DETACHABLE CONNECTOR TYPE

DIODE BLOCK UNIT

Power supply fault output


NC relay contact

Input power ON Indicator

Output power ON Indicator


Detachable Connector

35mm DIN Rail Mountable


P-0R-24-10-S1

ize
p a ct S
Power Supply Input P-0R-24-20-S1 Com 8 mm
4
ize
p a ct S
Com 8 mm
4
SCREW CONNECTOR TYPE
DIODE BLOCK UNIT

Power supply fault output


NC relay contact

Input power ON Indicator

Output power ON Indicator


Detachable Connector

35mm DIN Rail Mountable P-0R-24-10-S3

ize
p a ct S
Power Supply Input P-0R-24-20-S3 Com 8 mm
4
ize
p a ct S
Com 8 mm
4
SCHEMATIC BLOCK DIAGRAM TO USE DIODE BLOCK
FOR BOTH DETACHABLE & SCREW TYPE CONNECTOR

NC CO NC CO

+VE -VE +VE -VE

OUTPUT ON LED OUTPUT ON LED

DIODE BLOCK UNIT-1 DIODE BLOCK UNIT--2

1 2 3 4

INPUT ON LED INPUT ON LED

INPUT INPUT
SUPPLY-A SUPPLY-B

+ +

+VE -VE
POWER POWER
SUPPLY-A SUPPLY-B
-VE +VE
+VE

+VE

-VE

-VE

TO LOAD

This Diode Block Unit has one Seriers diode in the +ve & ve supply line in the unit. This isolates both +ve & -ve Power
Supply lines with the other power supplies.

To create power supply redundancy through these units the output of each of power supply is connected at the input
of each of these Diode Block Unit with right ploarity & output from these units are connected in parallel i.e +ve
terminal to +ve terminal & -ve terminal to -ve terminal at the output of each Diode Block Unit.

PI. Note: One Diode Block Unit is required for each one of the power supplies. There are two types of diode block
available screw type connector & Detachable type connector.
OR-ING DIODE BLOCK
SCREW TYPE

Model No.: P-OR-24-40-A3

General Information
The OR-ING unit combines two or more power sources to create
redundant power source preserving the output power supply in case
one of the input sources fails. In this situation of input power failure,
the next power supply feeds the power quickly to prevent the system
bus voltage from failing and bus collapse. The power supply failure
signal is given by relay N/C contact

Dimensions in mm. Specications


Input - 24VDC supply -1no’s (standard)

Output current - Model No. Current Rating Voltage


125 P-0R-24-40-S3 40 Amps 24VDC

Overload - 10%max.
Drop - 0.65 volts max DC at 20A

Di-Electric strength - 1KV AC


(between input / output to body)

Insulation resistance -100 mega Ohm @ 500 VDC min.


Fault
NO CO NC

R1

(between input / output to body)


131

Input
PS1

Working Temperature - 550C Ambient max.


Output

Indicators :
Input power supply - 1 green LED for each power supply
Output power supply - 1 green LED for output
output - 1N/C Relay Contact
Rated 5A @ 24VDC & 5A @ 230VAC in
case of failure of any one of the Input
35
power supply
131
Conductor cross section - 0.2-4.02mm solid
0.2-2.52solid
AWG 24-12

Dimension (LxBxH) in mm- 131 x 68 x 131


131 Mounting - 35 mm DIN Rail
Weight - 1.2 Kgs.
OR-ING DIODE UNIT Model No.:P-OR-24-40-A3

Custom built OR ing units can be designed and built to suit


Email: [email protected]

NO CO NC
NO CO NC

the special requirements.


POWER SUPPLY

24 VDC.40
OUTPUT
INPUT
24 VDC

168
14

20

Approvals
OR-ING DIODE BLOCK
SCREW TYPE
Model No.: P-OR-24-5-S3
Model No.: P-OR-24-10-S3
Model No.: P-OR-24-20-S3

General Information
The OR-ING unit combines two or more power sources to create
redundant power source preserving the output power supply in case
one of the input sources fails. In this situation of input power failure,
the next power supply feeds the power quickly to prevent the system
bus voltage from failing and bus collapse. The power supply failure
signal is given by relay N/C contact

Dimensions in mm. Specications


Input - 24VDC supply -1no’s (standard)

Output current - Model No. Current Rating Voltage


125 P-0R-24-5-S3 5 Amps 24VDC
P-0R-24-10-S3 10 Amps 24VDC
P-0R-24-20-S3 20 Amps 24VDC

Overload - 10%max.
Drop - 0.65 volts max DC at 5A,10A & 20A

Di-Electric strength - 1KV AC


(between input / output to body)
Fault
NO CO NC

R1
131

Insulation resistance -100 mega Ohm @ 500 VDC min.


