium housing of ..Max quarter turn actuator size M with offshore/marine coating, resistant against corrosive and maritime atmosphere, some parts nickel plated (surcharge)
..Box-…/ VA Ex-e terminal-box, housing made of stainless-steel type AISI 316 L, some parts nickel plated (surcharge)
..Box-…/ CT Ex-e terminal-box, housing offshore / marine coated, resistant against corrosive /maritime atmosphere, some parts nickel plated (surcharge)
..Switch- CT Auxiliary switch for ..Max.., housing offshore / marine coated, resistant against corrosive /maritime atmosphere, some parts nickel plated (surcharge)
MKK- S/VA Mounting bracket, made of stainless-steel suitable for ..Box...VA for direct coupling to ..Max actuators size S
MKK- M/VA Mounting bracket, made of stainless-steel suitable for ..Box...VA for direct coupling to ..Max actuators size M
Kit-S8-Max Cable glands 2 × M16 × 1,5 mm Ex-e standard Ø 5-10 mm in brass nickel plated, 1 blind plug for replace the plastic version of quarter turn actuator ..Max
Kit-S8-Box Cable glands 4 × M20 × 1,5 mm Ex-e Ø 6-13 mm, brass nickel plated, for replace the plastic version of terminal ..Box
Kit-Offs-PMC-1C Protection metal conduit incl. SS terminal box and glands for 1 armoured cable
Kit-Offs-PMC-2C Protection metal conduit incl. SS terminal box and glands for 2 armoured cables
WS-S Weather shield in stainless steel, suitable for all ..Max actuators size S
WS-M Weather shield in stainless steel, suitable for all ..Max actuators size M
..Run-.. options
Type Description/ Technical data
..Run-…-CTS Aluminium housing with offshore/marine coating for ..Run valve actuator, resistant against corrosive /maritime atmosphere, some parts nickel plated (surcharge)
Kit-S8- Run Cable glands 2 × M20 × 1,5 mm Ex-e Ø 6-13 mm, brass nickel plated, for replace the plastic version of valve actuators ..Run
Kit-Offs-GL-Run Cable glands 2 × M25 × 1,5 mm Ex-d in brass nickel plated for armoured cables suitable for ..Run valve actuators
WS-R Weather shield in stainless steel, suitable for all ..Run valve actuators
www.schischek.com 23
Price list Catalogue
Product 2021
normal wiring
normal wiring
24 www.schischek.com
Price list Catalogue
Product 2021
ExPolar-…-MS/InPolar-…-MS
Type Adaptable on Operation temperature Supply Power* Installation area
ExPolar-…-MS ExMax-.. /RedMax size S −50 °C up to +60 °C 24 VAC/DC 48 VAC/DC 120 VAC 240 VAC 60 W zone 1, 2, 21, 22
InPolar- …-MS InMax-.. size S −50 °C up to +60 °C 24 VAC/DC 48 VAC/DC 120 VAC 240 VAC 60 W safe area
Supply voltage *Nominal value
Not suitable for VA versions !
ExPolar-…-MM/InPolar-…-MM
Type Adaptable on Operation temperature Supply Power* Installation area
ExPolar-…-MM ExMax-.. /RedMax size M −50 °C up to +60 °C 24 VAC/DC 48 VAC/DC 120 VAC 240 VAC 60 W zone 1, 2, 21, 22
InPolar- …-MM InMax-.. size M −50 °C up to +60 °C 24 VAC/DC 48 VAC/DC 120 VAC 240 VAC 60 W safe area
Supply voltage *Nominal value
Not suitable for VA versions !
Special option
Type Description/ Technical data
…Polar-…-…-CT Housing offshore / marine coated, resistant against corrosive /maritime atmosphere, some parts nickel plated (surcharge)
www.schischek.com 25
Price list Catalogue
Product 2021
REDUCED LIFE-CYCLE-COSTS
26 www.schischek.com
Price list Catalogue
Product 2021
www.schischek.com 27
Price list Catalogue
Product 2021
P M
Ex area
VAV
Safe area
PLC-System
Controller
ExReg-V..
