LOAD CELLS

SCA Series
Compression Weighing Load Cells

Capacities: 50,000 lb/22,680 kg,


100,000 lb/45,360 kg,
120,000 lb/54,430 kg
• Environmentally-sealed (IP68)
• Stainless steel construction
• 35'/10m integral shielded cable

These heavy-capacity compression load cells


are ideal for multi-cell applications including
truck scales, railroad track scales, and heavy-duty
tank/hopper weighing systems.
The SCA load cells are fabricated from stainless steel
to provide the ultimate in protection when caustic,
corrosive or wet environments are encountered.
Load cells are environmentally-sealed
for absolute water protection. Each load cell is fur-
nished with stainless steel load buttons on
each end, and an integral multi-conductor
MECHANICAL DATA cable secured by a strain relief seal.
Rated Capacity, 50,000 lb / 22,680 kg, 100,000 lb /
(R.C.) Emax 45,360 kg, 120,000 lb / 54,430 kg
Minimum Dead 500 lb / 226 kg, 1,000 lb / 454 kg
CERTIFICATE DATA
Load 1,200 lb / 544 kg
ISSUING BODY NTEP OIML
Safe Load Limit 150% R.C.
Certificate Number 89-042A4 R60/1991-
Ultimate Load 300% R.C. DK-97.04 rev 1
Deflection at R.C. 0.01 in / 0.33 mm Accuracy Class IIIL C3
Net Weight 50K-SCA: 13 lb / 5.8 kg Maximum Number of 10,000 3,000
100K-SCA: 10 lb / 4.8 kg Load Cell Intervals, nmax
120K-SCA: 11 lb / 5 kg
Single/Multiple M
Humidity Symbol CH
ELECTRICAL DATA
Minimum Load Cell 1.5 lb/0.68 1 lb/0.45 kg,
Rated Output 2mV/V Verification Interval Vmin kg, 3 lb/1.36 2 lb/0.9 kg,
kg, 3.6 2.4 lb/1.09 kg
Excitation Voltage, Minimum 10 VDC lb/1.63 kg
Excitation Voltage, Maximum 15 VDC
Cable Length 35 ft / 10 m ENVIRONMENTAL DATA
Terminal Resistance
Temperature Compensation Range -10 to +40˚C
Excitation 1,150 ± 60 ohms
Signal 1,050 ± 15 ohms Operating Temperature Range -29 to +93˚C
Zero Load Output >2% R.C. Construction & Protection Code CP-67 HU, IP68
Insulation Resistance >5,000 megohms Barometric Pressure Effect on <1 v (min)/1kPa
at 50 VDC Zero Load Output

Bulletin No. 263-6F


Model 50K-SCA
SCA Series Model 100K-SCA
Compression Weighing Load Cells Model 120K-SCA
1.77 inch
45 mm

7.24 inch 4.02 inch


184 mm 102 mm

4.02 inch
102 mm
3.11 inch
79 mm

Load button
not shown.
Shielded 4 Conductor Cable
State-of-the-Art Load Cell Manufacturing Facility
ELECTRICAL INFORMATION ISO 9001 Quality Environment
Green + excitation
Black - excitation

Shield - Yellow

White - signal
Red + signal

The Model SCA Load Cell meets or exceeds Class IIIL, VCAP CERTIFIED
10,000 division accuracy requirements in accordance Cardinal Scale has been found to fully comply
with NIST Handbook 44. A Certificate of Conformance with the Verified Conformity Assessment
CERTIFICATIONS (Number 89-042A4) has been issued under the Program (VCAP) administered by the National
National Type Evaluation Program (NTEP) of the Type Evaluation Program (NTEP) of the National
National Conference on Weights and Measures. R60/1991-DK-97.04 rev 1 Conference on Weights and Measures (NCWM).

Cardinal Scale reserves the right to improve, enhance or modify features and specifications without prior notice. All registered trademarks are the property of their respective owners.

Cardinal
Cardinal Scale Manufacturing Co.
®
SOLD BY:

203 E. Daugherty, Webb City, MO 64870 USA


Ph: 417-673-4631 or 800-441-4237 • Fax: 417-673-5001
www.CardinalScale.com
© Copyright 2016 Cardinal Scale Mfg. Co. • Printed in USA • CAR/00/1016/263-6F