ABOUT CHINT

CHINT A leading global provider of smart energy solutions

Main Businesses

Low-voltage Power Transmission and Instrumentation Intelligent


Clean Energy Apparatus Distribution and Apparatus Smart Home
Building

Intelligent Industry Home Electrical


Smart Heating Smart Water Apparatus
Manufacturing Automation
ABOUT CHINT LOW VOLTAGE

Zhejiang CHINT Electrics Co., Ltd. is a wholly owned subsidiary of CHINT Group. Cultivating R&D, manufacturing and sales of low-voltage
products, we provide system solutions for building, power supply, hoisting, HVAC, telecommunication and other industrial customers. For
nearly 40 years since its founding, CHINT Electrics has provided reliable products and services to over 140 countries and regions. Today,
CHINT has grown to be one of the world’s renowned low-voltage brands.

CHINT Honors

CHINT was selected in the 2020 Zhejiang Province "Future Factory"


"Global Partnership" and "Countries along the Belt and Road" in the "2021 Best recognized list, and was rated as the leading " Leading Goose Factory".
Practices for Realizing the Sustainable Development Goals". The key inverter technology of CHINT won the second prize of China
CSR Impact Leading Enterprise Electric Power Science and Technology.
CHINT Astrometry was selected as the smart PV demonstration enterprise
list of the Ministry of Industry and Information Technology and won the

No. 1 in " China's Top 100 Private Enterprises with Social Responsibility" in 2021
For 8 consecutive years, CHINT has won the sales champion of Tmall double
11 in electrical and hardware industry
No. 92 in "2021 China's Top 500 Private Enterprises“.
No. 244 in "2021 Top 500 Chinese Enterprises" National Green Factory
The intelligent manufacturing factory of low-voltage electrical appliances was National Industrial Design Center of the MIIT
selected as the national "2021 Intelligent Manufacturing Demonstration Global Top 20 PV Enterprise
Factory". China’s Top 10 Successful PV Enterprise
Top 100 Innovative Enterprises in Zhejiang Province
Technology innovation system was awarded the 2018 Science and Technol-
ogy Progress Award in Zhejiang

Qualification Certification
GLOBAL FOOTPRINT

Netherlands
Germany Poland
捷克
The Czech
Frankfurt Republic
Kazakhstan
Italy Romania
i North America
Spain Europe Turkey
U.S.A.
Xianyang Jinan
Cairo Yancheng Los Angeles
Algeria
Egypt Hangzhou Shanghai
Jiaxing Mexico
U.A.E. Wenzhou

India Asia P
Western Asia and Africa Thailand
Cambodia Vietnam
Malaysia
Colombia
Singapore
Indonesia
R&D center
Peru
Latin America
International marketing territory

Manufacturing base Brazil


Chile

4 North Africa 6 and Africa, Europe, Latin America, North America, China

14 Manufacturing Bases: China (Wenzhou, Hangzhou, Shanghai, Jiaxing, Xianyang, Jinan, Yancheng), Thailand, Singapore, Vietnam, Malaysia, Egypt,
Algeria and Cambodia

20+ International Logistics Centers


2300+ Sales Companies

GLOBAL CAPACITY LAYOUT


The industrial manufacturing bases are mainly located in Wenzhou, Hangzhou, Shanghai, Jiaxiang, Xianyang and Yancheng. Additionally, CHINT has set up
factories in Thailand, Singapore, Vietnam, Malaysia, Egypt, Cambodia etc.

Wenzhou Manufacturing Base Hangzhou Manufacturing Base Shanghai Manufacturing Base Jiaxing Manufacturing Base Xianyang Manufacturing Base

Yancheng New Energy Singapore Complete Electric


Jinan Cable Manufacturing Base Wuhan Manufacturing Base Vietnam Manufacturing Base
Manufacturing Base Equipment Manufacturing Base

Thailand Solar Power


Malaysia Manufacturing Base Egypt Manufacturing Base Algerian Manufacturing Base Cambodia Manufacturing Base
Manufacturing Base
R&D, QUALITY, SALES, LOGISTICS

Main Advantages
Global R&D System

The average annual R&D investment


24 research institutes Over 6000 patents in total
accounts for 4-12% of the revenue

EK
RT
TE
IN

Honors
No. 1 in China's Top 100 Private Enterprises with Social Responsibility in 2021
No. 92 in 2021 China's Top 500 Private Enterprises
No. 244 in 2021 Top 500 Chinese Enterprises
The intelligent manufacturing factory of low-voltage electrical appliances was selected as the national 2021 Intelligent Manufacturing
Demonstration Factory

Integrated Vertical R&D Great Quality System One-stop Ser vices 48-Hour Response

By gathering the global industry ������ Providing end-to-end one-stop


elites to Provide safe and stable services for customers with complains,
energy-saving green and advanced business consulting and technical
electric products. support by solving problems immedi-
ately and including any possible
problems in advance.

At least 5% of revenue is
invested in research and
development
NM8N Moulded Case Circuit Breaker

Body

Thermo magnetic release

Electronic release

Communication module

Battery box

Cable connector

Front connection plate

Rear connection plate

Cage clamp terminal

Residual current protection module

Long terminal cover

Short terminal cover

Direct rotary handle

Economic extended rotary handle

Extended rotary handle

Motor driven operating mechanism

Mechanical interlock

Locking system

Closing electromagnet

Under-voltage release

Shunt release

Alarm contact

Auxiliary contact

Interphase barrier

Plug-in base

Draw-out base

DIN rail adaptor

Plug and pull safety device


Contents

1. General ...................................................................................................................... 01

2. Operating conditions ................................................................................................... 01

3. Type designation ......................................................................................................... 02

4. Technical data.............................................................................................................. 04

5. Release........................................................................................................................ 10

6. Tripping curve .............................................................................................................. 13

7. Mounting of circuit breaker............................................................................................ 20

8. Overall and Mounting Dimensions ............................................................................... 21

9. Accessories characteristics and installation .................................................................... 49

10. Technical Supplement ................................................................................................ 71

11. Ordering notice ......................................................................................................... 80


P- 001

1. General
NM8N series moulded case circuit breaker is suitable for the circuit of AC 50/60Hz, with rated voltage
AC690V and below, DC system rated voltage DC1000V and below, and rated current of 16A and
1600A. It can protect circuits and electric equipment against overload, short circuit or undervoltage, and
can also provide protection of overload, short circuit and under voltage for infrequent start of motor.

Products have functions of power distribution protection, motor protection, residual current protection
and isolation. B
The circuit breaker can be installed vertically, installed horizontally and can also
enter the line from the bottom.

Standards compliant:
IEC 60947-1 general rules for low-voltage switchgear and control equipment;
IEC 60947-2 low-voltage switchgear and control equipment circuit breakers;
IEC 60947-3 low-voltage switchgear and control equipment switches,
disconnectors and fuse combination appliances;
IEC 60947-4-1 Electromechanical contactors and motor starters (including motor protectors) for low
voltage switchgear and control equipment.

2. Operating conditions
2.1 Temperature:
Operating and storage temperature is -40°C~+70°C; the average value within 24 hours does not
exceed +35°C; when the ambient temperature is -40°C~+70°C, users need to consider derating or
temperature compensation whose details can be referred to in Page.
2.2 Altitude: ≤ 2000m;

2.3 Pollution grade: Grade 3;

2.4 IP grade: IP40

2.5 Air conditions:


At mounting site, relative humidity not exceed 50% at the max temperature of +40°C, higher relative
humidity is allowable under lower temperature. For example, RH could be 90% at +20°C, special
measures should be taken to occurrence of dews.
P- 002

3. Type designation
3.1 NM8N Moulded Case Circuit Breaker and Switch Disconnector
NM8N

Special application

Poles:
1P: 1-pole
2P: 2-pole
3P: 3-pole
4B: 4-pole, there is no over-current protection at
pole N and N-pole operates with other three poles
4C: 4-pole, there is over-current protection at pole N
and N-pole operates with other three poles

Rated current
125 : 16-20-25-32-40-50-63-80-100-125
250 : 32-63-100-125-160-180-200-225-250
400 : 250-315-350-400
630 : 400-500-630
800 : 500-630-700-800
1600 : 800-1000-1250-1600

Release type code


TM: Thermal-magnetic type
EN: Basic electronic type for power distribution
EM: Standard electronic type for power distribution
M: Magnetic type for motor protection
ENM: Basic electronic type for motor protection
EMM: Standard electronic type for motor protection
Blank:Switch disconnector type

Breaking capacity code: B, C, S, Q, H, R


(Switch disconnector type has no code)

Frame size rated current:


125:125A;250:250A;400:400A
630:630A;800:800A;1600:1600A

DC: DC MCCB
Blank: AC MCCB
SD: Switch disconnector

Design code

Design sequence number

MCCB

Company code
P- 003

3.2 NM8NL Residual Current Breaker


NM8NL

B
Rated residual current code:
RCD1: 0.03-0.1-0.3-1A adjustable
(Applicable to the frame size of 125-250-400-630)
RCD2: 0.05-0.2-0.5-2A adjustable (Applicable to the
frame size of 125-250)
RCD3: 0.05-0.2-0.5-1A adjustable (Applicable to the
frame size of 400-630)
RCD4: 0.1-0.3-1-2A adjustable (Applicable to the
frame size of 400-630)

Rated residual current type:


Default: AC type, A: A type

Pole code:
3P: 3-pole
4P: 4-pole
Frame size rated current:
125:125A;250:250A;400:400A;630:630A
Residual current code

Design code

Design sequence number


MCCB

Company code
P- 004

4. Technical data
NM8N Moulded Case Circuit Breaker 125 250
Magnetic type 16-20-25-32-40-50-63-80-100-125 125-160-180-200-225-250
Rated operating
Thermal-magnetic type 16-20-25-32-40-50-63-80-100-125 125-160-180-200-225-250
current In (A),40℃
Electronic type — 32-63-100-160-250
Electric characteristics
Rated insulation voltage Ui (V) 1000 1000
Rated impulse withstand voltage (kV) 8 8

Rated operational voltage Ue(V),AC 50/60Hz 380/400/415,440,500,660/690 380/400/415,440,500,660/690

Breaking capacity code C S Q H R C S Q H R


1P ■ ■ — — — ■ ■ — — —
2P ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Number of poles
3P ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
4P ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
AC220/230/240V1) 36 50 — — — 36 50 — — —
AC380/400/415V 36 50 70 100 150 36 50 70 100 150
Rated ultimate
short-circuit breaking AC440V 36 50 70 100 100 36 50 70 100 100
capacity Icu (kA)
AC500V 25 40 40 50 50 25 40 40 50 50
AC660/690V 6 8 8 10 10 6 8 8 10 10
AC220/230/240V1) 36 50 — — — 36 50 — — —
AC380/400/415V 36 50 70 100 150 36 50 70 100 150
Rated service breaking
AC440V 36 50 70 100 100 36 50 70 100 100
capacity Ics (kA)
AC500V 25 40 40 50 50 25 40 40 50 50
AC660/690V 6 8 8 10 10 6 8 8 10 10
Rated short-time withstand current Icw (kA,1s) — 1(32A,63A);2(100A,160A);3(250A)
Standard IEC/EN 60947-2

Utilization category A A

Ambient temperature -40℃ ~+70℃ 2)


Safety of insulation ■ ■
Arcing distance 0 0
Mechanical life
Maintenance 25000 25000
(CO recycle)
Electrical life AC415V,In 10000 10000
(CO recycle) AC690V,In 2000 1500
Release units
TM ■ ■
Distribution protection EN — ■
EM — ■
M ■ ■
Motor protection ENM — ■
EMM — ■
Mounting and connection
Front connection ■ ■
Fixed
Rear connection ■ ■
Front connection ■ ■
Plug-in3)
Rear connection ■ ■

3)
Front connection — —
Draw-out
Rear connection — —
DIN rail Front connection ■ ■
Dimension
Width (1P/2P/3P/4P) 35/62/90/120 10/70/105/140
Dimension (mm)
Height 140 157
W×H×D
Depth 78.5 88.7
Weight
1P 0.5 0.75
2P 0.83 1.3
Weight(kg)/Fixed
3P 1.19 1.85(EM/M) ; 2.0(EN/EM)
4P 1.55 2.5(TM/M) ; 2.65(EN/EM)
1)
Note : For 1 pole product only;
2)
The operating temperature of basic (dial code) electronic type is -35℃ ~+70℃ ,and the operating temperature
of standard (liquid crystal) electronic type is -25℃ ~+70℃ ;
3)
For 3/4 pole product only;
4)
The data in "()" is for motor type.
P- 005

400 630 800 1600


250-315-350-400 400-500 500-630-700-800 —
250-315-350-400 400-500 500-630-700-800 800-1000-1250-1600
250-400 400-630 630-800 800-1000-1250-1600

1000
12
1000
12
1000
12
1000
8
B
380/400/415,440,
380/400/415,440,500,600/690 380/400/415,440,500,660/690 380/400/415,440,500,660/690
500,660/690
C S Q H R C S Q H R C S Q H R S Q H
— — — — — — — — — — — — — — — — — —
— — — — — — — — — — — — — — — — — —
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
— — — — — — — — — — — — — — — — — —
36 50 70 100 150 36 50 70 100 150 36 50 70 100 150 50 70 100
36 50 70 100 100 36 50 70 100 100 36 50 70 100 100 50 65 65
25 40 40 50 50 25 40 40 50 50 25 40 40 50 100 40 50 50
10 12 12 15 15 10 12 12 15 15 12 15 15 20 30 30 30 30
— — — — — — — — — — — — — — — — — —
36 50 70 100 150 36 50 70 100 150 36 50 70 100 150 50 70 70
36 50 70 100 100 36 50 70 100 100 36 50 70 100 100 40 50 50
25 40 40 50 50 25 40 40 50 50 25 40 40 50 100 30 40 40
10 12 12 15 15 10 12 12 15 15 12 15 15 15 15 30 30 30
5 5(400A);8(630A) 10 20
IEC/EN 60947-2
A(Thermal-magnetic)/
A(Thermal-magnetic)/B(Electronic) A(Thermal-magnetic)/B(Electronic) A(Thermal-magnetic)/B(Electronic)
B(Electronic)
2)
-40℃ ~+70℃
■ ■ ■ ■
0 0 0 0

20000 20000 20000 10000

8000 8000 8000 3000


1500 1500 1000 1000

■ ■ ■ ■
■ ■ ■ ■
■ ■ ■ ■
■ ■ ■ ■
■ ■ ■ —
■ ■ ■ —

■ ■ — ■
■ ■ ■ —
■ ■ — —
■ ■ — —
■ ■ ■ —
■ ■ ■ —
— — — —

140/185 140/185 195/260 210/280


255 255 300 286
113 113 133 167(195)4)

— — — —
— — — —
5.2(TM/M) ; 6.7(EN/EM) 5.5(TM/M) ; 7.0(EN/EM) 10.5(TM/M) ; 10.5(EN/EM) 13.5(16)4)
5.8(TM/M) ; 7.8(EN/EM) 5.8(TM/M) ; 7.8(EN/EM) 13.5(TM/M) ; 13.5(EN/EM) 17.5(20)4)
P- 006

NM8N DC Moulded Case Circuit Breaker 125 250

Rated operating current In (A),40℃ 16-20-25-32-40-50-63-80-100-125 125-160-180-200-225-250