Differential pressure
• 0…100/300/1.000 Pa,
depending on type (VAV)
28 www.schischek.com
Price list Catalogue
Product 2021
Accessories
Type Description/Technical data
MKR-VA/AL Mounting bracket for installation on round air-ducts (diameter up to 600 mm)
Kit 2 Includes 2 meter pressure hose (inner diameter 6 mm) and 2 plastic fittings
Special options and offshore kits see page 48
www.schischek.com 29
Price list Catalogue
Product 2021
EASY INSTALLATION
EASY PARAMETERISATION
30 www.schischek.com
Price list Catalogue
Product 2021
Content overview
Installation areas
Gas Dust Gas Dust Gas Dust
Product series Page 0 20 1 21 2 22 SA*
Analog sensors for measuring of volume flow, temperature, humidity, pressure/differential pressure
Overview analog sensors 30/36
ExCos-P differential pressure, VAV sensors ± 100… 7.500 Pa 37
RedCos-P differential pressure, VAV sensors ± 100… 7.500 Pa 37
InCos-P differential pressure, VAV sensors ± 100… 7.500 Pa 37
ExCos-D temperature and humidity transmitter for ExPro-C… sensors 34
RedCos-D temperature and humidity transmitter for ExPro-C… sensors 34
InCos-D temperature and humidity transmitter for InPro-C… sensors 34
ExPro-C… temperature and humidity sensors for operation in HVAC systems 35
InPro-C… temperature and humidity sensors for operation in HVAC systems 35
ExLine transmitter EXL-IM-9182-… for passive, potential free, analog ExSens sensors 36
ExSens analog, passive temperature- /humidity- /pressure sensors 37 () () ()
Special options for sensors
Overview special options for sensors 48
Overview heating system ..Polar for sensors 49
ExPolar / ExArctic heating system for sensors’ use in Ex areas down to −40 /−60 °C 49
InPolar / InArctic heating system for sensors’ use in safe area down to −40 /−60 °C 49
*SA = Safe area () = on request
www.schischek.com 31
Price list Catalogue
Product 2021
Pressure, Differential Pressure, VAV – analog, active ExCos-P-.., RedCos-P-.., InCos-P-.. Sensors
normal wiring
32 www.schischek.com
Price list Catalogue
Product 2021
ExCos-P-.. Differential pressure and volume control transmitter for zone 1, 2, 21, 22
Type Max. range Overload protected Measurement range, min. 20% of max. range Installation module
ExCos-P- 100 ± 100 Pa up to 25.000 Pa ± Measurement range free adjustable, min. range 20 Pa zone 1, 2, 21, 22
ExCos-P- 250 ± 250 Pa up to 25.000 Pa ± Measurement range free adjustable, min. range 50 Pa zone 1, 2, 21, 22
ExCos-P- 500 ± 500 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 100 Pa zone 1, 2, 21, 22
ExCos-P-1250 ± 1.250 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 250 Pa zone 1, 2, 21, 22
ExCos-P-2500 ± 2.500 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 500 Pa zone 1, 2, 21, 22
ExCos-P-5000 ± 5.000 Pa up to 75.000 Pa ± Measurement range free adjustable, min. range 1.000 Pa zone 1, 2, 21, 22
ExCos-P-7500 ± 7.500 Pa up to 120.000 Pa ± Measurement range free adjustable, min. range 1.500 Pa zone 1, 2, 21, 22
InCos-P-.. Differential pressure and volume control transmitter for safe area
Type Max. range Overload protected Measurement range, min. 20% of max. range Installation module
InCos-P- 100 ± 100 Pa up to 25.000 Pa ± Measurement range free adjustable, min. range 20 Pa safe area
InCos-P- 250 ± 250 Pa up to 25.000 Pa ± Measurement range free adjustable, min. range 50 Pa safe area
InCos-P- 500 ± 500 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 100 Pa safe area
InCos-P-1250 ± 1.250 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 250 Pa safe area
InCos-P-2500 ± 2.500 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 500 Pa safe area
InCos-P-5000 ± 5.000 Pa up to 75.000 Pa ± Measurement range free adjustable, min. range 1.000 Pa safe area
InCos-P-7500 ± 7.500 Pa up to 120.000 Pa ± Measurement range free adjustable, min. range 1.500 Pa safe area
www.schischek.com 33
Price list Catalogue
Product 2021
Example of combinations
34 www.schischek.com
Price list Catalogue
Product 2021
Accessories
Type Description/Technical data
MFK Mounting flange for duct-installation, for variable depth of immersion in the air duct
TH- VA Probe made of stainless-steel V4A 1.4571, length 150 mm for ..Pro-CT-200. Other lengths on request
Kit-FA-VA Sinter filter cap for humidity sensor (only up to 90 %rH)
MKR-VA/AL Mounting bracket for installation on round air-ducts (diameter up to 600 mm)
www.schischek.com 35
Price list Catalogue
Product 2021
36 www.schischek.com
Price list Catalogue
Product 2021
www.schischek.com 37
Price list Catalogue
Product 2021
EASY INSTALLATION
EASY PARAMETERISATION
38 www.schischek.com
Price list Catalogue
Product 2021
Content overview
Installation areas
Gas Dust Gas Dust Gas Dust
Product series Page 0 20 1 21 2 22 SA*
Switching sensors (thermostats, hygrostats, pressostats, fan belt protection, frost protection)
Overview switching (binary) sensors 38/44
ExBin-P pressure /differential pressure 0… 5.000 Pa 45
RedBin-P pressure /differential pressure 0… 5.000 Pa 45
InBin-P pressure /differential pressure 0… 5.000 Pa 45
ExBin-FR frost protection thermostat −10… +15 °C 42
RedBin-FR frost protection thermostat −10… +15 °C 42
InBin-FR frost protection thermostat −10… +15 °C 42
ExBin-A modules for adaptation of 1-5 passive, potential free, switching ExSens sensors 43
RedBin-A modules for adaptation of 1-5 passive, potential free, switching ExSens sensors 43
InBin-A modules for adaptation of 1-5 passive, potential free, switching sensors 43
ExBin-D temperature and humidity thermostat for ExPro-B… sensors 44
RedBin-D temperature and humidity thermostat for ExPro-B… sensors 44
InBin-D temperature and humidity thermostat for InPro-B… sensors 44
ExPro-B… thermostat /hygrostat sensors for operation in HVAC systems 45
InPro-B… thermostat /hygrostat sensors for operation in HVAC systems 45
ExLine switching module EXL-IR-9170-… for passive, potential free, switching ExSens sensors 46
ExSens switching, passive temperature- / humidity- /pressure sensors 47 () () ()
Special options for sensors
Overview special options for sensors 48
Overview heating system ..Polar for sensors 49
ExPolar / ExArctic heating system for sensors’ use in Ex areas down to −40 /−60 °C 49
InPolar / InArctic heating system for sensors’ use in safe area down to −40 /−60 °C 49
*SA = Safe area () = on request
www.schischek.com 39
Price list Catalogue
Product 2021
Pressure, differential pressure (Filter/fan belt monitoring) – active ExBin-P-.., RedBin-P-.., InBin-P-..