Input
PS1

Output

(between input / output to body)


0
Working Temperature - 55 C Ambient max.

Indicators :
Input power supply - 1 green LED for each power supply
Output power supply - 1 green LED for output
35 output - 1N/C Relay Contact
131 Rated 5A @ 24VDC & 5A @ 230VAC in
case of failure of any one of the Input
power supply

Conductor cross section - 0.2-4.02mm solid


0.2-2.52mm solid
AWG 24-12
131
Dimension (LxBxH) in mm- 131 x 48 x 131
Mounting - 35 mm DIN Rail
OR-ING DIODE UNIT Model No.:P-OR-24-10-S3

Weight - 1.2 Kgs.


Email: [email protected]

NO CO NC
NO CO NC
POWER SUPPLY

24 VDC.10A
OUTPUT
INPUT
24 VDC
14

48
20

Custom built OR ing units can be designed and built to suit


the special requirements.

Approvals
OR-ING DIODE BLOCK
DETACHABLE TYPE
Model No.:P-0R-24-05-S1
Model No.:P-0R-24-10-S1
Model No.:P-0R-48-05-S1
Model No.:P-0R-48-10-S1
General Information
The Diode Block unit comprises of power supply isolating diodes in
positive and negative supply lines of the input power supply.
for redundancy in the power supply to the control unit the output of two
or more such units are connected in parallel. In the situation where
input to one of the oring unit power supply fails, the next power supply
connected will feed the power quickly to prevent the system bus
voltage from failing and bus collapse. 1N/C relay contact is brought
out from each oring unit for supply failure alarm.

Dimensions in mm. Specications


Input - 24V DC supply -1nos (standard)
48V DC supply -1nos (standard)
Output current - Model No. Current Rating Voltage
125
P-0R-24-05-S1 05 Amps 24VDC
P-0R-24-10-S1 10 Amps 24VDC
P-0R-48-05-S1 05 Amps 48VDC
P-0R-48-10-S1 10 Amps 48VDC

Overload - 10%max.
Drop - 0.65 volts max DC at 5A / 10A

Di-Electric strength - 1KV AC


Fault
NO

R1

(between input / output to body)


CO
131

Input
Ps1

Output

Insulation resistance -100 mega Ohm @ 500 VDC min.


(between input / output to body)
0
Working Temperature - 55 C Ambient max.

Indicators :
Input power supply - 1 green LED for each power supply
Output power supply - 1 green LED for output
35
131 output - 1N/C Relay Contact
Rated 5Amps @ 24VDC/230VAC
incase of failure of the input
power supply.

Conductor cross section - 0.20 - 2.5 mm2 solid


0.20 - 2.5 mm2 stranded
AWG 24-12
131

Dimension (LxBxH)mm - 131 x 48 x 131


OR-ING DIODE UNIT Model No.:P-OR-24-10-S1
Mounting - 35mm DIN Rail
NO CO
Email: [email protected]

NO CO

Weight - 0.5Kg.Approx
POWER SUPPLY

24 VDC.10A
OUTPUT
INPUT
24 VDC
14

48
20

Custom built OR ing units can be designed and built to suit


the special requirements.

Approvals
OR-ING DIODE BLOCK
DETACHABLE TYPE

Model No.:P-0R-24-20-S1
Model No.:P-0R-48-20-S1

General Information
The Diode Block unit comprises of power supply isolating diodes in
positive and negative supply lines of the input power supply.
for redundancy in the power supply to the control unit the output of two
or more such units are connected in parallel. In the situation where
input to one of the oring unit power supply fails, the next power supply
connected will feed the power quickly to prevent the system bus
voltage from failing and bus collapse. 1N/C relay contact is brought

Dimensions in mm. Specications


Input - 24V DC supply -1nos (standard)
- 48V DC supply -1nos (standard)
Model No. Current Rating Voltage
125 P-0R-24-20-S1 20 Amps 24VDC
P-0R-48-20-S1 20 Amps 48VDC

Overload - 10%max.
Drop - 0.65 volts max DC at 20A

Di-Electric strength - 1KV AC


(between input / output to body)
Fault
NO

R1

Insulation resistance -100 mega Ohm @ 500 VDC min.


CO

(between input / output to body)


131

Input
PS1

Output

Working Temperature - 550C Ambient max.

Indicators :
Input power supply - 1 green LED for each power supply
Output power supply - 1 green LED for output
output - 1N/C Relay Contact
Rated 5Amps @ 24VDC/230VAC
35
incase of failure of the input
131
power supply.

Conductor cross section - 0.20 - 4.0 mm2 solid


0.20 - 4.0 mm2 stranded
AWG 24-10

131 Dimension (LxBxH)mm - 131 x 48 x 131


Mounting - 35mm DIN Rail
Weight - 0.5Kg.Approx
OR-ING DIODE UNIT Model No.:P-OR-24-10-S1
Email: [email protected]

NO CO
NO CO
POWER SUPPLY

Custom built OR ing units can be designed and built to suit


24 VDC.10A
OUTPUT
INPUT
24 VDC

the special requirements.