Electric characteristics

Rated insulation voltage Ui (V) 1000 1000

Rated impulse withstand voltage Uimp (kV) 8 8

Rated operational voltage Ue (V),DC 250 , 500 , 750 , 1000 250 , 500 , 750 , 1000

Breaking capacity code B C S Q H B C S Q H

1P ■ ■ ■ — — ■ ■ ■ — —

2P ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Number of poles
3P ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

4P ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

DC250V 1P 25 36 50 — — 25 36 50 — —
Rated ultimate DC500V 2P in series 25 36 50 70 100 25 36 50 70 100
short-circuit breaking
capacity Icu(kA) DC750V 3P in series 25 36 50 70 100 25 36 50 70 100

DC1000V 4P in series 25 36 50 70 100 25 36 50 70 100

DC250V 1P 25 36 50 — — 25 36 50 — —

Rated service breaking DC500V 2P in series 25 36 50 70 100 25 36 50 70 100


capacity Ics(kA) DC750V 3P in series 25 36 50 70 100 25 36 50 70 100

DC1000V 4P in series 25 36 50 70 100 25 36 50 70 100

Standard IEC/EN 60947-2

Utilization category A A

Ambient temperature -40℃ ~+70℃

Safety of insulation ■ ■

Arcing distance 0 0
Mechanical life
Maintenance free 15000 15000
(CO recycle)
Electrical life
DC1000V,In 2000 1500
(CO recycle)
Release units

Distribution protection TM ■ ■

Mounting and connection

Front connection ■ ■
Fixed
Rear connection ■ ■

Front connection ■ ■
Plug-in1)
Rear connection ■ ■

Front connection — —
Draw-out1)
Rear connection — —

DIN rail Front connection ■ ■

Dimension

Width(1P/2P/3P/4P) 35/62/90/120 40/70/105/140


Dimension(mm)
Height 140 157
W×H×D
Depth 78.5 88.7

Weight

1P 0.5 0.75

2P 0.83 1.3
Weight(kg)/Fixed
3P 1.19 1.85

4P 1.55 2.5
1)
Note : For 3/4 pole product only.
P- 007

400 630 800 1600


8 0 0 -10 0 0 -
250-315-350-400 400-500 500-630-700-800 1250-
1600

B
1000 1000 1250 1000

12 12 12 8

750 , 1000 750 , 1000 750 , 1000 750 , 1000

B C S Q H B C S Q H B C S Q H B C

— — — — — — — — — — — — — — — — —

— — — — — — — — — — — — — — — — —
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

— — — — — — — — — — — — — — — — —

— — — — — — — — — — — — — — — — —

25 36 50 70 100 25 36 50 70 100 25 36 50 70 100 25 36

25 36 50 70 100 25 36 50 70 100 25 36 50 70 100 25 36

— — — — — — — — — — — — — — — — —

— — — — — — — — — — — — — — — — —

25 36 50 70 100 25 36 50 70 100 25 36 50 70 100 25 36

25 36 50 70 100 25 36 50 70 100 25 36 50 70 100 25 36

IEC/EN 60947-2

A A A A

-40℃ ~+70℃
■ ■ ■ ■

0 0 0 0

15000 15000 10000 6000

1500 1500 1000 1000

■ ■ ■ ■

■ ■ — ■

■ ■ ■ —
■ ■ — —
■ ■ — —
■ ■ ■ —
■ ■ ■ —

— — — —

140/185 140/185 195/260 210/280

255 255 300 286

113 113 133 167

— — — —

— — — —

5.2 5.5 10.3 13.5

6.7 7 13.5 17.5


P- 008

NM8NL Residual Current protection module 125 250 400 630

Rated operating current In (A), 40℃ 125 250 400 630

Number of poles 3P、4P 3P、4P 3P、4P 3P、4P

Electric characteristics

Rated insulation voltage Ui (V) 1000 1000 1000 1000

Rated insulation voltage Uimp (kV) 8 8 12 12

Rated operational voltage Ue(V),AC 50/60Hz 380/400/415、440 380/400/415、440 380/400/415、440 380/400/415、440


16-20-25-32-40-50-63- 125-160-180-200-225-
TM 250-315-350-400A 400-500A
80-100-125 250
EN — 32-63-100-160-250 250-400 400-630

Rated current (A) EM — 32-63-100-160-250 250-400 400-630


of circuit breaker 16-20-25-32-40-50-63- 125-160-180-200-225-
M 250-315-350-400A 400-500A
80-100-125 250
ENM — 32-63-100-160-250 250-400 400-630

EMM — 32-63-100-160-250 250-400 400-630


RCD1 ( Four-step
0.03-0.1-0.3-1 0.03-0.1-0.3-1 0.03-0.1-0.3-1 0.03-0.1-0.3-1
adjusable )
RCD2 ( Four-step
0.05-0.2-0.5-2 0.05-0.2-0.5-2 — —
Rated residual operating adjusable )
current I △ n(A) RCD3 ( Four-step
— — 0.05-0.2-0.5-1 0.05-0.2-0.5-1
adjusable )
RCD4 ( Four-step
— — 0.1-0.3-1-2 0.1-0.3-1-2
adjusable )
Rated residual non-operating current I △ no(A) 0.5I △ n 0.5I △ n 0.5I △ n 0.5I △ n
1)
Limit non-actuating time (ms) △ t : 0-60-200-500
Maximum breaking Total breaking time
100-300-500-1000 100-300-500-1000 100-300-500-1000 100-300-500-1000
time (ms) (adjustable)
Rated residual making and breaking capacity
0.25Icu 0.25Icu 0.25Icu 0.25Icu
I △ m(kA)
Leakage alarm non-tripping function □ □ □ □

Standard IEC/EN 60947-2

Residual current type A/AC A/AC A/AC A/AC

Safety of insulation ■ ■ ■ ■

Ambient temperature -25℃ ~+70℃

Arcing distance 0 0 0 0

Dimension

Width ( 3P/4P ) 90/120 105/140 140/185 140/185


Dimension with circuit
breaker (mm) Height 205 232 355 355
W×H×D
Depth 78.5 88 113 113

Weight

Weight of residual current 3P 0.43 0.84 1.98 1.98


protection module (kg) 4P 0.51 1.08 2.69 2.68

Note : 1) When the residual operating current is set to 0.03A, the limit non-actuating time must be set to 0.
P- 009

NM8NSD Switch Disconnector 125 250 400 800 1600


NM8NSD Switch Disconnector
125 250 400 800 1600
Ith(A),40℃
Number of poles 2P 3P 4P 2P 3P 4P 3P 4P 3P 4P 3P 4P
800-1000-1250-
Rated operational current Ie(A) 125 250 400 800
1600

Rated operational
voltage Ue(V)
AC (50/60Hz)

DC
690

500 750 1000


690

500 750 1000


690

750 1000
690

750 1000
415/690

750 1500 B
AC : 1000
Rated insulation voltage Ui(V) 1000 1000 1000 1250
DC : 1500
Rated impulse withstand
8 8 12 12 12
voltage Uimp(kV)
Rated short-circuit making capacity
3.2(AC)/2(DC) 5(AC)/3.2(DC) 8(AC)/5(DC) 14 40(AC)/19.2(DC)
Icm(kA)
Rated short-time 1s 2 3.2 5 8/10 20(AC)/19.2(DC)
withstand current
Icw(kA) 3s 2 3.2 5 8/10 20

Standard IEC/EN 60947-3, GB/T 14048.3


AC-22A/AC-23A AC-22A/AC-23A AC-22A/AC-23A AC-22A/AC-23A AC-22A/AC-23A
Utilization category
DC-22A/DC-23A DC-22A/DC-23A DC-22A/DC-23A DC-22A/DC-23A DC-22A/DC-23A
Safety of insulation ■ ■ ■ ■ ■

Ambient temperature -40℃ ~+70℃

Arcing distance 0 0 0 0 0
Mechanical life
Maintenance free 15000 15000 15000 10000 6000
(CO recycle)
AC415V,In 8000 6000 4000 2000 1000
Electrical life
AC690V,In 2000 1500 1500 1000 1000
(CO recycle)
DC1000V,In 2000 1500 1500 1000 1000

Mounting and connection

Front connection ■ ■ ■ — ■
Fixed
Rear connection ■ ■ ■ ■ ■

Front connection ■ ■ ■ — —
Plug-in1)
Rear connection ■ ■ ■ — —

Front connection — — ■ ■ —
Draw-out1)
Rear connection — — ■ ■ —

DIN rail Front connection ■ ■ — — —

Dimension

Width(2P/3P/4P) 62/90/120 70/105/140 140/185 195/260 210/280


Dimension(mm)
Height 140 157 255 300 286
W×H×D
Depth 78.5 88.7 113 133 167(195)2)

Weight

2P 0.81 1.1 — — —

Weight(kg)/Fixed 3P 1.05 1.75 5 9.5 13(15.5)2)

4P 1.5 2.4 5.5 12.5 17(19.5)2)

Note : 1) For 3/4 pole product only;


2)
The data in "()" is for motor type.
P- 010

5. Release
5.1 Protection for power distribution
5.1.1 Thermo-magnetic type release TM
Thermo-magnetic release of NM8N-125, 250, 400, 630, 800 and 1600 breakers can be set to meet
protection requirements

In In

Thermo-magnetic
125 250 400 630 800 1600
release TM
2P/3P
Number of poles 1P 1P 2P/3P/4P 3P/4P 3P/4P 3P/4P 3P/4P
4P
16/20/25 125/160 180
125 250/315 500/630 800/1000
Rated current 32/40/50 180/200 200/225 400/500
160 350/400 700/800 1250/1600
63/80/100/125 225/250 250
Over-load protection
1.0 0.7- 1.0
Setting current 0.7-0.8-
Non- 0.8- Non- 0.7-0.8-0.9-1.0
( A ) Ir=Inx 0.9-1.0
adjustable 0.9-1.0 adjustable
Short-circuit instantaneous protection
7-8-
Setting current
10 10 9-10- 5-6-7-8-9-10 6-7-8-9-10
( A ) Ii=Inx
11-12
Accuracy ±20%
N-pole protection
Setting current
/ 10 / The same with the other three-phase poles.
( A ) IiN=Inx
Accuracy ±20%

5.1.2 Basic electronic type release for power distribution EN


EN electronic trip unit has three-stage protection of overload, short circuit short time-delay and short
circuit instantaneous protection.

Electronic type EN 250 400 630 800 1600


Over-load Setting current Ir=Inx 0.4-0.5-0.6-0.7-0.8-0.9-0.95-1.0
long-time delay
protection 6Ir Tripping time Tr(s) 3-6-12-18, Accuracy ±10%

Short circuit Setting current Isd=Ir x 1.5-2-3-4-6-8-10, OFF, Accuracy ±15%


short-time delay 0.1-0.2-0.3-0.4, Accuracy ±20% or ±40ms(higher value will
protection Tripping time Tsd(s)
be selected)
Short circuit Setting current Ii=Inx 2-3-4-6-8-10-12, OFF, Accuracy ±15%
instantaneous
protection Max. tripping time (ms) 60
IrN=(0.5,1)xIn, OFF; I sdN=(1.5-2-3-4-6-8-10)IrN
Neutral line Setting current
IiN=(2-3-4-6-8-10-12)IrN
protection
Tripping time (s) The same with the other three-phase poles.

● Overload protection and tripping time setting


—The current value Ir can be adjusted according to the user's needs. The tripping time Tr is at the
status of 6Ir.
● Short circuit short-time delay protection and trip time setting
—The current value Isd can be adjusted according to the user's needs. Tripping time Tsd is the
shortcircuit short time-delay tripping time, which can be adjusted according to user needs.
● Short circuit instantaneous protection characteristics setting
—The current value Ii can be adjusted according to the user's needs.
● Neutral line protection feature setting
The four-pole circuit breaker N-pole protection current value can be adjusted according to user
needs. The N pole tripping time is the same with the other three-phase poles.

5.1.3 Standard electronic type release for power distribution EM


EM release has four-stage protection of overload, short circuit short-time delay, short circuit
instantaneous protection and earth fault, with real-time current display, protection parameter.
P- 011

information display, fault information display and oarameter setting function

Electronic type EM 250 400 630 800 1600


Over-load Setting current Ir=Inx 0.4~1.0, Stepping1A
long-time delay
protection 6Ir Tripping time Tr(s) 3~18, 1s, Accuracy ±10%

Short circuit Setting current Isd=Ir x 1.5~10, Stepping1A, OFF, Accuracy ±15%

B
short-time delay 0.1-0.2-0.3-0.4, Accuracy ±20% or ±40ms(higher value will
protection Tripping time Tsd(s)
be selected)
Short circuit Setting current Ii=Inx 1.5~12, Stepping1A, OFF, Accuracy ±15%
instantaneous
protection Max. tripping time (ms) 60

Earth fault Setting current I g=Inx 0.4-0.5-0.6-0.7-0.8-0.9-1.0, OFF, Accuracy ±15%


protection Tripping time (s) 0.1-0.2-0.3-0.4, Accuracy ±15%

Neutral line Setting current IrN=(0.5,1)xIn; I sdN=(1.5~10)IrN; IiN=(1.5~12)IrN, able to turn OFF
protection Tripping time (s) The same with the other three-phase poles.

● Overload protection and tripping time setting


— Current setting value Ir, the user can adjust the range according to the ↑ and ↓ buttons on
the panel, the range is (0.4~1.0) In, and the tripping time Tr is at the status of 6Ir, which can be
adjusted according to user needs.
● Short circuit short-time delay protection and tripping time setting
—The current setting value Isd can be adjusted according to the user's needs, and the “OFF”
indicates function can be turned off. Tripping time Tsd is the short-circuit short-time delay tripping
time, which can be adjusted according to user needs.
● Short circuit instantaneous protection characteristics setting
—The current setting value Ii can be adjusted according to the user's needs, and the “OFF”
indicates function can be turned off.
● Neutral line protection feature setting
—Neutral line protection of the four-pole circuit breaker (current setting value InN ), the setting
range is 0.5In, 1I n or OFF, which can be adjusted according to the user's needs. The “OFF”
position indicates that the N pole has no protection function.
● Earth fault protection
Earth fault Ig can be adjusted according to user needs, where the “OFF” means the function can be
turned off.

