requirements
▪ Virtual machine
▪ Oracle VM VirtualBox
▪ Windows XP (32-bit)
▪ Cable
▪ USB to RS-232, so far the only known-to-work models are:
▪ https://www.steren.com.mx/adaptador-usb-a-serial-db9-de-1-8-m.html
➢ Comment regarding the driver: La solución para que funcione con Windows 10 es instalar el Driver Versión 3.2.0.0 (No
importa que diga Windows Vista) que se descarga de http://obd2-
elm327.es/index.php?route=page/page/download&page_id=45&download_id=6 La solución paso a paso la pueden
encontrar en http://obd2-elm327.es/solucion-problema-driver-prolific-pl2303
▪ https://www.lindy.de/USB-auf-Seriell-Konverter.htm?websale8=ld0101.ld011101&pi=42811
➢ Driver to be found on same website
▪ Adaptor
▪ RS232 to RS232 (null modem cable)
▪ Selfmade:
shield
Global Safety Textiles Julien Targowski – Global maintenance – 01/2024 | Page 1
settings
▪ Connect cable to PC and check in „device manager“, which COM Port is used by the USB-to-serial converter:
▪ Open the settings of the virtual machine and activate the serial interface with COM1 and enter the COM adress that you
previously have found out from the device manager:
Global Safety Textiles Julien Targowski – Global maintenance – 01/2024 | Page 2
Software set up
▪ Move the 3 software folders „Ultraware“, „BRU Master“ and „UltraMaster-V1.62“ onto the Windows XP Virtual machine and
install them
Move to virtual
machine install
▪ After opening BRU Master or UltraMaster software, verify the following settings:
Global Safety Textiles Julien Targowski – Global maintenance – 01/2024 | Page 3
Parameterization
▪ Download parameters from drive. This might take some time and maybe only show results when scan is done 100%. Be
patient!
If: KA = warp let-off, if EWA = take-up
Check parameters
You can transfer parametersets from
one drive to another
by saving the parameters and
Troubleshooting
transferring it to the other drive:
and alarm tracing
File -> Save;
Communications -> Overwrite Drive
Parameters
Global Safety Textiles Julien Targowski – Global maintenance – 01/2024 | Page 4