Roto Xtend Duty Fluid

Atlas Copco (India) Ltd


Chemwatch: 18-2825 Issue Date: 01/11/2019
Version No: 4.1 Print Date: 20/06/2024
Safety Data Sheet L.GHS.IND.EN.E

SECTION 1 Identification of the substance / mixture and of the company / undertaking

Product Identifier
Product name Roto Xtend Duty Fluid
Synonyms Product Code: 0017 5201 20
Chemical formula Not Applicable
Other means of 121, 0017 5201 20, 0017520120, 0017530036, 13100336838, 2901170000, 2901170100, 2901170200, 2901170300, LL-90-3-
identification 158

Relevant identified uses of the substance or mixture and uses advised against
Relevant identified uses Compressor oil.

Details of the manufacturer or supplier of the safety data sheet


Registered company name Atlas Copco (India) Ltd Atlas Copco Airpower NV
Address Sveanagar Bombay Pune Road Pune Dapodi India Boomsesteenweg 957 Wilrijk B2610 Belgium

Telephone +91 976 631 00 37 +32 3 870 2111


Fax +91(0)20 39 85 70 09 +32 3 870 2903
Website www.atlascopco.com http://www.atlascopco.com/sds
Email [email protected] [email protected]

Emergency telephone number


Association / Organisation CHEMWATCH EMERGENCY RESPONSE (24/7)
Emergency telephone
+918000403230
numbers
Other emergency
+61 3 9573 3188
telephone numbers

Once connected and if the message is not in your preferred language then please dial 01

SECTION 2 Hazards identification

Classification of the substance or mixture

Classification Not Applicable

Label elements

Hazard pictogram(s) Not Applicable

Signal word Not Applicable

Hazard statement(s)

Page 1 continued...
Chemwatch: 18-2825 Page 2 of 8 Issue Date: 01/11/2019
Part Number: Print Date: 20/06/2024
Roto Xtend Duty Fluid
Version No: 4.1

Not Applicable

Precautionary statement(s) Prevention


Not Applicable

Precautionary statement(s) Response


Not Applicable

Precautionary statement(s) Storage


Not Applicable

Precautionary statement(s) Disposal


Not Applicable

SECTION 3 Composition / information on ingredients

Substances
See section below for composition of Mixtures

Mixtures
CAS No %[weight] Name

Not Available NotSpec polyolefins


Not Available NotSpec additives

SECTION 4 First aid measures

Description of first aid measures


If this product comes in contact with eyes:
Wash out immediately with water.
Eye Contact
If irritation continues, seek medical attention.
Removal of contact lenses after an eye injury should only be undertaken by skilled personnel.
If skin or hair contact occurs:
Skin Contact Flush skin and hair with running water (and soap if available).
Seek medical attention in event of irritation.
If fumes, aerosols or combustion products are inhaled remove from contaminated area.
Inhalation
Other measures are usually unnecessary.
Immediately give a glass of water.
Ingestion
First aid is not generally required. If in doubt, contact a Poisons Information Centre or a doctor.

Indication of any immediate medical attention and special treatment needed


Treat symptomatically.

SECTION 5 Firefighting measures

Extinguishing media
Foam.
Dry chemical powder.
BCF (where regulations permit).
Carbon dioxide.
Do not use a water jet to fight fire.

Special hazards arising from the substrate or mixture


Avoid contamination with oxidising agents i.e. nitrates, oxidising acids, chlorine bleaches, pool chlorine etc. as ignition may
Fire Incompatibility
result

Advice for firefighters


Alert Fire Brigade and tell them location and nature of hazard.
Wear full body protective clothing with breathing apparatus.
Fire Fighting
Prevent, by any means available, spillage from entering drains or water course.
Use water delivered as a fine spray to control fire and cool adjacent area.
Fire/Explosion Hazard Combustible.
Slight fire hazard when exposed to heat or flame.
Heating may cause expansion or decomposition leading to violent rupture of containers.
On combustion, may emit toxic fumes of carbon monoxide (CO).
Combustion products include:
Continued...
Chemwatch: 18-2825 Page 3 of 8 Issue Date: 01/11/2019
Part Number: Print Date: 20/06/2024
Roto Xtend Duty Fluid
Version No: 4.1

carbon dioxide (CO2)


other pyrolysis products typical of burning organic material.