5.2 Protection for motor


td 5.2.1 Motor starting characteristics
At present, most of the motors use three-phase asynchronous induction motors, and a large part
of them use the direct start mode, namely, the electric energy does not take artificial restriction
measures, and directly feeds to start the motor, which is also called full-pressure start. When the
asynchronous motor is directly started, a high starting current of 4 to 7 times of the rated current
n d d
occurs. The reason why the asynchronous motor has a large starting current is that the motor
has certain inertia, and the rotor speed cannot be immediately changed to the rated speed after
Motor starting Current curve starting. At this time, the relative rotational speed of the rotating magnetic field of the stator
(synchronous speed of the motor, slightly higher than the rated speed) is large. The rotor winding
cuts the stator magnetic field at a large speed to generate a large current; at the same time, the
magnetic field generated by the large current of the rotor in turn induces the stator winding, so that
the current also rapidly increases.
Startup parameter
Rated current (In ): current value of the motor under rated operation
Starting current (Id): The current when the motor starts, its magnitude varies with different
conditions, the average value is 7.2×In
Start peak current (Id): Transient current during the first two half-waves after the motor is powered
on, typically 14 × In
Start-up time (td): generally 0.5~20s, which refers to the time when the motor has starting current
Direct startup impact on the protection device
For circuit breakers with magnetic protection, if the conventional current of the magnetic trip unit is
set incorrectly, the circuit breaker will mistake the start current of the motor for short-circuit current,
causing the circuit breaker to malfunction. For the independent thermal relay, the heat generated
by the large starting current during the motor starting phase will also cause the relay to trip. For
the contactor, if the motor needs electric or regenerative braking, it needs to be able to be broken
during the motor starting phase. It generally needs to derate, in order to avoid the malfunction
of the protection device caused by the start current:The inverse time characteristic curve of the
independent thermal relay is required to be completely
above the starting current.
The short-circuit current trip setting of the circuit breaker with magnetic protection should be
greater than the peak starting current of the motor.

5.2.2 Protection solution


The NM8N Series offers start-up, control and protection solutions for two three-phase
asynchronous motors:
P- 012

Three-component solution
Electromagnetic protection circuit breaker + contactor + thermal relay
Among them, the electromagnetic protection circuit breaker is used for short circuit protection,
the contactor is used for motor operation, and the thermal relay is used for overload, phase loss
andphase unbalance protection.
1)Magnetic release M
The electromagnetic protection circuit breaker has a current range of 125~800A, an adjustable
range of 9~14In and an accuracy of 20%. It is especially suitable for use in the classic
threecomponent protection solution.

Ii
Ii

Magnetic M 125 250 400 630 800


Pole 3P/4P 3P/4P 3P/4P 3P/4P 3P/4P
Short circuit instantaneous protection
Setting current ( A ) Ii=Inx 12 9-10-11-12-13-14
Accuracy ±20%
N pole protection
Setting current ( A ) IiN=Inx 12 The same with the other three-phase poles.Ii
Accuracy ±20%
Two-component solution
Integrated protection electronic circuit breaker + contactor
In the two-component solution, there is no need to use the thermal relay, and the integrated
protection electronic circuit breaker has the functions of overload, phase loss, phase unbalance
protection and short circuit protection. The integrated protection electronic circuit breaker not only
has high tripping precision, but also has reliable operation. The two-component solution consisting of
contactors and the installation time can be saved without being affected by the ambient temperature.
2)Integrated protection: Basic electronic type release for motor protection ENM
The ENM electronic trip unit allows for tighter tolerance trip times, as detailed in the table below.
Electronic type ENM 250 400 630 800
Setting current Ir=Inx 0.4-0.5-0.6-0.7-0.8-0.9-1.0, OFF
Overload
long-time delay 4、8、16,
7.2Ir Tripping time Ir(s) 4、8、16、24, Accuracy ±15%
protection Accuracy ±10%
Tripping level 5、10、20 5、10、20、30
Short circuit Setting current I sd=Ir x 5-6-8-9-10-11-12, OFF, Accuracy ±15%
short-time delay
protection Tripping time Tsd(ms) 100, Accuracy ±40
Short circuit Setting current Ir=Inx 151)
instantaneous
protection Max. trpping time (ms) 60
Phase unbalance/Phase failure I unbal 30%-40%-50%-60%-70%-80%-90% (Phase failure)-OFF
Max. trip time of phase imbalance (s) 4-6-8-10, Accuracy ±20%
Tripping time of phase failure (s) 0.25, Accuracy ±20%
IrN=(0.5,1)xIn;I sdN=(5-6-8-9-10-11-12)IrN
Neutral line Setting current
IiN=15IrN, OFF
protection
Tripping time The same with the other three-phase poles
Note: 1)Setting current Isd<Ii (within tolerance).
3)Integrated protection: Standard electronic type release for motor protection EMM
The EMM electronic release not only has the protection function of the ENM release, but also adds
ground fault protection and stall protection. Moreover, it can also display real-time current, display
protection parameter information, display fault information, and have parameter setting function.
Electronic type EMM 250 400 630 800
Protection current Ir=Inx 0.4~1.0, Stepping , OFF
Overload
4、8、16,
long-time delay 7.2Ir Tripping time Tr(s) 4、8、16、24, Accuracy ±10%
Accuracy ±10%
protection
Tripping level 5、10、20 5、10、20、30
Short circuit Setting current I sd=Ir x 4~12, Stepping1A , OFF, Accuracy ±15%
short-time delay
protection Tripping time Tsd(ms) 100, Accuracy ±40
Short circuit Protection current Ir=Inx 151)
instantaneous
protection Max. trpping time (ms) 60
Protection current I g=Inx 0.4-0.5-0.6-0.7-0.8-0.9-1.0 , OFF, Accuracy ±15%
Earth falt
protection 0.1-0.2-0.3-0.4, Accuracy ±20% or 40ms(higher
Tripping time (s)
value will be selected)
Phase unbalance/Phase failure Iunbal 30%-40%-50%-60%-70%-80%-90% (Phase failure)-OFF
Max. trip time of phase imbalance (s) 4-6-8-10, Accuracy ±10%
Tripping time of phase failure (s) 0.25, Accuracy ±20%
Locked-rotor current Ijam (3~10)Ir , Stepping1A, OFF(Defalut), Accuracy ±15%
Tripping time T jam (s) 1~30, Step size1s, Defalut 5, Accuracy ±10%
Neutral line Setting current IrN=(0.5,1)xIn, OFF;I sdN=(4~12)IrN;IiN=15IrN, OFF
protection Tripping time The same with the other three-phase poles
Note: 1)Setting current Isd<Ii (within tolerance).
P- 013

6. Tripping curve
6.1 Thermal-magnetic type for power distribution

NM8N-125(16A,20A,25A,32A)

t (s) 10000

B
7200
3600
2000

1000
500

200
100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01
.005

.002
.001
.5 .7 1 2 3 4 6 8 1012 20 30 50 70 100 200 300 400 600 1200 Xlr

NM8N-125(40A,50A,63A)
t (s) 10000
7200
3600
2000

1000
500

200
100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01
.005

.002
.001
.5 .7 1 2 3 4 6 8 1012 20 30 50 70 100 200 300 400 600 1200 Xlr

NM8N-125(80A,100A,125A)
t (s) 10000
7200
3600
2000

1000
500

200
100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01
.005

.002
.001
.5 .7 1 2 3 4 6 8 1012 20 30 50 70 100 200 300 400 600 1200 Xlr
P- 014

NM8N-250(125A,160A)

t (s) 10000
7200
3600
2000

1000
500

200
100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01
.005

.002
.001

.5 .7 1 2 3 5.6 6 8 10 14.4 20 30 50 70 100 200 300 400 600 1200 Xlr

NM8N-250(180A)

t (s) 10000
7200
3600
2000

1000
500

200
100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01
.005

.002
.001

.5 .7 1 2 3 4 6 8 1012 20 30 50 70 100 200 300 400 600 1200 Xlr

NM8N-250(200A,225A,250A)
t (s) 10000
7200
3600
2000

1000
500

200
100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01
.005

.002
.001

.5 .7 1 2 3 4 6 8 1012 20 30 50 70 100 200 300 400 600 1200 Xlr


P- 015

NM8N-400(250A~400A)

t (s) 10000
7200
3600
2000

1000

B
500

200
100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01
.005

.002
.001

.5 .7 1 2 3 4 6 8 1012 20 30 50 70 100 200 300 400 600 1200 Xlr

NM8N-630(400A~500A)

t (s) 10000
7200
3600
2000

1000
500

200
100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01
.005

.002
.001

.5 .7 1 2 3 4 6 8 1012 20 30 50 70 100 200 300 400 600 1200 Xlr

NM8N-800(500A~800A)

t (s) 10000
7200
3600
2000

1000
500

200
100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01
.005

.002
.001

.5 .7 1 2 3 4 6 8 1012 20 30 50 70 100 200 300 400 600 1200 Xlr


P- 016

NM8N-1600(800A~1600A)

t (s) 10000
7200
3600
2000

1000
500

200
100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01

.005

.002
.001
.5 .7 1 2 3 4 6 8 1012 20 30 50 70 100 200 300 400 600 1200 Xlr

6.2 Magnetic type for motor protection

NM8N-125(16A~125A)

t (s) 10000
7200
3600
2000

1000
500
Maximum heat withstand capacity
200
100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01
.005

.002
.001
.5 .7 1 2 3 4 6 89.614.4 20 30 50 70 100 200 300 400 600 1200 Xln

NM8N-250(125A~250A)

t (s) 10000
7200
3600
2000

1000
500

200 Maximum heat withstand capacity


100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01
.005

.002
.001
.5 .7 1 2 3 4 6 7.2 16.8 20 30 50 70 100 200 300 400 600 1200 Xln
P- 017

NM8N-400(250A~400A)

t (s) 10000
7200
3600
2000

1000
Maximum heat withstand capacity

B
500

200
100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01
.005

.002
.001
.5 .7 1 2 3 4 6 7.2 16.8 20 30 50 70 100 200 300 400 600 1200 Xl r

NM8N-630(400A~500A)

t (s) 10000
7200
3600
2000

1000
500 Maximum heat withstand capacity

200
100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01
.005

.002
.001
.5 .7 1 2 3 4 6 7.2 16.8 20 30 50 70 100 200 300 400 600 1200 Xln

NM8N-800(500A~800A)

t (s) 10000
7200
3600
2000

1000 Maximum heat withstand capacity


500

200
100
50

20

10
5

2
1
.5

.2
.1
.05

.02

.01
.005

.002
.001
.5 .7 1 2 3 4 6 7.2 16.8 20 30 50 70 100 200 300 400 600 1200 Xln
P- 018

6.3 Electronic type for power distribution

EN Basic electronic type

10000 10000
Long-time Ir =(0.4,0.5,0.7,0.8,0.9,0.95,1)In Instantaneous li =(OFF,2,3,4,6,8,10,12In)
t(s) delay Tr =(3,6,12,18)s t(s)

Short-time Isd =(OFF,1.5,2,3,4,6,8,10Ir )


1000 1000
delay Tsd =(0.1,0.2,0.3,0.4)s

100 100

10 10
18s
12s

6s

1 3s 1

0.4s
0.3s
0.2s

0.1 0.1s 0.1 50ms

0.01 0.01
10ms

0.001 0.001
0.5 1 1.5 5 10 l/lr 1 2 10 12 l/ln

EM Standard electronic type

10000 10000 10000

t(s) Long-time delay Ir =(0.4~1)In Tr =(3~18)s Instantaneous li =(1.5~12)In t(s)


t(s) Earth fault Ig=(0.4~1)I n Tg =(0.1~0.4)s
Short-time
Isd=(1.5~10)I Tsd =(0.1~0.4)s
delay
1000 1000 1000

100 100 100

10 10 10

1 1 1 0.4s
0.3s
0.2s
0.4s
0.3s
0.1s
0.2s
0.1 0.1
0.1s 0.1 50ms

0.01 0.01 0.01

10ms

0.001 0.001 0.001


0.5 1 1.5 5 10 l/lr 1 2 10 12 l/ln 0.1 0.4 1 l/ln
P- 019

6.4 Electronic type for motor protection

ENM Basic electronic type

B
10000 10000
Long-time Ir =(OFF,0.4,0.5,0.7,0.8,0.9,1)In @7.2Ir Instantaneous li =15In
t(s) delay Class=(5,10,20,30) t(s)

Short-time Isd =(OFF,5,6,8,9,10,11,12 )Ir


1000 delay Tsd =0.1s 1000

100 100

10 Class30 10
Class20

Class10

Class5
1 1

0.1 0.1s 0.1 50ms

0.01 0.01
10ms

0.001 0.001
0.5 1 1.5 5 l/lr 1 10 15 l/ln

EMM Standard electronic type

10000 10000 10000


Instantaneous li =15In Earth fault Ig=(0.4~1)In Tg =(0.1~0.4)s
Long-time Ir =(0. 4~1)In @7.2lr
t(s) delay Class=(5,10,20,30) t(s) t(s)

Short-time
1000 delay I sd=(4~10)Ir Tsd =0.1s 1000 1000

100 100 100

10 Class30 10 10
Class20

Class10

Class5 0.4s
1 1 1 0.3s
0.2s

0.1s

0.1 0.1s 0.1 50ms 0.1

0.01 0.01 0.01


10ms

0.001 0.001 0.001


0.5 1 1.5 5 10 l/lr 1 2 10 15 l/ln 0.1 0.4 1 l/ln
P- 020

7. Mounting of circuit breaker


7.1 Modes of down-lead

LINE LOAD

LINE

LOAD LINE

Incoming method

7.2 Modes of mounting

OK
OK

Modes of mounting OK

OK
7.3 Safe distance

Zero arc

Unit (mm)
P- 021

8. Overall and Mounting Dimensions


8.1 NM8N-125
NM8N-125 Front connection

108.5
78.5
B
72
62.5
35 27.5
19
25.5
18

29

27.5 4

2*M8
54.5
140
125

112
112

X X X
98

2xΦ3.2
Φ3.2
2XM8 2XM6
18 1P
Front connecting plate 26.5 4
15 1P
Y
27.5

25
54.5

4XM8
Front connecting plate

Phase barrier

Unit (mm)
P- 022

NM8N-125 Front connection (3P/4P)


108.5
78.5
90 120 72
30 30 30 30 62.5

27.5 4
19
50

50
25.5
25.5
18

18

27.5
25
49

49

54.5
140
125
112
140
125
112

98
98

4xM8 6XM6 8x M8 8XM6


18
Front connection 26.5 4
15 15
Phase barrier

3P 4P

30 60
15 15
112

112

2xΦ5.5 4xΦ5.5

Unit (mm)
3P 4P

NM8N-125 Rear connection (1P/2P)


29 30
14.5 4xΦ5.5 4xΦ15
A A
47 10
Φ6.2
M6
12.5

1P
125

125
112

112
125

47
2xΦ6.2
2xΦ5.5
12.5

30

2xΦ3.2
9
3.5

87 10 1P 2P
2P
Unit (mm)
P- 023

NM8N-125 Rear connection (3P/4P)

A A 6xΦ15 60 8xΦ15
30
47 10 4xΦ6.2

B
N极
M6

30
125
140

112
112
12.5

125
112
30
30
2xΦ5.5 4xΦ5.5 15
3.5

87 10

78.5 30 30 30 30 30
108.5
Rear connerction
3P 4P

Unit (mm)

NM8N-125 Plug-in front connection

66.8
A
16 24 10.5 122(min)
Φ8.3 92(min)
60
A 15 15

40.2
152.6(min)

152.6(min)
170.4
178.4

170.4
140

156

193

78.5
108.5 2xΦ5.5 4xΦ5.5
15 30 15
Mounting plate
Φ8.3

3P 4P

Unit (mm)

NM8N-125 Plug-in rear connection

92.6
85.3
122(min)
40.2
92(min) 60
24 10.5 15 15
28.5

Φ8.3
30.6(min)

30.6(min)

46(min) 46(min)
16

60 Φ6 30 60 Φ6
Vertical conneciton
62.5

30 30
96.9(max)

96.9(max)
30.8(min)