Binary pressure /differential pressure auxiliary
ΔP ExBin-P ΔP switch 0…5.000 Pa, for direct connection of air
hoses. IP66 Aluminium die-cast housing with
integrated terminal box. Set points adjust-
able on site, output 1 potential-free make contact.
Integrated indication of actual value, illuminated.
normal wiring 2-stage version optionally available.
1- or 2-channel switching module for passive sensors ExBin-A1/ A2, RedBin-A1/A2 + ExSens
switching sensors
°C ExBin-A 1- or 2-channel Ex-switching module for connection
%rH + ExSens of max. 2 passive, potential-free switching sensors.
Switching status display with LED. IP66 Aluminium
ΔP Ex-i wiring
(intrinsically safe)
die-cast housing with integrated terminal box. Output
depending on type 1-2 make contacts with collective
normal wiring supply unit.
Temperature, humidity, diff. pressure switching module for passive sensors EXL-IR-.. switching module + ExSens sensor
Ex-switching module for connection of one pas-
°C EXL-IR-.. sive, switching ExSens sensor, such as differential
%rH + ExSens pressure switch, frost protection thermostat or hy-
grostat through intrinsically safe electrical conduit.
ΔP Ex-i wiring Installation in control box onto DIN-rail. Output is
(intrinsically safe) potential-free.
normal wiring
40 www.schischek.com
Price list Catalogue
Product 2021
Accessories
Type Description/Technical data
Kit 2 Includes 2 meter pressure hose (inner diameter 6 mm) and 2 plastic fittings
MKR-VA/AL Mounting bracket for installation on round air-ducts (diameter up to 600 mm)
Special options and offshore kits see page 48
normal wiring
www.schischek.com 41
Price list Catalogue
Product 2021
Accessories
Type Description/Technical data
Kit 1.3 Capillary duct, assembly cramp and 4 assembly brackets for frost protection thermostat ..Bin-FR-3
Kit 1.6 Capillary duct, assembly cramp and 8 assembly brackets for frost protection thermostat ..Bin-FR-6
MKR-VA/AL Mounting bracket for installation on round air-ducts (diameter up to 600 mm)
Special options and offshore kits see page 48
normal wiring
42 www.schischek.com
Price list Catalogue
Product 2021
ExBin-A-.. Switching modules for 1 or 2 passive switching sensors for zone 1, 2, 21, 22
Type Description/Technical data Installation module Installation sensor*
ExBin-A-1 Module (1 channel) to connect 1 switching ExSens sensor in Ex area zone 1, 2, 21, 22 zone 0, 1, 2, 20, 21, 22
ExBin-A-2 Module (2 channel) to connect 2 switching ExSens sensors in Ex area zone 1, 2, 21, 22 zone 0, 1, 2, 20, 21, 22
*in acc. with certification of sensor !
InBin-A-.. Switching modules for 1 or 2 passive switching sensors for safe area
Type Description/Technical data Installation module Installation sensor
InBin-A-1 Module (1 channel) to connect 1 switching sensor safe area safe area
InBin-A-2 Module (2 channel) to connect 2 switching sensors safe area safe area
Accessories
Type Description/Technical data
MKR-VA/AL Mounting bracket for installation on round air-ducts (diameter up to 600 mm)
Special options and offshore kits see page 48
Ex-i wiring
(intrinsically safe)
normal wiring
www.schischek.com 43
Price list Catalogue
Product 2021
ExBin-D-.. thermostats and/or hygrostats, dependend on sensor type ExPro-B.. for zone 1, 2, 21, 22
Type Description/Technical data Installation module Installation ExPro-B.. sensor
ExBin-D Module for connection of one ExPro-B.. sensor as thermostat and /or hygrostat, 1-stage zone 1, 2, 21, 22 zone 1, 2, 21, 22
ExBin-D-2 Module for connection of one ExPro-B.. sensor as thermostat and /or hygrostat, 2-stage zone 1, 2, 21, 22 zone 1, 2, 21, 22
RedBin-D-.. thermostats and/or hygrostats, dependend on sensor type ExPro-B.. for zone 2, 22
Type Description/Technical data Installation module Installation ExPro-B.. sensor
RedBin-D Module for connection of one ExPro-B.. sensor as thermostat and /or hygrostat, 1-stage zone 2, 22 zone 1, 2, 21, 22
RedBin-D-2 Module for connection of one ExPro-B.. sensor as thermostat and /or hygrostat, 2-stage zone 2, 22 zone 1, 2, 21, 22
InBin-D-.. thermostats and/or hygrostats, dependend on sensor type InPro-B.. for safe area
Type Description/Technical data Installation module Installation InPro-B.. sensor
InBin-D Module for connection of one InPro-B.. sensor as thermostat and /or hygrostat, 1-stage safe area safe area
InBin-D-2 Module for connection of one InPro-B.. sensor as thermostat and /or hygrostat, 2-stage safe area safe area
Accessories
Type Description/Technical data
MKR-VA/AL Mounting bracket for installation on round air-ducts (diameter up to 600 mm)
Special options and offshore kits see page 48
Example of combinations
44 www.schischek.com
Price list Catalogue
Product 2021
Accessories
Type Description/Technical data
MFK Mounting flange for duct-installation, for variable depth of immersion in the air duct
TH- VA Probe made of stainless-steel V4A 1.4571, length 150 mm for ..Pro-BT-200. Other lengths on request
Kit-FA-VA Sinter filter cap for humidity sensor (only up to 90 %rH)