SECTION 6 Accidental release measures

Personal precautions, protective equipment and emergency procedures


See section 8

Environmental precautions
See section 12

Methods and material for containment and cleaning up


Remove all ignition sources.
Clean up all spills immediately.
Minor Spills
Avoid breathing vapours and contact with skin and eyes.
Control personal contact with the substance, by using protective equipment.

Moderate hazard.
Clear area of personnel and move upwind.
Major Spills
Alert Fire Brigade and tell them location and nature of hazard.
Wear breathing apparatus plus protective gloves.

Personal Protective Equipment advice is contained in Section 8 of the SDS.

SECTION 7 Handling and storage

Precautions for safe handling


Avoid all personal contact, including inhalation.
Wear protective clothing when risk of exposure occurs.
Safe handling
Use in a well-ventilated area.
Prevent concentration in hollows and sumps.
Store in original containers.
Keep containers securely sealed.
Other information No smoking, naked lights or ignition sources.
Store in a cool, dry, well-ventilated area.
Store out of direct sunlight

Conditions for safe storage, including any incompatibilities


Metal can or drum
Suitable container Packaging as recommended by manufacturer.
Check all containers are clearly labelled and free from leaks.
Avoid contamination of water, foodstuffs, feed or seed.
Storage incompatibility
Avoid reaction with oxidising agents

SECTION 8 Exposure controls / personal protection

Control parameters

Occupational Exposure Limits (OEL)

INGREDIENT DATA
Not Available

Emergency Limits

Ingredient TEEL-1 TEEL-2 TEEL-3


Roto Xtend Duty Fluid Not Available Not Available Not Available

Ingredient Original IDLH Revised IDLH


Roto Xtend Duty Fluid Not Available Not Available

MATERIAL DATA

Exposure controls
Appropriate engineering Engineering controls are used to remove a hazard or place a barrier between the worker and the hazard. Well-designed
controls engineering controls can be highly effective in protecting workers and will typically be independent of worker interactions to
provide this high level of protection.

Continued...
Chemwatch: 18-2825 Page 4 of 8 Issue Date: 01/11/2019
Part Number: Print Date: 20/06/2024
Roto Xtend Duty Fluid
Version No: 4.1

The basic types of engineering controls are:


Process controls which involve changing the way a job activity or process is done to reduce the risk.
Enclosure and/or isolation of emission source which keeps a selected hazard "physically" away from the worker and ventilation
that strategically "adds" and "removes" air in the work environment.

Individual protection
measures, such as
personal protective
equipment

"Safety glasses with side shields


Chemical goggles.
Eye and face protection Contact lenses may pose a special hazard; soft contact lenses may absorb and concentrate irritants. A written policy
document, describing the wearing of lenses or restrictions on use, should be created for each workplace or task. This should
include a review of lens absorption and adsorption for the class of chemicals in use and an account of injury experience.
Skin protection See Hand protection below

Wear general protective gloves, eg. light weight rubber gloves.


The selection of suitable gloves does not only depend on the material, but also on further marks of quality which vary from
manufacturer to manufacturer. Where the chemical is a preparation of several substances, the resistance of the glove material
Hands/feet protection can not be calculated in advance and has therefore to be checked prior to the application.
The exact break through time for substances has to be obtained from the manufacturer of the protective gloves and has to be
observed when making a final choice.
Personal hygiene is a key element of effective hand care.
Body protection See Other protection below
No special equipment needed when handling small quantities.
OTHERWISE:
Other protection Overalls.
Barrier cream.
Eyewash unit.

Respiratory protection
Type A Filter of sufficient capacity. (AS/NZS 1716 & 1715, EN 143:2000 & 149:2001, ANSI Z88 or national equivalent)

Selection of the Class and Type of respirator will depend upon the level of breathing zone contaminant and the chemical nature of the contaminant. Protection
Factors (defined as the ratio of contaminant outside and inside the mask) may also be important.