30.8(min)
170.4

170.4
156
26.9
140

65

65

6 6
56

12

12
28.5
3

30.6(min)
30.(min)

78.5
108.5 Horizontal connection 2xΦ5.5 4xΦ5.5
30 15
Mounting plate

3P 4P

Unit (mm)
P- 024

NM8N-125 DIN-rail mounting

29 30 60
14.5 15 15 15

112

112

112

112
2xΦ3.2 2xΦ5.5 2xΦ5.5 4xΦ5.5

1P 2P 3P 4P

Unit (mm)

NM8N-125 DIN-rail mounting (DIN-rail adapter is needed)

9
35

35
140

140
18

18

3P 4P

Unit (mm)

NM8N-125 Mechanical interlock

90 90 120 120

60 60
120 150

3P 4P
Unit (mm)
P- 025

NM8N-125 Terminal cover

248
90 64.5
45
120 66
78.5

3P Long terminal cover 4P Long terminal cover


161.5

45
90 64.5
120
66
78.5

3P Short terminal cover 4P Short terminal cover

Unit (mm)
P- 026

8.2 NM8N-250
NM8N-250 Front connection (1P/2P)

125.2
95.5
88.7
82.5
73
40 72.5
32.5 5
22.5
39.1
30.7

2XM8 2xΦ3.5

2xΦ3.1
34

27
55

60
75
157
140
119
110

119
25.2

34

2xΦ8.5
34
20.5
Front connection 20 32 5
1P

125.2
95.5
88
70 82
73
35

32.5 5
108

2xΦ5.2 22.5
30.7
40

4XM8 2xΦ5.5
34.4

27
55

75.3
60
157
140
125
110

125

125

4xΦ8.5
20.5
Front connection 20 32 5

Phase barrier Unit (mm)

NM8N-250 Front connection (3P/4P)

105 125.2
90 95.5
70 140
88
50 105 82
35 35 73

20 32.5 5

6xΦ8.5
22.5 35 70
30.7
39.1

6xM8 17.5
17.5 4xΦ5.5
8xM8 2xΦ5.5
34.4
34.4

2xΦ5.5

27
75.3
75.3

60
60

125

125
157
140
125
110

20.5

3P 4P
32 5
Front connection
108

Phase barrier

Unit (mm)
P- 027

NM8N-250 Rear connection (1P/2P)

A
A
125.2 2xΦ18 34
31.5
Φ8.2 4xΦ18 35
88

6
2xΦ3.5 2xΦ5.5
B

18
45

1P
85
157

140
140

125
119
140
Φ8.2

35
18
45
71.5
2P

1P 2P

Unit (mm)

NM8N-250 Rear connection (3P/4P)

A
70
125.2 A 35 17.5
88 31.5 6xΦ19 8xΦ19
85 10
6

N极
Φ8.2 2xΦ5.5 4xΦ5.5
157

140

140
125
35
18

45 10
71.5 35 35 35 35
Rear connection

3P 4P

Unit (mm)

NM8N-250 Plug-in front connection

75.1
51.7
26.8
12.1
125.2 2xΦ6.5
A
88 4xΦ6.5

45.1
169(min)

169(min)
189.6

189.6
216.2
38.5

198.6
175.2
169
157

17.5

35
18 Mounting plate
35
10

4 70
105(min) 140(min)

3P 4P

Unit (mm)
P- 028

NM8N-250 Plug-in rear connection

102.4
93.6
75.1

32.5(min)

32.5(min)
125.2 45.1 105(min) 140(min)
88 26.8 12.1 2xΦ6.4 4xΦ6.4
Φ8.3

17.5 52.5 17.5

18
R3 R3
69.3 6 17.5 Φ6 6 17.5 Φ6

110.5(max)

110.5(max)
38.5(min)

38.5(min)
175.2
110.5
157

38.5

189.6

189.6
75

75
62.5

70 35 70
4

Horizontal connection 17.5


Mounting plate 35 17.5

32.5(min)

32.5(min)
3P 4P

Unit (mm)

NM8N-250 DIN-rail mounting

2xΦ3.5 2xΦ5.5 2xΦ5.5 4xΦ5.5

17.5
119

125

125

125

75

34
35 35 70

1P 2P 3P 4P

Unit (mm)

NM8N-250 DIN-rail mounting (DIN-rail adapter is needed)

9
4.5

4.5
35

157

157
35

3P 4P
Unit (mm)
P- 029

NM8N-250 Mechanical interlock

B
58

58
69.9 73.2
139.8 174.8

3P 4P Unit (mm)

NM8N-250 Terminal cover

186.4

105 52.5 76.5


140
88

3P Short terminal cover 4P Short terminal cover


361

52.5 76.5
105 88
140

3P Long terminal cover 4P Long terminal cover Unit (mm)


P- 030

8.3 NM8N-400/630
NM8N-400/630 Front connection
140 171
185
106 113
151
45 96
45
A ≤400A 500A/630A
mm 27 28

A 8
39.4

6xM10
25

8xM10

201

201
255

201
227

4xΦ6

45 6xΦ6
4xΦ5.5 45
110.6

90

Front connection 30
6xΦ13.1 Phase barrier
3P 4P

76
Unit (mm)

NM8N-400/630 Rear connection

171
113 A
8

51.7 R15

Φ12.5
8xΦ32
30

201
227
227

201
227
90
45 6xΦ6
45

4xΦ6
N极

111.2 6xΦ32
90 45
90
Rear connection

3P 4P
A

Unit (mm)

NM8N-400/630 Plug-in front connection


171
113 69.2
23.5 24.2 185(min)
A
140(min)

77
271.5(min)

271.5(min)
277.5
255

313
342

300

300

4xΦ6.5 6xΦ6.5
45 45
30.2 Mounting plate 6
Φ11 90

3P 4P
Unit (mm)
P- 031

NM8N-400/630 Plug-in rear connection

171 127.1

23.5 24.2 Φ11


14.5

B
113 140(min) 185(min)
90
45 4xΦ6.5 6xΦ6.5
45

46(min)

46(min)
Vertical connection

30.2
Φ6

113.5
Φ6
100 100

185.6(max)

185.6(max)
37.2 38

37.2 38
277.5
255

150

150
300

300
145
103.8

R3 6 R3 6
6

Horizontal connection
Φ6.3

Mounting plate 3P 4P
Unit (mm)

NM8N-400/630 DIN-rail mounting

45 45 45
22.5 22.5

U
201

4xΦ5.5 4xΦ5.5

3P 4P

Unit (mm)

NM8N-400/630 Mechanical interlock

185 185
140 140 140 140

93.5 116.3
187 232.5

3P 4P

Unit (mm)
P- 032

NM8N-400/630 Long terminal cover

480.5

90.5
140 185 113
157 202

3P 4P Unit (mm)

NM8N-400/630 Short terminal cover


286.6

70 99
140
185 113

3P 4P

Unit (mm)
P- 033

NM8N-400/630 Draw-out type

227
L6 L5
d1
Front connection
Rera connection

L6
L7

L3

L1
L2
L4

H3

H4
H5
H6
H1 W1 W1
W2 Unit (mm)

Dimension
Current Pole
L1 L2 L3 L4 L5 L6 L7 H1 H3 H4 H5 H6 W1 W2 d1
3P 342 313 207 312 30 6 143 280 77 21 35.5 17.5 45 214 11
In≤400A
4P 342 313 207 312 30 6 143 280 77 21 35.5 17.5 45 259 11
3P 342.5 314.5 210.5 313.5 30 8 143 280 77.5 21.5 35.5 17.5 45 214 11
In>400A
4P 342.5 314.5 210.5 313.5 30 8 143 280 77.5 21.5 35.5 17.5 45 259 11

DIN-rail mounting

A d2

installation dimension
Pole
A B d2
3P 90 143 6.5
B

4P 135 143 6.5

DIN-rail mounting

Rear connection
W4
L7

Installation floor
L8

L9

d2

Front connection
W5

W4

Installation floor

Installation dimension of rear plate connection


Current
L8 W5 L9 L7 W4 d3 Pole
143 90 181 70 138 7 3P
In≤400A
143 135 181 70 182 7 4P
144.5 90 182.5 70 138 7 3P
In>400A
144.5 135 182.5 70 182 7 4P
L7=90 when it is front connection, the rest of dimensions are the same with rear connection
P- 034

8.4 NM8N-800
NM8N-800 Front connection (3P)
112.5

65

6xM12

4xΦ6.5

6xΦ6.5
235
265
300

235

111
65 113
193
130
195

Unit (mm)
P- 035

NM8N-800 Front connection (4P)

32.5
B
112.5

8xM12 65 65

6xΦ6.5
6xΦ6.5

235
235
265
300

65 111
130 133
195 193
260

Unit (mm)

NM8N-800 Rear connection

130(3P)
A A 65
193
133 118.5
20 8xΦ45
8

M12 N pole
265
235
300

265

40

Φ12 6xΦ7

43.5 130
195(4P)

3P/4P
Unit (mm)
P- 036

NM8N-800 Mechanical interlock

135.5
135.5
269
269
3P 4P

Unit (mm)

NM8N-800 Short terminal cover

330.6

97.5
195 113
260

3P Short terminal cover 4P Short terminal cover

Unit (mm)
P- 037

NM8N-800 Long terminal cover

B
516.6

516.6

195 113
97.5
260 113.5

3P Long terminal cover 4P Long terminal cover

Unit (mm)
P- 038

NM8N-800 Draw-out type


212.5
L6 L10 d1
Front connection

Rear connection

L6

L8
L5
L4
H3 L3
H4

W1 W1
H1 H5 W2 Unit (mm)

Dimension
Pole
L3 L4 L5 L6 L8 L10 H1 H3 H4 H5 W1 W2 d1
3P 275 445 485 10 141 40 270 61 42.5 62.5 65 281 13
4P 275 445 485 10 141 40 270 61 42.5 62.5 65 346 13

DIN-rail mounting

A d2

installation dimension
Pole
A B d2
≥32

3P 130 141 7
B

4P 195 141 7

Rear connection

W4
L7

L7

Installation floor
L8

L9
L7

d3
L7

Front connection

W5
L7

W4

Installation floor

Installation dimension
Pole
L8 W5 L9 L7 W4 d3
3P 141 130 177 95 200 7
4P 141 195 177 95 265 7
L7

L7=200 when it is front connection, the rest of dimensions


are the same with rear connection
P- 039

8.5 NM8N-1600
NM8N-1600 Front connection (Manual type 3P)

239

B
191
167
263
126
210
186
70
50
A
32 70
30

35
38

4xΦ5.5

4xΦ5.5
578
392

247
286
258
247

12xM10

18xΦ11

Connevtion row In 800A,1000A,1250A 1600A


A 10mm 20mm

Unit (mm)

NM8N-1600 Front connection (Manual type 4P)

239
191
333 167
280
140 126
84.5

A
32
140
30

35 4xΦ5.5
38

6xΦ5.5
247
578
392
286
258
247

16xM10

24xΦ11

Connevtion row In 800A,1000A,1250A 1600A


A 10mm 20mm

Unit (mm)
P- 040

NM8N-1600 Front connection (Motor type 3P)

195
171
126
263
210
186
70 A
50 32
70
30

35
38

4xΦ5.5

4xΦ5.5
286

247
578
392

258

247
12xΦM10

18xΦ11

Connection row In 800A,1000A,1250A 1600A


A 10mm 20mm

Unit (mm)

NM8N-1600 Front connection (Motor type 4P)

333
280
256
140 195
84.5 171
126

A
32
140
30

35
38

4xΦ5.5

6xΦ5.5
578
392
286
258
247

247

16xΦM10

24xΦ11

Connection row In 800A,1000A,1250A 1600A


A 10mm 20mm

Unit (mm)
P- 041

8.6 NM8NL
NM8NL-125 Front connection

120
90 90
60 60
30 30

6xΦ5.5 B
50

2xΦ5.5
25.5
18

6xΦM6
205
190
177

Connection row

15

108.5
78.5
72
62.5

27.5

30 60
19 15
177
177

2xΦ5.5 4xΦ5.5

19

27.5 4 3P 4P

Phase barrier
92

Unit (mm)
P- 042

NM8NL-125 Rear connection

30 60
A 15

M6 A
4xΦ6.2
N级

12.5
87 10
190

47 10

177
190

177
190
205

5
5.

5
5.
Φ

Φ
2x

4x
6xΦ14 8xΦ14
30 30 30
78.5
108.5 90

3P 4P

Unit (mm)

NM8NL-125 DIN-rail mounting

30
60
15
177

177

2xΦ5.5 4xΦ5.5

3P 4P

Unit (mm)
P- 043

NM8NL-250 Front connection

140
105 105
70 70 125.2
35 35 88

B
108

32.5 5

22.5
70
30.7

35
39

17.5 4xΦ5.5
3xΦ5.5

125
232
215
200

200

200
4xΦ5.5

8xM8
22.5

32.5 3P 4P
20 8xΦ8.5

73
101

Unit (mm)

NM8NL-250 Rear connection

105
70
35 70
A 35 17.5
Φ8.2 6xΦ20 8xΦ20

A
45 10
85 10 3xΦ5.5

N级
125
35

200

200
215

215
6
215

35
35

31.5
71.5
4xΦ5.5
18

88 23.5
125.2

3P 4P

Unit (mm)
P- 044

NM8NL-250 DIN-rail mounting

35 70
17.5 4xΦ5.5

125
200

200
3xΦ5.5

3P 4P

Unit (mm)

NM8NL-400/630 Front connection

140 185
Unit (mm)
106 151 171
106 90
45 113
45 96

A 8
90
22.5
39.4

45
25

4xΦ5.5 6xΦ5.5
301

301
355
327
301

6xΦ5.5

8xM10

30
110.6

8xΦ13.1 A 8 3P 4P

125

A ≤400A 500A,630A

mm 27 28
P- 045

NM8NL-400/630 Rear connection

135
90 90
45 45 22.5
A
6xΦ32 8xΦ32

8
A

B
111.2 4xΦ12.5

N级
327

301
30

327

301
327
355

51.7 15

4xΦ5.5 6xΦ5.5

113
171
3P 4P

Unit (mm)

NM8NL-400/630 DIN-rail mounting


90
45 22.5

4xΦ5.5 6xΦ5.5
301

301

3P 4P
Unit (mm)

8.7 NM8N Wiring diagram

NM8N-125 Cable connector

Unit (mm)

z
26
62.5

62.5
95

95

NM8N-125 Product center


NM8N-125 Product center
NM8N-125 Product center
Product center
MC21-M8 1hole CCT21-M8 1hole
P- 046

NM8N-250 Cable connector

z z

40
70

70
107.5

107.5
NM8N-250 Product center NM8N-250 Product center

NM8NL-250 Product center NM8NL-250 Product center

CCT22-M8 1hole MC22-M8 1hole


52

41
70
107.5
70
107.5

NM8N-250 Product center NM8N-250 Product center

NM8NL-250 Product center NM8NL-250 Product center Unit (mm)


MC22-M8 2hole MC22-M8 6hole

NM8N-630 Cable connector

Unit (mm)

z
z
73

z
56
113.5

113.5

113.5
163.5

163.5

163.5

NM8N-400/630 Product center NM8N-400/630 Product center NM8N-400/630 Product center

NM8NL-400/630 Product center NM8NL-400/630 Product center NM8NL-400/630 Product center