MKR-VA/AL Mounting bracket for installation on round air-ducts (diameter up to 600 mm)
www.schischek.com 45
Price list Catalogue
Product 2021
ExLine Ex-switching module for potential free, binary signals in zone 0, 1, 2, 20, 21, 22
Explosion proof Features EXL-IR-9170-11-12-11s C2304 SV
EXL-IR-9170-.. EXL-IR-9170-.. Description Basics
Zone 0, 1, 2, 20, 21, 22 Module with intrinsically safe circuit to change a passive • 24 V DC supply
Gas + Dust potential free binary signal (e.g. contact) into a contact in • Inverse-polarity protection
certified according to the safe area. • Input: passive potential free binary sensor
ATEX, IECEx, CSA, Module must be installed in the safe area, sensor in the • Output: potential free contact in the safe area
FM/UL, EAC, INMETRO, hazardous location ! • LED operation indication
KOSHA • Applicable up to SIL 2
Delivery: 1 Ex-i module for DIN rail mounting • Dimensions (W × H × D) 17,6 × 99 × 114,5 mm
• Rail mounting according DIN
Accessory (optional): binary sensors type ExSens • Installation in safe area
46 www.schischek.com
Price list Catalogue
Product 2021
Accessories
Type Description/Technical data
Installation-Kit-1 for frost protection sensor type TBK-FR-2G, PG entries for capillary, 6 brackets, support bracket
Install-Kit-2-DBK includes 2 meter pressure hose (inner diameter Ø 6 mm) 2 plastic fittings
www.schischek.com 47
Price list Catalogue
Product 2021
OCT
normal wiring VA/OVA CT/OCT
48 www.schischek.com
Price list Catalogue
Product 2021
normal wiring
ExPolar-…-CBR/InPolar-…-CBR
Type Adaptable on Operation temperature Supply Power* Installation area
ExPolar-…-CBR ExCos-../ ExBin-.. /ExReg-.. −40 °C up to +60 °C 24 VAC/DC 48 VAC/DC 120 VAC 240 VAC 60 W zone 1, 2, 21, 22
InPolar- …-CBR InCos-.. /InBin-.. /InReg-.. −40 °C up to +60 °C 24 VAC/DC 48 VAC/DC 120 VAC 240 VAC 60 W safe area
Supply voltage *Nominal value
Not suitable for VA versions !
Special option
Type Description/ Technical data
…Polar-…-…-CT Housing offshore / marine coated, resistant against corrosive /maritime atmosphere, some parts nickel plated (surcharge)
www.schischek.com 49
Price list Catalogue
Product 2021
ExMag Electric door holder magnets according ATEX for zone 1, 2, 21, 22
Explosion proof Features ExMag (EXM)
ExMag Magnet Description Basics
Zone 1, 2, 21, 22 ExMag door holder magnets are electric magnets • Electric magnets, silicone free
Gas + Dust to keep doors open or closed as long as supply voltage • Force in acc. with type
certified according to is available. • 24 VDC power supply
ATEX, IECEx • 1 m cable, silicone and halogen free
DNV-GL Delivery: 1 magnet • Ex-e terminal box is required for electrical connection
Ordering example: 650 N magnet + anchor • The max. AC-ripple must not exceed 20%
+ Ex-terminal box
Type to purchase: 1 × EXM-650 + 1 GH 6
+ 1 × EXC-K4/S
Accessories
Type Description/Technical data
GH-6 Anchor for EXM-650
GH-13/20 Anchor for EXM-1300 and EXM-2000
ExBox-3P Ex-e terminal box, IP66
EXC-K4/S Ex-e terminal box, IP66, with integrated fuse
EXC-T1 Ex-d push button
N1 supply unit Input 120…240 VAC, output 24 VDC, max. 0,5 A
ExComp components
Type Application Explosion proof Technical data
EXC-R 10/3... Switch II2G EEx ed IIC T6 10 A - 240/ 400 V - 2,5 /4,6 KW - 3 pole
EXC-R 20/3... Switch II2G EEx ed IIC T6 20 A - 240/ 400 V - 4,5 /9,0 KW - 3 pole
EXC-R 20/6... Switch II2G EEx ed IIC T6 20 A - 240/ 400 V - 4,5 /9,0 KW - 6 pole
EXC-R 40/3... Switch II2G EEx ed IIC T6 40 A - 240/ 400 V - 11 /20 KW - 3 pole
EXC-R 40/6... Switch II2G EEx ed IIC T6 40 A - 240/ 400 V - 11 /20 KW - 6 pole
EXC-DS1/VA Safety temperature sensor II2G EEx d IIC T6 Duct mounting, potential free contact, switching at 70°C…160°C (10°C steps)
50 www.schischek.com
Price list Catalogue
Product 2021
Content overview
Additional information Page
Product codes / definitions 52-53
Installation according to ATEX (Zone system) 54
Installation according to NEC 500 (Division system, North America) 55
Valve automation 56-57
Certification information 58-59
Information about ATEX directives 60
Labelling of explosion proof equipment according to ATEX 61
Explosion proof information 62
Information about zones, explosion groups and temperature classes 63
Ex applications 64-67
Rotork products (extraction) and service 68-73
Damper actuation focused 74-75
www.schischek.com 51
Product Catalogue
Max is a rotary (quarter turn) actuator for dampers or rotary valves, such as ball or butterfly valves
Run is a linear actuator for globe style control valves with a stroke between 5 and 60 mm
52
Product Catalogue
The number shows the max. adjustment range of the differential pressure switch in Pa
Bin switching measuring module with output as a potential free contact (1 opener or 1 closer)
T = temperature sensor
F = humidity sensor
TF = combisensor temperature / humidity
C = sensor for connection to Ex / Red/ InCos-D
B = sensor for connection to Ex / Red/ InBin-D
The number shows the control range of the controller in Pa (V-type only)
Reg controller
53
Product Catalogue
5 4 3 2 1
Valve actuator
ExRun../ RedRun..
