Roto Xtend Duty Fluid SDS
Roto Xtend Duty Fluid SDS
Product Identifier
Product name Roto Xtend Duty Fluid
Synonyms Product Code: 0017 5201 20
Chemical formula Not Applicable
Other means of 121, 0017 5201 20, 0017520120, 0017530036, 13100336838, 2901170000, 2901170100, 2901170200, 2901170300, LL-90-3-
identification 158
Relevant identified uses of the substance or mixture and uses advised against
Relevant identified uses Compressor oil.
Once connected and if the message is not in your preferred language then please dial 01
Label elements
Hazard statement(s)
Page 1 continued...
Chemwatch: 18-2825 Page 2 of 8 Issue Date: 01/11/2019
Part Number: Print Date: 20/06/2024
Roto Xtend Duty Fluid
Version No: 4.1
Not Applicable
Substances
See section below for composition of Mixtures
Mixtures
CAS No %[weight] Name
Extinguishing media
Foam.
Dry chemical powder.
BCF (where regulations permit).
Carbon dioxide.
Do not use a water jet to fight fire.
Environmental precautions
See section 12
Moderate hazard.
Clear area of personnel and move upwind.
Major Spills
Alert Fire Brigade and tell them location and nature of hazard.
Wear breathing apparatus plus protective gloves.
Control parameters
INGREDIENT DATA
Not Available
Emergency Limits
MATERIAL DATA
Exposure controls
Appropriate engineering Engineering controls are used to remove a hazard or place a barrier between the worker and the hazard. Well-designed
controls engineering controls can be highly effective in protecting workers and will typically be independent of worker interactions to
provide this high level of protection.
Continued...
Chemwatch: 18-2825 Page 4 of 8 Issue Date: 01/11/2019
Part Number: Print Date: 20/06/2024
Roto Xtend Duty Fluid
Version No: 4.1
Individual protection
measures, such as
personal protective
equipment
Respiratory protection
Type A Filter of sufficient capacity. (AS/NZS 1716 & 1715, EN 143:2000 & 149:2001, ANSI Z88 or national equivalent)
Selection of the Class and Type of respirator will depend upon the level of breathing zone contaminant and the chemical nature of the contaminant. Protection
Factors (defined as the ratio of contaminant outside and inside the mask) may also be important.
Required minimum protection Maximum gas/vapour concentration present in air p.p.m. (by Half-face Full-Face
factor volume) Respirator Respirator
up to 10 1000 A-AUS / Class1 -
up to 50 1000 - A-AUS / Class 1
up to 50 5000 Airline * -
up to 100 5000 - A-2
up to 100 10000 - A-3
100+ Airline**
Cartridge respirators should never be used for emergency ingress or in areas of unknown vapour concentrations or oxygen content.
The wearer must be warned to leave the contaminated area immediately on detecting any odours through the respirator. The odour may indicate that the mask
is not functioning properly, that the vapour concentration is too high, or that the mask is not properly fitted. Because of these limitations, only restricted use of
cartridge respirators is considered appropriate.
Cartridge performance is affected by humidity. Cartridges should be changed after 2 hr of continuous use unless it is determined that the humidity is less than
75%, in which case, cartridges can be used for 4 hr. Used cartridges should be discarded daily, regardless of the length of time used
Continued...
Chemwatch: 18-2825 Page 5 of 8 Issue Date: 01/11/2019
Part Number: Print Date: 20/06/2024
Roto Xtend Duty Fluid
Version No: 4.1
Decomposition
pH (as supplied) Not Applicable Not Available
temperature (°C)
Melting point / freezing
-45 (pour pt.) Viscosity (cSt) 40-45
point (°C)
Initial boiling point and
>280 (IBP) Molecular weight (g/mol) Not Applicable
boiling range (°C)
Chemical stability Product is considered stable and hazardous polymerisation will not occur.
Possibility of hazardous
See section 7
reactions
Conditions to avoid See section 7
Incompatible materials See section 7
Hazardous decomposition
See section 5
products
The material has NOT been classified by EC Directives or other classification systems as "harmful by ingestion". This is because
of the lack of corroborating animal or human evidence. The material may still be damaging to the health of the individual,
Ingestion
following ingestion, especially where pre-existing organ (e.g liver, kidney) damage is evident. Present definitions of harmful or
toxic substances are generally based on doses producing mortality rather than those producing morbidity (disease, ill-health).
Skin Contact The liquid may be miscible with fats or oils and may degrease the skin, producing a skin reaction described as non-allergic
contact dermatitis. The material is unlikely to produce an irritant dermatitis as described in EC Directives .
Eye Although the liquid is not thought to be an irritant (as classified by EC Directives), direct contact with the eye may produce
transient discomfort characterised by tearing or conjunctival redness (as with windburn).
Long-term exposure to the product is not thought to produce chronic effects adverse to health (as classified by EC Directives
Chronic
using animal models); nevertheless exposure by all routes should be minimised as a matter of course.
TOXICITY IRRITATION
Roto Xtend Duty Fluid
Not Available Not Available
Legend: 1. Value obtained from Europe ECHA Registered Substances - Acute toxicity 2. Value obtained from manufacturer's SDS.
Unless otherwise specified data extracted from RTECS - Register of Toxic Effect of chemical Substances
Legend: – Data either not available or does not fill the criteria for classification
– Data available to make classification
Continued...
Chemwatch: 18-2825 Page 6 of 8 Issue Date: 01/11/2019
Part Number: Print Date: 20/06/2024
Roto Xtend Duty Fluid
Version No: 4.1
Toxicity
Legend: Extracted from 1. IUCLID Toxicity Data 2. Europe ECHA Registered Substances - Ecotoxicological Information - Aquatic Toxicity
4. US EPA, Ecotox database - Aquatic Toxicity Data 5. ECETOC Aquatic Hazard Assessment Data 6. NITE (Japan) -
Bioconcentration Data 7. METI (Japan) - Bioconcentration Data 8. Vendor Data
Bioaccumulative potential
Ingredient Bioaccumulation
Mobility in soil
Ingredient Mobility
No Data available for all ingredients
Labels Required
Marine Pollutant NO
Air transport (ICAO-IATA / DGR): NOT REGULATED FOR TRANSPORT OF DANGEROUS GOODS
Sea transport (IMDG-Code / GGVSee): NOT REGULATED FOR TRANSPORT OF DANGEROUS GOODS
14.7.1. Transport in bulk according to Annex II of MARPOL and the IBC code
Not Applicable
14.7.2. Transport in bulk in accordance with MARPOL Annex V and the IMSBC Code
Product name Group
Continued...
Chemwatch: 18-2825 Page 7 of 8 Issue Date: 01/11/2019
Part Number: Print Date: 20/06/2024
Roto Xtend Duty Fluid
Version No: 4.1
Safety, health and environmental regulations / legislation specific for the substance or mixture
Other information
Classification of the preparation and its individual components has drawn on official and authoritative sources as well as independent review by the Chemwatch
Classification committee using available literature references.
The SDS is a Hazard Communication tool and should be used to assist in the Risk Assessment. Many factors determine whether the reported Hazards are Risks
in the workplace or other settings. Risks may be determined by reference to Exposures Scenarios. Scale of use, frequency of use and current or available
engineering controls must be considered.
Continued...
Chemwatch: 18-2825 Page 8 of 8 Issue Date: 01/11/2019
Part Number: Print Date: 20/06/2024
Roto Xtend Duty Fluid
Version No: 4.1
end of SDS