CCT23-M8 1hole MC23-M8 2hole MC23-M8 2hole


P- 047

NM8N-800 Cable connector

42
132.5
NM8N-800 Product center
MC24-M8 2hole
Unit (mm)

NM8N-1600 Cable connector

Unit (mm)

z z
85.5

85.5
129

129

NM8N-1600 Product center NM8N-1600 Product center

MC25-M8 4hole MC25-M8 3hole


P- 048

8.8 Wiring

NM8N-125 NM8N-250

≤4
≤6

≥ 7.5 Φ7
≤4 ≥ 9.5 Φ8.5 ≤4
≤ 7.5 Φ8.5
≤ 8.5
.2
≤ 14
4. 2 ≤ 25
≤1

Unit (mm)

NM8N-400/630 NM8N-800

≤8 ≤10

≤8
Φ10.5
≥ 15 Φ10.5 ≥ 20 Φ13 ≤10 Φ13

≤ 12.5 0 ≤ 16
≤3
≤ 30 ≤ 50 ≤ 50
Unit (mm)

NM8N-1600

≤ 20

≥ 14 Φ10.5
25
≤ 16

≤ 55
Unit (mm)
P- 049

9. Accessories characteristics and installation


NM8N moulded case circuit breaker has various accessory modules, which can be found in P84 for
more details
9.1 AX Auxiliary contact

B
9.1.1 Function
Remotely indicate the circuit breaker's making (on) or breaking / tripping (OFF) status,
connected to the auxiliary circuit of the circuit breaker.
9.1.2 Model description
AX 21- M8

Serial code:NM8N series

Frame size code:Auxiliary contacts are universal accessories


for each frame,with default as code 21

Auxiliary contact name code


9.1.3 Indication of circuit breaker status

Circuit breaker is at breaking status AX12 AX11


AX14
AX12 AX11
Circuit breaker is at making status
AX14

9.1.4 Electrical characteristics

Rated Rated current (A)


voltage (V) AC-15 DC-13
AC 110 5 —
AC 240 4 —
AC 415 2 —
DC 110 — 0.25
DC 220 — 0.25

9.1.5 Wiring diagram

AX11 QF Power supply


AX14
Making circuit

Breaking circuit
AX
P- 050

9.2 AL Alarm contact


9.2.1 Function
It is mainly used to provide a signal when the load of the circuit breaker is overloaded, short-circuited
or undervoltage, or tripped.
The reasons for the failure of the alarm signal are:
Over-load or short-circuit
Undervoltage trip
Residual current action trip
Manual free trip

9.2.2 Model description

AL 21- M8

Serial code:NM8N series

Frame size code:Alarm contacts are universal accessories


for each frame,with default as code 21

Alarm contact name code

9.2.3 Indication of circuit breaker status

Circuit breaker is at breaking AL12 AL11


or making status AL14
Circuit breaker is at free tripping AL12 AL11
status AL14

9.2.4 Electrical characteristics

Rated Rated current (A)


voltage (V) AC-15 DC-13
AC 110 5 —
AC 240 4 —
AC 415 2 —
DC 110 — 0.25
DC 220 — 0.25

9.2.5 Wiring diagram

AL11 QF
Power supply
TRIP AL14

Making circuit

Breaking or making AL12 Breaking circuit


P- 051

9.3 SHT Shunt release


9.3.1 Function
Shunt releases operate according to electrical signals, enabling remote control and automatic control
of circuit breakers. When the supply voltage When the voltageis equal to any voltage between 70%
and 110% of the rated control power supply voltage, the shunt release should enable the circulit

B
bresker to operate relisbly.
9.3.2 Model description

SHT 21- M8 AC48V

Rated voltage: AC48V/110V/220-240V/380-415V;


DC24V/110-120V/220V

Series code:NM8N series

Frame code: 21 for 125 frame; 22 for 250/400/630 frame;


24 for 800 frame; 25 for 1600 frame

Shunt release code

9.3.3 Electrical characteristics

Power consumption (W)


Frame size
AC48V AC110V AC220-240V AC380-415V DC24V DC220V

125A 2.2 2.2 2 2.5 2.5 2

250/400/630A 2.3 2.5 2.2 2.5 2.2 2.5

800A 2.3 2.5 2.2 2.5 2.2 2.5

1600A 110 195 480 560 230 160

9.3.3 Action characteristics


Can be powered for a long time. Response time: pulse type ≥ 220ms, ≤ 60ms

9.3.5 Wiring diagram

Note: When the rated control power supply voltage DC24V shunt release is used, the maximum
length of the copper wire (each of the two wires) must meet the following table:

Conductor cross-sectional area


1.5mm2 2.5mm2
Rated control
supply voltageUs(DC24V)
100%Us 150m 250m

85%Us 100m 160m


P- 052

9.4 UVT Under-voltage release


9.4.1 Function
Realize the under-voltage protection function of the circuit breaker, open the circuit breaker when the
power supply voltage is too low, and protect the electrical equipment.
When the supply voltage drops (even slowly) to 70% to 35% of the rated control supply voltaage,
the under voltage, the undervoltage trips, the breaker should open the circuit breaker reliably.
When the supply voltage is equal to or greater than 85% of the rated control supply voltage of the
undervoltage release, the circuit breaker should be guaranteed to close.
When the supply voltage is less than 35% of the rated control supply voltage of the undervoltage
release, the undervoltage release should prevent the circuit breaker.

9.4.2 Model description

UVT 21- M8 AC48V

Rated voltage: AC48V;AC110V;AC220-240V;AC380-415V;


DC24V;DC48V;DC110-120V;DC220V

Series code:NM8N series

Frame size code: 21 for 125 frame; 22 for 250/400/630 frame;


24 for 800 frame; 25 for 1600 frame

Under-voltage release code

9.4.3 Electrical characteristics

Power consumption (W)


Frame size
AC48V AC110V AC220-240V AC380-415V DC24V DC48V DC110-120V DC220V

125A 1.6 1.6 2 3 1.2 1.6 2 2.2

250/400/630A 1.5 1.5 2.2 3 0.8 1.5 2 2.5

800A 1.5 1.5 2.2 3 0.8 1.5 2 2.5

1600A 2.6 2.2 1.7 0.7 2.8 2.5 2.2 1.8

9.4.4 Wiring diagram

Under-voltage release
P- 053

9.5 MOD Motor-driven mechanism


9.5.1 Function
It is suitable for closing, opening and re-opening of circuit breakers at long distances as well as
automation applications.
A: Protection level: IP40

B
Reliable insulation;
With isolation function indication;
O (open), I (closed) and free trip 3 position indications;
Free circuit breaker trip;
Manually or automatically operated circuit breakers for closing and opening.
B: manul operation
Pull the "manul/auto" switch to the manul position and turn the operation handle to switch on and off
the circuit breaker.
C: automatic operation
Pull the "manul/auto" switch to the automatic position, and remotely press the "close or open" button
to switch on and off the circuit breaker.
D: Automatically switch on or off by pulse or self-holding signal control.
E: Only when the control voltage is ≥ 85% Un and ≤ 110% Un can the circuit breaker be reliably
switched on and off.

9.5.2 Model description

MOD 21- M8 AC110/DC110-120V

Rated voltage: AC110/DC110-120V;AC220-240V/DC220V;


AC380-415V;DC24V

Series code:NM8N series

Frame size code: 21 for 125 frame; 22 for 250 frame;


23 for 400/630 frame; 24 for 800 frame; 25 for 1600 frame

Motor-driven mechanism code

Note: The 1600 frame motor-driven mechanism is assembled in the factory and is suitable for
electronic circuit breakers and disconnectors according to the inside of the circuit breaker.

9.5.3 Electrical characteristics


P- 054

9.5.3 Electrical characteristics

Frame Operational Rated Life Power Action Making Breaking Minimum duration of
size Type operational voltage (CO recycle) consumption current duration duration ON(OFF) signal pulse

AC110V/DC110 ≥3
150
AC220-240V
150
125A MOD 21-M8 DC220V 10000 ≤500ms ≤500ms 300ms
150 ≥4
AC380-415V
100
DC24V

AC110V/DC110 ≥3
150
AC220-240V
150
250A MOD 22-M8 DC220V 10000 ≤500ms ≤500ms 300ms
150 ≥4
AC380-415V
100
DC24V

AC110V/DC110 ≥3
300
AC220-240V
300
400/630A MOD 23-M8 DC220V 8000 ≤1000ms ≤1000ms 300ms
300 ≥8
AC380-415V
190
DC24V

AC110V/DC110 ≥3
300
AC220-240V
300
800A MOD 24-M8 DC220V 4000 ≤1000ms ≤1000ms 300ms
300 ≥8
AC380-415V
190
DC24V

9.5.4 Wiring diagram

P1 P2 S1 S2 S4

supply
Uc ON OFF
P- 055

9.5.5 Installation dimension drawing

Overall and mounting dimension of MOD21-M8

90
4xΦ3.1 83 25 99 2.7

88
113

17

90 190.7
45 170

62
Motor-driven

73.5
88
mechanism center 18

Product center
140

90(3P) z
120(4P)

Overall dimension of MOD22-M8

98.5 104
31.75 99 2.7 90
16
Φ4.2
45.5

4xΦ3.2
88
69
P- 056

Mounting dimension of MOD22-M8

105 201
90 179
45

57.5
73.5
Motor-driven
mechanism center

88
13.5
Product center

105(3P)
140(4P) z

Overall and mounting dimension of MOD23-M8

45 17 132 5 130
4xΦ4.2
202

23
2xΦ3.5
60

45
131

262
130
65 226
90

Motor-driven
120

mechanism center
140
20
255

Product center

140(3P) z
185(4P)
P- 057

Overall and mounting dimension of MOD24-M8

23.5 132 5 130


183

4xΦ4.5
B

140
115.5

17.5

281.5
130 245.5
65

100.5
Motor-driven 120
mechanism center
140
30.5
300

Product center

195 z
260
P- 058

9.6 SRH Economic extended rotary handle


9.6.1 Function
The unique design and transmission structure are adopted to realize the closing, opening and re-
closing operation of the circuit breaker by rotating the handle.
Protection degree: IP30
With isolation funtion indication;
O (open), I (closed) and free trip 3 position indications;
The circuit breaker can be locked in the OFF position with 1~3 padlocks with a diameter of
5~8mm. At this time, it can prevent the circuit breaker from closing and the swith cabinet from
opening;
When the switch is in the ON position, the cabinet door cannot be opened under the action of
the rotary handle (if the cabinet door is opened urgently, the cabinet door can be opened by the
emergency unlocking device on the handle).

9.6.2 Model description

SRH 21- M8 3P

Number of poles: 3P; 4P (only applicable to 125, 250 frames);400A and


above frames have no code

Series code:NM8N series

Frame size code: 21 for 125 frame; 22 for 250 frame;


23 for 400/630 frame; 24 for 800 frame; 25 for 1600 frame

Economic extended rotary handle code

Note: default length of shaft is 150mm

9.6.3 Installation dimension drawing

Overall and mounting dimension of SRH21-M8


P- 059

Overall and mounting dimension of SRH22-M8

137
105(3P)
112(4P) 52.5
18
47

M
B

65
24
Min=50mm

Φ65
105(3P)
140(4P) 54
Φ36

45°
Hinge

2xΦ5.5

≥200

Overall and mounting dimension of SRH23-M8

140
70 180

18

47
M
126

24

140(3P) Φ65 Min=50mm

185(4P)

54
Φ36
45°

Hinge

2xΦ5.5

≥200
P- 060

Overall and mounting dimension of SRH24-M8

195 186
63

47
M
3.5

Product center
Handle center

19

126
24
Min=50mm
Φ65
195(3P)
260(4P) 54
Φ36

45°
Hinge

2xΦ5.5

≥200

Overall and mounting dimension of SRH25-M8

210 225
60

15

52
M
Product center
28.5

Handle center
170

29
210(3P)
Min=50
280(4P) 150

112 4xΦ4.2

Φ36
150

112

≥200
P- 061

9.7 DRH Direct rotary handle


9.7.1 Function
The unique design and transmission structure are adopted to realize the closing, opening and re-
closing operation of the circuit breaker by rotating the handle.
Protection degree: IP40

B
Reliable insulation;
With isolation function indication;
O (open), I (closed) and free trip 3 position indications;
The circuit breaker can be locked in the OFF position through 1~3 padlocks with a diameter of
5~8mm.
(Padlock user prepared)

9.7.2 Model description


DRH 21- M8 T

Circuit breaker type: T: Thermal magnetic circuit breaker, M: Magnetic


circuit breaker, SD: Switch disconnector; E: Electronic circuit breaker

Series code:NM8N series

Frame size code: 21 for 125 frame; 22 for 250 frame;


23 for 400/630 frame;
Direct rotary handle code

9.7.3 Installation dimension drawing

Overall dimension of DRH21-M8

113.5 48
76
15.3 35
M

Handle center
70
13.3

Product center
37

94

Z
90(3P)
120(4P)

Overall dimension of DRH22-M8

126 48
93
15.5 37.5
M

Handle center
77

Product center
38.5

94

105(3P) Z
140(4P)
P- 062

Overall dimension of DRH23-M8

122 152 48
18 36

160
Handle center
121

24.5

Product center
67

80
140(3P)
185(4P)

9.8 ERH Extended rotary handle


9.8.1 Function
The unique design and transmission structure are adopted to realize the closing, opening and re-
closing operation of the circuit breaker by rotating the handle.
Protection degree: IP50
Reliable insulation;
With isolation funtion indication;
O (open), I (closed) and free trip 3 position indications;
When the switch cabinet door is opened, the setting value of the circuit breaker release can be
set;
When the switch cabinet door is opened, it can prevent the circuit breaker from closing;
The circuit breaker can be locked in the OFF position through (1~3) padlocks with a diameter of
(5~8) mm;
(Padlock user prepared) can prevent the switch cabinet door from opening at this time;
When the switch is in the ON position, the cabinet door cannot be opened under the action of
the rotary handle (if the cabinet door is opened urgently, the cabinet door can be opened by the
emergency unlocking device on the handle).

9.8.2 Model description

DRH 21- M8 T

Circuit breaker type: T: Thermal magnetic circuit breaker, M: Magnetic


circuit breaker, SD: Switch disconnector; E: Electronic circuit breaker

Series code:NM8N series

Frame size code: 21 for 125 frame; 22 for 250 frame;


23 for 400/630 frame;

Extended rotary handle code

Note: default length of shaft is 500mm


P- 063

9.8.3 Installation dimension drawing

Overall and mounting dimension of ERH21-M8

76 153
15.3
63
M

B
Handle center
13.3

Product center

15.5

94
21
Min=50mm

90(3P)
120(4P)
75 2xΦ4.5
Φ50

37.5

51
75

Hinge
131.5

51

≥200

Overall and mounting dimension of ERH22-M8

93 153
15.5
63
M

Handle center
9

Product center

15.5
94

21
Min=50mm

105(3P)
140(4P) 75 2xΦ4.5
Φ50
37.5
75

51

Hinge
131.5

51

≥200
P- 064

122 190
18
63

Handle center
24.5

Product center
15.5

80
21
Min=50mm

140(3P)
185(4P)
75

2xΦ4.5
Φ50
37.5
75

51
160

Hinge

51

≥200

9.9 LHD Extended handle


9.9.1 Function
With a unique design, the circuit breaker can be closed, opened and re-latched by rotating the
handle. It is only applicable to 1600A.