1 Explosion proof actuator (ExMax / RedMax, ExRun / RedRun) 4 Supply or control cable
2 Supply cable approximate ~ 1 m (39.4") 5 Supply or control cable reaches into the safe area…
3 Junction box in increased safety Ex-e technology
54
Product Catalogue
max. 18"
2
7 6 5 4 3 1
Valve actuator
ExRun../ RedRun..*
1 Explosion proof actuator (ExMax / RedMax, ExRun / RedRun) 5 Connecting device, max. length 0,46 m (18")
2 Elbow device … 6 Seal fitting for horizontal or vertical conduits …
3 Connecting device … 7 Connecting device reaches into the safe area …
4 Conduit box …
55
Product Catalogue
Valve automation
Quarter-turn actuators Linear motion actuators
..Max ..Run
¼-turn actuator Linear actuator
Valve
example
Valve
example
56
Product Catalogue
Valve automation
Schischek valve linkages
~ 210 ~ 95
Option 1
You make the linkage yourself or source it
~ 80
somewhere else. In that case we would be
happy to provide you with all the actuator
dimensions necessary to do so. We can ~ 231
even give you STEP files you can import
directly into your CAD system.
36
M
4
(6
118,5
x)
18
-8
47,7
de
44
ep
70
74
37
35
V12
x)
(6
77,6 30
4
Title
4,
Option 21114 11
14
14
18
F04
F05
UNC
UNF
Zoll
Zoll
Zoll Zoll Zoll lb-in
-U-
Zoll
-V-
VA
AISI 316
17 17 22 F07 Increment
Schischek designs and delivers
19 the linkage
19 F10 mm mm
22 22 F12 Zoll Zoll
E
D
B C
Title
2011.070.E0-USA
Mühlsteig 45
. . . .
Gewerbegebiet Süd 5
. . . . D-90579 Langenzenn
57
Product Catalogue
ATEX is a commonly used synonym for the ATEX directives of the European
Union. The name is derived from the French term “ATmosphère EXplosible”.
The directive encompasses explosion protection directives 2014/34/EU for equip-
ment and 1999/92/EG for work areas. ATEX directives are devised by the Director
General of the EU commission Enterprise and Industry in cooperation with the
member states, standardization organizations (CEN, CENELEC) and so called
“Notified Bodies” such as BAM, PTB, or TUEV to name examples from Germany.
IP66
IP66 stands for Ingress Protection and denotes the protection of the device
against environmental factors, dust and rain for example, as well as protection of
living beings against dangers of touching high voltage circuits for example. The
first digit categorizes ingress of solid objects, the second ingress of water:
• IP6X = dust proof
• IPX6 = water jet proof (with specifies water pressure etc.)
KOSHA (Korea Occupational Safety and Health Agency) aims to contribute to the
national economy by maintaining and improving the safety and health conditions
at work through the efficient implementation of projects such as research and
development, promotion of industrial accident prevention technologies, provision
of technical assistance and training on occupational safety and health, inspection
on dangerous facilities and equipment.
58
Product Catalogue
In the context of the Eurasian Customs Union new technical rules were continu-
ously introduced since June 12, 2012 in order to create a common economic area.
This also affects equipment intended for use in potentially explosive atmospheres.
As part of this change, the GOST-R Explosion protection certificate was replaced
by the new technical regulation TR CU 012/2011 “On the safety of equipment
for use in potentially explosive atmospheres”. Instead of the previously required
GOST-R Ex certificate, it is now necessary to obtain a EAC certification.
Likewise, the RTN approval process has been replaced by the TR CU regulations.
59
Information about electrical explosion
protection according to ATEX directives *
Regulations for explosion protection The type plate and its components
ATEX Responsibilities especially to intrinsically safe circuits. Intrinsically
Since July 01, 2003 the rules of explosion protec- The responsibility for compliance with all regula- safe circuits and non-intrinsically safe circuits need
tion in the EU are set out by directive 94/9/EC (as of tions and directives, from production and planning to be separated. Minimum distances (tight string
April 20, 2016: 2014/34/EU) concerning equipment to installation, operation and maintenance, has length) between bare connections must be ob-
and protective systems for use in potentially explo- greatly increased. served, the cables must not produce any inadmis-
sive atmospheres. The aim was to replace national Each individual must be clear on the fact that he sible external inductance or capacitance. The maxi-
provisions in favor of uniform EU-wide rules and accepts personal responsibility as part of an overall mum admissible electrical limits of Ex-i equipment
regulations to establish uniform safety standards project: must be observed at all times. Intrinsically safe and
and to eliminate barriers to trade. In 1996, direc- • building owners non-intrinsically safe electrical circuits may not be
tive 94/9/EC (as of April 20, 2016: 2014/34/EU) • end-users connected together. Connections between two
was transposed into German law by the German • architects different intrinsically-safe circuits are permitted on
Equipment Safety Act (recast: Product Safety • consulting engineers / control companies the condition that a calculation shows that intrinsic
Act) and the Act on Explosion Protection, in short • inspection authorities safety is not compromised.
