Circuit-breaker,�4�p,�320A
Part�no. LZMC3-4-A320-I
Article�no. 116439
Similar to illustration
Delivery�programme
Product range Circuit-breaker
Protective function System and cable protection
Standard/Approval IEC
Installation type Fixed
Release system Thermomagnetic release
Construction size LZM3
Description Set value in neutral conductor is synchronous with set value Ir of main pole.
Number of poles 4 pole
Standard equipment Screw connection
Switching�capacity
400/415 V 50/60 Hz Icu kA 36
Rated�current�=�rated�uninterrupted�current
Rated current = rated uninterrupted current In = Iu A 320
Neutral conductor % of phase CSA 100
conductor
Setting�range
Overload trip
Ir A 250 - 320
Main pole Ir A 250 - 320
Short-circuit releases
Non-delayed Ii = In x … 6 - 10
Technical�data
General
Standards IEC/EN 60947, VDE 0660
Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100
Climatic proofing Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC g 20 (half-sinusoidal shock 20 ms)
60068-2-27
Safe isolation to EN 61140
Between auxiliary contacts and main contacts V AC 500
between the auxiliary contacts V AC 300
Mounting position Vertical and 90° in all directions
With XFI earth-fault release:
- NZM1, N1, NZM2, N2: vertical and
90° in all directions
with plug-in unit
- NZM1, N1, NZM2, N2: vertical, 90°
right/left
with withdrawable unit:
12/11/2015 116439 - HPL-ED2015 V18.0 EN 1/9
- NZM3, N3: vertical, 90° left
- NZM4, N4: vertical
with remote operator:
- NZM2, N(S)2, NZM3, N(S)3,
NZM4, N(S)4: vertical and 90° in all
directions
Direction of incoming supply as required
Degree of protection
Device In the area of the HMI devices: IP20 (basic protection type)
Enclosures with insulating surround: IP40with door coupling rotary handle: IP66
Terminations Tunnel terminal: IP10
Phase isolator and band terminal: IP00
Circuit-breakers
Rated current = rated uninterrupted current In = Iu A 320
Rated surge voltage invariability Uimp
Main contacts V 8000
Auxiliary contacts V 6000
Rated operational voltage Ue V AC 690
Rated operational voltage Ue V DC 750
The specifications apply to three-pole system-protective circuit breakers with an
NZMN(H)1(2)(3)-A… thermomagnetic release rated for currents of up to 500 A.
The following applies when using the rated operating voltage for switching on 3
contacts:
DC correction factor for instantaneous release response value: NZM1: 1.25, NZM2:
1.35, NZM3: 1.45
Set current for Ii for DC = Set current Ii for AC / DC correction factor
Switching�of�one�pole Switching�of�one
via�two�series�contacts pole�via�three�series
contacts
Overvoltage category/pollution degree III/3
Rated insulation voltage Ui V 1000
Use in unearthed supply systems V
690
Switching�capacity
Rated short-circuit making capacity Icm
240 V 50/60 Hz Icm kA 121
400/415 V 50/60 Hz Icm kA 76
440 V 50/60 Hz Icm kA 63
525 V 50/60 Hz Icm kA 24
690 V 50/60 H Ic kA 14
Rated short-circuit breaking capacity Icn Icn
Icu to IEC/EN 60947 test cycle O-t-CO Icu kA
240 V 50/60 Hz Icu kA 55
400/415 V 50/60 Hz Icu kA 36
440 V 50/60 Hz Icu kA 30
525 V 50/60 Hz Icu kA 12
690 V 50/60 Hz Icu kA 8
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO Ics kA
230 V 50/60 Hz Ics kA 55
400/415 V 50/60 Hz Ics kA 36
12/11/2015 116439 - HPL-ED2015 V18.0 EN 2/9
440 V 50/60 Hz Ics kA 22.5
525 V 50/60 Hz Ics kA 9
690 V 50/60 Hz Ics kA 4
Maximum back-up fuse, if the expected short-circuit currents at the installation
location exceed the switching capacity of the circuit-breaker.
