2 CMX500 Specification
2 CMX500 Specification
Data Sheet
Version 06.00
Version 06.00, July 2022
CONTENTS
Definitions ....................................................................................................................................................................... 3
Introduction ..................................................................................................................................................................... 4
General specifications .................................................................................................................................................... 5
    Timebase OCXO, high performance .................................................................................................................................................. 5
Modulation source: arbitrary waveform generator (ARB) (prerequisite: R&S®CMX-B500A and R&S®CMX-KW601 options) .............. 5
IF analyzer......................................................................................................................................................................................... 9
RF generator ................................................................................................................................................................................... 15
RF analyzer ..................................................................................................................................................................................... 16
Option ............................................................................................................................................................................ 18
    R&S®CMX-KM600 5G NR analyzer option....................................................................................................................................... 18
Definitions
General
Product data applies under the following conditions:
Specification limit
Specification limit
                                                                                                           X-axis
                                          Measurement uncertainties               Guard band
Uncertainties
Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been
calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account
environmental conditions, aging, wear and tear.
Device settings and GUI parameters are indicated as follows: “parameter: value”.
Non-traceable specifications with limits, typical data as well as nominal and measured values are not warranted by Rohde & Schwarz.
In line with the 3GPP/3GPP2 standard, chip rates are specified in million chips per second (Mcps), whereas bit rates and symbol rates
are specified in billion bit per second (Gbps), million bit per second (Mbps), thousand bit per second (kbps), million symbols per
second (Msps) or thousand symbols per second (ksps), and sample rates are specified in million samples per second (Msample/s).
Gbps, Mcps, Mbps, Msps, kbps, ksps and Msample/s are not SI units.
Introduction
The R&S®CMX500 radio communication tester is a universal one-box network emulation and measurement test solution supporting
latest 3GPP 5G NR technology.
R&S®CMX500 one-box tester provides extensive device testing capability, including support for all 5G NR deployments covering LTE,
5G NR FR1 and FR2 in non-standalone (NSA) and standalone (SA) mode, for both FDD and TDD with an effortless setup and an
outstanding performance. For 5G NR FR1 frequency range as well as LTE, the R&S ®CMX500 provides integrated RF units that
operate in the frequency range from 400 MHz to 8 GHz.
Testing within the 3GPP FR2 frequency range can be conducted by combining the R&S®CMX500 with the R&S®CMXHEAD30 remote
radio head (RRH), which is a separate compact unit that performs upconversion and downconversion from IF to 5G NR FR2 frequency
ranges.
The split concept with the R&S®CMX500 and the R&S®CMXHEAD30 allows short RF cable lengths at the 5G NR FR2 frequency
range for an optimal link budget in radiated chamber test environments like the R&S ®CMQ500 shielding cube or the R&S®ATS800R
CATR rack based antenna test system.
Vector signal analysis and ARB generator are built-in capabilities of the R&S®CMX500 that allow efficient RF parametric testing of
both FR2 transmitters and FR2 receivers.
Receiver tests of 5G NR devices under 3GPP fading propagation conditions can be performed using the internal baseband fading
emulation.
The R&S®CMX500 can be used in all product development and lifecycle phases – from early R&D to service.
New instruments with the R&S®CMX-PB70H (R&S®CMX500 basic assembly) and R&S®CMX-B300B (R&S®CMX500 processing unit)
together with the R&S®CMX-B600A (R&S®CMX500 RF unit) offer higher performance and more capabilities:
•   Cell configurations supported by the previous versions R&S ®CMX-PB70B and R&S®CMX-B300A remain supported
•   Cell configurations are extended by adding a third R&S®CMX-B200A accelerator unit
•   FR2 capabilities are extended by supporting up to four R&S®CMX-B500A IF units
•   FR1 capabilities now available with two R&S®CMX-B600A RF units
General specifications
Timebase OCXO, high performance
Maximum frequency drift         in temperature range from 0 °C to +50 °C,   ±5 × 10–9
                                referenced to +25 °C
                                with instrument orientation                 ±1 × 10–9
Retrace                         at +25 °C,                                  ±5 × 10–9
                                after 24 hours power on/
                                2 hours power off/1 hour power on
Maximum aging                   at +25 °C,                                  ±3 × 10–8/year,
                                after 10 days of continuous operation       ±5 × 10–10/day
Warm-up time                    at +25 °C,                                  approx. 10 min
                                the frequency is in the range that is
                                10 times the frequency drift (±5 × 10–8)
USB interface
    R&S®CMX-B300A option                     for future use                               USB 3.0
USB interface
    DAU                                      for future use                               USB 3.0
 Interfaces
 IF In                                      IF input, port 1, port 2, port 3           SMA
 IF Out                                     IF output, port 1, port 2, port 3          SMA
 RRH Ref                                    500 MHz reference frequency,               SMA
                                            port 1, port 2, port 3
 RRH Control                                power and control proprietary interface    10-pin socket
                                            port 1, port 2, port 3
 Sensor 1, sensor 2, sensor 3               for R&S®NRPMx OTA power sensors            8-pin socket
IF generator
 IF Out                                     port 1, port 2, port 3                     SMA
 Frequency range                            inclusive modulation bandwidth             6 GHz to 20 GHz
 Frequency resolution                                                                  < 0.1 Hz
 Frequency uncertainty                                                                 same as timebase + frequency resolution
 Frequency settling time                                                               < 300 µs
 Output level repeatability                 typical values after 1 h warm-up time,     < 0.1 dB
                                            always returning to same level and
                                            frequency, no temperature change,
                                            insignificant time change
mmWave RF generator
Only in combination with accessories R&S®CMXHEAD30 remote radio head and R&S®CM-Z30A connection cable.