ExVO (11th GPSGV). While directive 94/9/EC (as • contractors / installers Intrinsically-safe circuits have to be marked as
of April 20, 2016: 2014/34/EU) defines construc- • manufacturers such. When marking is done by means of colors,
tion requirements, i.e. it is of particular interest to • product suppliers “light blue” color has to be used. This colour is rec-
manufacturers of explosion-proof equipment, op- • maintenance engineers ommended for all intrinsically safe circuits to pre-
erators of installations have to observe directive Example, for the labelling of a quarter turn actuator vent confusion and/or connection to a non-intrinsi-
1999/92/EC for the safety of workers endangered Manufacturer’s name, manufacturer’s address, cally safe circuit. Examples: cables, wiring, cable
by explosive atmospheres. In Germany, this direc- designation of type, electrical data (V, A, W, Hz) conduits, terminals, terminal boxes, cable glands ...
tive is transposed into German law by the Industrial ambient temperature if different from −20 to +40°C, A minimum distance of 50 mm between intrinsi-
Safety and Health Act (BetrSichV). unit serial number, in addition to the classification cally safe and non-intrinsically safe circuits has to
On April 20, 2016, the ATEX directive 94/9/EC will of Ex protection. be maintained, and a minimum distance of 6 mm
be replaced by the new directive 2014/34/EU. Many between two different intrinsically safe circuits.
changes in the new directive are not relevant for Ser.-No. 090.1036 19384001 During installation the cables of intrinsically safe
manufacturers of explosion-proof equipment.Most ExMax-15-SF and non-intrinsically safe circuits are to be routed
EPS 17 ATEX 1 132 X
of the essential content remains the same, for ex- IECEx EPS 17.0065X separately !
II 2 (2) G Ex db [ib Gb] IIC T6, T5 Gb
ample, Annex I “Criteria determining the classifica- II 2 (2) D Ex tb [ib Db] IIIC T80°C, T95°C Db Suggestion on how to design a panel
tion of equipment-groups into categories” and the It is necessary to keep intrinsically safe and non-
essential health and safety requirements (EHSR; intrinsically safe equipment separate. It is recom-
Annex II) of the directive do not change. Important
for both manufacturers as well as operators and Correct installation mended, in this case, that a sufficient distance be
kept, to avoid extra costs in the future.
plant manufacturers is that EC-type examination For the installation of electrical systems in areas Large transformers, frequency converters, large
certificates issued in accordance with directive with explosive atmospheres of group II, standards relays and other electric equipment that may in-
94/9/EC are still valid. A recertification according IEC 60 079-14 (EN 60079-14) or VDE 0165 apply. fluence intrinsically safe circuits by inductance or
to directive 2014/34/EU is therefore not required. In Germany however solely the Technical Rules capacitance should be installed at a sufficient dis-
ExVO for Occupational Safety grant the presumption of tance. As a precaution Ex-i equipment should have
Directive on the distribution of equipment and pro- conformity with the Industrial Safety and Health Act a suitable cover to protect it from incorrect han-
tection systems for potentially explosive areas – ex- (BetrSichV). dling. The appropriate standards and regulations
plosion protection ordinance 11.GSGV. Electric circuits of protection types d, e, q, o, m, p must be observed.
Ordinance on Industrial Safety and Health Installation in the control panel is identical to
Ordinance concerning the protection of safety and
health in the provision of work equipment and its
“standard” installation, however the procedures
for connecting Ex equipment must be followed. ATEX
use at work, concerning safety when operating in- This relates, for example to voltage, current, fuses
stallations subject to monitoring and concerning the and motor protection equipment, etc. The require-
organization of industrial safety and health at work. ments for specific products need to be taken from
their corresponding test certificates, standards and
Atmosphère
Certificates
Corresponding approvals and certificates are
required for electrical explosion protected equip-
regulations as well as from the user manual. It is
only permitted to work on electric circuits within the Explosible
Ex-area (for example when making connections in
ment. Testing must be carried out by an official test-
an Ex-e terminal box) when the voltage has been
ing agency (Notified Body, for example the PTB,
switched off. An Ex-e terminal box should only be
Physikalisch Technische Bundesanstalt in Braun-
opened after the voltage has been switched off.
schweig/Federal German Physical and Technical
Institute in Braunschweig). ATEX approvals are Electric circuits of protection type “i” (intrinsic safety)
also accepted in many countries and states outside For the planning and operation of switchgears and
Europe. control systems installed in the safe area, but which
contain circuits leading into the Ex-area, certain
requirements need to be considered. This applies
*from April 20, 2016 replacement of ATEX 94/9/EC directives with directives according to ATEX 2014/34/EU
60
Product Catalogue
Labelling of explosion
Labelling of explosion proof according
proof equipment equipment according
to ATEX 2014/34/EUto ATEX 2014/34/EU
Classification and labelling
Classification of hazardous
and labelling locations
of hazardous locations Classification
Classification Explosion
Explosion groups & classes
groups & Temperature Temperature classes
(gases, mists, vapours)
Flammable Hazardous locations Classification Product classification Equipment Explosion Examples depending on
medium Probability of a of hazardous protection group - explosion group
potentially explosive locations level - temperature class
atmosphere occuring Product Product (EPL)
group category
Ammonia Ethanol Petrol Acetal-de-
Continuously, for long Methane Cyclohe- Diesel fuel hyde
periods or frequently Zone 0 II IIA Ethane xene Fuel oil
Propane n-Butane n-Hexane
IIB
Gases, City gas
Acrylic
Ethylene
Ethylene
Ethyl glycol Ethyl ether
mists, Likely to occur Zone 1 II 1G Ga IIC nitrile oxide
Carbon
hydrogen
vapours
2G Gb
Hydrogen Acetylene Carbon
Infrequently and for short disulphide
periods only Zone 2 II 3G Gc
II 2 D Ex tb IIIC T80°C Db
Prevents transmission of flameproof da 0,1, 2 IIIA flammable fibres
the explosion outside enclosure Exd db 1, 2 EN 60079-1
IIIB
dc 2
IIIC non conductive dust
For common use –
Prevents high increased Exe eb 1, 2
EN 60079-7
temperatures and sparks safety ec 2 conductive dust
Protection principle Type of Code Sym- To use CENELEC IP Protection Protection Application Code
protection bol in zone against against
solids/dust water
Protection principle – Type of protection – EN 60079-0 General Requirements Ingress Protection EN 60529 Further information
© Rotork GmbH | Schischek Explosionproof
61
Product Catalogue
Explosion
Deflagration
Combustion
Reaction velocity
62
Product Catalogue
63
Product Catalogue
Ex applications
Air safety dampers • Air control dampers • Fire / smoke dampers
64
Product Catalogue
Ex applications
Heating • Cooling • Humidification • Diff.pressure control • VAV
Humidity control
In this example the control system consists of a valve actuator and
an ExCos-D transmitter with ExPro sensor. The combination can be
installed directly into an Ex area. The transmitter converts the sensor
signal into an active signal (0...10 VDC or 4...20 mA) for input in a
PLC system. The output signal from the controller goes directly to the
actuator.
