E14F11P05
Twin Triplexer 380-960/1350-2200/2300- 2700, DC-sense with 4.3-
10 connectors
BTS-to-feeder and feeder-to-antenna application
Automatic dc switching with dc sense
New 4.3-10 connectors for improved PIM performance and size reduction
Product Classification
Product Type Triplexer
General Specifications
Color Gray
Modularity 2-Twin
Mounting Pole | Wall
Mounting Pipe Hardware Band clamps (2)
RF Connector Interface 4.3-10 Female
RF Connector Interface Body Style Long neck
Dimensions
Height 102 mm | 4.016 in
Width 168.5 mm | 6.634 in
Depth 116.5 mm | 4.587 in
Mounting Pipe Diameter Range 43–122 mm
Outline Drawing
Page 1 of 4
©2023 CommScope, Inc. All rights reserved. CommScope and the CommScope logo are registered trademarks of CommScope and/or its
affiliates in the U.S. and other countries. For additional trademark information see https://www.commscope.com/trademarks. All product names,
trademarks and registered trademarks are property of their respective owners. Revised: November 16, 2023
E14F11P05
Electrical Specifications
Impedance 50 ohm
Electrical Specifications, dc Power/Alarm
dc/AISG Pass-through Method Auto sensing
dc/AISG Pass-through Path Auto sensing circuitry detects dc/AISG signal presence and selects path
dc/AISG Pass-through, combiner Autosensing
dc/AISG Pass-through, demultiplexer Autosensing
Lightning Surge Current 10 kA
Lightning Surge Current Waveform 8/20 waveform
Electrical Specifications
Page 2 of 4
©2023 CommScope, Inc. All rights reserved. CommScope and the CommScope logo are registered trademarks of CommScope and/or its
affiliates in the U.S. and other countries. For additional trademark information see https://www.commscope.com/trademarks. All product names,
trademarks and registered trademarks are property of their respective owners. Revised: November 16, 2023
E14F11P05
Sub-module 1|2 1|2 1|2
Branch 1 2 3
Port Designation 380-960 1350-2200 2300-2700
Electrical Specifications, Band Pass
Frequency Range, MHz 380–960 1350–2200 2300–2700
Insertion Loss, typical, dB 0.2 0.2 0.2
Return Loss, typical, dB 20 20 20
Isolation, typical, dB 52 52 52
Input Power, RMS, maximum, W 200 200 200
Input Power, PEP, maximum, W 2000 2000 2000
3rd Order PIM, typical, dBc -162 -162 -162
3rd Order PIM Test Method Two +43 dBm carriers Two +43 dBm carriers Two +43 dBm carriers
Block Diagram
Logic Table
Page 3 of 4
©2023 CommScope, Inc. All rights reserved. CommScope and the CommScope logo are registered trademarks of CommScope and/or its
affiliates in the U.S. and other countries. For additional trademark information see https://www.commscope.com/trademarks. All product names,
trademarks and registered trademarks are property of their respective owners. Revised: November 16, 2023
E14F11P05
Environmental Specifications
Operating Temperature -40 °C to +65 °C (-40 °F to +149 °F)
Relative Humidity Up to 100%
Corrosion Test Method IEC 60068-2-11, 30 days
Environmental Test Method ETSI EN 300 019-1-4
Ingress Protection Test Method IEC 60529:2001, IP67
Packaging and Weights
Included Mounting hardware
Volume 2L
Weight, with mounting hardware 3.9 kg | 8.598 lb
Weight, without mounting hardware 3.5 kg | 7.716 lb
Page 4 of 4
©2023 CommScope, Inc. All rights reserved. CommScope and the CommScope logo are registered trademarks of CommScope and/or its
affiliates in the U.S. and other countries. For additional trademark information see https://www.commscope.com/trademarks. All product names,
trademarks and registered trademarks are property of their respective owners. Revised: November 16, 2023