Page 1/7
Safety Data Sheet
according to GHS
Printing date 18.08.2020 Version number 12 Revision: 27.11.2019
* SECTION 1: Identification
· 1.1 Product identifier
· Trade name: B-7502 BOYSEN PERMACOAT SEMIGLOSS LATEX WINTER MORNING
· 1.2 Relevant identified uses of the substance or mixture and uses advised against
No further relevant information available.
· Application of the substance / the mixture
Boysen Permacoat Latex Paint is a durable 100% acrylic, non-toxic, lead-free water based paint with excellent
hiding and stain resistance. It can be applied on new or previously painted masonry and and fiberboard
surfaces.
· 1.3 Details of the supplier of the safety data sheet
· Manufacturer/Supplier:
Pacific Paint (Boysen) Philippines, Inc.
292 D. Tuazon St., Quezon City
1115 Philippines
· Further information obtainable from: Product safety department
· 1.4 Emergency telephone number:
Telephone Nos. : +63 2 8365 0505 to 09; +63 2 8365 0561 to 64
Facsimile Nos. : +63 2 8367 8878; +63 2 8361-7164; +63 2 8367-8881
Email Address : [email protected]
Website Address : www.boysen.com.ph
* SECTION 2: Hazard identification
· 2.1 Classification of the substance or mixture
· Classification according to Regulation (EC) No 1272/2008
The product is not classified, according to the CLP regulation.
· 2.2 Label elements
· Labelling according to Regulation (EC) No 1272/2008 Void
· Hazard pictograms Void
· Signal word Void
· Hazard statements Void
· 2.3 Other hazards
· Results of PBT and vPvB assessment
· PBT: Not applicable.
· vPvB: Not applicable.
* SECTION 3: Composition / information on ingredients
· 3.2 Chemical characterisation: Mixtures
· Description: Mixture of substances listed below with nonhazardous additions.
· Dangerous components:
CAS: 13463-67-7 titanium dioxide Acute Tox. 5, H333 10-25%
EINECS: 236-675-5
· Additional information:
For the wording of the listed hazard phrases refer to section 16.
CAS: 25265-77-4 2,2,4-trimethyl-1,3 pentanediol-monoisobutyrate 2.5%
Texanol
Acute Tox. 3, H331; Acute Tox. 5, H303
(Contd. on page 2)
PH
49.0
Page 2/7
Safety Data Sheet
according to GHS
Printing date 18.08.2020 Version number 12 Revision: 27.11.2019
Trade name: B-7502 BOYSEN PERMACOAT SEMIGLOSS LATEX WINTER MORNING
(Contd. of page 1)
CAS: 7732-18-5 water, distilled, conductivity or of similar purity 50-100%
EINECS: 231-791-2
SECTION 4: First-aid measures
· 4.1 Description of first aid measures
· After inhalation:
Supply fresh air and to be sure call for a doctor.
In case of unconsciousness place patient stably in side position for transportation.
· After skin contact: Immediately wash with water and soap and rinse thoroughly.
· After eye contact: Rinse opened eye for several minutes under running water.
· After swallowing: If symptoms persist consult doctor.
· 4.2 Most important symptoms and effects, both acute and delayed No further relevant information available.
· 4.3 Indication of any immediate medical attention and special treatment needed
No further relevant information available.
SECTION 5: Fire-fighting measures
· 5.1 Extinguishing media
· Suitable extinguishing agents:
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
· 5.2 Special hazards arising from the substance or mixture No further relevant information available.
· 5.3 Advice for firefighters
· Protective equipment: No special measures required.
SECTION 6: Accidental release measures
· 6.1 Personal precautions, protective equipment and emergency procedures Not required.
· 6.2 Environmental precautions:
Do not allow product to reach sewage system or any water course.
Inform respective authorities in case of seepage into water course or sewage system.
Dilute with plenty of water.
Do not allow to enter sewers/ surface or ground water.
· 6.3 Methods and material for containment and cleaning up:
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Ensure adequate ventilation.
· 6.4 Reference to other sections
See Section 7 for information on safe handling.
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.
SECTION 7: Handling and storage
· 7.1 Precautions for safe handling
Ensure good ventilation/exhaustion at the workplace.
Prevent formation of aerosols.
· Information about fire - and explosion protection: No special measures required.
(Contd. on page 3)
PH
49.0
Page 3/7
Safety Data Sheet
according to GHS
Printing date 18.08.2020 Version number 12 Revision: 27.11.2019
Trade name: B-7502 BOYSEN PERMACOAT SEMIGLOSS LATEX WINTER MORNING
(Contd. of page 2)
· 7.2 Conditions for safe storage, including any incompatibilities
· Storage:
· Requirements to be met by storerooms and receptacles: No special requirements.