Between sensor and controller an additional Ex-i module and intrin-
sically safe (IS) circuit wiring are not required. For the actuator and
transmitter the maximum permissible surface temperatures have to be
taken into account.
65
Product Catalogue
Ex applications
Thermostats • Humidistats • Pressostats • Filter monitoring
Thermostats
ExBin-D... modules with ExPro-BT... sensor are thermostats for use
in potentially explosive atmospheres. No intrinsically-safe electrical
circuits and no switching amplifiers need to be installed in the electri-
cal control-panel. The module may be installed directly in an Ex area,
depending on demand in zone 1, 2, 21 or 22.
The output contact can be used for follow-up functions (relays, con-
tacts, direct circuit, ...).
Hygrostats
ExBin-D... modules with ExPro-BF... sensor are hygrostats for use in
potentially explosive atmospheres. No intrinsically-safe electrical cir-
cuits and no switching amplifiers need to be installed in the electrical
control-panel. The module may be installed directly in an Ex area, de-
pending on demand in zone 1, 2, 21 or 22.
The output contact can be used for follow-up functions (relays, con-
tacts, direct circuit, ...).
Filter monitoring
ExBin-P... modules are pressostats like Ex-differential pressure switch-
es, e.g. for filter monitoring in potentially explosive atmospheres. No
intrinsically-safe electrical circuits and no switching amplifiers need to
be installed in the electrical control-panel. The module may be installed
directly in an Ex area, depending on demand in zone 1, 2, 21 or 22.
The output contact can be used for follow-up functions (relays, con-
tacts, direct circuit, ...).
66
Product Catalogue
Ex applications
Drive (Fan) belt monitoring • Frost protection
Frost protection
ExBin-FR... are sensors for frost protection monitoring with a
capillary as measuring element for use in potentially explo-
sive atmospheres. No intrinsically-safe electrical circuits and no
switching amplifiers need to be installed in the electrical control-
panel. The module may be installed directly in an Ex area, depending
on demand in zone 1, 2, 21 or 22.
The output contact can be used for follow-up functions (relays, con-
tacts, direct circuit, ...).
Duct Fan
Fan belt monitoring via Namur sensor
EXL-IR-9170 switching modules in combination with connected Namur
sensor (inductive proximity switch) are suitable for non-contact V-belt
monitoring of fans in hazardous locations.
The switching module is installed in the safe area. Wiring is via an in-
trinsically safe Ex-i circuit. The proximity switch type Namur is installed
Ex area
normal circuit
Ex-i circuit
EXL-IR-9170 (intrinsically safe)
67
Keeping the World Flowing
Since 1957, Rotork has grown to be a major international business with sub-
sidiaries all around the world.
"For over sixty years, en-
When you turn on a tap or switch on a light, turn on a kettle or put fuel
in your car, a flow control product is being used somewhere in the process
gineers have relied upon
of delivering that service. Rotork for innovative,
dependable solutions to
We are recognised as global leaders, designing and building the most
reliable products, backed up by highly acclaimed customer service. manage the flow of
liquids, gases and pow-
Rotork has established manufacturing facilities, a global network of local of-
ders. From safety systems
fices and agents who can truly provide a worldwide service. You will be able
to locally source Rotork's products, supported by life-of-plant maintenance, that may be needed
repair and upgrade services. just once in a lifetime to
process controls that are
Committed to Innovation constantly on the move,
At every stage in the company's history, Rotork's engineers have focused Rotork flow control
on solving customer challenges and developing new solutions with levels products remain the clear
of engineering skill and creativity that our competitors still cannot match. choice, worldwide".
With every product that Rotork develops, you can be sure of one thing:
That quality and reliability are an integral part.
68
Electric Control Valve Actuators and Gears (Extraction)
IQT CK
range range
Multi-turn and part-turn electric actuators Modular design electric valve actuators
IQT part-turn 1-phase, 3-phase and DC electric actuators are CK range actuators are suitable for valves in non-hazardous
designed for isolating or regulating duties (S2 & S3 /Class A & B) locations. The modular product range facilitates a number of dif-
of up to 1,200 starts per hour. ferent control package configurations to meet your application
• Direct torque output range from 50 to 3,000 Nm requirements.
