Technical Data

High Frequency Pulse Generator

Model 351

General Signals
The Single or Dual Output High Frequency Pulse Genera- Pulse A&B: Dual Output 90° Electrically Out-of-Phase
tor is a photo electric device used to provide two output Phase Error: 15 Maximum
signals proportional to unit volume while maintaining a Amplitude: 0 to V + (500 ohm Internal Pull-up, No Load);
mechanical meter-to-register link. Signal outputs are elec- 0-5 Vdc +/- 0.2 Vdc (249 ohm Internal Pull-up, No Load)
trically 90 degree out-of-phase and are used primarily for Index: Open collector, 1 pulse per revolution 25 Vdc maxi-
pulse security. Although designed for use in meter proving, mum 100 mA maximum
the Dual Phase generator can be used on any application Pulse Duration: 90 +/- 10% of shaft rotation
requiring a high resolution signal indicating throughput or
rate of flow. Design Features
• Converts mechanical rotation into electrical pulses.
• Adapts to most meters.
Wiring • Self-contained, optical encoder module.
• Explosion-proof and weather tight (1/2” conduit)
• No calibration adjustment required
• Maintenance-free
• Temperature: -40°F to 185°F (-40°C to 85°C).
• Long Distance operation
• Low output impedance
• Low torque and low speed
• Open collector indexing output provides one pulse per
revolution

Power Requirements
12 to 24 Vdc +/- 10%
88 to 140 mA (Depending on Input voltage/Output
configuration).
Load Impedance: 5 k ohms
Temperature Range
-40°F to 185°F (-40°C to 85°C) Connections
1/2” Conduit, or quick connect
Shipping Wieght and Volume (Approximate)
8 lbs @ 0.122 CU. Feet Environmental:
3.6kg @ 0.003 Cu. Meters NEMA 4
IP66
Maximum RPM
Pulser Shaft: 1000 rpm maximum gear changer: Hazardous area approvals:
250 rpm maximum Explosion-proof
UL: Class I, Groups C and D
CSA: Class I, Groups C and D
NEPSI (China) Ex d IIB T4 Gb
Technical Data ds351_r5 Page 1/2
Recommended Cable Length Standard Pulse Rates
The recommended cable lengths are based on 18 gauge
tinned copper shielded cable with a load impedance of
5 k ohm (recommended minimum) and cable capacitance of Typical Accessory
Pulses per revolution
27pf/ft. When other type cables are used the factory must Block Gear Ratios
be consulted to determine permissible cable lengths. 1:1:1 100 or 256
1:2:1 200 or 512
Pulse Output Frequency Maximum Cable lengths 1:4:1 400 or 1024
1,000 Hz 3,700 ft.
2,000 Hz 1,850 ft. Note: Actual K-factor (Pulse per gallon) is dependent upon
meter output
3,000 Hz 1,185 ft.
4,000 Hz 925 ft.
5,000 Hz 740 ft.

Dimensions (For Certified Dimensional Prints - Consult Factory)

WARNING:
Do NOT operate this instrument in excess of the Brodie International
specifications listed. Failure to heed this warning
could result in serious injury and/or damage to the P.O. Box 450 (30459-0450)
equipment. 19267 Highway 301 North
Statesboro, GA 30461
USA

Phone: +1 (912) 489-0200


Fax: +1 (912) 489-0294

Technical Data ds351_r5 Page 2/2