Required minimum protection Maximum gas/vapour concentration present in air p.p.m. (by Half-face Full-Face
factor volume) Respirator Respirator
up to 10 1000 A-AUS / Class1 -
up to 50 1000 - A-AUS / Class 1

up to 50 5000 Airline * -
up to 100 5000 - A-2
up to 100 10000 - A-3
100+ Airline**

* - Continuous Flow ** - Continuous-flow or positive pressure demand


A(All classes) = Organic vapours, B AUS or B1 = Acid gasses, B2 = Acid gas or hydrogen cyanide(HCN), B3 = Acid gas or hydrogen cyanide(HCN), E = Sulfur
dioxide(SO2), G = Agricultural chemicals, K = Ammonia(NH3), Hg = Mercury, NO = Oxides of nitrogen, MB = Methyl bromide, AX = Low boiling point organic
compounds(below 65 degC)

Cartridge respirators should never be used for emergency ingress or in areas of unknown vapour concentrations or oxygen content.
The wearer must be warned to leave the contaminated area immediately on detecting any odours through the respirator. The odour may indicate that the mask
is not functioning properly, that the vapour concentration is too high, or that the mask is not properly fitted. Because of these limitations, only restricted use of
cartridge respirators is considered appropriate.
Cartridge performance is affected by humidity. Cartridges should be changed after 2 hr of continuous use unless it is determined that the humidity is less than
75%, in which case, cartridges can be used for 4 hr. Used cartridges should be discarded daily, regardless of the length of time used

SECTION 9 Physical and chemical properties

Information on basic physical and chemical properties


Appearance Clear light brown liquid with slight hydrocarbon odour; does not mix with water.

Relative density (Water =


Physical state Liquid ~0.843
1)
Partition coefficient n-
Odour Not Available Not Available
octanol / water
Auto-ignition temperature
Odour threshold Not Available >320
(°C)

Continued...
Chemwatch: 18-2825 Page 5 of 8 Issue Date: 01/11/2019
Part Number: Print Date: 20/06/2024
Roto Xtend Duty Fluid
Version No: 4.1

Decomposition
pH (as supplied) Not Applicable Not Available
temperature (°C)
Melting point / freezing
-45 (pour pt.) Viscosity (cSt) 40-45
point (°C)
Initial boiling point and
>280 (IBP) Molecular weight (g/mol) Not Applicable
boiling range (°C)

Flash point (°C) 235 (COC) Taste Not Available


Evaporation rate Not Available Explosive properties Not Available
Flammability Not Applicable Oxidising properties Not Available
Surface Tension (dyn/cm
Upper Explosive Limit (%) 1 Not Available
or mN/m)
Lower Explosive Limit (%) 10 Volatile Component (%vol) Not Available
Vapour pressure (kPa) <0.0005 (@20C) Gas group Not Available

Solubility in water Immiscible pH as a solution (1%) Not Applicable


Vapour density (Air = 1) >1 VOC g/L Not Available

SECTION 10 Stability and reactivity

Reactivity See section 7

Chemical stability Product is considered stable and hazardous polymerisation will not occur.
Possibility of hazardous
See section 7
reactions
Conditions to avoid See section 7
Incompatible materials See section 7
Hazardous decomposition
See section 5
products

SECTION 11 Toxicological information

Information on toxicological effects


The material is not thought to produce adverse health effects or irritation of the respiratory tract (as classified by EC Directives
Inhaled using animal models). Nevertheless, good hygiene practice requires that exposure be kept to a minimum and that suitable
control measures be used in an occupational setting.

The material has NOT been classified by EC Directives or other classification systems as "harmful by ingestion". This is because
of the lack of corroborating animal or human evidence. The material may still be damaging to the health of the individual,
Ingestion
following ingestion, especially where pre-existing organ (e.g liver, kidney) damage is evident. Present definitions of harmful or
toxic substances are generally based on doses producing mortality rather than those producing morbidity (disease, ill-health).