The R&S®CMXHEAD30 is a separate compact unit that performs upconversion and downconversion to 5G NR FR2 frequencies.
    Output level repeatability            typical values after 1 h warm-up time,   < 0.2 dB
                                          always returning to same level and
                                          frequency, no temperature change,
                                          insignificant time change
IF analyzer
IF In                                  port 1, port 2, port 3                      SMA
Frequency range                        inclusive modulation bandwidth              4 GHz to 20 GHz
Frequency resolution                                                               < 0.1 Hz
Frequency uncertainty                                                              same as timebase + frequency resolution
Expected nominal power setting range   PEP, for ADC full scale
                                         4 GHz to 20 GHz                           –5 dBm to +15 dBm
                                             -150
     Displ. Average Noise Level [dBm/Hz]
                                             -152
-154
                                                                                                                                                   05°C
                                             -156
                                                                                                                                                   15°C
                                             -158                                                                                                  23°C
                                                                                                                                                   35°C
                                             -160                                                                                                  45°C
-162
                                             -164
                                                 4000     6000      8000        10000            12000   14000     16000       18000       20000
                                                                                       Frequency [MHz]
                                                                 Measured at R&S®CMX500, port 3: displayed average noise level
Bandwidth up to 1 GHz
mmWave RF analyzer
Only in combination with accessories R&S®CMXHEAD30 remote radio head and R&S®CM-Z30A connection cable.
The R&S®CMXHEAD30 is a separate compact unit that performs upconversion and downconversion to 5G NR FR2 frequencies.
 Expected nominal power setting range     PEP, for ADC full scale
                                            28 GHz band                               –15 dBm to +15 dBm
                                            39 GHz band                               –15 dBm to +15 dBm
                                               -155
     Displ. Average Noise Level [dBm/Hz]       -156
                                               -157
                                               -158
                                               -159
                                               -160
                                               -161
                                               -162
                                               -163
                                               -164
                                               -165
                                               -166
                                               -167
                                                      23.5    24.5        25.5        26.5        27.5         28.5     29.5        30.5       31.5
                                                                                             Frequency [GHz]
Measured at R&S®CMXHEAD30 remote radio head, RF1: displayed average noise level from 23.5 GHz to 31.8 GHz
                                               -152
                                               -153
       Displ. Average Noise Level [dBm/Hz]
                                               -154
                                               -155
                                               -156
                                               -157
                                               -158
                                               -159
                                               -160
                                               -161
                                               -162
                                               -163
                                               -164
                                                       37        38              39          40           41           42            43           44
                                                                                              Frequency [GHz]
Measured at R&S®CMXHEAD30 remote radio head, RF1: displayed average noise level from 37 GHz to 44.3 GHz
 Frequency error          5G NR PUSCH, 11 OFDM symbols per            < ±0.01 ppm, as specified in
                          slot, mapping type A and single-symbol      3GPP TS 38.521-2 V16.5.0 and
                          DM-RS configuration type 1 with             TS 38.521-3 V16.5.0
                          2 additional DM-RS symbols,
                          for RF frequency error measurements
                          relative to the downlink signal
Spectrum measurements
FFT spectrum analyzer
 Frequency span                                                       10 MHz, 20 MHz, 40 MHz, 160 MHz,
                                                                      250 MHz, 500 MHz, 1 GHz
 FFT length                                                           1k, 2k, 4k, 8k, 16k
 Detector                                                             peak, RMS
Functions
 Interfaces
     RF Com1, RF Com 2                      simultaneous receiver and transmitter     2 × SnapN, RF input/output to DUT
                                            testing
     RF In 1, RF In 2                       transmitter testing                       2 × SnapN, RF input from DUT
     RF Out 1 to RF Out 4                   receiver testing                          4 × SnapN, RF output to DUT
 VSWR
   RF Com 1, RF Com 2                       400 MHz to 4000 MHz                       < 1.5
                                            4000 MHz to 7375 MHz                      < 1.6
                                            7375 MHz to 8000 MHz                      < 1.9
     RF In 1, RF In 2                       400 MHz to 8000 MHz                       < 1.8
     RF Out 1 to RF Out 4                   400 MHz to 8000 MHz                       < 1.8
RF generator
    Frequency range                                                                                       400 MHz to 8000 MHz
    Frequency resolution                                                                                  0.1 Hz
    Frequency uncertainty                                                                                 same as timebase + frequency resolution
    Modulation bandwidth
      RF Com 1, RF Com 2 and                          instantaneous bandwidth (iBW),                      1000 MHz
      RF Out 1 to RF Out 4                            non-contiguous
                                                      RF bandwidth                                        250 MHz
    Phase noise
      Integrated, 1 kHz to 50 MHz                     400 MHz to 3000 MHz                                 < –64 dBc
                                                      3000 MHz to 5750 MHz                                < –55 dBc
                                                      5750 MHz to 8000 MHz                                < –53 dBc
1
    Output level uncertainties are valid for continuous wave use. With wideband applications, additional uncertainties can occur.
