SANJIVANI PRATISTHAN MUMBAI SANCHALIT
S. P. I. T. POLYTECHNIC, KURUND
At- Kurund, Post- Ralegan Therpal, Tal- Parner, Dist - Ahmednagar, Pin- 414306
Phone - (02488) 212631 ,292839 Email-spitkurund@[Link]
(Approved by AICTE, New Delhi, recognized by Govt. of Maharashtra & affilited to MSBTE, Mumbai)
Department of Mechanical Engineering
Fluid Mechanics & Machinery Lab
Apparatus No. 1 – Bernoulli’s Theorem
1. Motor Capacity – ½ Hp
2. Measuring Tank – 0.3 × 0.4 m = 0.12 m2
3. No. of Tubes – 9 Nos
4. Area of Cross Section – (From left) 5, 4, 3.5, 2.5, 3.5, 3.45, 4, 4.75, 5
cm2 respectively.
SANJIVANI PRATISTHAN MUMBAI SANCHALIT
S. P. I. T. POLYTECHNIC, KURUND
At- Kurund, Post- Ralegan Therpal, Tal- Parner, Dist - Ahmednagar, Pin- 414306
Phone - (02488) 212631 ,292839 Email-spitkurund@[Link]
(Approved by AICTE, New Delhi, recognized by Govt. of Maharashtra & affilited to MSBTE, Mumbai)
Department of Mechanical Engineering
Fluid Mechanics & Machinery Lab
Apparatus No. 3 – Major Losses in Pipes
1. Motor Capacity – ½ Hp
2. Measuring Tank – 0.3 × 0.4 m = 0.12 m2
3. Diameter of First Pipe (d1) – 0.029m,
4. Diameter of Second Pipe (d2) – 0.019m,
5. Diameter of Third Pipe (d3) – 0.012m,
6. Length of tapping – 1m,
7. Specific Gravity of Manometric Fluid – 13.6
SANJIVANI PRATISTHAN MUMBAI SANCHALIT
S. P. I. T. POLYTECHNIC, KURUND
At- Kurund, Post- Ralegan Therpal, Tal- Parner, Dist - Ahmednagar, Pin- 414306
Phone - (02488) 212631 ,292839 Email-spitkurund@[Link]
(Approved by AICTE, New Delhi, recognized by Govt. of Maharashtra & affilited to MSBTE, Mumbai)
Department of Mechanical Engineering
Fluid Mechanics & Machinery Lab
Apparatus No. 2-A – Venturi Meter
1. Motor Capacity – ½ Hp
2. Measuring Tank – 0.3 × 0.4 m = 0.12 m2
3. Diameter of Inlet Pipe (d1) – 0.025m,
4. Diameter of Throat (d2) – 0.012m,
5. Manometric Fluid – Mercury
6. Specific Gravity of Manometric Fluid – 13.6
Apparatus No. 2-B – Orifice Meter
1. Motor Capacity – ½ Hp
2. Measuring Tank – 0.3 × 0.4 m = 0.12 m2
3. Shape of Orifice – Circular
4. Diameter of Inlet Pipe (d1) – 0.025m,
5. Diameter of Throat (d2) – 0.012m,
6. Manometric Fluid – Mercury
7. Specific Gravity of Manometric Fluid – 13.6
SANJIVANI PRATISTHAN MUMBAI SANCHALIT
S. P. I. T. POLYTECHNIC, KURUND
At- Kurund, Post- Ralegan Therpal, Tal- Parner, Dist - Ahmednagar, Pin- 414306
Phone - (02488) 212631 ,292839 Email-spitkurund@[Link]
(Approved by AICTE, New Delhi, recognized by Govt. of Maharashtra & affilited to MSBTE, Mumbai)
Department of Mechanical Engineering
Fluid Mechanics & Machinery Lab
Apparatus No. 4 – Minor Losses in Pipes
1. Motor Capacity – ½ Hp
2. Measuring Tank – 0.3 × 0.4 m = 0.12 m2
3. For sudden Enlargement
a. Diameter of pipe at Entry, d1 – 12 mm