· Information about storage in one common storage facility: Not required.
· Further information about storage conditions: None.
· 7.3 Specific end use(s) No further relevant information available.
SECTION 8: Exposure controls / personal protection
· Additional information about design of technical facilities: No further data; see item 7.
· 8.1 Control parameters
· Ingredients with limit values that require monitoring at the workplace:
13463-67-7 titanium dioxide
PEL (USA) Long-term value: 15* mg/m³
*total dust
REL (USA) See Pocket Guide App. A
TLV (USA) Long-term value: 10 mg/m³
withdrawn from NIC
330-54-1 diuron(ISO)
REL (USA) Long-term value: 10 mg/m³
TLV (USA) Long-term value: 10 mg/m³
· Additional information: The lists valid during the making were used as basis.
· 8.2 Exposure controls
· Personal protective equipment:
· General protective and hygienic measures:
Immediately remove all soiled and contaminated clothing
Wash hands before breaks and at the end of work.
· Respiratory protection:
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure
use self-contained respiratory protective device.
· Protection of hands:
Protective gloves
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the
chemical mixture.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation
· Material of gloves
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality
and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the
resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the
application.
· Penetration time of glove material
The exact break through time has to be found out by the manufacturer of the protective gloves and has to be
observed.
(Contd. on page 4)
PH
49.0
Page 4/7
Safety Data Sheet
according to GHS
Printing date 18.08.2020 Version number 12 Revision: 27.11.2019
Trade name: B-7502 BOYSEN PERMACOAT SEMIGLOSS LATEX WINTER MORNING
(Contd. of page 3)
· Eye protection: Goggles recommended during refilling
* SECTION 9: Physical and chemical properties
· 9.1 Information on basic physical and chemical properties
· General Information
· Appearance:
Form: Liquid
Colour: According to product specification
· Odour: Characteristic
· Odour threshold: Not determined.
· pH-value: 8 - 9.5
· Change in condition
Melting point/freezing point: Not determined
Initial boiling point and boiling range: 100 °C
· Flash point: Not applicable.
· Flammability (solid, gas): Not applicable.
· Ignition temperature: Not determined
· Decomposition temperature: Not determined.
· Auto-ignition temperature: Product is not selfigniting.
· Explosive properties: Product does not present an explosion hazard.
· Explosion limits:
Lower: Not determined.
Upper: Not determined.
· Vapour pressure: Not determined
· Density: 9.54 - 9.94 lbs/ gal
· Relative density Not determined.
· Vapour density Not determined.
· Evaporation rate Not determined.
· Solubility in / Miscibility with
water: Fully miscible.
· Partition coefficient: n-octanol/water: Not determined.
· Viscosity: 86 - 91 KU
· Dynamic: Not determined.
· Kinematic: Not determined.
· Solvent content:
VOC (EC) 4.60 g/Li
· 9.2 Other information No further relevant information available.
SECTION 10: Stability and reactivity
· 10.1 Reactivity No further relevant information available.
· 10.2 Chemical stability
· Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications.
(Contd. on page 5)
PH
49.0
Page 5/7
Safety Data Sheet
according to GHS
Printing date 18.08.2020 Version number 12 Revision: 27.11.2019
Trade name: B-7502 BOYSEN PERMACOAT SEMIGLOSS LATEX WINTER MORNING
(Contd. of page 4)
· 10.3 Possibility of hazardous reactions No dangerous reactions known.
· 10.4 Conditions to avoid No further relevant information available.
· 10.5 Incompatible materials: No further relevant information available.
· 10.6 Hazardous decomposition products: No dangerous decomposition products known.
SECTION 11: Toxicological information
· 11.1 Information on toxicological effects
· Acute toxicity Based on available data, the classification criteria are not met.
· LD/LC50 values relevant for classification:
330-54-1 diuron(ISO)
Oral LD50 4150 mg/kg (rat)
Dermal LD50 >5000 mg/kg (rat)
Inhalative LC50/4 h >1 mg/l (rat)
· Primary irritant effect:
· Skin corrosion/irritation Based on available data, the classification criteria are not met.
· Serious eye damage/irritation Based on available data, the classification criteria are not met.
· Respiratory or skin sensitisation Based on available data, the classification criteria are not met.
· CMR effects (carcinogenity, mutagenicity and toxicity for reproduction)
· Germ cell mutagenicity Based on available data, the classification criteria are not met.
· Carcinogenicity Based on available data, the classification criteria are not met.
· Reproductive toxicity Based on available data, the classification criteria are not met.
· STOT-single exposure Based on available data, the classification criteria are not met.