• Continuous position tracking at all times, even without power • Multi-turn output torque up to 10,800 Nm (8,000 lbf.ft)
• Extended life and mounting in any orientation with oil bath • Part-turn output torque up to 205,600 Nm (151,600 lbf.ft)
lubrication • Modular design provides an off-the-shelf solution for spares and
• IP66/68 certified upgrading
• Safe, motor-independent, handwheel operation available at • Plug and socket connection for easier field wiring
all times • Continuous valve position indication even during power loss
• Explosionproof and certified for safety applications (SIL2/3) • Non-intrusive setting via infrared or optional Bluetooth® with the
are available intelligent CKc - Centronik module
• Hollow output drive to accept rising valve stems
• Detachable base options
• Secure manual handwheel drive fully independent of the motor
drive train
• IP68 rating (8 m for 96 hrs) as standard provides enhanced
environmental protection
ROM/ROMpak Gears…
ranges ranges
Compact and lightweight part-turn actuators Valve gear operators and accessories
Electric, compact and lightweight part-turn actuators with Rotork offer a wide range of gearboxes spanning the following
efficient and simple gearing. categories:
• Torque range 8 to 800 Nm (6 to 590 lbf.ft) • Part-turn output manual gear operators
• On/off duty, manual override, self-locking, ISO flanges • Part-turn output motorised gear operators
• Available with local controls and phase rotation correction • Multi-turn output manual gear operators
• Wide range of supply voltages available • Multi-turn output motorised gear operators
• 1-phase, 3-phase and DC power supply options • Specialised application gear operators
• Watertight IP68 rating • Mounting kits and accessories
• High speed variant available
• Mechanical and LED local position indication
• Options: Bus communication, analogue control and feedback
69
Electric Control Valve Actuators (Extraction)
CMA
range
CVA
range
70
Fluid Power Actuators (Extraction)
K-TORK GT /GTS
range ranges
RC200 Skilmatic SI
range range
71
Site Services
Rotork Site Services provide our customers with the
extensive onsite technical expertise required to ensure the
successful functioning of installations anywhere around
„In each of our business ar-
the globe.
eas our Site Services Team
We provide a comprehensive selection of programs is dedicated to customer
around the topic Flow Control: service and support from
the commissioning of new
• Emergency service and scheduled service installations and support-
ing customised automated
• Actuator overhauls
processes to implementing
• Status checks retrofit packages.
The teams are available in
• Preventive maintenance service centers worldwide
• Installation of actuators on existing valves and are supplemented by
factory-trained specialists“.
• Plant shutdowns
• Plant optimization
72
High Plant Availability through Preventative Maintenance
Rotork actuators are recognised as the best in the world for
reliability and safety in the most demanding applications.
To maintain this hard-earned leadership position, Rotork is
"Rotork actuators incorpo-
committed to helping clients to maximise the continuous, fault- rate intelligence to satisfy
free operation and working life of all their actuators. the increasing requirements
Rotork have over 60 years of flow control experience with of actuation, now and in
expertise in all actuation applications. Let Rotork leverage this the future. Intelligent Asset
Management makes it is easy
expertise during your planned maintenance periods to maximise
to identify potential issues,
operating efficiency of your site while reducing shutdown
plan predictive maintenance
duration and frequency. and improve your operating
processes".
73
Damper Actuation Focused
Switch boxes
and position indicators
Temperature triggers
for fire-dampers
Manual operators
74
One Air-Damper – Various Actuator Solutions!
Pneumatic actuators
such as rack and pinion,
scotch/yoke, vane,
electro-hydraulic
Spring assembly
Positioners
Rotork
[email protected]
+49 9101 9081-15
75
Rotork-Schischek Sales Worldwide
Greenland
Sweden
Iceland
Finland R u s s i a
Norway
Estonia
Neth. Belarus
Ireland Poland
Germany
Bel.
Lux. Czech Rep. Ukraine
Licht. Austria
Slovakia Kazakhstan
Mold.
France Switz. Slovenia
Hungary Mongolia
Croatia Romania
Italy Bos. &
Herz. Serb.
Mont. Bulgaria
Albania Mace.
Georgia Uzbekistan Kyrgyzstan
Portugal Spain Armenia Azerb. N. Korea
United States Greece
Turkey Turkmenistan Tajikistan
Japan
Gibraltar S. Korea
Malta Cyprus Syria C h i n a
Morocco Tunisia
Lebanon
Iraq Iran Afghanistan
Israel
Jordan
Algeria Kuwait Nepal
Libya Pakistan Bhutan
Western Sahara Egypt Bahrain
Qatar
Mexico Bahamas (Occupied by Morocco)
Bangladesh
Saudi Arabia U.A.E.
Cuba India Hong Taiwan
Dom. Rep.
Mauritania Laos Kong
Puerto Rico
Oman
Jamaica Haiti Mali Niger
Belize Chad
Honduras Cape Verde Senegal Eritrea Yemen Thailand Philippines
Guatemala
Nicaragua Gambia Sudan Cambodia
El Salvador Guinea-Bissau Burkina Faso Dijbouti Vietnam
Trinidad & Tobago Benin
Costa Rica
Panama Guinea Nigeria
Venezuela Guyana Sierra Leone
Cote Togo Ethiopia
d'Ivoire
Ghana Central African Republic Palau
French Guiana Sri Lanka Brunei
Liberia Cameroon
Colombia Suriname
Somalia Malaysia
Equatorial Guinea Uganda
Kenya Singapore
Congo
Ecuador Gabon Rwanda
Dem. Rep.
of Congo Burundi Papua
I n d o n e s i a New Guinea
Peru Tanzania Solomon Islands
B r a z i l East Timor
Angola Somoa
Malawi
Zambia Vanuatu
Fiji
Bolivia
Zimbabwe Mauritius
Namibia Mozambique
Botswana Tonga
Paraguay
Chile A u s t r a l i a
Madagascar
Swaziland
Lesotho
South Africa
Argentina Uruguay
New Zealand
Rotork GmbH
Muehlsteig 45
90579 Langenzenn
Germany
Tel. +49 9101 9081- 0
Fax +49 9101 9081-77
[email protected]
www.schischek.com
PUB113-001-00_02/24 Technical changes, product discontinuations, literal errors and mistakes reserved.
www.schischek.com