9.9.2 Model description

LHD 25- M8

Series code:NM8N series

Frame size code: 25 for 1600 frame

Extended handle code

9.9.3 Overall dimension


P- 065

9.10 KLK Locking system


9.10.1 Function
The locking system locks the open position of the circuit breaker.
The locking system can be equipped with (1~3) padlocks with a diameter range (5~8) mm.
(Padlock user prepared)

9.10.2 Model description


KLK 21- M8
B
Series code:NM8N series

Frame size code: 21 for 125 frame; 22 for 250 frame;


23 for 400/630 frame;
Extended handle code

9.11 MIT Mechanical interlock


9.11.1 Function
When used together with two circuit breakers with the same housing, when one circuit breaker is
closed, the other circuit breaker cannot be closed and is in the open state.

9.11.2 Model description

MIT 21- M8 3P

Poles: 3P;4P (It is only applicable to 25、250、400、630); 800 No code


for shell frame

Series code:NM8N series

Frame size code: 21 for 125 frame; 22 for 250 frame;


23 for 400/630 frame; 24 for 800 frame

Mechanical interlock code

9.12 TCV Short terminal cover


9.12.1 Function
Prevents contact with the main circuit and can also be used to prevent short circuit between phases.
Protection degree: IP40
For voltages ≥ 500V, terminal covers must be fitted

9.12.2 Model description

TCV 21- M8 3P

Poles: 3P;4P

Series code:NM8N series

Frame size code: 21 for 125 frame; 22 for 250 frame;


23 for 400/630 frame; 24 for 800 frame

Short terminal cover code


P- 066

9.13 TCE Long terminal cover


9.13.1 Function
Prevents contact with the main circuit and can also be used to prevent short circuit between phases.
There are knock-out holes in front of the terminal cover to accommodate various lug cables and front
wiring.
Protection degree: IP40
For voltages ≥ 500V, terminal covers must be fitted

9.13.2 Model description

TCE 21- M8 3P

Number of poles: 3P;4P

Series code:NM8N series

Frame size code: 21 for 125 frame; 22 for 250 frame;


23 for 400/630 frame; 24 for 800 frame

Long terminal cover code

9.14 FCP Front connection plate


9.14.1 Function
Make the circuit breaker have a flexible wiring mode.By installing this acceccory, the pole spacing can
be increased to increase the electrical gap between adjacent poles at the inlet and outlet ends of the
circuit breaker and enhance the safety between lines.

9.14.2 Model description

FCP 25- M8 3P(16001))

Number of poles: 1P/2P(only for 125A and 250 frames); 3P; 4P

Series code:NM8N series

Frame size code: 21 for 125 frame; 22 for 250 frame;


23 for 400/630 frame; 25 for 1600 frame

Front connection plate code

Note1): Only applicable to 1600 frame, there are three specifications of 1000, 1250, 1600.

9.15 RCP Rear connection plate


9.15.1 Function
Make the circuit breaker have flexible wiring mode, Which can realize the wiring behind the board.

9.15.2 Model description

RCP 25- M8 2P

Number of poles: 1P/2P(only for 125A and 250 frames); 3P; 4P

Series code:NM8N series

Frame size code: 21 for 125 frame; 22 for 250 frame;


23 for 400/630 frame; 24 for 800 frame

Rear connection plate code


P- 067

9.16 CCT Cage clamp terminal


9.16.1 Function
Make the circuit breaker have a flexible wiring mode, which can directly connect the bare wires.
9.16.2 Model description
CCT 21- M8

CCT21/22-M8
Series code:NM8N series
Frame size code: 21 for 125 frame; 22 for 250 frame;
B
23 for 400/630 frame
Cage clamp terminal code
9.16.3 Wiring capacity

Serial No. Wiring capacity Terque


CCT21-M8 (2.5~75)mm2 8N·m
CCT22-M8 (10~120)mm2 10N·m
CCT23-M8 (120~240)mm2 35N·m
CCT23-M8
9.17 MC Cable connector
9.17.1 Function
Make the circuit breaker have a flexible wiring method, which can directly connect the bare wires and
realize the connection of multiple.
9.17.2 Model description
MC 25- M8(3) (12501))

Current specifications
Number of external holes: (1) 1 hole; (2) 2 holes; (3) 3 holes; (4) 4 holes;
(6) 6 holes
Series code:NM8N series
Frame size code: 21 for 125 frame; 22 for 250 frame;
23 for 400/630 frame; 24 for 800 frame; 25 for 1600 frame;

Cable connector code


Note1): Only applicable to 1600 housing, only 800-1250 specifications.
9.17.3 Wiring capacity
Serial No. Wiring capacity Torgue Note
MC21-M8 (1) (16~95)mm2 10N·m 1 hole
MC22-M8 (1) (35~240)mm2 30N·m 1 hole
MC22-M8 (2) 2×(35~120)mm2 30N·m 2 holes
MC22-M8 (6) 6×(10~35)mm2 10N·m 6 holes
MC23-M8 (2) 2×(120~240)mm2 35N·m 2 holes
MC23-M8 (4) 4×95mm2 15N·m 4 holes
MC24-M8 (2) 2×240mm2 35N·m 2 holes
MC25-M8(800) (3) 3×(95~300)mm2 35N·m 3 holes
MC25-M8(1000/1250) (4) 4×(95~240)mm2 35N·m 4 holes

9.18 PIA Plug-in base


9.18.1 Function
Quickly change the circuit breaker without changing the inlet and outlet wires and installing the
base;
Plug-in base can be pre-installed, which is conbenient for customers to add circuit breakers in the
future;
When the circuit breaker is installed through the board or the base, the power circuit can be
isolated;
With plug-in safety device function (optional), it can ensure that the circuit breaker can trip
automatically when it is pulled out when the circuit breaker is closed.
9.18.2 Model description

PIA 21F- M8 3P

Number of holes: 3P; 4P

Series code:NM8N series

Code of wiring method: F for front connection; B for rear connection


Frame size code: 21 for 125 frame; 22 for 250 frame;
23 for 400/630 frame;
Plug-in base code
P- 068

9.19 PISD plug-in safety device


9.19.1 Function
Used together with the plug-in base, it can ensure that the circuit breaker can automatically trip when
it is pulled out when the circuit breaker is closed.
9.19.2 Model description

PISD 21-M8 T

Circuit breaker type: T thermal magnetic circuit breaker; E electronic circuit


breaker
Series code:NM8N series

Frame size code: 21 for 125 frame; 22 for 250 frame;


23 for 400/630 frame;
Plug-in safety device code

9.20 DOB Draw-out base


9.20.1 Function
Quickly change the circuit breaker without changing the inlet and outlet wires and installing the
base;
Withdrawable base can be installed in advance to provide convenience for customers
to add circuit breakers later;
With plug-in safety device function (optional), it can ensure that the circuit breaker can
automatically trip when it is pulled out when the circuit breaker is closed.

9.20.2 Model description

DOB 23F- M8 3P(400A)1)

Number of poles: 3P; 4P

Series code:NM8N series

Code of wiring method: F for front connection; B for rear connection

Frame size code: 23 for 400/630 frame; 24 for 800 frame

Draw-out base code

Note1): DOB23 is suitable for 400/630 housings. There are two specifications of 400 and 630.

9.21 DRA DIN-rail adapter


9.21.1 Function
Adapt to the body and can be mounted on a 35mm standard DIN rail.

9.21.2 Model description

DRA 21-M8 3P

Number of poles: 3P; 4P

Series code:NM8N series

Frame size code: 21 for 125 frame; 22 for 250 frame;

DIN-rail adapter code


P- 069

9.22 PIA Plug-in base


9.22.1 Function
The COMA communication module is an interface module for the communication between the
electronic plastic case circuit breaker and the bus system, and performs communication and relay
control output. Combined with the Modbus-RTU communication protocol, this communication module
can easily establish a connection with a fieldbus master device to achieve three remote or four remote
functions.
The technical parameters are as follows:
Rated voltage: AC230V or DC24V (error range ± 15%)
B
Communication type: RS485 (Modbus-RTU protocol)
Contact capacity: AC250V / 3A; DC30V / 3A
Transmission distance: shielded twisted pair
Transmission distance: 1.2km (using category A shielded twisted pair)
Working status indication: LED indication
Number of stations: 1 station
9.22.2 Model description

COMA 22- M8 DC24V 0.5m

Cable length
Rated voltage: AC230V, DC24V

Series code:NM8N series


Frame code: 22 is a universal accessory for electronic molded case circuit
breakers
Communication module code

9.22.3 Communication solution

Achievable
Solutions Required products and accessories Note
function
NM8N basic or standard electronic molded
Remote
Solution 1 case circuit breaker; 1. Read phase current
measure
COMA22-M8 communication module.
NM8N basic or standard electronic moulded
case circuit breaker;
1. Read phase current
Remote COMA22-M8 communication module;
2. Indicate circuit breaker
Solution 2 measure AX auxiliary contact (optional, indicating
position information (open,
Remote signal opening and closing status);
closed, trip status)
AL alarm contact (optional, indicating trip
status).
NM8N basic or standard electronic moulded
case circuit breaker; 1. Read phase current
Remote
COMA22-M8 communication module; 2. Indicate circuit breaker
measure
AX auxiliary contact (optional, indicating position information (open,
Solution 3 Remote signal
opening and closing status); closed, trip status)
Remote
AL alarm contact (optional, indicating trip 3. Control circuit breaker
control
status); opening and closing
MOD electric operation mechanism.

1. Read phase current


2. Indicate circuit breaker
NM8N standard electronic molded case circuit position information (open,
Remote
breaker; closed, trip status)
measure
COMA22-M8 communication module; 3. Control circuit breaker
Remote signal
AX auxiliary contact (optional, indicating opening and closing
Solution 4 Remote
opening and closing status); 4. Adjust the internal
control
AL alarm contact (optional, indicating trip parameter settings of the
Remote
status); controller (only for standard
adjustment
MOD electric operation mechanism. specifications. For details,
please refer to the
communication protocol).
P- 070

9.23 PSU battery box


9.23.1 Function
Provide DC 9V power for the standard (liquid crystal) controller for users to view, set and modify
controller parameters, when current under 0.4In. The batteries inside box are changeble.
Output voltage: DC 9V
Continuous power supply time: 7 hours

9.23.2 Model description

PSU 22-M8

Series code:NM8N series

Frame size code: 22 is a universal accessory for standard (liquid crystal)


electronic molded case circuit breakers

Battery box code

9.24 PSU battery box


9.24.1 Function
Guarantees phase-to-phase insulation safety and prevents phase-to-phase short circuit.

9.24.2 Model description

PHS 21-M8

Series code:NM8N series

Shell code: 21 for 125 frame; 22 for 250 frame; 23 for 400/630 frame;
24 for 800 frame; 25 for 1600 frame

Phase barrier code, standard accessory


P- 071

9.25 Installation diagram of internal accessories

Left ON Right
Mounting and wiring mode
Handle OFF

B
Accessory name
NM8N-125, 250 NM8N-400, 630
NM8N-800 NM8N-1600 NM8N-1600 MOD
NM8NL-125, 250 NM8NL-400, 630

3P, 4P 3P, 4P 3P, 4P 3P, 4P 3P, 4P

No accessory

Alarm contact

Auxiliary contact

Shunt release

Under-voltage release

Shunt release
Auxiliary contact

Auxiliary contact
Under-voltage telease

Shunt release
Alarm contact

Auxiliary contact
Alarm contact

Under-voltage release
Alarm contact

Shunt release
Auxiliary contact, alarm
Auxiliary contact
alarm contact
Under-voltage release

■-Shunt release ▲-Under-voltage release ○-Auxiliary contact ●-Alarm contact

Note: a. NM8N-125, 250, 400, 630, 800 cannot be eqipped with undervoltage release and shunt release at the same time;
b. NM8N-125, 250 3P/4P can be equipped with a maximum of 2 sets of auxiliary contacts; 1P has no internal accessories; 2P can be equipped
with a maximum of one auxiliary / alarm contact at the same time;
c. NM8N-400, 630 can install up to 3 sets of auxiliary contacts;
d. NM8N-800 can be eqipped with up to 4 auxiliary contacts;
e. NM8N-1600 MOD can be equipped with a maximum of 3 sets of auxiliary contacts, and can simultaneously install undervoltage release and
shunt release;
f. NM8N series can only be equipped with one alarm contact.
P- 072

10. Technical Supplement


10.1 DC application wiring method

Solutions Unipolar grounding system Ungrounded system

Circuit diagram

maximum short-circuit
Fault A Fault A has no effect
current Isc

maximum short-circuit maximum short-circuit


Impact of falt Fault B Fault B
current Isc current Isc

Fault C has no effect Fault C has no effect

Load

≤DC500V

Load
Note: Note:
1. The upper and lower lines can be used, here the 1. Both the upper and lower lines can be used, here the
following lines are taken as an example. following lines are taken as an example; 2. Make sure
that the installation method does not cause a secondary
ground fault.

Load

DC500~750V

Load
Note: Note:
1. The upper and lower lines can be used, here the 1. Both the upper and lower lines can be used, here the
following lines are taken as an example. following lines are taken as an example; 2. Make sure
that the installation method does not cause a secondary
ground fault.