Skin Contact The liquid may be miscible with fats or oils and may degrease the skin, producing a skin reaction described as non-allergic
contact dermatitis. The material is unlikely to produce an irritant dermatitis as described in EC Directives .

Eye Although the liquid is not thought to be an irritant (as classified by EC Directives), direct contact with the eye may produce
transient discomfort characterised by tearing or conjunctival redness (as with windburn).
Long-term exposure to the product is not thought to produce chronic effects adverse to health (as classified by EC Directives
Chronic
using animal models); nevertheless exposure by all routes should be minimised as a matter of course.

TOXICITY IRRITATION
Roto Xtend Duty Fluid
Not Available Not Available

Legend: 1. Value obtained from Europe ECHA Registered Substances - Acute toxicity 2. Value obtained from manufacturer's SDS.
Unless otherwise specified data extracted from RTECS - Register of Toxic Effect of chemical Substances

Acute Toxicity Carcinogenicity

Skin Irritation/Corrosion Reproductivity


Serious Eye
STOT - Single Exposure
Damage/Irritation
Respiratory or Skin
STOT - Repeated Exposure
sensitisation
Mutagenicity Aspiration Hazard

Legend: – Data either not available or does not fill the criteria for classification
– Data available to make classification

Continued...
Chemwatch: 18-2825 Page 6 of 8 Issue Date: 01/11/2019
Part Number: Print Date: 20/06/2024
Roto Xtend Duty Fluid
Version No: 4.1

SECTION 12 Ecological information

Toxicity

Endpoint Test Duration (hr) Species Value Source


Roto Xtend Duty Fluid Not Not Not
Not Available Not Available
Available Available Available

Legend: Extracted from 1. IUCLID Toxicity Data 2. Europe ECHA Registered Substances - Ecotoxicological Information - Aquatic Toxicity
4. US EPA, Ecotox database - Aquatic Toxicity Data 5. ECETOC Aquatic Hazard Assessment Data 6. NITE (Japan) -
Bioconcentration Data 7. METI (Japan) - Bioconcentration Data 8. Vendor Data

DO NOT discharge into sewer or waterways.

Persistence and degradability


Ingredient Persistence: Water/Soil Persistence: Air
No Data available for all ingredients No Data available for all ingredients

Bioaccumulative potential
Ingredient Bioaccumulation

No Data available for all ingredients

Mobility in soil
Ingredient Mobility
No Data available for all ingredients

SECTION 13 Disposal considerations

Waste treatment methods


Legislation addressing waste disposal requirements may differ by country, state and/ or territory. Each user must refer to laws
operating in their area. In some areas, certain wastes must be tracked.
A Hierarchy of Controls seems to be common - the user should investigate:
Reduction
Reuse
Recycling
Disposal (if all else fails)
Product / Packaging This material may be recycled if unused, or if it has not been contaminated so as to make it unsuitable for its intended use.
disposal DO NOT allow wash water from cleaning or process equipment to enter drains.
It may be necessary to collect all wash water for treatment before disposal.
In all cases disposal to sewer may be subject to local laws and regulations and these should be considered first.
Where in doubt contact the responsible authority.
Recycle wherever possible or consult manufacturer for recycling options.
Consult State Land Waste Authority for disposal.
Bury or incinerate residue at an approved site.
Recycle containers if possible, or dispose of in an authorised landfill.

SECTION 14 Transport information

Labels Required

Marine Pollutant NO

Land transport (UN): NOT REGULATED FOR TRANSPORT OF DANGEROUS GOODS

Air transport (ICAO-IATA / DGR): NOT REGULATED FOR TRANSPORT OF DANGEROUS GOODS

Sea transport (IMDG-Code / GGVSee): NOT REGULATED FOR TRANSPORT OF DANGEROUS GOODS

14.7.1. Transport in bulk according to Annex II of MARPOL and the IBC code
Not Applicable

14.7.2. Transport in bulk in accordance with MARPOL Annex V and the IMSBC Code
Product name Group

Continued...
Chemwatch: 18-2825 Page 7 of 8 Issue Date: 01/11/2019
Part Number: Print Date: 20/06/2024
Roto Xtend Duty Fluid
Version No: 4.1