RF analyzer
 Frequency range                                                                        400 MHz to 8000 MHz
 Frequency resolution                                                                   0.1 Hz
 Frequency uncertainty                                                                  same as timebase + frequency resolution
 Demodulation bandwidth
   RF Com 1, RF Com 2 and                                                               250 MHz
   RF In 1, RF In 2
 Level range
    RF Com 1, RF Com 2                         continuous power (RMS)                   max. +30 dBm
                                               continuous power (PEP)                   max. +38 dBm
                                               maximum input DC level                   0 V DC
     RF In 1, RF In 2                          continuous power (RMS)                   max. +25 dBm
                                               continuous power (PEP)                   max. +33 dBm
                                               maximum input DC level                   0 V DC
 Level uncertainty
    RF Com 1, RF Com 2 and                     temperature range: +15 °C to +35 °C,
    RF In 1, RF In 2                           within ±5 °C from last level alignment
                                               procedure temperature
                                                  400 MHz to 4000 MHz                   < ±0.7 dB
                                                  4000 MHz to 5800 MHz                  < ±0.8 dB
                                                  5800 MHz to 8000 MHz                  < ±1.0 dB
 Level uncertainty
    RF Com 1, RF Com 2 and                     temperature range: +5 °C to +45 °C,
    RF In 1, RF In 2                           within ±5 °C from last level alignment
                                               procedure temperature
                                                  400 MHz to 3500 MHz                   < ±2.0 dB
                                                  3500 MHz to 8000 MHz                  < ±3.0 dB
 Phase noise
   Integrated, 1 kHz to 50 MHz                 400 MHz to 3750 MHz                      < –61 dBc
                                               3750 MHz to 8000 MHz                     < –53 dBc
 RX DANL
   RF Com 1, RF Com 2                          400 MHz to 7000 MHz                      < –154 dBm (1 Hz)
                                               7000 MHz to 8000 MHz                     < –153 dBm (1 Hz)
     RF In 1, RF In 2                          400 MHz to 7000 MHz                      < –160 dBm (1 Hz)
                                               7000 MHz to 8000 MHz                     < –157 dBm (1 Hz)
Option
R&S®CMX-KM600 5G NR analyzer option
 EVM                                   FR1, bandwidth: 100 MHz, SCS: 30 kHz,
                                       16QAM
                                         level > –20 dBm                       < 1.0 %
General data
Remote control interfaces (rear panel)
LAN                                                                              Ethernet RJ-45 connector, 1000 Mbps
USB device                               with R&S®CMX-PB70B only                 USB 3.0 type B connector
Display
Size                                                                             1.9" e-paper TFT EPD black/white display
Resolution                                                                       144 × 128 pixel
Environmental conditions
Temperature                              operating temperature range             +5 °C to +45 °C
                                         storage temperature range               –25 °C to +60 °C
Damp heat                                                                        +40 °C, 80 % rel. humidity, steady state,
                                                                                 in line with EN 60068-2-78
 Product conformity
 Electromagnetic compatibility         EU: in line with EMC Directive               applied harmonized standards:
                                       2014/30/EU;                                  • EN 61326-1 (industrial environment)
                                       UK: in line with Electromagnetic             • EN 61326-2-1
                                       Compatibility Regulations 2016               • EN 55011 (class A)
                                       (S.I. 2016/1091)
 Electrical safety                     EU: in line with Low Voltage Directive       applied harmonized standard:
                                       2014/35/EU;                                  EN 61010-1
                                       UK: in line with Electrical Equipment
                                       (Safety) Regulations 2016
                                       (S.I. 2016/1101)
                                       USA/Canada                                   applied standards:
                                                                                    • UL 61010-1
                                                                                    • CAN C22.2 No. 61010.1
 International approvals               VDE – Association for Electrical,            VDE mark,
                                       Electronic and Information Technologies      certificate: 40050175
                                       CSA – Canadian Standards Association         CCSAUS mark,
                                                                                    certificate: 80004420,
                                                                                    file number: LR114196
                                       Korea – KC                                   R-R-RnS-CCMX5HG
 RoHS                                  EU: in line with Directive 2011/65/EU on     applied harmonized standard:
                                       the restriction of the use of certain        EN IEC 63000
                                       hazardous substances in electrical and
                                       electronic equipment;