· STOT-repeated exposure Based on available data, the classification criteria are not met.
· Aspiration hazard Based on available data, the classification criteria are not met.
SECTION 12: Ecological information
· 12.1 Toxicity
· Aquatic toxicity:
330-54-1 diuron(ISO)
EC50/ 48 7.4 mg/l (bluegill sunfish)
1.4 mg/l (daphnia magna)
EC50/ 72h 25 mg/l (poecilia reticulata)
EC50/96 h 5.9 mg/l (bluegill sunfish)
0.022 mg/l (scenedesmus)
14.7 mg/l (oncorhynchus mykiss)
25 mg/l (poecilia reticulata)
14.7 mg/l (rainbow trout)
LC50/ 48 h 3.2 mg/l (cyprinus carpio)
1.4 mg/l (daphnia magna)
7.4 mg/l (lepomis macrochirus)
· 12.2 Persistence and degradability No further relevant information available.
· 12.3 Bioaccumulative potential No further relevant information available.
· 12.4 Mobility in soil No further relevant information available.
· Ecotoxical effects:
· Remark: Harmful to fish
(Contd. on page 6)
PH
49.0
Page 6/7
Safety Data Sheet
according to GHS
Printing date 18.08.2020 Version number 12 Revision: 27.11.2019
Trade name: B-7502 BOYSEN PERMACOAT SEMIGLOSS LATEX WINTER MORNING
(Contd. of page 5)
· Additional ecological information:
· General notes:
Water hazard class 1 (German Regulation) (Self-assessment): slightly hazardous for water
Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system.
Harmful to aquatic organisms
· 12.5 Results of PBT and vPvB assessment
· PBT: Not applicable.
· vPvB: Not applicable.
· 12.6 Other adverse effects No further relevant information available.
SECTION 13: Disposal considerations
· 13.1 Waste treatment methods
· Recommendation
Must not be disposed together with household garbage. Do not allow product to reach sewage system.
· Uncleaned packaging:
· Recommendation: Disposal must be made according to official regulations.
· Recommended cleansing agents: Water, if necessary together with cleansing agents.
SECTION 14: Transport information
· 14.1 UN-Number
· ADR, ADN, IMDG, IATA Not regulated
· 14.2 UN proper shipping name
· ADR, ADN, IMDG, IATA Not regulated
· 14.3 Transport hazard class(es)
· ADR, ADN, IMDG, IATA
· Class Not regulated
· 14.4 Packing group
· ADR, IMDG, IATA Not regulated
· 14.5 Environmental hazards:
· Marine pollutant: No
· 14.6 Special precautions for user Not applicable.
· 14.7 Transport in bulk according to Annex II of
Marpol and the IBC Code Not applicable.
· UN "Model Regulation": Not regulated
* SECTION 15: Regulatory information
· 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
· Philippines Inventory of Chemicals and Chemical Substances
All ingredients are listed.
· Directive 2012/18/EU
· Named dangerous substances - ANNEX I None of the ingredients is listed.
(Contd. on page 7)
PH
49.0
Page 7/7
Safety Data Sheet
according to GHS
Printing date 18.08.2020 Version number 12 Revision: 27.11.2019
Trade name: B-7502 BOYSEN PERMACOAT SEMIGLOSS LATEX WINTER MORNING
(Contd. of page 6)
· 15.2 Chemical safety assessment: A Chemical Safety Assessment has not been carried out.
* SECTION 16: Other information
This information is based on our present knowledge. However, this shall not constitute a guarantee for any
specific product features and shall not establish a legally valid contractual relationship.
· Relevant phrases
H303 May be harmful if swallowed.
H331 Toxic if inhaled.
H333 May be harmful if inhaled.
· Department issuing SDS:
Product Safety:
[email protected] · Abbreviations and acronyms:
ADR: Accord européen sur le transport des marchandises dangereuses par Route (European Agreement concerning the International
Carriage of Dangerous Goods by Road)
IMDG: International Maritime Code for Dangerous Goods
IATA: International Air Transport Association
GHS: Globally Harmonised System of Classification and Labelling of Chemicals
EINECS: European Inventory of Existing Commercial Chemical Substances
ELINCS: European List of Notified Chemical Substances
CAS: Chemical Abstracts Service (division of the American Chemical Society)
VOC: Volatile Organic Compounds (USA, EU)
LC50: Lethal concentration, 50 percent
LD50: Lethal dose, 50 percent
PBT: Persistent, Bioaccumulative and Toxic
vPvB: very Persistent and very Bioaccumulative
Acute Tox. 5: Acute toxicity – Category 5
· * Data compared to the previous version altered.
04.07.2015
PH
49.0