14.7.3. Transport in bulk in accordance with the IGC Code


Product name Ship Type

SECTION 15 Regulatory information

Safety, health and environmental regulations / legislation specific for the substance or mixture

Additional Regulatory Information


Not Applicable

National Inventory Status


National Inventory Status
Australia - AIIC / Australia
Not Available
Non-Industrial Use
Canada - DSL Not Available
Canada - NDSL Not Available

China - IECSC Not Available


Europe - EINEC / ELINCS /
Not Available
NLP
Japan - ENCS Not Available
Korea - KECI Not Available
New Zealand - NZIoC Not Available
Philippines - PICCS Not Available

USA - TSCA Not Available


Taiwan - TCSI Not Available
Mexico - INSQ Not Available
Vietnam - NCI Not Available
Russia - FBEPH Not Available
Yes = All CAS declared ingredients are on the inventory
Legend: No = One or more of the CAS listed ingredients are not on the inventory. These ingredients may be exempt or will require
registration.

SECTION 16 Other information

Revision Date 01/11/2019


Initial Date 03/06/2010

SDS Version Summary


Version Date of Update Sections Updated
2.1 03/06/2010 Toxicological information - Chronic Health, Handling and storage - Storage (storage incompatibility)
4.1 01/11/2019 One-off system update. NOTE: This may or may not change the GHS classification

Other information
Classification of the preparation and its individual components has drawn on official and authoritative sources as well as independent review by the Chemwatch
Classification committee using available literature references.

The SDS is a Hazard Communication tool and should be used to assist in the Risk Assessment. Many factors determine whether the reported Hazards are Risks
in the workplace or other settings. Risks may be determined by reference to Exposures Scenarios. Scale of use, frequency of use and current or available
engineering controls must be considered.

Definitions and abbreviations


PC-TWA: Permissible Concentration-Time Weighted Average
PC-STEL: Permissible Concentration-Short Term Exposure Limit
IARC: International Agency for Research on Cancer
ACGIH: American Conference of Governmental Industrial Hygienists
STEL: Short Term Exposure Limit
TEEL: Temporary Emergency Exposure Limit。
IDLH: Immediately Dangerous to Life or Health Concentrations
ES: Exposure Standard
OSF: Odour Safety Factor

Continued...
Chemwatch: 18-2825 Page 8 of 8 Issue Date: 01/11/2019
Part Number: Print Date: 20/06/2024
Roto Xtend Duty Fluid
Version No: 4.1

NOAEL: No Observed Adverse Effect Level


LOAEL: Lowest Observed Adverse Effect Level
TLV: Threshold Limit Value
LOD: Limit Of Detection
OTV: Odour Threshold Value
BCF: BioConcentration Factors
BEI: Biological Exposure Index
DNEL: Derived No-Effect Level
PNEC: Predicted no-effect concentration

AIIC: Australian Inventory of Industrial Chemicals


DSL: Domestic Substances List
NDSL: Non-Domestic Substances List
IECSC: Inventory of Existing Chemical Substance in China
EINECS: European INventory of Existing Commercial chemical Substances
ELINCS: European List of Notified Chemical Substances
NLP: No-Longer Polymers
ENCS: Existing and New Chemical Substances Inventory
KECI: Korea Existing Chemicals Inventory
NZIoC: New Zealand Inventory of Chemicals
PICCS: Philippine Inventory of Chemicals and Chemical Substances
TSCA: Toxic Substances Control Act
TCSI: Taiwan Chemical Substance Inventory
INSQ: Inventario Nacional de Sustancias Químicas
NCI: National Chemical Inventory
FBEPH: Russian Register of Potentially Hazardous Chemical and Biological Substances

This document is copyright.


Apart from any fair dealing for the purposes of private study, research, review or criticism, as permitted under the Copyright Act, no part may be reproduced by any
process without written permission from CHEMWATCH.
TEL (+61 3) 9572 4700.

end of SDS

You might also like