Rated short-time withstand current
t = 0.3 s Icw kA 3.3
t=1s Icw kA 3.3
Utilization category to IEC/EN 60947-2 A
Rated making and breaking capacity
Rated operational current Ie A
AC-1
380 V 400 V Ie A 500
415 V Ie A 500
690 V Ie A 500
AC--3
380 V 400 V Ie A 320
415 V Ie A 320
660 V 690 V Ie A 320
Lifespan, mechanical Operations 15000
Lifespan, electrical
AC-1
400 V 50/60 Hz Operations 5000
690 V 50/60 Hz Operations 3000
AC-2, AC-3
400 V 50/60 Hz Operations 2000
690 V 50/60 Hz Operations 2000
Max. operating frequency Ops/h 60
Current heat losses per pole at Iu are based on the maximum rated operational W 40
current of the frame size.
For current heat loss per pole the specification refers to the maximum rated
operational current of the frame size.
Total downtime in a short-circuit ms < 10
Terminal�capacity
Standard equipment Screw connection
Round copper conductor
Tunnel terminal
Solid mm
2 1 x (16 - 185)
Copper busbar (width x thickness) mm
Bolt terminal and rear-side connection
Screw connection M10
Design�verification�as�per�IEC/EN�61439
Technical data for design verification
Rated operational current for specified heat dissipation In A 320
Equipment heat dissipation, current-dependent Pvid W 94.0032
IEC/EN 61439 design verification
10.2 Strength of materials and parts
10.2.2 Corrosion resistance Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat Meets the product standard's requirements.
and fire due to internal electric effects
10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements.
10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated.
12/11/2015 116439 - HPL-ED2015 V18.0 EN 3/9
10.2.7 Inscriptions Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard's requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder's responsibility.
10.8 Connections for external conductors Is the panel builder's responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will
provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be
observed.
10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be
observed.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction
leaflet (IL) is observed.
Technical�data�ETIM�6.0
Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation prot. (EC000228)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system
protection ([email protected] [AJZ716010])
Rated permanent current Iu A 320
Rated voltage V 690 - 690
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz kA 36
Overload release current setting A 250 - 320
Adjustment range short-term delayed short-circuit release A 0-0
Adjustment range undelayed short-circuit release A 1920 - 3200
Integrated earth fault protection No
Type of electrical connection of main circuit Screw connection
Device construction Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting No
DIN rail (top hat rail) mounting optional No
Number of auxiliary contacts as normally closed contact 0
Number of auxiliary contacts as normally open contact 0
Number of auxiliary contacts as change-over contact 0
Switched-off indicator available No
With under voltage release No
Number of poles 4
Position of connection for main current circuit Front side
Type of control element Rocker lever
Complete device with protection unit Yes
Motor drive integrated No
Motor drive optional Yes
Degree of protection (IP) IP20
12/11/2015 116439 - HPL-ED2015 V18.0 EN 4/9
Characteristics
12/11/2015 116439 - HPL-ED2015 V18.0 EN 5/9
12/11/2015 116439 - HPL-ED2015 V18.0 EN 6/9
12/11/2015 116439 - HPL-ED2015 V18.0 EN 7/9
Dimensions
Blow out area, minimum clearance to other parts
Minimum clearance to adjacent parts
12/11/2015 116439 - HPL-ED2015 V18.0 EN 8/9
Additional�product�information�(links)
IL01208013Z�LZMC3�circuit-breaker,�LN3�switch-disconnector
IL01208013Z LZMC3 circuit-breaker, LN3 ftp://ftp.moeller.net/DOCUMENTATION/AWA_INSTRUCTIONS/IL01208013Z2012_02.pdf
switch-disconnector
12/11/2015 Eaton Industries GmbH 9/9
http://www.eaton.eu
© 12/2015 by Eaton Industries GmbH
116439 - HPL-ED2015 V18.0 EN