Task No 34
Task No 34
task no 34
task no 34
task no 34
MECH. INSP.
A. Referenced Information
REFERENCE DESIGNATION
Ref. AMM Closing of the Fan Cowls
71-13-00-410-010 437AL(447AL),438AR(448AR)
Ref. AMM Operational Test of the FADEC SYSTEM on
73-22-00-710-040 the Ground
Ref. ASM 73-25-16
Ref. AMM Operational Test of the Thrust Reverser
78-31-00-710-041 System with the CFDS
Ref. AMM Removal of the Thrust Reverser Hydraulic
78-31-51-000-010 Control Unit (HCU)
Ref. AMM Installation of the Thrust Reverser Hydraulic
78-31-51-400-010 Control Unit (HCU)
Ref. Fig. Thrust Reverser (Engine 1)
3. Fault Confirmation
SUBTASK 78-30-00-710-258-A
task no 34
MECH. INSP.
(3) If the fault code readout in (1) does not give one of the above
listed fault codes:
- continue with fault confirmation by Engine Ground Run
Section 4.B below.
SUBTASK 78-30-00-710-066-A
B. Test
(1) Do the operational test of the thrust reverser system with the
CFDS (FADEC 1A and 1B) Ref. AMM 78-31-00-710-041.
4. Fault Isolation
Ref. Fig. Thrust Reverser (Engine 1)
SUBTASK 78-30-00-810-058-A
A. If the test gives the maintenance message PERM SW/HCU/HC1:
- Read the fault code shown on the FLIGHT DATA and
GROUND DATA of the FADEC (1A and 1B) menu on the
MCDU (Ref. 70-00-00 Page Block 301 Task Supporting Data).
- Make a record of the fault code.
(1) If the FADEC 1A menu gives the fault code DCVWAF:
- Replace the HCU-THRUST REV (4101KS) Ref. AMM
78-31-51-000-010 and Ref. AMM 78-31-51-400-010.
task no 34
MECH. INSP.
task no 34
MECH. INSP.
task no 34
MECH. INSP.
SUBTASK 78-30-00-710-259-A
B. Repeat the fault confirmation as given in Para. 3 using the same
method (FADEC Ground Test or Engine Ground Run) as before and
confirm fault elimination.
5. Close-up
SUBTASK 78-30-00-860-058-A
A. Make sure that the fan cowls 437AL and 438AR are closed Ref. AMM
71-13-00-410-010.
task no 34
MECH. INSP.
2 A
9 8
A 4
B 5
D 2
C 3
C 7
k 6
C 7
k 6
C 3
D 2
B 5
A 4
9 8
2 1
4 B