Load

DC750~1000V

Load

Load

Note:
1. The upper and lower lines can be used, here the
following lines are taken as an example.
P- 073

10.2 NM8N power loss table


Fixed circuit breaker
Rated current Power loss
Release type Model resistance loss per pole
(A) per pole (W)

16 8.8 2.3
20 8.8 3.5

B
25 5.2 3.3
32 4.5 4.6
40 2.6 4.2
NM8N-125
50 1.8 4.5
63 1.7 6.7
80 1.3 8.3
100 0.88 8.8
125 0.8 12.5
125 0.7 10.9
160 0.55 14.1
180 0.55 17.8
NM8N-250
200 0.55 22.0

Thermal 225 0.4 20.3


magnetic 250 0.4 25.0
250 0.35 21.9
315 0.25 24.8
NM8N-400
350 0.25 30.6
400 0.15 24.0
400 0.15 24.0
NM8N-630
500 0.12 30.0
500 0.08 20.0
630 0.08 31.8
NM8N-800
700 0.08 39.2
800 0.08 51.2
800 0.08 51.2
1000 0.08 80.0
NM8N-1600
1250 0.04 62.5
1600 0.04 102.4
32 0.8 0.8
63 0.4 1.6
NM8N-250 100 0.4 4.0
160 0.4 10.2
250 0.4 25.0
250 0.15 9.4
NM8N-400
400 0.15 24.0
Electronic
400 0.15 24.0
NM8N-630
630 0.12 47.6
NM8N-800 800 0.08 51.2
800 0.08 51.2
1000 0.08 80.0
NM8N-1600
1250 0.04 62.5
1600 0.04 102.4
63 0.8 3.2
NM8NSD-125 100 0.8 8.0
125 0.8 12.5
125 0.4 6.3
160 0.4 10.2
Switch NM8NSD-250
200 0.4 16.0
disconnector
250 0.4 25.0
250 0.15 9.4
NM8NSD-400
400 0.15 24.0
NM8NSD-630 630 0.12 47.6
NM8NSD-800 800 0.08 51.2
P- 074

10.3 NM8N thermal magnetic circuit breaker rated operational current and temperature compensation coefficient table

Ambient
temperature
-40℃ -35℃ -25℃ -15℃ -5℃ 0℃ +10℃ +20℃ +30℃ +40℃ +50℃ +60℃ +70℃
Rated current

16A 22.5 22 20.5 20 19.5 19 18.5 17.5 17 16 15 14.5 14

20A 28 27.5 26.5 25.5 24.5 24 23 22 21 20 19.5 18.5 18

25A 35 34 33 32 30.5 30 28 27 26 25 24 22.5 22

32A 45 44 42 41 39 38 37 35 33 32 30.5 29 28

40A 56 55 53 51 49 48 46 44 42 40 37 33.5 29
NM8N-125
50A 70 68.5 66 64 61 60 57.5 55 52.5 50 47.5 45 40

63A 88 86.5 83 80 77 75 72 69 66 63 58.5 53 46

80A 112 110 106 102 98 96 92 88 84 80 74.5 67 56

100A 140 137 132 127 122 120 115 110 105 100 93 84 80

125A 175 172 165 159 153 150 144 137 131 125 116 105 91

125A 175 172 165 159 153 150 144 137 131 125 118 106 96

160A 224 220 212 204 196 192 184 176 168 160 152 136 120

180A 252 247 238 229 220 216 207 198 189 180 171 157 144
NM8N-250
200A 280 275 265 255 245 240 230 220 210 200 190 175 166

225A 315 309 300 288 276 270 259 247 236 225 213 196 180

250A 350 343 332 319 306 300 287 275 262 250 237 218 207

250A 350 343 332 319 306 300 287 275 262 250 237 225 212

315A 441 433 418 402 386 378 362 346 331 315 300 286 271
NM8N-400
350A 490 481 465 447 429 420 402 385 367 350 332 295 276

400A 560 550 530 510 490 480 460 440 420 400 380 360 320

250A 350 343 332 319 306 300 287 275 262 250 237 225 212

315A 441 433 418 402 386 378 362 346 331 315 300 286 271

NM8N-630 350A 490 481 465 447 429 420 402 385 367 350 332 295 276

400A 560 550 530 510 490 480 460 440 420 400 380 360 320

500A 700 687 662 637 612 600 575 550 525 500 450 406 360

500A 700 687 662 637 612 600 575 550 525 500 490 460 400

630A 882 866 836 804 772 756 724 693 661 630 580 530 490
NM8N-800
700A 980 962 927 892 857 840 805 770 735 700 670 645 575

800A 1120 1100 1060 1020 980 960 920 880 840 800 735 670 625

800A 1120 1100 1060 1020 980 960 960 920 840 800 760 696 640

1000A 1400 1375 1325 1275 1225 1200 1200 1150 1050 1000 950 870 800
NM8N-1600
1250A 1750 1718 1656 1594 1531 1500 1500 1437 1312 1250 1187 1088 1000

1600A 2240 2200 2120 2040 1960 1920 1960 1760 1680 1600 1520 1390 1280

Note:1) For a muiti-pole DC circuit breaker, if a 2m long standard wire is used in series, the derating factor above applies.
Note:2) When the copper short-circuit bar is connected in series, it needs to be further reduced based on the above table (except NM8NDC-1600). The
specific derating factor should be determined by users according to their different wiring methods. Derating by a factor of 0.8.
P- 075

10.4 NM8N electronic circuit breaker rated operational current and temperature compensation coefficient table

Ambient
temperature
-25℃ -15℃ -5℃ 0℃ +10℃ +20℃ +30℃ +40℃ +50℃ +60℃ +70℃
Rated current

B
32A 32 32 32 32 32 32 32 32 32 32 32

63A 63 63 63 63 63 63 63 63 63 63 63

NM8N-250 100A 100 100 100 100 100 100 100 100 100 100 100

160A 160 160 160 160 160 160 160 160 160 160 160

250A 250 250 250 250 250 250 250 250 240 225 213

250A 250 250 250 250 250 250 250 250 250 250 250
NM8N-400
400A 400 400 400 400 400 400 400 400 380 360 340

250A 250 250 250 250 250 250 250 250 250 250 250

NM8N-630 400A 400 400 400 400 400 400 400 400 380 360 340

630A 630 630 630 630 630 630 630 630 600 570 540

630A 630 630 630 630 630 630 630 630 630 630 630
NM8N-800
800A 800 800 800 800 800 800 800 800 760 720 680

800A 800 800 800 800 800 800 800 800 800 800 800

1000A 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
NM8N-1600
1250A 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250

1600A 1600 1600 1600 1600 1600 1600 1600 1600 1520 1440 1360

Note: Individual specifications of products need to be derated at a temperature of 50℃ and above (parameters refer to the table), Ir needs to be adjusted
to the corresponding gear.
For example: NM8N-250 EN 250 3P products are used at 70℃ . The product needs to be derated to 213A, and the Ir position is adjusted to 0.8In
position. The NM8N-250 EM 250 3P product is used at 70℃ . The product should be derated to 213A, and the Ir position should be adjusted to 213A.

10.5 Derating factor table for circuit breaker with residual current protection module

Model Derating factor

16A~63A 1

NM8N-125+NM8NL-125 80A~100A 0.9

125A 0.8

125A~180A 1
NM8N-250+NM8NL-250
200A~250A 0.9

32A、63A、100A、160A 1
NM8N-250+NM8NL-250 electronic type
250A 0.95

250A 1

NM8N-400+NM8NL-400 315A、350A 0.96

400A 0.93

250A 1
NM8N-400+NM8NL-400 electronic type
400A 0.95

400A 0.93
NM8N-630+NM8NL-630
500A 0.87

400A~500A 1
NM8N-630+NM8NL-630 electronic type
630A 0.90
P- 076

10.6 Derating factor table for circuit breakers with plug-in or draw-out accessories

Derating factor
Model
+Plug-in type +Economic draw-out type

16A-100A 1 /
NM8N-125
125A 0.95 /

125A-180A 1 /
NM8N-250
200A-250A 0.95 /

NM8N-250 32A、63A、100A、160A 1 /
electronic type 250A 0.95 /

NM8N-400 250A-400A 1 1
NM8N-400
250A-400A 1 1
electronic type
400A 1 1
NM8N-630
500A 0.95 1

NM8N-630 400A-500A 1 1
electronic type 630A 0.9 0.9

500-700A / 0.95
NM8N-800
800A / 0.9

NM8N-800 630A / 1
electronic type 800A / 0.9

10.7 NM8N Derating factor table for circuit breakers altitude

Altitude (m) 2000m 3000m 4000m 5000m

Rated operational current In 1×In 0.96×In 0.93×In 0.9×In

AC 690 550 480 420


Rated operational voltage Ue (V)
DC (4pole string) 1000 900 850 800

Rated insulation voltage Ui (V) 1000 930 870 800

Uimp = 8kV 2200 2050 1900 1770


AC
Uimp = 12kV 2550 2370 2200 2050
Dielectric properties (V)
Uimp = 8kV 3110 2892 2705 2488
DC
Uimp = 12kV 3600 3350 3110 2985

NM8N-125
NM8N-250 8 8 8 8
Rated insulation impulse voltage NM8N-1600
Uimp (kV) NM8N-400
NM8N-630 12 10 8 8
NM8N-800
P- 077

10.8 Cascading (AC220/230/240V)

Upstream NM8N-125 NM8N-250 NM8N-400 NM8N-630 NM8N-800

Breaking C S Q H R C S Q H R C S Q H R C S Q H R C S Q H R
capacity

B
(kA rms) 36 50 70 100 150 36 50 70 100 150 36 50 70 100 150 36 50 70 100 150 36 50 70 100 150

Downstream Breaking capacity (kA rms)

NB1N 25 30 40 60 60 25 30 40 60 60 — — — — — — — — — — — — — — —

NB1H 30 40 50 65 65 30 40 50 65 65 — — — — — — — — — — — — — — —

NM8N-125C 50 60 80 100 50 60 80 100 50 60 80 100 50 60 80 100 50 60 80 100

NM8N125S 70 90 120 70 90 120 70 90 120 70 90 120 70 90 120

NM8N-125Q 90 140 90 140 90 140 90 140 90 140

NM8N-125H 150 60 150 150 150 150

NM8N-250C 50 70 80 100 50 60 80 100 50 60 80 100 50 60 80 100

NM8N-250S 90 120 70 90 120 70 90 120 70 90 120

NM8N-250Q 90 140 90 140 90 140 90 140

NM8N-250H 150 150 150 150

NM8N-400C 50 60 80 100 50 60 80 100 50 60 80 100

NM8N-400S 70 90 120 70 90 120 70 90 120

NM8N-400Q 90 140 90 140 90 140

NM8N-400H 150 150 150

NM8N-630C 50 60 80 100 50 60 80 100

NM8N-630S 70 90 120 70 90 120

NM8N-630Q 90 140 90 140

NM8N-630H 150 150

NM8N-800C 50 60 80 100

NM8N-800S 70 90 120

NM8N-800Q 90 140

NM8N-800H 150
P- 078

10.9 Cascading (AC380/400/415V)

Upstream NM8N-125 NM8N-250 NM8N-400 NM8N-630 NM8N-800

Breaking C S Q H R C S Q H R C S Q H R C S Q H R C S Q H R
capacity
(kA rms) 36 50 70 100 150 36 50 70 100 150 36 50 70 100 150 36 50 70 100 150 36 50 70 100 150

Downstream Breaking capacity (kA rms)

NB1N 20 25 25 25 25 20 25 25 25 25 — — — — — — — — — — — — — — —

NB1H 30 30 30 30 30 30 30 30 30 30 — — — — — — — — — — — — — — —

NM8N-125C 50 50 80 100 50 50 80 100 50 50 80 100 50 50 80 100 50 50 80 100

NM8N125S 70 90 120 70 90 120 70 90 120 70 90 120 70 90 120

NM8N-125Q 90 140 90 140 90 140 90 140 90 140

NM8N-125H 150 150 150 150 150

NM8N-250C 50 50 80 100 50 50 80 100 50 50 80 100 50 50 80 100

NM8N-250S 70 90 120 70 90 120 70 90 120 70 90 120

NM8N-250Q 90 140 90 140 90 140 90 140

NM8N-250H 150 150 150 150

NM8N-400C 50 50 80 100 50 50 80 100 50 50 80 100

NM8N-400S 70 90 120 70 90 120 70 90 120

NM8N-400Q 90 140 90 140 90 140

NM8N-400H 150 150 150

NM8N-630C 50 50 80 100 50 50 80 100

NM8N-630S 70 90 120 70 90 120

NM8N-630Q 90 140 90 140

NM8N-630H 150 150

NM8N-800C 50 50 80 100

NM8N-800S 70 90 120

NM8N-800Q 90 140

NM8N-800H 150
P- 079

Note

B
P- 080

10.10 Selective protection

Upstream
NM8N-125 NM8N-250 NM8N-250 Electronic

Downstream In (A) 16 20 25 32 40 50 63 80 100 125 125 160 180 200 225 250 32 63 100 160 250

≤10 190 190 300 400 500 500 500 630 800 1000 T T T T T T 400 500 1000 T T

16 300 400 500 500 500 630 800 1000 T T T T T T 400 500 1000 T T

20 500 500 500 630 800 1000 T T T T T T 500 1000 T T

NB1 25 500 500 630 800 1000 T T T T T T 500 1000 T T


Tripping currve:B/C 32 500 630 800 1000 2000 5000 T T T T 500 1000 T T

40 630 800 1000 2000 5000 T T T T 1000 T T

50 800 1000 2000 5000 T T T T 1000 T T

63 1000 2000 5000 T T T T 1000 T T

16 400 500 500 630 800 1000 1000 2500 2500 2500 2500 2800 500 1000 2500 2800

50 500 500 630 800 1000 1000 2500 2500 2500 2500 2800 500 1000 2500 2800

25 500 630 800 1000 1000 2500 2500 2500 2500 2800 500 1000 2500 2800

32 630 800 1000 1000 2500 2500 2500 2500 2800 1000 2500 2800

40 800 1000 1000 2000 2000 2500 2500 2800 1000 2000 2800
NM8N-125
50 1000 1000 2000 2000 2500 2500 2800 1000 2000 2800

63 1000 2000 2000 2500 2500 2800 2000 2800

80 2000 2000 2500 2500 2800 2000 2800

100 2500 2500 2800 2800

125 2500 2800 2800

125

160

180
NM8N-250
200

225

250

32 1000 2000 2800

63 2000 2800
NM8N-250
100 2800
Electronic
160

250

250

315
NM8N-400
350

400

NM8N-400 250
Electronic 400

250

315

NM8N-630 350

400

500

250
NM8N-630
400
Electronic
630

Note: 1) No content, meaning no selectivity.


Note: 2) 1000, which indicates local selectivity, and the number indicates the maximum fault current to achieve selectivity. For example, selectivity below
1000A can be achieved here, and upper and lower circuit breakers above 1000A may operate simultaneously.
Note: 2) T, which means that full selectivity is satisfied within the breaking capacity of the lower circuit breaker.
P- 081

NM8N NM8N
NM8N-630
NM8N-400 -400 NM8N-630 NM8N-800 -800 NM8N-1600 NM8N-1600 Electronic
Electronic
Electronic Electronic

250 315 350 400 250 400 250 315 350 400 500 250 400 630 500 630 700 800 800 800 1000 1250 1600 800 1000 1250 1600

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
T

T
B
T T T T T T T T T T T T T T T T T T T T T T T T T T T

T T T T T T T T T T T T T T T T T T T T T T T T T T T

T T T T T T T T T T T T T T T T T T T T T T T T T T T

T T T T T T T T T T T T T T T T T T T T T T T T T T T

T T T T T T T T T T T T T T T T T T T T T T T T T T T

T T T T T T T T T T T T T T T T T T T T T T T T T T T

T T T T T T T T T T T T T T T T T T T T T T T T T T T

T T T T T T T T T T T T T T T T T T T T T T T T T T T

T T T T T T T T T T T T T T T T T T T T T T T T T T T

T T T T T T T T T T T T T T T T T T T T T T T T T T T

2800 3500 4000 5000 2800 5000 2800 3500 4000 5000 T 2800 5000 T T T T T T T T T T T T T T

2800 3500 4000 5000 2800 5000 2800 3500 4000 5000 T 2800 5000 T T T T T T T T T T T T T T

2800 3500 4000 5000 2800 5000 2800 3500 4000 5000 T 2800 5000 T T T T T T T T T T T T T T

2800 3500 4000 5000 2800 5000 2800 3500 4000 5000 T 2800 5000 T T T T T T T T T T T T T T

2800 3500 4000 5000 2800 5000 2800 3500 4000 5000 T 2800 5000 T T T T T T T T T T T T T T

2800 3500 4000 5000 2800 5000 2800 3500 4000 5000 T 2800 5000 T T T T T T T T T T T T T T

2800 3500 4000 5000 2800 5000 2800 3500 4000 5000 T 2800 5000 T T T T T T T T T T T T T T

2800 3500 4000 5000 2800 5000 2800 3500 4000 5000 T 2800 5000 T T T T T T T T T T T T T T

3500 4000 5000 5000 3500 4000 5000 T 5000 T T T T T T T T T T T T T T

4000 5000 5000 4000 5000 T 5000 T T T T T T T T T T T T T T

5000 5000 5000 T 5000 T T T T T T T T T T T T T T

5000 5000 5000 T 5000 T T T T T T T T T T T T T T

2800 3500 4000 5000 2800 5000 2800 3500 4000 5000 T 2800 5000 T T T T T T T T T T T T T T

2800 3500 4000 5000 2800 5000 2800 3500 4000 5000 T 2800 5000 T T T T T T T T T T T T T T

2800 3500 4000 5000 2800 5000 2800 3500 4000 5000 T 2800 5000 T T T T T T T T T T T T T T

4000 5000 5000 4000 5000 T 5000 T T T T T T T T T T T T T T

5000 5000 5000 T 5000 T T T T T T T T T T T T T T

5000 5000 6000 9500 9500 9500 9500 9500 9500 9500 12000 15000 19000 9500 12000 15000 19000