                                       UK: in line with Restriction of the Use of
                                       Certain Hazardous Substances in
                                       Electrical and Electronic Equipment
                                       Regulations 2012 (S.I. 2012/3032)
Extras
R&S®CMXHEAD30 remote radio head
General data
 Interfaces
 RF1, RF2                             µW                                         wear adapter, 2.4 mm (Q), female
 IF In                                IF input                                   SMA
 IF Out                               IF output                                  SMA
 RRH Ref                              500 MHz reference frequency                SMA
 Power and control                    proprietary interface                      10-pin socket
 Environmental conditions
 Temperature                          operating temperature range                +5 °C to +45 °C
                                      storage temperature range                  –25 °C to +60 °C
 Damp heat                                                                       +40 °C, 80 % rel. humidity, steady state,
                                                                                  in line with EN 60068-2-78
 Product conformity
 Electromagnetic compatibility        EU: in line with                           applied harmonized standards:
                                      EMC Directive 2014/30/EC                   • EN 61326-1 (industrial environment)
                                                                                 • EN 61326-2-1
                                                                                 • EN 55011 (class A)
Ordering information
    Designation                                                                      Type                                  Order No.
    Radio communication tester;                                                      R&S®CMX500                            1201.0002K70
    instrument with following accessories: power cords, operating manual
    (getting started), R&S®CMX-B300A/R&S®CMX-B300B cables and
    adapters, R&S®CMX-PB70B/R&S®CMX-PB70H cables and adapters
    R&S®CMX500 basic assembly                                                        R&S®CMX-PB70B                         1222.0676.03
    R&S®CMX500 basic assembly                                                        R&S®CMX-PB70H                         1222.0676.09
    R&S®CMX accelerator unit                                                         R&S®CMX-B200A                         1222.0747.02
    R&S®CMX processing unit                                                          R&S®CMX-B300A                         1222.0801.02
    R&S®CMX processing unit                                                          R&S®CMX-B300B                         1222.0801.03
    R&S®CMX IF unit                                                                  R&S®CMX-B500A                         1222.0924.02
    R&S®CMX RF unit                                                                  R&S®CMX-B600A                         1222.0953.02
    Option
    5G NR analyzer                                                                   R&S®CMX-KM600                         1222.4013.02
    Extras
    Remote radio head                                                                R&S®CMXHEAD30                         1201.0002K73
    Hardware unit                                                                    R&S®CMXH-B73A                         1430.9106.02
    Remote radio head connection cable, length: 3 m                                  R&S®CM-Z30A                           1212.1040.02
    Monitor                                                                          R&S®CMX-ZG100A                        1222.3100.02
    Monitor mount                                                                    R&S®CMX-Z101A                         1222.3098.02
    19" adapter, 7 HU, 1/1                                                           R&S®ZZA-KN7                           1175.3062.00
    Service options
    Extended warranty, one year                                                      R&S®WE1                               Please contact your local
    Extended warranty, two years                                                     R&S®WE2                               Rohde & Schwarz sales
    Extended warranty, three years                                                   R&S®WE3                               office.
    Extended warranty, four years                                                    R&S®WE4
    Extended warranty with calibration coverage, one year                            R&S®CW1
    Extended warranty with calibration coverage, two years                           R&S®CW2
    Extended warranty with calibration coverage, three years                         R&S®CW3
    Extended warranty with calibration coverage, four years                          R&S®CW4
    Extended warranty with accredited calibration coverage, one year                 R&S®AW1
    Extended warranty with accredited calibration coverage, two years                R&S®AW2
    Extended warranty with accredited calibration coverage, three years              R&S®AW3
    Extended warranty with accredited calibration coverage, four years               R&S®AW4
For more ordering information about available options, please contact your local Rohde & Schwarz expert to find the
solution that best meets your needs.
The terms HDMI and HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing, LLC
in the United States and other countries.
2
    Excluding defects caused by incorrect operation or handling and force majeure. Wear-and-tear parts are not included.
www.rohde-schwarz.com
                                                                                                             5216412722
                                                                                                    5216.4127.22 06.00 PDP/PDW 1 en