b. Diameter of pipe at Exit, d2 – 25mm
4. For Sudden Contraction
a. Diameter of pipe at Entry, d3 – 25mm
b. Diameter of pipe at Exit, d4 – 12mm
5. Bend of 900 , Diameter of Pipe, d5 – 12mm
6. Diameter of pipe at Elbow, d6 – 12mm
D3 – 25mm
Sudden Contraction
Sudden Expansion
Elbow 90o
D6 – 12mm D1 – 12mm D4 – 12mm
D2 – 25mm
D5 – 12mm
To Measuring
Tank
From motor
Bend 90o
SANJIVANI PRATISTHAN MUMBAI SANCHALIT
S. P. I. T. POLYTECHNIC, KURUND
At- Kurund, Post- Ralegan Therpal, Tal- Parner, Dist - Ahmednagar, Pin- 414306
Phone - (02488) 212631 ,292839 Email-spitkurund@[Link]
(Approved by AICTE, New Delhi, recognized by Govt. of Maharashtra & affilited to MSBTE, Mumbai)
Department of Mechanical Engineering
Fluid Mechanics & Machinery Lab
Apparatus No. 5 A – Pelton Wheel Turbine
1. Motor Capacity – 5 Hp
2. Diameter of Brake Drum – 0.308m
3. Circumference of Brake Drum – 0.967m
4. Diameter of rope on brake drum – 0.02m
5. Equivalent drum diameter – 0.328m
6. Diameter of throat of venturimeter – 0.0305m
7. Inlet pipe diameter of Venturimeter – 0.0508m
8. Coefficient of Discharge of Venturimeter – 0.64
9. No. of Buckets – 18
10. Jet Diameter – 14mm
11. Angle of outlet tip – 250
Department of Mechanical Engineering
Fluid Mechanics & Machinery Lab
Apparatus No. 5 B – Burdon & U tube Manometer
1. Motor Capacity – 5 Hp
2. Pipe diameter – 0.0508m
3. Burdon Gauge Scale – 0 04 kg/cm2
SANJIVANI PRATISTHAN MUMBAI SANCHALIT
S. P. I. T. POLYTECHNIC, KURUND
At- Kurund, Post- Ralegan Therpal, Tal- Parner, Dist - Ahmednagar, Pin- 414306
Phone - (02488) 212631 ,292839 Email-spitkurund@[Link]
(Approved by AICTE, New Delhi, recognized by Govt. of Maharashtra & affilited to MSBTE, Mumbai)
Department of Mechanical Engineering
Fluid Mechanics & Machinery Lab
Apparatus No. 6 – Centrifugal Pump
1. Motor Capacity – 3 Hp
2. Measuring Tank – 0.3 × 0.3 m = 0.09 m2
3. Efficiency of Electric Motor – 74 %,
4. Type of drive used from motor to pump – Belt Drive,
5. Diameter of Suction pipe – 0.050m,
6. Type of Impeller – Closed
7. Speed of Pump – 1440 rpm
SANJIVANI PRATISTHAN MUMBAI SANCHALIT
S. P. I. T. POLYTECHNIC, KURUND
At- Kurund, Post- Ralegan Therpal, Tal- Parner, Dist - Ahmednagar, Pin- 414306
Phone - (02488) 212631 ,292839 Email-spitkurund@[Link]
(Approved by AICTE, New Delhi, recognized by Govt. of Maharashtra & affilited to MSBTE, Mumbai)
Department of Mechanical Engineering
Fluid Mechanics & Machinery Lab
Apparatus No. 7 –Reciprocating Pump
1. Suction Pipe Diameter, D1 – 0.022m
2. Delivery Pipe Daimeter – 0.022m
3. Diameter of Cylinder bore – 0.0445m,
4. Length of stroke, L – 0.035m,
5. Measuring Tank – 0.3 × 0.4 m = 0.12 m2
6. Constant of electric energy meter – 3200 imp/ Kwh
7. Speed of Pump – 1440 rpm