6000 9500 9500 9500 9500 9500 9500 9500 12000 15000 19000 9500 12000 15000 19000

9500 9500 9500 9500 9500 9500 12000 15000 19000 9500 12000 15000 19000

9500 9500 9500 9500 9500 12000 15000 19000 9500 12000 15000 19000

5000 5000 6000 5000 9500 9500 9500 9500 9500 9500 9500 12000 15000 19000 9500 12000 15000 19000

9500 9500 9500 9500 9500 12000 15000 19000 9500 12000 15000 19000

5000 5000 6000 9500 9500 9500 9500 9500 9500 9500 12000 15000 19000 9500 12000 15000 19000

6000 9500 9500 9500 9500 9500 9500 9500 12000 15000 19000 9500 12000 15000 19000

9500 9500 9500 9500 9500 9500 12000 15000 19000 9500 12000 15000 19000

9500 9500 9500 9500 9500 12000 15000 19000 9500 12000 15000 19000

9500 9500 9500 9500 9500 9500 12500 16000 9500 9500 12500 16000

5000 5000 6000 5000 9500 9500 9500 9500 9500 9500 9500 12000 15000 19000 9500 12000 15000 19000

9500 9500 9500 9500 9500 12000 15000 19000 9500 12000 15000 19000

9500 12500 16000 9500 12500 16000


P- 082

11. Ordering notice


11.1 Quick selection of circuit breaker
11.1.1 Quick selection of power distribution and motor protection circuit breakers1

NM8N 250 S TM 125 4C OTHER

Frame Breaking Special


Circuit breaker Release type Rated current(A) Poles
current(A) code requirement

TM/M EN/EM/ENM/EMM

M: Magnetic for 125 : 16, 20, 25, 1P : One pole


3 2, 4 0 , 5 0 , 6 3 ,
motor protection — 2P : Two-pole
80,
TM: Thermal 100, 125 3P : Three-pole
Magnetic for 4B : Four-pole2)
Distribution 4C : Four-pole2)
25 0 : 125, 16 0,
Protection 250 : 32, 63, 100
18 0 , 2 0 0 , 2 2 5 ,
EN: Electronic 160, 250
125 C : 36kA 250
Basic for
250 S : 50kA
Distribution
400 Q : 70kA
Protection
630 H : 100kA 400 : 250, 315
EM: Electronic 400 : 250, 400
800 R : 150kA 350, 400
Standard for
Distribution
Protection 3P : Three-pole
ENM: Electronic 630 : 400, 500 630 : 400, 630 4B : Four-pole2)
NM8N Standard 4C : Four-pole2)
moulded case for Motor
circuit breaker Protection
800 : 500, 630
800 : 630, 800
700, 800

TM: Thermal TM/EN/EM


Magnetic for
Distribution
Protection
EN: Electronic
MOD DC1103)
S : 50kA Basic for 3P : Three-pole 3)
2) MOD DC220
1600 Q : 70kA Distribution 4B : Four-pole 3)
MOD AC230
H : 100kA Protection 1600 : 800, 1000, 1250, 1600 4C : Four-pole2)
MOD AC4003)
EM: Electronic
Standard for
Distribution
Protection

Note: 1) For customer needs beyond the technical requirements of the sample, you can contact the company's sales department or technical department
as a special order processing; The body and accessories should be written separately when ordering. If the user requires the factory to assemble
the body and accessories, it must be specified when ordering, otherwise the factory will ship separately; Motor protection is only applicable to
3P / 4P;
2)
4B: Neutral poles without protection, can be operated with other three poles;
4C: Neutral poles with protection, can be operated with other three poles.
3)
Only NM8N-1600 has motor type
P- 083

11.1.2 Quick selection of DC circuit breaker

NM8N

DC 250 S TM 125 2P OTHER


B
Rated Special
Current type Frame current(A) Breaking code Release type Poles
current(A) requirement

125 : 16, 20, 25,


32, 40, 50, 63, 80,
100, 125

2 5 0 : 12 5 , 16 0 ,
18 0, 2 0 0, 2 2 5,
B : 25kA 250
125
C : 36kA TM: Thermal 1P : One pole1)
250
S : 50kA Magnetic 2P : Two-pole1)
400
Q : 70kA for Distribution 3P : Three-pole
630 400 : 250, 315
H : 100kA Protection 350, 400 4P : Four-pole
800

630 : 400, 500

DC : Direct current

800 : 500, 630


700, 800

TM: Thermal
B : 25kA Magnetic 1600 : 800, 1000, 3P : Three-pole
1600
C : 36kA for Distribution 1250, 1600 4P : Four-pole
Protection

Note: 1) 1P / 2P is limited to 125 and 250 frame products.


P- 084

11.1.3 Quick selection of switch disconnector

NM8N

SD 250 AC 125 2P OTHER

Switch Special
Frame current(A) Release type Rated current(A) Poles
disconnector requirement

125 : Default
125 250 : Default
250
SD : Switch AC: Alternating current 2P : Two-pole1)
400 400 : Default
disconnector DC: Direct current 3P : Three-pole
630
800 : Default 4P : Four-pole
800
1600 : 800, 1000,1250, 1600

Note: 1) 2P is only for 125 and 250 frame products.


P- 085

Note

B
P- 086

11.2 NM8N accessory models selection table


Accessory type Code Specification NM8N-125 NM8N-250
Universal AX21-M8
Auxiliary contact AX
Neutral AX21-M8 N
Universal AL21-M8
Alarm contact AL
Neutral AL21-M8 N
AC48V SHT21-M8 AC48V SHT22-M8 AC48V
AC110V SHT21-M8 AC110V SHT22-M8 AC110V
AC220-240V SHT21-M8 AC220-240V SHT22-M8 AC220-240V
Shunt release SHT
AC380-415V SHT21-M8 AC380-415V SHT22-M8 AC380-415V
DC24V SHT21-M8 DC24V SHT22-M8 DC24V
DC220V SHT21-M8 DC220V SHT22-M8 DC220V
AC48V UVT21-M8 AC48V UVT22-M8 AC48V
AC110V UVT21-M8 AC110V UVT22-M8 AC110V
AC220-240V UVT21-M8 AC220-240V UVT22-M8 AC220-240V
AC380-415V UVT21-M8 AC380-415V UVT22-M8 AC380-415V
Under-voltage release UVT
DC24V UVT21-M8 DC24V UVT22-M8 DC24V
DC48V UVT21-M8 DC48V UVT22-M8 DC48V
DC110-120V UVT21-M8 DC110-120V UVT22-M8 DC110-120V
DC220V UVT21-M8 DC220V UVT22-M8 DC220V
AC110/DC110-120V MOD21-M8 AC110/DC110-120V MOD22-M8 AC110/DC110-120V
AC220-240/DC220V MOD21-M8 AC220-240V/DC220V MOD22-M8 AC220-240V/DC220V
Motor-driven mechanism MOD
AC380-415V MOD21-M8 AC380-415V MOD22-M8 AC380-415V
DC24V MOD21-M8 DC24V MOD22-M8 DC24V
Economic extended 3P SRH21-M8 3P SRH22-M8 3P
SRH
rotart handle 4P SRH21-M8 4P SRH22-M8 4P
Thermal magnetic (T) DRH21-M8 T DRH22-M8 T
Magnetic (M) DRH21-M8 M DRH22-M8 M
Direct rotary handle DRH
Electronic (E) / DRH22-M8 E
Switch disconnector (SD) DRH21-M8 M DRH22-M8 SD
Thermal magnetic (T) ERH21-M8 T ERH22-M8 T
Magnetic (M) ERH21-M8 M ERH22-M8 M
Extended rotary handle ERH
Electronic (E) / ERH22-M8 E
Switch disconnector (SD) ERH21-M8 M ERH22-M8 SD
Extended rotary handle LHD 3P/4P / /
Locking system KLK KLK21-M8 KLK22-M8
3P MIT21-M8 3P MIT22-M8 3P
Mechanical interlock MIT
4P MIT21-M8 4P MIT22-M8 4P
3P TCV21-M8 3P TCV22-M8 3P
Short terminal cover TCV
4P TCV21-M8 4P TCV22-M8 4P
3P TCE21-M8 3P TCE22-M8 3P
Long terminal cover TCE
4P TCE21-M8 4P TCE22-M8 4P
1P FCP21-M8 1P FCP22-M8 1P
2P FCP21-M8 2P FCP22-M8 2P
Front connection plate FCP
3P FCP21-M8 3P FCP22-M8 3P
4P FCP21-M8 4P FCP22-M8 4P
1P RCP21-M8 1P RCP22-M8 1P
2P RCP21-M8 2P RCP22-M8 2P
Rear connection plate RCP
3P RCP21-M8 3P RCP22-M8 3P
4P RCP21-M8 4P RCP22-M8 4P
Cage clamp terminal CCT 1hole CCT21-M8 CCT22-M8
1hole MC21-M8(1) MC22-M8(1)
2hole / MC22-M8(2)
Cable connector MC 3hole / /
4hole / /
6hole / MC22-M8(6)
3P Front connection PIA21F-M8 3P PIA22F-M8 3P
4P Front connection PIA21F-M8 4P PIA22F-M8 4P
Plug-in base PIA
3P Rear connection PIA21B-M8 3P PIA22B-M8 3P
4P Rear connection PIA21B-M8 4P PIA22B-M8 4P
Thernal magnetic (T) PISD21-M8 T PISD22-M8 T
Plug-in safety device PISD
Electronic (E) / PISD22-M8 E
3P Front connection / /
4P Front connection / /
Draw-out base DOB
3P Rear connection / /
4P Rear connection / /

3P DRA21-M8 3P DRA22-M8 3P
DIN-rail adapter DRA
4p DRA21-M8 4P DRA22-M8 4P

/ COMA22-M8 DC24V 0.5m


DC24V / COMA22-M8 DC24V 1.5m
/ COMA22-M8 DC24V 3m
Communication module COMA
/ COMA22-M8 AC230V 0.5m
AC230V / COMA22-M8 AC230V 1.5m
/ COMA22-M8 AC230V 3m
Battery box PSU / PSU22-M8
Phase barrier PHS PHS21-M8 PHS22-M8
P- 087

NM8N-400 NM8N-630 NM8N-800 NM8N-1600


AX21-M8
AX21-M8 N
AL21-M8
AL21-M8 N

B
SHT22-M8 AC48V SHT24-M8 AC48V SHT25-M8 AC48V
SHT22-M8 AC110V SHT24-M8 AC110V SHT25-M8 AC110V
SHT22-M8 AC220-240V SHT24-M8 AC220-240V SHT25-M8 AC220-240V
SHT22-M8 AC380-415V SHT24-M8 AC380-415V SHT25-M8 AC380-415V
SHT22-M8 DC24V SHT24-M8 DC24V SHT25-M8 DC24V
SHT22-M8 DC220V SHT24-M8 DC220V SHT25-M8 DC220V
UVT22-M8 AC48V UVT24-M8 AC48V UVT25-M8 AC48V
UVT22-M8 AC110V UVT24-M8 AC110V UVT25-M8 AC110V
UVT22-M8 AC220-415V UVT24-M8 AC220-240V UVT25-M8 AC220-240V
UVT22-M8 AC380-415V UVT24-M8 AC380-415V UVT25-M8 AC380-415V
UVT22-M8 DC24V UVT24-M8 DC24V UVT25-M8 DC24V
UVT22-M8 DC48V UVT24-M8 DC48V UVT25-M8 DC48V
UVT22-M8 DC110-120V UVT24-M8 DC110-120V UVT25-M8 DC110-120V
UVT22-M8 DC220V UVT24-M8 DC220V UVT25-M8 DC220V
MOD23-M8 AC110/DC110-120V MOD24-M8 AC110/DC110-120V MOD25-M8 AC110/DC110-120V
MOD23-M8 AC220-240V/DC220V MOD24-M8 AC220-240V/DC220V MOD25-M8 AC220-240V/DC220V
MOD23-M8 AC380-415V MOD24-M8 AC380-415V MOD25-M8 AC380-415V
MOD23-M8 DC24V MOD24-M8 DC24V MOD25-M8 DC24V

SRH23-M8 SRH24-M8 SRH25-M8

DRH23-M8 T / /
DRH23-M8 M / /
DRH23-M8 E / /
DRH23-M8 SD / /
ERH23-M8 T / /
ERH23-M8 M / /
ERH23-M8 E / /
ERH23-M8 SD / /
/ / LHD25-M8
KLK23-M8 / /
MIT23-M8 3P /
MIT24-M8
MIT23-M8 4P /
TCV23-M8 3P TCV24-M8 3P /
TCV23-M8 4P TCV24-M8 4P /
TCE23-M8 3P TCE24-M8 3P /
TCE23-M8 4P TCE24-M8 4P /
/ / /
/ / /
FCP23-M8 3P / FCP25-M8 3P
FCP23-M8 4P / FCP25-M8 4P
/ / /
/ / /
RCP23-M8 3P RCP24-M8 3P /
RCP23-M8 4P RCP24-M8 4P /
CCT23-M8 / /
/ / /
MC23-M8(2) MC24-M8(2) /
/ / MC25-M8(3)(800)
MC23-M8(4) / MC25-M8(4)(1000/1250)
/ / /
PIA23F-M8 3P / /
PIA23F-M8 4P / /
PIA23B-M8 3P / /
PIA23B-M8 4P / /
PISD23-M8 T PISD24-M8 T /
PISD23-M8 E PISD24-M8 E /
DOB23F-M8 3P(400A) DOB23F-M8 3P(630A) DOB24F-M8 3P /
DOB23F-M8 4P(400A) DOB23F-M8 4P(630A) DOB24F-M8 4P /
DOB23B-M8 3P(400A) DOB23B-M8 3P(630A) DOB24B-M8 3P /
DOB23B-M8 4P(400A) DOB23B-M8 4P(630A) DOB24B-M8 4P /
/
/
/ / /
/ / /
COMA22-M8 DC24V 0.5m
COMA22-M8 DC24V 1.5m
COMA22-M8 DC24V 3m
COMA22-M8 AC230V 0.5m
COMA22-M8 AC230V 1.5m
COMA22-M8 AC230V 3m
PSU22-M8
PHS23-M8 PHS24-M8 PHS25-M8
P- 088

Note

You might also like